• Title/Summary/Keyword: 피크 간섭

Search Result 40, Processing Time 0.03 seconds

Higher Order Spectral Analysis of Non-linear Pitching Motion (고차스펙트럼을 이용한 선체 종동요의 비선형적 거동에 관한 해석)

  • Kang, Byung-Ho;Carlos, Miguel Mejia;Kim, Tae-Ho;Park, Jun-Mo;Kong, Gil-Young
    • Journal of Navigation and Port Research
    • /
    • v.41 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • The estimation of non-linear ship motion is one of the most important issues in recent studies of ship stability. In this paper, bispectral analysis and bicoherence analysis were introduced in order to analyze the non-linear ship motion. In addition to the previously observed non-linear pitching motion in following seas, this study observed the non-linear phase coupling of pitching motion in following & quartering seas, and starboard beam seas. By comparing phase coupling between each frequency quantitatively via the bicoherence analysis, it was confirmed that non-linear phase coupling was much stronger in frequency regions other than the peak frequencies of a power spectrum. Furthermore, it was found out that the results of bicoherence calculation were analagous to each other, although the different normalization methods were applied.

Application of the modified fast fourier transformation weighted with refractive index dispersion far an accurate determination of film thickness (굴절률 분산을 반영한 고속 푸리에 변환 및 막두께 정밀결정)

  • 김상준;김상열
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.266-271
    • /
    • 2003
  • The reflectance spectrum of optical films thicker than a few microns shows an intensity oscillation due to interference. Since the spectral period of the oscillation is inversely related to film thickness, the thickness of an optical film can be determined from the spectral frequency of the oscillation. For rapid data processing, the spectral frequency is obtained by use of a Fast Fourier Transformation technique. The conventional method of applying a Fast Fourier Transformation to the reflectance spectrum versus photon energy is modified so as to clear the ambiguity in choosing the proper effective refractive index value and to prevent the broadening of the Fourier transformed peak due to the refractive index dispersion. This technique of modified Fast Fourier Transformation is suggested by the authors for the first time to their knowledge. From the analysis of the calculated reflectance spectrum of a 30-${\mu}{\textrm}{m}$-thick dielectric film. it is shown to improve the accuracy in determining film thickness by a great amount. The improved accuracy of the modified Fast Fourier Transformation is also confirmed from the analysis of the reflectance spectra of a sample with 80-${\mu}{\textrm}{m}$-thick cover layer and 13-${\mu}{\textrm}{m}$-thick spacer layer on a PC substrate.

A Study on Cross-correlation Control Schemes on Walsh and Golay Codes Based on the Orthogonal Transformation and BER Performance Evaluation of Asynchronous CDMA System Using the Modified Codes (직교변환에 의한 Walsh 및 Golay 코드의 상호상관 제어방식과 수정된 코드를 사용한 비동기 CDMA 시스템의 비트오율 성능에 관한 연구)

  • Lee, Won-Chang;Kim, Myoung-Jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.304-312
    • /
    • 2008
  • Orthogonal codes like Walsh and Golay codes may have large correlation value when they are not synchronized, hence they are seldom used in asynchronous CDMA systems. Wysocki[1] showed that by multiplying the original Walsh-Hadamard matrix with an orthogonal transformation matrix the resultant matrix sustains orthogonality between row vectors and their cross-correlation can be reduced. Soberly and Wysocki[2] proposed similar scheme on Golay codes. This implies that using the proper orthogonal transformation cross-correlation of Walsh and Golay codes can be reduced, and the transformed codes can be used for user separation in the CDAM reverse link. In this paper we discuss cross-correlation related parameters which affect the performance of an asynchronous CDMA link, and we investigate the correlation properties of the transformed codes. When we designed orthogonal transformation matrices for Walsh and Golay codes, we minimized the maximum value of aperiodic cross-correlation of the codes ($ACC_{max}$) or the mean square value of the aperiodic cross-correlation($R_{cc}$) with preserving the orthogonality of the modified codes. We also evaluate the asynchronous CDMA system that uses the transformed Walsh and Golay codes.

  • PDF

Trend Analysis of Labor Input Ratios by Work Types in Apartment Housing Constructions (공동주택 건설공사에서 공종별 실투입 노무비율의 추이분석)

  • Jeon, Sang-Hoon;Koo, Kyo-Jin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.5
    • /
    • pp.97-104
    • /
    • 2015
  • Apartment Housing 25 in the field of construction since 2000 collected by types of labor: reinforced concrete, plaster, internal, equipment, electrics communication, the other work. And the performance of labor input was collected in the amount of construction work performed on a monthly basis. After changing the construction period in the standardization work that is 100% of the construction period, the amount was converted into labor ratio by type. Analysis of the input flow rate and the amount of labor conclusions were as follows: (1) The size of the labor rate is reinforced concrete work (38.25%), plastering work (5.10%), internal work (5.67%), equipment work (9.10%), electrics communication (8.76%), the other works (33.12%) and the size of labor rate is the largest work in reinforced concrete work. (2) The peak of labor input ratio was from 52.5% month to 62.5% month. This was when the labor rate of 3.6%. (3) The period month of the largest labor ratio% is 35% month by reinforced concrete construction, and this time it was 2.12% per month labor rate, and reinforced concrete construction is finishing from 65% month to 80% month. This showed the greatest congestion of mutual interference between each works is being continue. The results of this study are the greatest congestion in apartment housing construction has informed the high period(%months), which is essential to a successful project.

