• Title/Summary/Keyword: 필러

Search Result 330, Processing Time 0.028 seconds

AN EXPERIMENTAL STUDY ON THE TENSILE STRENGTH OF POSTERIOR RESIN-BASED COMPOSITES (구치부 복합레진의 인장강도에 관한 실험적 연구)

  • Kim, Jae-Gon;Lee, Yong-Hee;Yang, Cheol-Hee;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.464-470
    • /
    • 2001
  • The purpose of this study was to evaluate the tensile strength of light-cured restorative posterior resin-based composites. Five commercially available light-cured composites(Denfil : DF, P60 : PS, Unifil S : US, Z100 : ZH, Z250 : ZT) were used. Rectangular tension test specimens were fabricated in a teflon mold giving 5mm in gauge length and 2mm in thickness. Specimens were subjected to the 5,000 thermal cycles between $5^{\circ}C$ and $55^{\circ}C$ and the immersion time in each bath was 15 second per cycle. Tensile testing was carried out with Instron at a crosshead speed of 0.5mm/min and fractured surface were observed with scanning electron microscope. The obtained results were summarized as follows; 1. The tensile strength of PS was highest. PS was significantly higher than DF, US and ZH(p<0.05) but in the case of ZT was similar to PS(p>0.05). 2. The tensile strength DF was lowest. DF was significantly lower than PS, US, ZH and ZT(p<0.05). 3. The tensile strength of US and ZH were significantly lower than PS and ZT(p<0.05). but were significantly higher than DF(p<0.05). The tensile strength of US and ZH were similar(p>0.05).

  • PDF

Effect of Fluoride Recharging on Fluoride Release and Surface Properties of Orthodontic Bracket Adhesives (불소 적용 후 교정용 브라켓 접착제 종류에 따른 불소 재흡수성과 표면 변화에 관한 연구)

  • Byeon, Seon Mi
    • Journal of dental hygiene science
    • /
    • v.18 no.4
    • /
    • pp.218-226
    • /
    • 2018
  • The aim of this study was to compare fluoride release and surface changes according to different orthodontic bracket adhesives the application of fluoride products. We used non-fluoridated composite resin Transbond fluoridated composite resins Blugloo and LightBond, resin-modified glass ionomer Rely $X^{TM}$ Luting 2, and conventional glass ionomer Fuji $I^{(R)}$. Fluoride release of five orthodontic bracket adhesives and fluoride release ability after application of three fluoride products (1.23% acidulated phosphate fluoride gel, Tooth Mousse $Plus^{(R)}$, Fluor Protector, and a toothbrush with sodium fluoride-containing toothpaste) were measured using a fluoride electrode that was connected to an ion analyzer. After 4 weeks of fluoride application, the surface roughness and surface morphology were examined using a surface roughness tester and field emission scanning electron microscopy. The amounts of fluoride release were observed not only on application of Tooth Mousse $Plus^{(R)}$ and Fluor Protector on resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$, but also during tooth brushing using fluoride-containing toothpaste. After application of Tooth Mousse $Plus^{(R)}$, except Transbond XT, the surface roughness increased, and all orthodontic adhesives showed a partial drop of micro-particle filler. On application of 1.23% acidulated phosphate fluoride gel on all orthodontic bracket adhesives, their surface roughness increased. To bond the orthodontic bracket, resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$ adhesives are highly recommended if the amount of fluoride release is considered to confer a preventative effect on dental caries, and among the fluoride products, Tooth Mousse $Plus^{(R)}$ and Fluor Protector are better than 1.23% acidulated phosphate fluoride gel, and these are expected to prevent dental caries even during tooth brushing with fluoride-containing toothpaste.

