• Title/Summary/Keyword: 피해분석

Search Result 5,935, Processing Time 0.031 seconds

An Experimental Study on Ground Reinforcement Effect of Concrete and Expansion Mat for Prevention of Buried Pipe Damage (지중매설관 손상 방지를 위한 콘크리트매트와 팽창매트의 지반보강효과에 관한 실험적 연구)

  • Park, Jeong-Jun;Shin, Heesoo;Yuu, Jungjo;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.1
    • /
    • pp.91-101
    • /
    • 2019
  • Recently, small-scale excavation like ground cavity restoration and buried pipe replacement works are being carried out in urban area, in order to improve living convenience. This paper describes experiment results on the ground reinforcement method that can reduce the buried pipe damage, when the differential settlement occurred due to poor compaction of ground below the buried pipe. Plate load tests were conducted to evaluate a reinforcement effect of ground using concrete mat and expansion mat in the ground below the buried pipe. The results showed that the stress reduction ratio by concrete mat and expansion mat according to the surcharge load was about 46%~48% and 39%~42%, respectively. Therefore, the differential settlement of the buried pipe and the ground deformation below the buried pipes were reduced by the reinforcement effect of the concrete mat and expansion mat. This means that it is possible to prevent a buried pipe damage due to underground cavity and ground subsidence, if concrete mat and expansion mat are reinforced in the ground below the buried pipe or on the ground between the buried pipes.

Threshold Condition for Exclusion of Riprap into Bypass Pipe (저층수 배출관에 유입된 사석의 배제 한계조건)

  • Jeong, Seokil;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.1
    • /
    • pp.57-66
    • /
    • 2019
  • One of the most serious problems with concrete small dams or barriers installed in small/median rivers is the deposit of sediments, especially, in Korea. An effective way to discharge such sediments to downstream is to construct a bypass pipe under the river bed. However, efficiency may become lowered if ripraps are entered into the bypass pipe. Therefore, in this study, we derived the threshold condition for the exclusion of ripraps from the bypass pipe using 3D numerical analysis. Upstream flow of the small dam was assumed to be stationary, and the energy concept was applied to the control volume containing the bypass pipe and its periphery. As a result, when the ratio of the water level difference between upstream and downstream to the diameter of the riprap was approximately equal to 1.2, the threshold condition for exclusion of the stones or riprap from the bypass pipe was affirmatively determined. If the characteristics of the adsorptive sediment adversely affecting the river environment in the future would be taken into account, results from this study are expected to put to practical use in the management of concrete small dam with bypass pipe system.

Analysis of Affecting Factors on Exposure Assessment Errors and Characteristics of Applicants for Damage by Usage of Humidifier Disinfectants (가습기살균제 사용에 따른 피해 신청자들의 특성 및 노출평가 오류 영향요인 분석)

  • Ryu, Hyeonsu;Jo, EunKyung;Choi, Yoon-Hyeong;Lee, Seula;Yoon, Jeonggyo;Kwak, Jung Hyun;Park, Jinhyeon;Heo, Jung;Kim, Pan-Gyi;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.1
    • /
    • pp.71-81
    • /
    • 2019
  • Objectives: The lung injuries by exposure to the humidifier disinfectants (HDs) were reported in 2011, Korea. For the HD victims, environmental exposure level and clinical diagnosis were conducted to determine the levels of damage by HDs. Methods: The exposure assessment to the HDs from 1st to 4th questionnaire surveys were carried out for 5,245 victims. And the affecting factors of exposure levels were analyzed by characterizing exposure and demographic information. By using of exposure concentration and cumulative time, exposure levels were classified and compared by percentage of clinical diagnosis classes. The high exposure and low clinical diagnosis rating groups, and low exposure and high clinical diagnosis rating groups were analyzed to overcome the limitation of past exposure assessment such as recall bias. Results: Among the all applicants damaged by the humidifier disinfectants, survivors were 4,028 and the dead were 1,217. And male and female were 2,675, and 2,547, respectively. In case of occurrence age of lung disease, under 10 years was majority age group (1,536) and followed by thirties (917). Pregnant women and fetuses were 339 and 439, respectively. And the damages by exposure to the HDs were concentrated on these susceptible populations in groups with low exposure and high clinical diagnosis rating. On the other hand, the groups classified by high exposure and low clinical diagnosis rating were shown different characterization. Conclusions: The questionnaire survey on past exposure may be uncertain due to recall bias. However, the relationship between classified exposure levels and clinical diagnosis ratings might be shown positive correlation if the exposure assessment errors were analyzed and controlled.

