• Title/Summary/Keyword: 피크검출

Search Result 316, Processing Time 0.027 seconds

The Tire Damage Classification by Pulse Interval Time Density Function of Ultrasonic Wave Envelope on Driving (주행 중 타이어 손상에 의해 발생하는 초음파 포락선 신호의 펄스 간격 시간밀도함수에 의한 손상 분별)

  • Shin, Seong-Geun;Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.3
    • /
    • pp.41-46
    • /
    • 2011
  • The tire damage classification method is researched by periodicity detection of ultrasonic envelope signals to occur at the driving vehicle tire. Because periodic signals is generated by rotations of the damaged tire, it should convert to pulse for using the density function. After time intervals of pulses are represented by the density function, the dominant periodicity is detected. The threshold to make a pulse is calculated by moving average of envelope signals. The result of time density function in case of one damage material, the first peak's time is equals to tire's rotation period, 162ms and 102ms, about the speed of 50km/h and 80km/h. In case of more than one damage material, the sum of each peak's time is equals to tire's rotation period about the speed.

Determination of Some Inorganic Anions in Saline Water by Ion Chromatography with UV Detection (이온크로마토그래피를 이용한 소금물중의 무기음이온들의 분리정량)

  • Han, Sun Ho;Park, Yang Soon;Park, Soon Dal;Joe, Kih Soo;Eom, Tae Yoon
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.99-104
    • /
    • 1999
  • A stepwise gradient elution with two wavelengths detection was performed for the separation and determination of some anions in saline water. The eight anions such as iodate, bromate, nitrite, bromide, nitrate, chromate, iodide and thiocyanate were successfully separated using AS-7 column and sodium chloride/sodium phosphate buffer solution as an eluant within 40 min. The separation behaviors of anions were studied at various sodium chloride concentrations. The peak shapes of anions of bromate, nitrite, bromide and nitrate gradually broadened as the concentration of sodium chloride increased until 1.0 M in the sample solutions. However, no effect was observed in the peak shapes of chromate, iodide and thiocynate. A good linearity was obtained at the range of ppm(mg/L). The detection limit was proved to be $10-720{\mu}g/L$ for the eight anions with $50{\mu}L$ injection volume. This method was applied to the determination of $Br^-$, ${NO_3}^-$ and $I^-$ in sea water.

  • PDF

A Study on the Trace Analysis of Germanium in Inorganic Matrices by Differential Pulse Polarography (Differential Pulse Polarography에 의한 무기물 시료 중 Germanium의 미량 분석에 관한 연구)

  • Shin, Ho-Sang;Oh, Yun-Suk;Shin, Hak-Soo
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.253-261
    • /
    • 1996
  • Analytical method for the determination of trace germanium in inorganic matrices by differential pulse polarography(DPP) was studied. The reduction peak of germanium(IV) in perchloric acid solution containing 1, 2, 3-trihydroxy benzene appeared at -0.45V(vs. Ag/AgCl) and the peak current for germanium complex varied linearly with concentration variation. Factors affecting sensitivity and precision for germanium quantification were studied and detection limit under the investigated parameters was 1ng/ml. Inorganic samples were decomposed by fusion with potassium pyrosulfate. Serious interferences of Se(IV), Pb(II), As(III) for the determination of germanium were discussed. Interferences of these elements could be avoided by extraction of germanium from decomposed matrices by $CCl_4$ in 10M HCl solution. The germanium contents of inorganic samples(Pb bf. dust, Cu bf. dust, gneiss, Cu anode slime) were determined by the above method.

  • PDF

Ultrasonic Flaw Detection in Turbine Rotor Disc Keyway Using Neural Network (신경회로망을 이용한 터빈로타 디스크 키웨이의 결함 검출)

  • Son, Young-Ho;Lee, Jong-O;Yoon, Woon-Ha;Lee, Byung-Woo;Seo, Won-Chan;Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.45-52
    • /
    • 2003
  • A number of stress corrosion cracks in turbine rotor disk keyway in power plants have been found and the necessity has been raised to detect and evaluate the cracks prior to the catastrophic failure of turbine disk. By ultrasonic RF signal analysis and using a neural network based on bark-propagation algorithm, we tried to evaluate the location, size and orientation of cracks around keyway. Because RF signals received from each reflector have a number of peaks, they were processed to have a single peak for each reflector. Using the processed RF signals, scan data that contain the information on the position of transducer and the arrival time of reflected waves from each reflector were obtained. The time difference between each reflector and the position of transducer extracted from the scan data were then applied to the back-propagation neural network. As a result, the neural network was found useful to evaluate the location, size and orientation of cracks initiated from keyway.

Remote Fault Detection in Conveyor System Using Drone Based on Audio FFT Analysis (드론을 활용하고 음성 FFT분석에 기반을 둔 컨베이어 시스템의 원격 고장 검출)

  • Yeom, Dong-Joo;Lee, Bo-Hee
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.10
    • /
    • pp.101-107
    • /
    • 2019
  • This paper proposes a method for detecting faults in conveyor systems used for transportation of raw materials needed in the thermal power plant and cement industries. A small drone was designed in consideration of the difficulty in accessing the industrial site and the need to use it in wide industrial site. In order to apply the system to the embedded microprocessor, hardware and algorithms considering limited memory and execution time have been proposed. At this time, the failure determination method measures the peak frequency through the measurement, detects the continuity of the high frequency, and performs the failure diagnosis with the high frequency components of noise. The proposed system consists of experimental environment based on the data obtained from the actual thermal power plant, and it is confirmed that the proposed system is useful by conducting virtual environment experiments with the drone designed system. In the future, further research is needed to improve the drone's flight stability and to improve discrimination performance by using more intelligent methods of fault frequency.