HYDROLYTIC DEGRADATION OF POSTERIOR RESIN RESTORATIVE MATERIALS (구치부 레진 수복 재료의 가수분해)

  • Yang, Kuy-Ho;Park, Mi-Ran;Choi, Nam-Ki;Park, Eun-Hae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.673-682
    • /
    • 2001
  • The use of resin composites has continued to increase over the last several years. In spite of their growing popularity, composites continue to exhibit a number of undesirable characteristics. One of the major deficiencies of composite restorative resins is their inadequate resistance to wear. Of the multitude of factors that have been associated with wear, subsurface degradation within the restoration is considered to be one. The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. This solution with a high concentration of hydroxyl ions is a convenient medium for accelerated degradation of silane coupling and filler particles. The brands studies were Definite($Degussa-H\ddot{u}ls$ AG, Germany), Prodigy(Kerr, USA), Pyramid(Bisco, USA) and Synergy(Coltene, Swiss). Preweighed discs of each brand were exposed to 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters : (a) mass loss(%)-determined from pre-and post-exposed specimen weights : (b) Si loss(ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation $depth({\mu}m)$-measured microscopically (SEM) from polished circular sections of exposed specimens. The results were follows: 1. Mass loss of Synergy was $1.24{\pm}0.002%$, it was the highest, there was no significant difference among the materials. 2. The degree of degradation layer depth of Synergy was $107.83{\pm}2.52{\mu}m$, it was the highest, there was no significant difference among any other materials than Synergy. 3. There was no difference among the four materials in Si loss. 4. The correlation coefficient between mass loss and degradation depth was relatively high(r=0.06, p<0.05). 5. There was no coefficient correlation between Si loss and mass loss, the degree of degradation layer depth and Si loss. 6. When observed with SEM, destruction of bonding is observed between resin matrix and filler.

  • PDF

A Experimental Study on the Material Charateristics of Crushed Aggregate Produced in Quarry (석산에서 생산되는 부순골재의 재료 특성에 관한 연구)

  • Baek Dong-Il;Youm Chi-Sun;Kim Myung-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.569-579
    • /
    • 2005
  • An investigation for long-term strength characteristics of crushed sand concrete using crushed sands produced in Yang-san, Kim-hae and Jin-hae that can be assumed to respectively represent eastern, middle and western suburbs of Busan has been carried out. Concrete is composed of 70~80% of aggregates in whole volume so the effect of aggregates quality to the characteristics of concrete is very important. Since 1980s, aggregates used in concrete have already been substituted crushed stone because of the exhaustion of natural gravel and sand. Crushed sand tends to increase in using quantity because of the prohibition of sea sand picking and deterioration of river sand. Crushed sand is blended with river sand in order to investigate the quality changes and characteristics of concrete as variation of blend ratio of crushed sand (n, 50, 70, 80, 90, 100%). Slump and air content were measured to investigate the properties of fresh concrete. Unit weight, compressive strength and modulus of elasticity in age of 7, 28, 60, n, 180 days were measured to investigate properties of hardened concrete. Compressive strength, unit weight and modulus of elasticity were increased with a passage of time and they are expected to keep on increasing in long-term age as well. The experimental results of the qualifies of crushed aggregates in each producing area, were all satisfied with Korea Standard. The results of the measurement of slump exposed that slump preferably decreased as mixing rate increased till 70~80% but it increased to mixing rate 70~80%. The air content was exposed that it decreased by micro filler phenomenon according to that crushed sand b)ended ratio increased. According to the result of measuring unit weight in age of 7, 28, 60, 90, 180days, it increased in accordance with that blended ratio of crushed aggregates increases. As a result of measuring compressive strength and modulus of elasticity in age of 7, 28, 50, 90, 180days, compressive strength was highest when it is 70% of blended ratio.

Facial Expression Control of 3D Avatar using Motion Data (모션 데이터를 이용한 3차원 아바타 얼굴 표정 제어)

  • Kim Sung-Ho;Jung Moon-Ryul
    • The KIPS Transactions:PartA
    • /
    • v.11A no.5
    • /
    • pp.383-390
    • /
    • 2004
  • This paper propose a method that controls facial expression of 3D avatar by having the user select a sequence of facial expressions in the space of facial expressions. And we setup its system. The space of expression is created from about 2400 frames consist of motion captured data of facial expressions. To represent the state of each expression, we use the distance matrix that represents the distances between pairs of feature points on the face. The set of distance matrices is used as the space of expressions. But this space is not such a space where one state can go to another state via the straight trajectory between them. We derive trajectories between two states from the captured set of expressions in an approximate manner. First, two states are regarded adjacent if the distance between their distance matrices is below a given threshold. Any two states are considered to have a trajectory between them If there is a sequence of adjacent states between them. It is assumed . that one states goes to another state via the shortest trajectory between them. The shortest trajectories are found by dynamic programming. The space of facial expressions, as the set of distance matrices, is multidimensional. Facial expression of 3D avatar Is controled in real time as the user navigates the space. To help this process, we visualized the space of expressions in 2D space by using the multidimensional scaling(MDS). To see how effective this system is, we had users control facial expressions of 3D avatar by using the system. As a result of that, users estimate that system is very useful to control facial expression of 3D avatar in real-time.