Experimental Assessment and Specimen Height Effect in Frost Heave Testing Apparatus (동상시험장비의 실험적 검증 및 시료크기의 영향에 관한 연구)

  • Jin, Hyunwoo;Ryu, Byunghyun;Lee, Jangguen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Frost heave is one of the representative engineering characteristics in cold regions. In South Korea, which is located in seasonal frost area, structural damage caused by frost heave and thaw happens and the need for research on the frost heave is increasing. In this paper, newly developed transparent temperature-controllable cell is used to focus on the frost heave. Frost susceptible artificial soil is used to analyze water intake rate which is one of the important factors in frost susceptibility criteria. Frost heave rate and water intake rate have similar behavior after heave by freezing of pore water converges. O-ring installed in the upper pedestal to measure water intake rate generates side friction between the inner wall of the freezing cell and O-ring, thereby hindering frost heave. Therefore, the frost susceptibility criteria using the water intake rate is not reliable. It is appropriate to use frost heave rate which has similar behavior with water intake rate. Frost heave tests were performed under two different specimen heights. Overburden pressure, temperature gradient and dry unit weight were set under similar state. Based on laboratory testing results, frost heave is independent on the specimen height.

Evoked Potentials before the Intractable Epilepsy Surgery (난치성 뇌전증 환자에서 수술 전 유발전위검사)

  • Lim, Sung Hyuk;Park, Sang Ku;Baek, Jae Seung;Kim, Kab Kyu;Kim, Ki Eob;Lee, Yu Ji
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.198-204
    • /
    • 2019
  • Various treatments can be attempted in patients with intractable epilepsy, in whom the symptoms of seizures are not controlled by various drugs. On the other hand, in patients requiring a surgical method, a preoperative examination is needed to determine the portion of seizure site to be resected. Electrodes are inserted into the cerebral cortex for accurate lesion measurements and safe operation. The electrodes inserted in the cortex not only record the electroencephalography (EEG), but also allow various tests to confirm the function of the part. One of these methods is the evoked potential test. From January 2015 to December 2018, the trends of measured waveforms in were analyzed 70 patients. The somatosensory evoked potential (SSEP) recorded on the electrode inserted in the cerebral cortex can be searched for the pathway of the central sulcus to avoid the primary motor area and primary sensory area. In addition, using the middle latency auditory evoked potentials (MLAEP) and flash visual evoked potentials (FVEP), the functional cortex in the auditory cortex and the visual cortex were compared with the seizure focus point on the EEG to help determine the location of the ablation and minimize functional impairment after surgery.

A Case Study on Earthquake-induced Deformation of Quay Wall and Backfill in Pohang by 2D-Effective Stress Analysis (2차원 유효응력 해석에 의한 지진시 포항 안벽구조물의 변형 사례 분석)

  • Kim, Seungjong;Hwang, Woong-Ki;Kim, Tae-Hyung;Kang, Gi-Chun
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.7
    • /
    • pp.15-27
    • /
    • 2019
  • The purpose of this study is to investigate the mechanism about damages occurring at quay wall and backfill in Youngilman Port during Pohang earthquake (M5.4) on November 15, 2017. In the field investigation, the horizontal displacement of the caisson occurred between 5 cm and 15 cm, and the settlement at backfill occurred higher than 10 cm. 2D-effective Stress Analysis was performed to clarify the mechanism for the damage. The input earthquake motion used acceleration ($3.25m/s^2$) measured at bedrock of Pohang habor. Based on a numerical analysis, it was found that the effective stress decreased due to the increase of excess pore pressure in the backfill ground and the horizontal displacement of the caisson occurred by about 14 cm, and the settlement occurred by about 3 cm. In backfill, the settlements occurred between 6 cm and 9 cm. This is similar to field investigation results. Also, it was found that the backfill soil was close to the Mohr-Coulomb failure line due to the cyclic loading from the effective stress path and the stress-strain behavior. It may be related to decreasing of bearing capacity induced by the reduction of effective stress caused by the increase of the excess pore water pressure.

Enhanced Sound Signal Based Sound-Event Classification (향상된 음향 신호 기반의 음향 이벤트 분류)

  • Choi, Yongju;Lee, Jonguk;Park, Daihee;Chung, Yongwha
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.5
    • /
    • pp.193-204
    • /
    • 2019
  • The explosion of data due to the improvement of sensor technology and computing performance has become the basis for analyzing the situation in the industrial fields, and various attempts to detect events based on such data are increasing recently. In particular, sound signals collected from sensors are used as important information to classify events in various application fields as an advantage of efficiently collecting field information at a relatively low cost. However, the performance of sound-event classification in the field cannot be guaranteed if noise can not be removed. That is, in order to implement a system that can be practically applied, robust performance should be guaranteed even in various noise conditions. In this study, we propose a system that can classify the sound event after generating the enhanced sound signal based on the deep learning algorithm. Especially, to remove noise from the sound signal itself, the enhanced sound data against the noise is generated using SEGAN applied to the GAN with a VAE technique. Then, an end-to-end based sound-event classification system is designed to classify the sound events using the enhanced sound signal as input data of CNN structure without a data conversion process. The performance of the proposed method was verified experimentally using sound data obtained from the industrial field, and the f1 score of 99.29% (railway industry) and 97.80% (livestock industry) was confirmed.

