• Title/Summary/Keyword: 피치

Search Result 1,320, Processing Time 0.025 seconds

Influence of crestal module design on marginal bone stress around dental implant (임플란트 경부 디자인이 변연골 응력에 미치는 영향)

  • Lim, Jung-Yoel;Cho, Jin-Hyun;Jo, Kwang-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.224-231
    • /
    • 2010
  • Purpose: This study was to investigate how the crestal module design could affect the level of marginal bone stress around dental implant. Materials and methods: A submerged implant of 4.1 mm in diameter and 10 mm in length was selected as baseline model (Dentis Co., Daegu,Korea).A total of 5 experimental implants of different crestal modules were designed (Type I model : with microthread at the cervical 3 mm, Type II model : the same thread pattern as Type I but with a trans-gingival module, Type III model: the same thread pattern as the control model but with a trans-gingival module, Type IV model: one piece system with concave transgingival part, Type V model: equipped with beveled platform). Stress analysis was conducted with the use of axisy mmetric finite element modeling scheme. A force of 100 N was applied at 30 degrees from the implant axis. Results: Stress analysis has shown no stress concentration around the marginal bone for the control model. As compared to the control model, the stress levels of 0.2 mm areas away from the recorded implant were slightly lower in Type I and Type IV models, but higher in Type II, Type III and Type V models. As compared to 15.09 MPa around for the control model, the stress levels were 14.78 MPa, 18.39 MPa, 21.11 MPa, 14.63 MPa, 17.88 MPa in the cases of Type I, II, III, IV and V models. Conclusion: From these results, the conclusion was drawn that the microthread and the concavity with either crestal or trans-gingival modules maybe used in standard size dental implants to reduce marginal bone stress.

Three-dimensional finite element analysis of stress distribution for different implant thread slope and implant angulation (임플란트 나사선 경사각과 식립 각도에 따른 3차원 유한요소 응력분석)

  • Seo, Young-Hun;Lim, Hyun-Pil;Yun, Kwi-Dug;Yoon, Suk-Ja;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: The purpose of this study was to find an inclination slope of the screw thread that is favorable in distributing the stresses to alveolar bone by using three dimensional finite element analysis. Materials and methods: Three types modelling changed implant thread with fixed pitch of 0.8 mm is the single thread implant with $3.8^{\circ}$ inclination, double thread implant with $7.7^{\circ}$ inclination and the triple thread implant with $11.5^{\circ}$ inclination. And three types implant angulation is the $0^{\circ}$, $10^{\circ}$ and $15^{\circ}$ on alveolar bone. The 9 modelling fabricated for three dimensional finite element analysis that restored prosthesis crown. The crown center applied on 200 N vertical load and $15^{\circ}$ tilting load. Results: 1. The more tilting of implant angulation, the more Von-Mises stress and Max principal stress is increasing. 2. Von-Mises stress and Max principal stress is increasing when applied $15^{\circ}$ tilting load than vertical load on the bone. 3. When the number of thread increased, the amount of Von-Mises stress, Max principal stress was reduced since the generated stress was effectively distributed. 4. Since the maximum principal stress affects on the alveolar bone can influence deeply on the longevity of the implants. When comparing the magnitude of the maximum principal stress, the triple thread implant had a least amount of stress. This shows that the triple thread implant gave a best result. Conclusion: A triple thread implant to increase in the thread slope inclination and number of thread is more effective on the distribution of stress than the single and double thread implants especially, implant angulation is more tilting than $10^{\circ}$ on alveolar bone. Thus, effective combination of thread number and thread slope inclination can help prolonging the longevity of implant.

Fundamental Studies on the Development of Axial-Flow Combine(I) -Evaluation of the Design Parameters of Grain-Straw Separator- (축류(軸流) 콤바인의 개발(開發)에 관(關)한 기초(基礎) 연구(硏究)(I) -조선별장치(粗選別裝置)의 설계변수(設計變數)의 평가(評價)-)

  • Lee, S.K.;Kim, S.T.;Choi, K.H.
    • Journal of Biosystems Engineering
    • /
    • v.11 no.2
    • /
    • pp.31-40
    • /
    • 1986
  • Cylindrical and conical types of grain-straw separation equipment which has a stationary crimped sieve drum with rotating inner rotor were constructed. The developed equipments were tested to investigate the characteristics of separating performance under various mechanical conditions and crop conditions. As increase of the inclination of equipment and decrease of pitch of cover vane, the grain recovery was increased while straw rejection was decreased. The grain recovery and overall efficiency were decreased as the rotor speed and feeding velocity were increased for both varieties of rice, moisture contents, and test equipments. Conical prototype equipment performed higher straw rejection, lower grain recovery, and lower power requirement. However, separation performance of conical type equipment was more widely varied with various test conditions compared to cylindrical one. The performance of both equipments showed relatively insensitive to crop feedrate and crop properties, such as variety, moisture content, and grain-to-straw ratio.

  • PDF

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.