Research Trend of Biomass-Derived Engineering Plastics (바이오매스 기반 엔지니어링 플라스틱 연구 동향)

  • Jeon, Hyeonyeol;Koo, Jun Mo;Park, Seul-A;Kim, Seon-Mi;Jegal, Jonggeon;Cha, Hyun Gil;Oh, Dongyeop X.;Hwang, Sung Yeon;Park, Jeyoung
    • Applied Chemistry for Engineering
    • /
    • v.31 no.2
    • /
    • pp.115-124
    • /
    • 2020
  • Sustainable plastics can be mainly categorized into (1) biodegradable plastics decomposed into water and carbon dioxide after use, and (2) biomass-derived plastics possessing the carbon neutrality by utilizing raw materials converted from atmospheric carbon dioxide to biomass. Recently, biomass-derived engineering plastics (EP) and natural nanofiber-reinforced nanocomposites are emerging as a new direction of the industry. In addition to the eco-friendliness of natural resources, these materials are competitive over petroleum-based plastics in the high value-added plastics market. Polyesters and polycarbonates synthesized from isosorbide and 2,5-furandicarboxylic acid, which are representative biomass-derived monomers, are at the forefront of industrialization due to their higher transparency, mechanical properties, thermal stability, and gas barrier properties. Moreover, isosorbide has potential to be applied to super EP material with continuous service temperature over 150 ℃. In situ polymerization utilizing surface hydrophilicity and multi-functionality of natural nanofibers such as nanocellulose and nanochitin achieves remarkable improvements of mechanical properties with the minimal dose of nanofillers. Biomass-derived tough-plastics covered in this review are expected to replace petroleum-based plastics by satisfying the carbon neutrality required by the environment, the high functionality by the consumer, and the accessibility by the industry.

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.

Surface Roughness and Cariogenic Microbial Adhesion after Polishing of Smart Chromatic Technology-based Composite Resin (Smart Chromatic Technology 기반 복합 레진의 폴리싱 이후 표면 거칠기 및 우식원성 미생물 부착 )

  • Haesong Kim;Juhyun Lee;Haeni Kim;Howon Park
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.65-74
    • /
    • 2023
  • This study compared the surface roughness and microbial adhesion characteristics of Omnichroma, a novel composite resin developed using "smart chromatic technology", with those of two other conventional composite resins with different filler compositions. A total of 144 specimens were fabricated using 3 types of composite resins: Omnichroma (nano-spherical), Filtek Z350XT (nanofill), and Tetric N-Ceram (nanohybrid) and, divided into 3 groups of 48. Finishing was performed using tungsten carbide burs. Specimens were then divided into 3 subgroups using different polishing methods: Control, SofLex, and PoGo. Surface roughness was analyzed quantitatively and qualitatively using an atomic force microscope and a scanning electron microscope. Microbial adhesion was assessed by culturing Streptococcus mutans on the specimens for 24 hours and then measuring colony-forming units attached to the upper surface. The surface roughness (Ra) of Omnichroma was 0.123 ㎛ after finishing, and it exhibited a smooth surface compared to the other resins. However, after polishing, there were no significant differences in the surface roughness between the three composite groups, regardless of the polishing methods. The surfaces of the Control subgroups were significantly rougher than those of the SofLex subgroups in all 3 composite groups. However, except for Tetric N-Ceram, there were no significant differences between the Control and PoGo subgroups in the other composite groups. Microbial adhesion assessment showed no significant differences between any of the 3 composite resin subgroups; however, Omnichroma exhibited higher microbial adhesion than the other two composites. No significant correlation was observed between surface roughness and microbial adhesion.