Studies on Standardization of Licorice Based on Its Active Components with On-line HPLC Bioassay System (실시간 활성시스템을 접목한 감초의 유효성분에 대한 표준화 연구)

  • Hong, Jae Seung;Kang, Bum Gu;Jang, Young Soo;Kim, Seon Ha;Wang, Zhiqiang;Park, Yoon Ha;Park, Jong Hyuk;Lim, Soon Sung
    • Korean Journal of Plant Resources
    • /
    • v.27 no.5
    • /
    • pp.401-414
    • /
    • 2014
  • In an attempt to evaluate licorice quality based on its biological activity, we grafted an on-line high-performance liquid chromatography (HPLC) bioassay method into the previously established HPLC analysis method. The common antioxidant peaks in licorices of various origin were observed through an on-line HPLC/DPPH system leading to a decrease in absorbance at 517 nm for 2,2-diphenyl-1-picrylhydrazyl (DPPH). Among them, the licorice from Youngju possessed the highest activity. Therefore, three active standard compounds from the dehydroglyasperin C, dehydroglyasperin D, and isoangustone A, were isolated and elucidated by medium pressure liquid chromatography (MPLC) and instrumental analysis such as nuclear magnetic resonance (NMR), respectively. On-line HPLC/ABTS analysis method with the simultaneous determination of three standard compounds and their radical scavenging activity was established for the quality evaluation of licorices. 2,2'-azinobis-3-ethylbenzothiazoline-6-sulfonic acid radicals (ABTS) which is stable and effective was used in replace of DPPH. The radical scavenging activity of three standards is compared with that of Trolox, known as antioxidant, showing a negative peak with a decrease in absorbance at 734 nm for ABTS. This on-line HPLC/ABTS analysis method was validated for specificity, linearity, precision and accuracy in compliance with international conference on harmonization (ICH) guideline.

Determination of N-nitrosamines in Water by Gas Chromatography Coupled with Electron Impact Ionization Tandem Mass Spectrometry (EI-GC/MS/MS를 이용한 니트로사민류의 수질분석)

  • Lee, Ki-Chang;Park, Jae-Hyung;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.764-770
    • /
    • 2014
  • This study assessed analysis of N-nitrosamines by separation, identification, and quantification using a gas chromatography (GC) mass spectrometer (MS) with electron impact (EI) mode. Samples were pretreated by a automated solid phase extraction (SPE) and a nitrogen concentration technique to detect low concentration ranges. The analysis results by EI-GC/MS (SIM) and EI-GC/MS/MS (MRM) on standard samples with no pretreatment exhibited similar results. On the other hand, the analysis of pretreated samples at low concentrations (i.e. ng/L levels) were not reliable with a EI-GC/MS due to the interferences from impurity peaks. The method detection limits of eight (8) N-nitrosamines by EI-GC/MS/MS analysis ranged from 0.76 to 2.09 ng/L, and the limits of quantification ranged from 2.41 to 6.65 ng/L. The precision and accuracy of the method were evaluated using spiked samples at concentrations of 10, 20 and 100 ng/L. The precision were 1.2~13.6%, and the accuracy were 80.4~121.8%. The $R^2$ of the calibration curves were greater than 0.999. The recovery rates for various environmental samples were evaluated with a surrogate material (NDPA-$d_{14}$) and ranged 86.2~122.3%. Thus, this method can be used to determine low (ng/L) levels of N-nitrosamines in water samples.

Bioanalytical method validation for determination of arsenic speciation in dog plasma using HPLC-ICP/MS (Dog 혈장 중 HPLC-ICP/MS를 이용한 비소 화학종 분석법 검증)