Evaluate the usefulness of Coincidence Summing Correction Factors for Cylinder and Extended Source Penelope Simulation (실린더 및 확장 소스 PENELOPE 시뮬레이션에 대한 동시합성보정 계수 유용성 평가)

  • Jang, Eun-Sung;Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.821-831
    • /
    • 2021
  • In order to calibrate energy and efficiency using the PENELOPE Code, a PENELOPE simulation was performed using a volume source. Here, we want to verify peak efficiency and usefulness by performing simultaneous measurement and correction. calculate the coincident sum correction for all volumes, first subdivide the volumes of the cylinder and the four Marinelli beakers into three heights again. Therefore, the simultaneous measurement correction coefficient in three areas and the simultaneous measurement correction coefficient for the entire volume source are calculated as output. At low energies, the j value for each source volume (50-300 ml) is small and increases significantly in the high energy range. Simulation results showed good agreement within 2.5% for all source volumes except for 50 ml and 300 ml, which were up to 4%. This means that the correction for the simultaneous measurement effect during measurement is effective. In addition. Based on this, it can be confirmed that there is an advantage to improve the detection efficiency when measuring various sources and environmental samples.

10 GHz LC Voltage-controlled Oscillator with Amplitude Control Circuit for Output Signal (출력 신호의 진폭 제어 회로를 가진 10 GHz LC 전압 제어 발진기)

  • Song, Changmin;Jang, Young-Chan
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.975-981
    • /
    • 2020
  • A 10 GHz LC voltage-controlled oscillator (VCO), which controls an amplitude of output signal, is proposed to improve the phase noise. The proposed amplitude control circuit for the LC VCO consists of a peak detector, an amplifier, and a current source. The peak detector is performed detecting the lowest voltage of the output signal by using two diode-connected NMOSFET and a capacitor. The proposed 10 GHz LC VCO with an amplitude control circuit for output signal is designed using a 55 nm CMOS process with a supply voltage of 1.2 V. Its area is 0.0785 ㎟. The amplitude control circuit used in the proposed LC VCO reduces the amplitude variation 242 mV generated in the output signal of the conventional LC VCO to 47 mV. Furthermore, it improves the peak-to-peak time jitter from 8.71 ps to 931 fs.

Classification and identification of organic aerosols in the atmosphere over Seoul using two dimensional gas chromatography-time of flight mass spectrometry (GC×GC/TOF-MS) data (GC×GC/TOF-MS를 이용한 서울 대기 중 유기 에어로졸의 분류 및 동정)

  • Jeon, So Hyeon;Lim, Hyung Bae;Choi, Na Rae;Lee, Ji Yi;Ahn, Yun Kyong;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.153-169
    • /
    • 2018
  • To identify a variety of organic compounds in the ambient aerosols, the two-dimensional gas chromatography-time of flight mass spectrometry (GCxGC) system (2DGC) has been applied. While 2DGC provides more peaks, the amount of the generated data becomes huge. A two-step approach has been proposed to efficiently interpret the organic aerosol analysis data. The two-dimensional 2DGC data were divided into 6 chemical groups depending on their volatility and polarity. Using these classification standards, all the peaks were subject to both qualitative and quantitative analyses and then classified into 8 classes. The aerosol samples collected in Seoul in summer 2013 and winter 2014 were used as the test case. It was found that some chemical classes such as furanone showed seasonal variation in the high polarity-volatile organic compounds (HP-VOC) group. Also, for some chemical classes, qualitative and quantitative analyses showed different trends. Limitations of the proposed method are discussed.

Correlation of the Wall Skin-Friction and Streamwise Velocity Fluctuations in a Turbulent Boundary Layer(II) (난류경계층에서 벽마찰력과 유동방향 속도성분과의 상관관계(II))

  • Yang, Jun-Mo;Yu, Jeong-Yeol;Choe, Hae-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.3
    • /
    • pp.427-435
    • /
    • 1997
  • Conditional sampling techniques are utilized to investigate the relation between the wall skin-friction and stream wise velocity fluctuations in a turbulent boundary layer. Conditionally averaged results using a peak detection and the VITA (variable-interval time-averaging) technique show that a high skin friction is associated with high frequency components of the wall skin-friction fluctuations. The conditionally averaged wall skin-friction fluctuations obtained by using the VITA technique have a positively-skewed characteristics compared with the conditionally averaged stream wise velocity fluctuations. It is confirmed that there exists a phase shift between the wall skin-friction and stream wise velocity fluctuations, which was also found from the long-time averaged space-time correlations. The amount of phase shift between the wall skin-friction and stream wise velocity fluctuations is the same as that from the long-time averaged space-time correlations and does not change despite the variation of the detection threshold.

Design and Implementation of a 9V Mini-Electrocardiograph(ECG) system (9V 초소형 심전도계의 설계 및 구현)

  • Song, Myeong-Kil;Park, Kwang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1130-1133
    • /
    • 2008
  • In this paper, a mini-Electrocardiograph(ECG) system operated by a general 9V alkaline battery is designed and implemented. The manufactured ECG consists of the instrumentation amplifier stage for detecting and amplifying the heart signal, the high pass filter(HPF), the low pass filter(LPF), the differentiator cirduit, and the peak detector. The detected heart signal through three leads is displayed cleanly on the oscilloscope, which shows the good operation of our ECG. As the detected heart signal is digitalized and displayed on the small LCD unit, the convenience of easy checkup and portability of the implemented ECG can be largely improved. Therefore, whenever and wherever anyone may checkup his/her cardiac state with ease.