• Title/Summary/Keyword: 필요환기량

Search Result 107, Processing Time 0.03 seconds

Cooling Control of Greenhouse Using Roof Window Ventilation by Simple Fuzzy Algorithm (단순 퍼지 제어기법을 이용한 온실의 천창환기에 의한 냉방제어)

  • Min, Young-Bong;Yoon, Yong-Cheol;Huh, Moo-Ryong;Kang, Dong-Hyun;Kim, Hyeon-Tae
    • Journal of agriculture & life science
    • /
    • v.44 no.4
    • /
    • pp.69-77
    • /
    • 2010
  • Fuzzy control is widely used for improving temperature control performance as controlling ventilation in greenhouse because the technique can respond more flexibly to the outside air temperature and wind speed. By pre-studied PID and normal fuzzy control this study was performed to obtain the fundamental data that can be established in better greenhouse ventilation control method. The temperature control error by the simple fuzzy control was $1.2^{\circ}C$. The accumulated operating size of the window and the number of operating were 84% and 13, respectively. These showed equivalent control performance with pre-studied result that control error. The accumulated operating size of the window and the number of operating were 75% and 12, respectively. The proposed fuzzy technique was simple control logic method compared with step and PID control methods, but it showed equivalent performance. Therefore, the proposed simple fuzzy control method could be used in micro controller of small programmable memory size and many applications.

Estimation of Required Ventilation Rate in Train (열차 내에서의 필요 환기량 추정)

  • 김신도;유성옥;봉춘근;이정주
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.376-377
    • /
    • 1999
  • 전세계의 많은 대도시들은 인구의 과밀화, 차량의 증가로 인한 교통혼잡 등으로 인해 많은 어려움을 겪고 있으며, 우리 나라도 '교통대란'이라고 할만큼 심각한 상황에 처해 있다. 이에 따라 1974년 1호선 9개역을 시발로 전국적으로 약 1,000km에 달하는 지하전철구간이 운행 건설 중이다. 지하철에 의한 수송 분담율도 꾸준히 증가하여 현재 서울에서의 경우 34%정도에 이르고 있으며, 2000년 이후에는 45%이상을 차지할 것으로 예상하고 있다.(중략)

  • PDF

탐방-(주)상일테크

  • Jang, Seong-Yeong
    • KOREAN POULTRY JOURNAL
    • /
    • v.39 no.5 s.451
    • /
    • pp.103-105
    • /
    • 2007
  • 적절한 환기는 여름철 고온으로 인한 스트레스 해결과 원활한 사료 섭취로 기간 증체율을 높이면서 폐사율 감소 효과를 볼 수 있다. 그 뿐 아니라 바닥건조를 통해 파리, 모기 등 해충으로 인한 질병 예방으로 위생적인 사육환경 조성과 톱밥 투여량의 감소로 연간 경영비용이 절감되는 효과를 기대할 수 있다. 유난히 길었던 겨울 한파가 지나고, 기온이 상승하면서 계사 점검이 필요한 시기가 왔다. 이와 관련하여 여름 혹서기에 대비해 12년간 국가연구소와 공동개발로 농축산 전용 환풍기를 생산하는 (주)상일테크(대표 정상택)를 방문해 고객 만족을 위한 끊임없는 연구개발 사업에 대해 들어보았다.

  • PDF

Proposal for Ignition Source and Flammable Material Safety Management through 3D Modeling of Hazardous Area: Focus on Indoor Mixing Processes (폭발위험장소 구분도의 3D Modeling을 통한 점화원 및 가연물 안전관리 방안 제안: 실내 혼합공정을 중심으로)

  • Hak-Jae Kim;Duk-Han Kim;Young-Woo Chon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.47-59
    • /
    • 2024
  • Purpose: This study aims to propose measures for the prevention of fire and explosion accidents within manufacturing facilities by improving the existing classification criteria for hazardous locations based on the leakage patterns of flammable liquids. The objective is to suggest ways to safely manage ignition sources and combustible materials. Method: The hazardous locations were calculated using "KS C IEC 60079-10-1," and the calculated explosion hazard distances were visualized in 3D. Additionally, the formula for the atmospheric dispersion of flammable vapors, as outlined in "P-91-2023," was utilized to calculate the dispersion rates within the hazardous locations represented in 3D. Result: Visualization of hazardous locations in 3D enabled the identification of blind spots in the floor plan, facilitating immediate recognition of ignition sources within these areas. Furthermore, when calculating the time taken for the Lower Explosive Limit (LEL) to reach within the volumetric space of the hazardous locations represented in 3D, it was found that the risk level did not correspond identically with the explosion hazard distances. Conclusion: Considering the atmospheric dispersion of flammable liquids, it was concluded that safety management should be conducted. Therefore, a method for calculating the concentration values requiring detection and alert based on realistically achievable ventilation rates within the facility is proposed.

