• Title/Summary/Keyword: 피크검출

Search Result 316, Processing Time 0.025 seconds

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Reduction of multiple-access interference in coherent optical CDMA systems based on all-optical differential detection (전 광학적인 차동 검출 방법을 이용한 코히런트 시간 광 CDMA 시스템에서의 다중접근 간섭 제거)

  • 김선종;김태영;박철수;박창수
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.229-233
    • /
    • 2004
  • We propose a novel scheme to suppress the multiple-access interference(MAI) in coherent optical CDMA systems. This is based on a differential detection using the dual-control NOLM. For an experimental demonstration, two encoded channels we constructed and decoded. These decoded signals are sent to the dual-control NOLM and a high autocorrelation peak with suppressed MAI at the output of the NOLM is observed. Signal-to-interference ratio is improved by 7 ㏈.

Analytical Determination of Cyanide in Maesil (Prunus mume) Extracts (매실추출제품의 시안화합물 분석법에 관한 연구)

  • Kim, Eun-Jung;Lee, Hwee-Jae;Jang, Jin-Wook;Kim, In-Young;Kim, Do-Hyeong;Kim, Hyun-Ah;Lee, Soo-Min;Jang, Ho-Won;Kim, Sang-Yub;Jang, Young-Mi;Im, Dong-Kil;Lee, Sun-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.130-135
    • /
    • 2010
  • Picrate, enzyme-picrate and instrumental analysis methods using IC (Ion Chromatography) and HPLC (High Performance Liquid Chromatography) were compared for their effectiveness in determining cyanide in extracts of Maesil, which is classified as a harmful substance. First, the picrate method showed the shortest analysis time (about 5 hr). The color of picrate paper changed at 0.01 mg/$200\;mL\;CN^-$. However, it was difficult to detect cyanide from amygdalin of glucosides. Second, we performed a qualitative analysis for total cyanide (free cyanide and cyanide from amygdalin) by the enzyme-picrate method using $\beta$-glucosidase and a quantitative analysis by spectrophotometry. Finally, analysis of cyanide by IC and HPLC required the longest determining time (about 17 hr) as well as pretreatment for each free cyanide and amygdalin. These results suggest that enzyme-picrate is the most effective analysis method for the detection of cyanide in Maesil extracts.

Analysis of Utility Interactive 3KW Photovoltaic Power Conditioning System (계통연계형 3KW 태양광발전 PCS 기술 분석)

  • Cha, Han-Ju;Lee, Sang-Hoey
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.182-184
    • /
    • 2007
  • 이 논문에서는 계통연계형 3KW 태양광 발전 시스템 개발에 필요한 기본적인 요소기술로서 MPPT(Maximum Power Point Tracking), 계통연계를 위한 단상 PLL(Phase Locked Loop), 피크전압검출법과 전류제어기법 등을 살펴보고 이를 시뮬레이션으로 검증하였다. 또한 검증된 기법등을 토대로 3kW 태양광 발전 PCS(Power Conditioning System)에 적용실험을 통해 결과를 확인하였다.

  • PDF

A Peak Detector for Variable Frequency Three-Phase Sinusoidal Signals (가변주파수 3상 정현파 신호의 최대전압 검출기)

  • 김홍렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.210-215
    • /
    • 1999
  • The proposed detector is consists of three-phase sinusoidal signal generator and peak detector. This peak detector can detect the peak voltage value at the state of variable frequency. In experi-ment three-phase sinusoidal signals are generated from D/A converter using IBM PC and deliv-ered to the peak detector. Each signals are squared by multiplier and summed up Peak value is the square root of summed value extracted by square root circuit.

  • PDF

Coincidence Summing Corrections in HPGe Gamma Ray Spectrometry in Marinelli-beakers with Efficiency (효율을 적용한 마리넬리 비이커에서 HPGe 감마선 분광분석법의 동시합성보정)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.557-563
    • /
    • 2018
  • Coincidence summing correction effects are known to be greater as the efficiency of the detector increases and as the distance between the source and the detector increases. A point source($^{60}Co$) was used to vary the distance in the direction of the detector's center axis and in the radial direction to obtain the P/T ratio for Coincidence summing correction calibration. In this study, values for coincidence summing corrected calibration of the values in the central and radial directions were applied to the mixed volume source(450 ml CRM source) to compare the overall peak efficiency change according to P/T with Geant4. In addition, the efficiency obtained from the mapping method is applied to the seaweed, a marine sample, and the compatibility of the P/T ratio with the detector and sample very dose together. The efficiency corrected to 1,836 keV was applied to the energy zone affected by the efficiency of 500 keV and the relative error of the measured and corrected values was well matcched by the 3.2 % peak efficiency correction. As with 450 mL CRM source, the larger the volume, the lower the P/T ratio was by ${\pm}5%$. This is due to the increased scattering of gamma-rays emitted as the source becomes farther away from the detector, and this change in P/T has been confirmed to affect the Coincidence summing corrected peak efficiency.