Dam-Heon Hong Dae Yong's : A part of the BukHak School's Understanding on The Great Learning (담헌 홍대용의 <대학문의(大學問疑)> : 북학파의 『대학』 이해의 일단(一端))

  • Ahn, Woe Soon
    • (The)Study of the Eastern Classic
    • /
    • no.33
    • /
    • pp.385-411
    • /
    • 2008
  • This thesis aims at examining his understandings about the The Great Learning centering on the of the founder of the YiYongHuSaeng School (利用厚生學派: A school who pursued prosperous economy and welfare of people) orthe BukHak School(北學派: A positive school that pursued mercantilism) from the Joseon Dynasty, Dam-Heon Hong Dae Yong (1731-1783). 1) From what is indicated in the , his studies mainly focused on the annotations from DaeHakJangGuDaeJeonJipJu ("大學章句大全集註": A book that edited different phrases from the Great Learning into chapters and paragraphs), Questioning of the Great Learning", and "JuJaUhRyu (朱子語類: A book of Confucian literature written by Yeo Jung Deok" of Zhu Xi who was a representative scholar of the Neo-Confucianism in the Song Dynasty. 2) Acknowledging entirely the arguing points of Zhu Xi, he is taking a critical position in a way that partial doubts are divided into seven chapters and questioned. 3) For the main characteristic and direction of the questioning, he is estimating that Zhu Xi only stressed the 'means' and 'interior' out of the world of 'means and ends' and 'interior and exterior' in Zhu Xi's recognizing and handling cases; instead, he emphasized putting equivalent value on the 'ends' and 'exterior' as well. 4) In fact, such questions raised partially were misconceived since they were not carried out through profound understanding nor systematic logic expansion of what Zhu Xi insisted. 5) Despite this, at the point where Neo-Confucian thoughts were fixed and weakened only with its form left in the late Joseon Dynasty, his perspective on the study of Confucian classics that the 'ends' and 'exterior' should be as equally valued as the 'means' and 'interior' by examining through the core text of the Neo-Confucianism, The Great Learning has its significance in his YiYongHuSaeng dogma that says politicians, by all means, should provide the ruled with economic convenience and welfare and this is their very right virtue.

Evaluation of the usefulness of Halcyon VMAT treatment plan through comparison with tomotherapy in bilateral breast cancer radiation therapy. (양측 유방암 방사선치료 시 토모테라피와의 비교를 통한 Halcyon VMAT 치료계획의 유용성 평가)

  • LIM JUN TAEK;PARK JU YOUNG;PARK SU YEON;JEON SEONG JIN;PARK TAE YANG;HWANG DA JIN
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.83-92
    • /
    • 2022
  • Purpose: To evaluate usefulness of Tomotherapy and Halcyon VMAT treatment in radiation therapy for bi-breast cancer Materials and Methods: For 10 patients with bi-breast cancer, volumetric modulated arc therapy(VMAT) treatment plan was established using helical Tomotherapy(Accuray. USA) with field width of 5.0-cm and pitch of 0.287, and Halcyon(Varian Medical System, Palo Alto, CA, Version 3.0 USA) of 6arc and 8arc. Prescribed dose was 42.4 Gy/16, and V 40.3Gy of Planning Target Volume(PTV) was 90%. The quality of plan was evaluated by comparing the dose to tumor and normal organs, and the efficiency was evaluated by comparing total MU and beam on time. Results: About three treatment plans(Tomotherapy, Halcyon 6Arc VMAT, Halcyon 8Arc VMAT) , the mean homogeneity index(H.I) of PTV were 1.07, 1.10, 1.11, and the mean conformity index(C.I) of PTV were 1.21, 1.16, 1.17, respectively. The average value of the dose assessment item for a normal organ is V 5Gy(%) of both lung was 36.3, 31.2, 29.7, and V 15Gy(%) were 18.6, 15.5, 14.6, respectively. The mean heart dose(Gy) were 4.17, 2.69, 2.51. Total MU were (7498.6, 2494.2, 2471.5), and beam on time(sec) were 462.5, 195.4, 198.0. Conclusion: Halcyon VMAT showed similar quality of treatment plan compared to helical Tomotherapy, while also protecting normal organs. In addition, the efficiency of radiotherapy increased due to a decrease in Beam On Time and MU.

A Style Study for Reissued Gongsin-Gyoseo in Joseon Dynasty (조선시대 재발급(再發給) 공신교서(功臣敎書) 양식 연구)