On-site Application of a Vehicle Tunnel Ventilation Simulator (도로터널 환기시뮬레이션 모델 현장적용 연구)

  • 이창우;김효규
    • Tunnel and Underground Space
    • /
    • v.11 no.4
    • /
    • pp.319-327
    • /
    • 2001
  • Introduction of new design tools has been required to optimally design and operate the ventilation system of long vehicle tunnels.. The demand has led to wide spread use of the simulation technique throughout the would to analysis the dynamic relationship among the variables associated with vehicle tunnel ventilation. This paper aims at performing on-site study at local tunnels to test the applicability of NETVEN, a simulation model vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels model of vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels employing different ventilation systems as well as traffic methods. There were some discrepancies sound between the simulation output and measurements and the following four factors are considered to mainly cause those disagreement. (1) The real situation shows distinctive transient and retarding characteristics with respect to air flow and contaminant dispersion, while ventilation forces are not steady-state and in particular those traffic and climatic variables show significant instantaneous variation. (3) Near the exit portal, the CO levels show bigger differences. The general trend is that data with higher CO concentrations carry bigger discrepancies. Turbulent diffusion is though to be the main reason for it and also contribute to the fact hat the highest CO concentrations are found at the locations somewhat inward, not at the exit portals. (4) Higher traffic rate results in higher discrepancies of ventilation velocity. Along with the exhaust characteristics, the vehicle aerodynamic characteristics need to be studied continuously in order to reduce the velocity disagreement.

  • PDF

A Study on Indoor Environment Performances of Power Yacht in Summer Season (여름철 파워요트 실내환경 성능에 관한 연구)

  • Lee, Han-Seok;Doe, Guen-Young;Lim, Duck-Min;Kim, Hak-Chul
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.175-180
    • /
    • 2009
  • In this study, the basic data were collected for improving the amenity of indoor environment of a super yacht and the performance of indoor environment was analyzed by utilizing measured data during summer period. Through the results of examination, the following conclusions are drawn. 1) It is estimated that, in case of closing the door of Saloon connected with outside, there is little inflow of exhaust gas, but when the door is open, the indoor-air might be polluted so fast. Therefore, it is necessary to make a counter plan about the method of ventilation and amount of ventilation to keep the indoor aerial environment agreeable. 2) It is urgent to conceive countermeasure against engine noise because the noise level of all rooms exceeds 60dB, which is regulation of noise for protecting crew established in ship's classification, during the sailing. 3) State cabin and Guest cabin are super cooled by operating air conditioner exceeding agreeableness extent and it is needed to prevent them.

Experimental Study on the Airside Performance of Aluminum Heat Exchangers Having Slim Louver Fins (슬림형 루버 핀이 장착된 알루미늄 열교환기의 공기측 전열 성능에 대한 실험적 연구)

  • Kim, Nae-Hyun;Cho, Honggi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.9
    • /
    • pp.587-595
    • /
    • 2017
  • Recent trends in slim air conditioners require heat exchangers of reduced flow depth. In this study, slim louver fin geometry was obtained using predictive correlations. The deduced geometry yielded 10 mm flow depth, 0.9 mm louver pitch, and $35^{\circ}$ louver angle. Samples were made and tests were conducted. The new slim sample yielded 36% higher j factor and 2.3% higher f factor compared with those of the standard sample. This implies that 26% reduction of heat exchanger volume was possible by reducing the flow depth. In addition, the $j/f^{1/3}$ of the slim sample was 55% larger than that of the standard sample. Furthermore, the results are compared with predictions made using existing correlations.

Study on Ventilation Efficiency of a Mechanically Ventilated Broiler House­(I)Summer Season (강제환기식 육계사내의 환기효율성 조사연구­(I)하절기)

  • 이인복;정문성;유병기;전종기;김경원;이승기
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.103-112
    • /
    • 2003
  • In this study, the distributions of internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were systematically measured at a mechanically ventilated broiler houses during summer season, with local weather data. The analysis was focused on the suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens and decrease of productivity In the mechanically ventilated broiler house, the difference between measured and recommended air temperatures(suitability) was 10.4C in maximum during the summer time. The difference of air temperature in the house between day and night was $8.7^{\circ}C$ in maximum. And maximal hourly range of internal air temperature at 0.4m height from the floor was $3.7^{\circ}C$ suggesting it maintained thermal uniformity in the broiler house. The $NH_3$ and dust concentrations were pretty low because ventilation was fully performed. The air speed at chicken location was measured 2.2m/s and 1.7m/s, respectively without and with chicken existence.