  • Kim, Jong-Hwan;Kwon, Young Sang;Shin, Min-Chul;Kim, Su Jong;Seo, Jong-Su
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.234-241
    • /
    • 2016
  • The approach presented in this article refers to the bioanalytical method validation for the detection and quantitative determination of arsenic species including arsenite (As(III)), arsenate (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) in dog plasma by high-performance liquid chromatography inductively coupled plasma mass spectrometry (HPLC-ICP/MS). The arsenic species were separated using an agilent As speciation column by a mobile phase of 2 mM sodium phosphate monobasic, 0.2 mM ethylenediaminetetraacetic acid disodium salt dehydrate, 10 mM sodium acetate, 3 mM sodium nitrate and 1 % ethyl alcohol at pH 11 (adjusted with 1M NaOH). The method validation experiment was obtained selectivity, linearity, accuracy, precision, matrix effect, recovery, system suitability, dilution integrity and various stabilities. All calibration curves showed good linearity (R2>0.999) within test ranges. The lower limit of quantitation (LLOQ) was 5 ng/mL for As(III), As(V) and DMA, and 20 ng/mL for MMA. The system suitability and dilution values were within 6.5 % and 7.7 %. Subsequently, the developed and validated HPLC-ICP/MS method was also successfully applied to determine the arsenic speciation in dog plasma samples, and the recoveries for the spiked samples were in the range of 91.5–102.2 %. Therefore, this method could be applied to the evaluation of arsenic exposure, health effect assessment and other bio-monitoring studies in biological samples.

Determination of Fission Products in Simulated Nuclear Spent Fuels by Cation.Anion Exchange Chromatography and Inductively Coupled Plasma Atomic Emission Spectrometry (양.음이온교환 크로마토그래피와 유도결합플라스마 원자방출분광법을 이용한 모의 사용후핵연료 중 핵분열생성물 분석)

  • Choi, Kwang Soon;Sohn, Se Chul;Pyo, Hyung Yeol;Suh, Moo Yul;Kim, Do Yang;Park, Yang Soon;Jee, Kwang Yong
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.446-452
    • /
    • 2000
  • The simulated nuclear spent fuel (SIMFUEL) containing the platinum group elements which will not be dissolved in a nitric acid was completely dissolved with a acid digestion bomb. The metallic elements separated in the SIMFUEL were measured by inductively coupled plasma atomic emission spectrometry (ICP-AES). Because the peaks of metallic elements were spectrally interfered by uranium spectrum, uranium and metallic elements were separated by cation exchange resin for Mo, Pd, Rh and Ru and by anion exchange resin for Ba, Ce, La, Nd, Rh, Sr, Y and Zr, respectively. The recovery of Mo, Pd, Rh and Ru after separation by cation exchange chromatography found to be 99-103% and anion exchange separation showed 96.5-107% of recovery except Y with the simulated solution whose concentration was similar to the spent nuclear fuel. The relative standard deviation of this method showed 1.3-6.7% in the SIMFUEL whose concentrations of metallic elements were between several $10^2-10^3$ppm.

  • PDF

A Full Scale Hydrodynamic Simulation of High Explosion Performance for Pyrotechnic Device (파이로테크닉 장치의 고폭 폭발성능 정밀 하이드로다이나믹 해석)

  • Kim, Bohoon;Yoh, Jai-ick
    • Journal of the Korea Society for Simulation
    • /
    • v.28 no.2
    • /
    • pp.1-14
    • /
    • 2019
  • A full scale hydrodynamic simulation that requires an accurate reproduction of shock-induced detonation was conducted for design of an energetic component system. A detailed hydrodynamic analysis SW was developed to validate the reactive flow model for predicting the shock propagation in a train configuration and to quantify the shock sensitivity of the energetic materials. The pyrotechnic device is composed of four main components, namely a donor unit (HNS+HMX), a bulkhead (STS), an acceptor explosive (RDX), and a propellant (BPN) for gas generation. The pressurized gases generated from the burning propellant were purged into a 10 cc release chamber for study of the inherent oscillatory flow induced by the interferences between shock and rarefaction waves. The pressure fluctuations measured from experiment and calculation were investigated to further validate the peculiar peak at specific characteristic frequency (${\omega}_c=8.3kHz$). In this paper, a step-by-step numerical description of detonation of high explosive components, deflagration of propellant component, and deformation of metal component is given in order to facilitate the proper implementation of the outlined formulation into a shock physics code for a full scale hydrodynamic simulation of the energetic component system.

Modification and Validation of an Analytical Method for Dieckol in Ecklonia Stolonifera Extract (곰피추출물의 지표성분 Dieckol의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Oh, Geon;Jin, Heegu;Oh, Hyun-Ji;Kim, Eunjin;Kim, Jongwook;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.143-148
    • /
    • 2022
  • This study was to investigate an analytical method for determining dieckol content in Ecklonia stolonifera extract. According to the guidelines of International Conference on Harmonization. Method validation was performed by measuring the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of dieckol using high-performance liquid chromatography-photodiode array. The results showed that the correlation coefficient of calibration curve (R2) for dieckol was 0.9997. The LOD and LOQ for dieckol were 0.18 and 0.56 ㎍/mL, respectively. The intra- and inter-day precision values of dieckol were approximately 1.58-4.39% and 1.37-4.64%, respectively. Moreover, intra- and inter-day accuracies of dieckol were approximately 96.91-102.33% and 98.41-105.71%, respectively. Thus, we successfully validated the analytical method for estimating dieckol content in E. stolonifera extract.