Coincidence Summing Corrections in HPGe Gamma Ray Spectrometry in Marinelli-beakers with Efficiency  

Jang, Eun-Sung (Department of Radiation Oncology Kosin University Gospel Hospital)
Lee, Hyo-Yeong (Department of Radiological Science, Dongeui University)
Publication Information
Journal of the Korean Society of Radiology / v.12, no.5, 2018 , pp. 557-563 More about this Journal
Abstract
Coincidence summing correction effects are known to be greater as the efficiency of the detector increases and as the distance between the source and the detector increases. A point source($^{60}Co$) was used to vary the distance in the direction of the detector's center axis and in the radial direction to obtain the P/T ratio for Coincidence summing correction calibration. In this study, values for coincidence summing corrected calibration of the values in the central and radial directions were applied to the mixed volume source(450 ml CRM source) to compare the overall peak efficiency change according to P/T with Geant4. In addition, the efficiency obtained from the mapping method is applied to the seaweed, a marine sample, and the compatibility of the P/T ratio with the detector and sample very dose together. The efficiency corrected to 1,836 keV was applied to the energy zone affected by the efficiency of 500 keV and the relative error of the measured and corrected values was well matcched by the 3.2 % peak efficiency correction. As with 450 mL CRM source, the larger the volume, the lower the P/T ratio was by ${\pm}5%$. This is due to the increased scattering of gamma-rays emitted as the source becomes farther away from the detector, and this change in P/T has been confirmed to affect the Coincidence summing corrected peak efficiency.
Keywords
Geant4; HPGe; coincidence summing; efficiency;
Citations & Related Records
연도 인용수 순위
  • Reference
1 S. H. Kim, "Evaluation of The Cascade Summing effect for HPGe Detector by Using The Cross Analysis Sample," Journal of Radiation Protection and Research. Vol. 30, No. 2, pp. 103-112, 2005.
2 M. S. Lee, "Study on the cascade summing correction for high efficiency HPGe detector," Journal of Radiation Protection and Research. Vol. 30, No. 3, pp. 107-112, 2005.
3 Giubrone, G., et al. "Calculation of Coincidence Summing Correction Factors for an HPGe detector using GEANT4," Journal of environmental radioactivity, Vol. 158-159, pp. 114-118, 2016.   DOI
4 M. Lee, T. S. Park, J. K. Woo, "Coincidence summing effects in gamma ray spectrometry using a Marinelli beaker," Applied Radiation and Isotopes, Vol. 66, No. 6-7, pp. 799-803. 2008.   DOI
5 M. C. Lepy. "Total efficiency calibration for coincidence summing corrections," Nuclear Instruments and. Methods in Physics Research, Vol. 579, No. 1, pp 284-287, 2007.   DOI
6 C. C. Conti, I. C .P. Salinas, H. Zylberberg, "A detailed procedure to simualte an HPGe detector with MCNP5," Progress in Nuclear Energy, Vol, 66, pp. 35-40, 2013.   DOI
7 C. S. Chaudhury, A. Goswami, et al., "Full energy peak efficiency calibration of HPGe detector for point and extended sources using Monte Carlo code," Journal of Radioanalitical and Nuclear Chemistry, Vol. 287, No. 3, pp. 701-708, 2010.
8 E, Tomarchio, "Coincidence summing correction equations in gamma-ray spectrometry with p-type HPGe detectors," Radiation Physics and Chemistry, Vol. 80, No. 3, pp. 318-323, 2011.   DOI
9 G. Haase, D. Tait, A. Wiechen, "Monte Carlo simulation of several gamma-emitting source and detector arrangments for determining corrections of self-attenuation and coincidence summation in gamma-spectrometry," Nuclear Instruments and. Methods in Physics Research, Vol. A239, No. 3, pp. 483-492, 1993.
10 M.Decombaz, J. J. Gostely, J. P. Lawdermann, "Coincidence summing corrections for extended sources in gamma-ray spectrometry using Monte Carlo simulation," Nuclear Instruments and. Methods in Physics Research, Vol. A312, No. 1-2, pp. 152-159, 1992.
11 R. G. Helmer, R. J. Cek, "Calculation of coincidence summing corrections for a specific small soil sample geometry," Radioactivity Radiochemistry, Vol. 8, No. 1, pp. 18-29, 1997.
12 B. S. Zoran Milosevic, "Coincidence summing correction for point and volume 152Eu sources," Applied Radiation and Isotopes, Vol.107, pp 138-144, 2016.   DOI
13 Laslo J. Nadderd, Dragana J. Jordanov, Molos D. Davidovic, "A new matrix method for calculating coincidence summing effects for gamma spectroscopy," Nuclear Instruments and Method in Physics Research, Vol. 662, No. 1, pp 21-25, 2012.   DOI
14 Yosimune Ogata, Hiroshi Miyahara, Ishiqure Nobuhito, Masashi Ishihara., "Development of the modified sum-peak method and its application," Applied Radiation and Isotopes, Vol. 109, pp. 354-357, 2015.
15 M. J. Safari, H. A. Heidari, "Method for developing HPGe detector model in Monte Carlo simuilation codes," Radiation Measurements, Vol. 88, 2016.
16 Blaauw, Menno, Sjoerd J. Gelsema. "Cascade summing in gamma-ray spectrometry in marinelli-beaker geometries: the third efficiency curve," Nuclear Instruments and Methods in Physicis Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 505, No. 1-2, pp. 311-315, 2003.
17 Y. D. Qingbin, W. Z. Ma, "HPGe detector application on monitoring environmental samples around the accelerator," IPAC, 2016.
18 Keyser, Ronald MRonald M., Susan E. Haywood, and Daniel L. Upp., "Performance of the True Coincidence Correction Method in Gamma Vision," Journal of Radioanalical and Nuclear Chemistry, Vol. 245, No. 4, pp. 185-188, 2000.   DOI
19 McFarland, R. C. "Coincidence Summing Considerations When Using Marinelli-Beaker Geometries in Germanium Gamma-Ray Spectrometry," Radioactivity and Radiochemistry, Vol. 2, No. 3, pp. 72-74, 1991.
20 De Felice, Pierino, et al. "Fast Procedures for coincidence summing correction in Gamma-Ray Spectrometry," Applied Radiation and Isotopes, Vol. 52. No. 3, pp. 745-752, 2000.   DOI
21 Garcia-Torano, Eduardo, Milagros Pozuelo, and Francesc Salvat, "Monte Carlo calculations of coincidence summing corrections for volume sources in gamma-ray spectrometry with Ge detectors," Nuclear Instruments and Methods in Physicis Research Section A: Acclerators, Spectrometers, Detectors and Associated Equipment, Vol. 554, No. 3, pp. 577-583, 2005.
22 Garcia-Talavera, M., et al. "Coincidence summing corrections for the natural decay series in gamma-ray dpectrometry." Applied Radiation anf Isotopes Vol. 54, No. 5, pp. 769-776, 2001.   DOI