Effect of surface sealant on surface roughness of dental composite with different surface roughness (서로 다른 거칠기의 복합레진에 표면 강화제 도포시 표면 거칠기의 변화)

  • Dong-Ah Shin;Seon-Ju Jin;Kkot-Byeol Bae;In-Nam Hwang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.195-203
    • /
    • 2023
  • Purpose: This study aimed to evaluate the influence of surface sealants on the surface roughness of composite resins. Materials and Methods: The study used microfilled composite resin (Metafil CX, Sun Medical Co.) and hybrid composite resin (AeliteTM LS posterior, Bisco). Sixty specimens (8 mm in diameter and 4 mm in height) of each composite resin type were prepared and divided into 3 groups. Each specimen was ground with 600, 1000, and 2000-grit sandpaper. The Surface roughness (Ra) values were measured using a surface roughness tester (SJ-301, Mytutoyo) before and after surface sealant application. Surface sealants, BisCoverTM LV (Bisco), Optiguard® (Kerr), and Seal-n-ShineTM (Pulpdent), were applied to the specimens, as instructed and observed by scanning electron microscope (JSM-7500, JEOL) and atomic force microscope (MultiMode IV, Veeco Instruments). Results: Specimens ground with 600-grit sandpaper coated with surface sealants exhibited significantly lower Ra values than the untreated group (P < 0.05). Specimens ground with 1000 and 2000-grit sandpaper showed statistically no difference. There was no significant difference in surface roughness among BisCoverTM LV, Optiguard®, and Seal-n-ShineTM. SEM and AFM revealed remarkably decreased microdefects on the surfaces of composite resins after surface sealant application. Conclusion: Surface sealants can influence surface roughness when applied on the rough surface of composite resins but not on highly polished composite resins.

SURFACE ROUGHNESS OF COMPOSITE RESIN ACCORDING TO FINISHING METHODS (복합레진 표면의 연마방법에 따른 표면조도)

  • Min, Jeong-Bum;Cho, Kong-Chul;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.138-150
    • /
    • 2007
  • The purpose of this study was to evaluate the difference of surface roughness of composite resin according to composite resin type, polishing methods, and use of resin sealant. Two hundred rectangular specimens, sized $8{\times}3{\times}2mm$, were made of Micro-new (Bisco, Inc., Schaumburg, IL, U.S.A) and Filtek Supreme (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and divided into two groups; Micronew-M group, Filtek Supreme-S group. Specimens for each composite group were subdivided into five groups by finishing and polishing instruments used; M1 & S1(polyester strip), M2 & S2 (Sof-Lex disc), M3 & S3 (Enhance disc and polishing paste), M4 & S4(Astropol) and M5 & S5 (finishing bur), Polished groups were added letter B after the application of resin surface sealant (Biscover), eg, M1B and S1B. After specimens were stored with distilled water for 24hr, average surface roughness (Ra) was taken using a surface roughness tester. Representative specimens of each group were examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using paired t-test, ANOVA and Duncan's tests at the 0.05 probability level. The results of this study were as follows ; 1. The lowest Ra was achieved in all groups using polyester strip and the highest Ra was achieved in M5, S5 and M5B groups using finishing bur. On FE-SEM, M1 and S1 groups provided the smoothest surfaces, M5 and S5 groups were presented the roughest surfaces and voids by debonding of filler on the polished specimens. 2. There was no significant difference in Ra between Micronew and Filtek Supreme before the application of resin sealant, but Micronew was smoother than Filek Supreme after the application of resin sealant. 3. There was significant corelation between Ra of type of composite resin and polishing methods before the application of resin sealant (p=0.000), but no significant interaction between them after the application of resin sealant. On FE-SEM, most of composite resin surfaces were smooth after the application of resin sealant on the polished specimens. 4. Compared with before and after the application of resin sealant in group treated in the same composite and polishing methods, Ra of M4B and M5B was statistically lower than that of M4 and M5, and S5B was lower than that of S5, respectively (p<0.05). In conclusion, surface roughness by polishing instruments was different according to type of composite resin. Overall, polyester strip produced the smoothest surface, but finishing bur produced the roughest surface. Application of resin sealant provided the smooth surfaces in specimens polished with Enhance, Astropol and finishing bur, but not provided them in specimens polished with Sof-Lex disc.