Development of a Gangwon Province Forest Fire Prediction Model using Machine Learning and Sampling (머신러닝과 샘플링을 이용한 강원도 지역 산불발생예측모형 개발)

  • Chae, Kyoung-jae;Lee, Yu-Ri;cho, yong-ju;Park, Ji-Hyun
    • The Journal of Bigdata
    • /
    • v.3 no.2
    • /
    • pp.71-78
    • /
    • 2018
  • The study is based on machine learning techniques to increase the accuracy of the forest fire predictive model. It used 14 years of data from 2003 to 2016 in Gang-won-do where forest fire were the most frequent. To reduce weather data errors, Gang-won-do was divided into nine areas and weather data from each region was used. However, dividing the forest fire forecast model into nine zones would make a large difference between the date of occurrence and the date of not occurring. Imbalance issues can degrade model performance. To address this, several sampling methods were applied. To increase the accuracy of the model, five indices in the Canadian Frost Fire Weather Index (FWI) were used as derived variable. The modeling method used statistical methods for logistic regression and machine learning methods for random forest and xgboost. The selection criteria for each zone's final model were set in consideration of accuracy, sensitivity and specificity, and the prediction of the nine zones resulted in 80 of the 104 fires that occurred, and 7426 of the 9758 non-fires. Overall accuracy was 76.1%.

Experimental study of the air emission effect in the tangential and the multi-stage spiral inlet (접선식 유입구와 다단식 나선 유입구의 공기 배출 효과에 관한 실험적 연구)

  • Seong, Hoje;Rhee, Dong Sop;Park, Inhwan
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.235-243
    • /
    • 2019
  • Recently, urban inundation was frequently occurred due to the intensive rainfall exceeding marginal capacity of the flood control facility. Furthermore, needs for the underground storage facilities to mitigate urban flood are increasing according to rapidly accelerating urbanization. Thus, in this study, drainage efficiency in drain tunnel connecting to underground storage was investigated from the air-core measurements in the drop shaft against two types of inlet structure. In case of the spiral inlet, the multi-stage structure is introduced at the bottom of the inlet to improve the vortex induction effect at low inflow discharge (multi-stage spiral inlet). The average cross-sectional area of the air-core in the multi-stage spiral inlet is 10% larger than the tangential inlet, and show the highly air emission effect and the highly inflow efficiency at the high inflow discharge. In case of the tangential inlets, the air emission effect decreased after exceeding the maximum inflow discharge, which is required to maintain the inherent performance of the tangential inlet. From the measurements, the empirical formula for the cross-sectional area of the air-core according to locations inside the drop shaft was proposed in order to provide the experimental data available for the inlet model used in experiments.

Assessment of the level and identification of airborne molds by the type of water damage in housing in Korea (국내 주택에서 물 피해 유형에 따른 부유곰팡이 농도 수준 평가 및 동정 분석)

  • Lee, Ju Yeong;Hwang, Eun Seol;Lee, Jeong-Sub;Kwon, Myunghee;Chung, Hyen Mi;Seo, SungChul
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.355-361
    • /
    • 2018
  • Mold grows more easily when humidity is higher in indoor spaces, and as such is found more often on wetted areas in housing such as walls, toilets, kitchens, and poorly managed spaces. However, there have been few studies that have specifically assessed the level of mold in the indoor spaces of water-damaged housing in the Republic of Korea. We investigated the levels of airborne mold according to the characteristics of water damage types and explored the correlation between the distribution of mold genera and the characteristics of households. Samplings were performed from January 2016 to June 2018 in 97 housing units with water leakage or condensation, or a history of flooding, and in 61 general housing units in the metropolitan and Busan area, respectively. Airborne mold was collected on MEA (Malt extract agar) at flow rate of 100 L/min for 1 min. After collection, the samples were incubated at $25^{\circ}C$ for 120 hours. The cultured samples were counted and corrected using a positive hole conversion table. The samples were then analyzed by single colony culture, DNA extraction, gene amplification, and sequencing. By type of housing, concentrations of airborne mold were highest in flooded housing, followed by water-leaked or highly condensed housings, and then general housing. In more than 50% of water-damaged housing, the level of airborne mold exceeded the guideline of Korea's Ministry of Environment ($500CFU/m^3$). Of particular concern was the fact that the I/O ratio of water-damaged housing was greater than 1, which could indicate that mold damage may occur indoors. The distribution patterns of the fungal species were as follows: Penicillium spp., Cladosporium spp. (14%), Aspergillus spp. (13%) and Alternaria spp. (3%), but significant differences of their levels in indoor spaces were not found. Our findings indicate that high levels of mold damage were found in housing with water damage, and Aspergillus flavus and Penicillium brevicompactum were more dominant in housing with high water activity. Comprehensive management of flooded or water-damaged housing is necessary to reduce fungal exposure.