  • PDF

Difference in Patient's Work of Breathing Between Pressure-Controlled Ventilation with Decelerating Flow and Volume-Controlled Ventilation with Constant Flow during Assisted Ventilation (보조환기양식으로서 감속형유량의 압력-조절환기와 일정형유량의 용적-조절환기에서 환자의 호흡일의 차이)

  • Kim, Ho-Cheol;Park, Sang-Jun;Park, Jung-Woong;Suh, Gee-Young;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.803-810
    • /
    • 1999
  • Background : The patient's work of breathing(WOBp) during assisted ventilation may vary according to many factors including ventilatory demand of the patients and applied ventilatory setting by the physician. Pressure-controlled ventilation(PCV) which delivers gas with decelerating flow may better meet patients' demand to improve patient-ventilator synchrony compared with volume-controlled ventilation(VCV) with constant flow. This study was conducted to compare the difference in WOBp in two assisted modes of ventilation, PCV and VCV with constant flow. Methods : Ten patients with respiratory failure were included in this study. Initially, the patients were placed on VCV with constant flow at low tidal volume($V_{T,\;LOW}$)(6-8 ml/kg) or high tidal volume($V_{T,\;HIGH}$)(10-12 ml/kg). After a 15 minute stabilization period, VCV with constant flow was switched to PCV and pressure was adjusted to maintain the same tidal volume($V_T$) received on VCV. Other ventilator settings were kept constant. Before changing the ventilatory mode, WOBp, $V_T$, minute ventilation($V_E$), respiratory rate(RR), peak airway pressure (Ppeak), peak inspiratory flow rate(PIFR) and pressure-time product(PTP) were measured. Results : The mean $V_E$ and RR were not different between PCV and VCV during the study period. The Ppeak was significantly lower in PCV than in VCV during $V_{T,\;HIGH}$. HIGH ventilation(p<0.05). PIFR was significantly higher in PCV than in VCV at both $V_T$ (p<0.05). During $V_{T,\;LOW}$ ventilation, WOBp and PTP in PCV($0.80{\pm}0.37\;J/min$, $164.5{\pm}74.4\;cmH_2O.S$) were significantly lower than in VCV($1.06{\pm}0.39J/mm$, $256.4{\pm}107.5\;cmH_2O.S$)(p<0.05). During $V_{T,\;HIGH}$ ventilation, WOBp and PTP in PCV($0.33{\pm}0.14\;J/min$, $65.7{\pm}26.3\;cmH_2O.S$) were also significantly lower than in VCV($0.40{\pm}0.14\;J/min$, $83.4{\pm}35.1\;cmH_2O.S$)(p<0.05). Conclusion : During assisted ventilation, PCV with decelerating flow was more effective in reducing WOBp than VCV with constant flow. But since individual variability was shown, further studies are needed to confirm these results.

  • PDF

Numerical Study on the Supply and Exhaust Port Size and Fire Management Method in the Semi-transverse Ventilation System for Road Tunnel (도로터널 반횡류환기시스템에서 급배기 포트개도 및 화재시 운영방안에 관한 수치해석적 연구)

  • Ryu, Ji-Oh;Kim, Jin-Su;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.68-74
    • /
    • 2016
  • In semi-transverse ventilation system applied for road tunnel, adjustment of the port opening ratio is an essential part for uniform airflow rate per unit length over the entire tunnel. However, it has not been considered decently throughout the design process and operating of the tunnel. Therefore, in this study, we developed a program for the calculation of the opening size ratio of supply or exhaust port in transverse ventilation system and carried out the research to present a management plan for the port. In supply duct system, the opening size of the port had a tendency to increase and then decrease later when it gradually becomes closer toward the bulkhead at the beginning of the duct the minimum opening degree is to appeared as 56%. In the exhaust system, port size is the smallest at the beginning of duct as 15%, has shown a tendency to increase towards the bulk head. As results of estimating the air flow rate for 300 m intervals, the exhaust flow rate in the center of tunnel appeared to be extremely low as 8.1% and 12.5% when port size is constant and is adjusted supply type. Thus, even if the normal ventilation efficiency is declines, yet it is highly recommend adjusting the port size in order to obtain a uniform flow rate at fire accidents.