Development of Signal Processing Circuit for Side-absorber of Dual-mode Compton Camera (이중 모드 컴프턴 카메라의 측면 흡수부 제작을 위한 신호처리회로 개발)

  • Seo, Hee;Park, Jin-Hyung;Park, Jong-Hoon;Kim, Young-Su;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.16-24
    • /
    • 2012
  • In the present study, a gamma-ray detector and associated signal processing circuit was developed for a side-absorber of a dual-mode Compton camera. The gamma-ray detector was made by optically coupling a CsI(Tl) scintillation crystal to a silicon photodiode. The developed signal processing circuit consists of two parts, i.e., the slow part for energy measurement and the fast part for timing measurement. In the fast part, there are three components: (1) fast shaper, (2) leading-edge discriminator, and (3) TTL-to-NIM logic converter. AC coupling configuration between the detector and front-end electronics (FEE) was used. Because the noise properties of FEE can significantly affect the overall performance of the detection system, some design criteria were presented. The performance of the developed system was evaluated in terms of energy and timing resolutions. The evaluated energy resolution was 12.0% and 15.6% FWHM for 662 and 511 keV peaks, respectively. The evaluated timing resolution was 59.0 ns. In the conclusion, the methods to improve the performance were discussed because the developed gamma-ray detection system showed the performance that could be applicable but not satisfactory in Compton camera application.

Motion Energy Analysis using SAD (SAD를 이용한 모션 에너지 분석)

  • Kim, Beom-Seok;Park, Seong-Il;Ko, Young-Hyuk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.615-618
    • /
    • 2007
  • 본 실험을 통하여 연속된 프레임을 갖는 이미지 영상을 히스토그램의 절대값을 이용하여 영상의 모션에너지를 분석하는 방법을 제안한다. 입력되어지는 영상은 그 내용의 흐름에 따라 각각의 프레임마다 다른 모션에너지를 발생하고 모션에너지의 피크값을 검출 할 임계값과 영상의 분할을 통하여 영상내 객체의 이동방향이나 움직임의 강도 등을 파악할 수 있다. 이 모션에너지는 여러 가지로 활용할 수 있으며 실험을 통하여 차량의 주행속도를 자동으로 검출해 낼 수 있었다.

  • PDF

Single-Phase Dynamic Voltage Restorer with a Quasi Z-source Topology (Quasi Z-소스 토폴로지를 갖는 단상 동적 전압 보상기)

  • Lee, Ki-Taeg;Jung, Young-Gook;Lim, Young-Cheol;Kim, Kwang-Heon
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.460-461
    • /
    • 2010
  • 본 논문에서는 Quasi Z-소스 토폴로지의 동적 전압 보상기를 제안한다. 제안된 시스템은 Quasi Z-소스 PWM 교류-교류 컨버터를 기반으로 하고 있고 기존의 Z-소스 교류-교류 컨버터의 장점 역시 가지고 있으면서, 또한 입력 단과 출력 단이 공통 접지이며 연속적인 입력전류(CCM)로 동작하는 특징이 있다. 전원의 Sag와 Swell을 검출하기 위하여 피크치 검출기법이 사용되었으며, 출력전압의 총고조파왜형률 %THD를 분석하였다. 제안된 시스템은 65% 전압 Sag와 30% 전압 Swell이 발생하여도 부족전압과 과전압에 대한 보상을 하였으며, 또한 부하전압을 정격전압의 정현파로 유지 할 수 있었다. 실험결과를 통하여 본 연구의 타당성을 입증하였다.

  • PDF

Wavelength Readout of A Fiber Laser Using Time Delayed Quadrature Sampling (시간지연샘플링을 이용한 광섬유레이저의 파장변화검출)

  • 김종섭;송민호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.3
    • /
    • pp.31-38
    • /
    • 2004
  • The wavelength variation of a scanned fiber laser is analyzed using quadrature sampling technique. By time delayed sampling of a phase modulated Mach-Zender interferometer, the wavelength information can be precisely determined regardless of the nonlinearity in the Fabry-Perot wavelength filter which scanned the fiber laser. A wavelength readout resolution of ~20 pm was obtained at 2 KHz M-Z modulation frequency, and it was shown that the resolution could be improved in case of using an electro-optic phase modulator.