  • Sim, Young-hwan;Lee, Jin-hee
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.2
    • /
    • pp.4-19
    • /
    • 2014
  • In Joseon dynasty, Gongsin-Gyoseo(Royal Edicts rewarding meritorious vassals) was issued for the reward of the contribution to the specific event of the nation. The family decided as vassals succeeded this Gongsin-Gyoseo as the family treasure to later generations. When one happened to lose this caused by an unavoidable situation such as war in this process, there were a few cases of reissuing of Gongsin-gyoseo by the nation. The confirmative reissued Gongsin-gyoseo among Gongsin-gyoseo that descended down by now are three pieces which is Park dongnyang Hoseong Gongsin-Gyoseo, Gu goeng Jeongsa Gongsin-Gyoseo, and Park jung Jeongsa Gongsin-Gyoseo. This research considered the form and mounting about these three pieces. It was indicated that the reissued Gongsin-Gyoseo was produced following the same form with the original Gongsin-Gyoseo, that is pyeongchul(moving to next lines) and daedu (writing one or two letters ahead compared to the first letter) and so on. But, it was indicated that the change of the position of the vassals in the reissued time was reflected compared to position of the original Gongsin-Gyoseo. In case of Jeonsa Gongsin-Gyoseo, it was indicated that it was 'Wonjongdaewang-whi' since the original Gongsin-Gyoseo was 'Jeongwongun-bu' and the reissued time he became the father of King Injo. Also, it was confirmed that the case of deprivation because of conspiracy such as 'Kim jajeom, Kim ryeon, Sim kiwon, Sim kisung' was produced as the original document and deleted with black ink stick. It was newly confirmed while the original Gongsin-Gyoseo was produced by a designated writer from the nation, the reissuance was written by a writer from the family of the vassals. Since the mounting of Gongsin-Gyoseo could be changed according to the favor and technique of the craftsman participated in the practical production such as Baezeopjang and economical situation of the country supplying the material, the mounting of these three Gongsin-Gyoseo should be different from the original mounting, especially because of the loss of the original by the Manchu war of 1636. The comparison result of Gongsin-Gyoseo produced in the same period with the original issued one in the record of the related Uigwe (a collection of documents from the Joseon Dynasty), the reissued one seems to be larger in the form or ratio of the mounting compared to the first issued one. First of all, the width of Byunah was expanded as twice bigger, center and both side Hoejang also was bigger as over 2cm, and the below Hoejang was expanded as 10cm, and the ratio of the upper Hoejang and the below Hoejang was wider as 1.5 times and the reissuance was 1:1 ratio. The bisect of upper shaft in Park dongnyang Hoseong Gongsin-Gyoseo is assumed as the form of an equilateral triangle, not a half-moon shape of the present, and Gu goeng and Park jung Jeongsa Gongsin-Gyoseo will be the form whose bisection form is same but the size is smaller. Chuksu is confirmed that the size is not changed significantly. Osaekdahoe can be assumed that the width was smaller compared to the first issued one. The 3 pieces of the reissued versions provide the clue of the verification for the form of the mounting of Bosa Gongsin-Gyoseo in the same production period. In the situation that the mounting of the production time was not confirmed among the currently descended Bosa Gongsin-Gyoseo, they can be very important materials.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

The Analysis of Radiation Exposure of Hospital Radiation Workers (병원 방사선 작업 종사자의 방사선 피폭 분석 현황)

  • Jeong Tae Sik;Shin Byung Chul;Moon Chang Woo;Cho Yeong Duk;Lee Yong Hwan;Yum Ha Yong
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.157-166
    • /
    • 2000
  • Purpose : This investigation was peformed in order to improve the health care of radiation workers, to predict a risk, to minimize the radiation exposure hazard to them and for them to realize radiation exposure danger when they work in radiation area in hospital. Methods and Materials : The documentations checked regularly for personal radiation exposure in four university hospitals in Pusan city in Korea between January 1, 1993 and December 31, 1997 were analyzed. There were 458 persons in this documented but 111 persons who worked less then one year were excluded and only 347 persons were included in this study. Results : The average of yearly radiation exposure of 347 persons was 1.52$\pm$1.35 mSv. Though it was less than 50mSv, the limitaion of radiation in law but 125 (36%) people received higher radiation exposure than non-radiation workers. Radiation workers under 30 year old have received radiation exposure of mean 1.87$\pm$1.01 mSv/year, mean 1.22$\pm$0.69 mSv between 31 and 40 year old and mean 0.97$\pm$0.43 mSv/year over 41year old (p<0.001). Men received mean 1.67$\pm$1.54 mSv/year were higher than women who received mean 1.13$\pm$0.61 mSv/year (p<0.01). Radiation exposure in the department of nuclear modicine department in spite of low energy sources is higher than other departments that use radiations in hospital (p<0.05). And the workers who received mean 3.59$\pm$1.81 msv/year in parts of management of radiation sources and injection of sources to patient receive high radiation exposure in nuclear medicine department (p<0.01). In department of diagnostic radiology high radiation exposure is in barium enema rooms where workers received mean 3.74$\pm$1.74 mSv/year and other parts where they all use fluoroscopy such as angiography room of mean 1.17$\pm$0.35 mSv/year and upper gastrointestinal room of mean 1.74$\pm$1.34 mSv/year represented higher radiation exposure than average radiation exposure in diagnostic radiology (p<0.01). Doctors and radiation technologists received higher radiation exposure of each mean 1.75$\pm$1.17 mSv/year and mean 1.50$\pm$1.39 mSv/year than other people who work in radiation area in hospital (p<0.05). Especially young doctors and technologists have the high opportunity to receive higher radiation exposure. Conclusions : The training and education of radiation workers for radiation exposure risks are important and it is necessary to rotate worker in short period in high risk area. The hospital management has to concern health of radiation workers more and to put an effort to reduce radiation exposure as low as possible in radiation areas in hospital.

  • PDF