• Title/Summary/Keyword: 피조미터

Search Result 6, Processing Time 0.02 seconds

Measurements of Streambed Hydraulic Conductivity Using Drive-point Piezometers and Seepage Meters in the Upper Reaches of Anseong Stream (관입형 피조미터와 시피지미터를 이용한 안성천 상류구간 하상 수리전도도 측정)

  • Lee, Jeongwoo;Chun, Seon Geum;Yi, Myeong Jae;Kim, Nam Won;Chung, Il-Moon;Lee, Min Ho
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.413-420
    • /
    • 2015
  • Streambed hydraulic conductivity along the upper reaches of the Gongdo stage of Anseong Stream was estimated through measurements of stream-aquifer exchange rates (using a seepage meter) and vertical hydraulic gradients (using a manually driven piezometer). From the measured data, it was found out that the stream-aquifer exchange rates varied from -1.55 × 10-6 to 1.77 × 10-5 m/s, the corresponding vertical hydraulic gradient varied from -0.122 to 0.030, and the values of the streambed vertical hydraulic conductivity were estimated from 1.77 × 10-5 to 1.97 × 10-3 m/s, with variations representing local differences. The results are within the general range of streambed hydraulic conductivity values suggested by Calver (2001) and are slightly higher than values previously measured at other stream sites in Korea. The combined use of a drive-point piezometer and seepage meter (both constructed of high-strength stainless steel) is expected to be of practical use in the estimation of streambed hydraulic conductance, given the durability and portability of the instruments.

Analysis of stream depletion from groundwater pumping near Hwangguji stream (황구지천 주변 지역 지하수 양수 영향 분석)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il-Moon;Hong, Sung Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.385-385
    • /
    • 2017
  • 지하수 관정의 위치에 따라 대수층과 인근 하천의 수리특성이 다양하여 하천수량에 미치는 지하수 양수의 영향이 공간적으로 다르게 발생하며, 그 영향을 지도(map)상에 표출한 것을 가칭 지하수 양수 영향구역도(국토교통부, 2014)라 한다. 본 연구에서는 황구지천 하류유역에 대해 하천주변 천부대수층 지하수 양수에 따른 하천수 감소량을 Hunt(1999, 2009)의 해석해로 산정하고 그 결과를 바탕으로 지하수 양수 영향구역도를 작성하였다. 지하수 양수 영향구역도 작성에 필요한 입력자료를 구축하기 위해서 현장에서 직접 양수시험을 수행하여 대수층 수리상수를 산정하고 기존 문헌값을 함께 이용하여 수리상수의 공간분포도를 작성하였다. 또한 양수시험공에 인접한 하천의 바닥에 피조미터 및 시피지미터를 설치하여 하상수리전도도를 측정하였다. 하천주변 및 하상의 수리상수값을 Hunt 해석해에 대입하여 지하수 양수량 대비 하천수 감소율을 30m 크기의 셀 단위로 산정하고 이를 구글어스상에 공간적으로 표출하였다. 하천구역에서 300m 이내 지역에서 지하수를 양수할 경우에는 양수기간 5년동안 평균적으로 양수량의 70%를 초과하는 하천수량의 감소가 일어나는 것으로 분석되었다. 지하수 양수 영향구역도를 활용하면 지하수 개발 이용자 및 허가 관련 행정기관이 지하수 관정의 공간적인 위치에 따른 하천수 감소 정도를 정량적으로 쉽게 파악할 수 있다.

  • PDF

Measurement of the Axial Displacement Error of a Segmented Mirror Using a Fizeau Interferometer (피조 간섭계를 이용한 단일 조각거울 광축방향 변위 오차 측정)

  • Ha-Lim, Jang;Jae-Hyuck, Choi;Jae-Bong, Song;Hagyong, Kihm
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.1
    • /
    • pp.22-30
    • /
    • 2023
  • The use of segmented mirrors is one of the ways to make the primary mirror of a spaceborne satellite larger, where several small mirrors are combined into a large monolithic mirror. To align multiple segmented mirrors as one large mirror, there must be no discontinuity in the x, y-axis (tilt) and axial alignment error (piston) between adjacent mirrors. When the tilt and piston are removed, we can collect the light in one direction and get an expected clear image. Therefore, we need a precise wavefront sensor that can measure the alignment error of the segmented mirrors in nm scale. The tilt error can be easily detected by the point spread image of the segmented mirrors, while the piston error is hard to detect because of the absence of apparent features, but makes a downgraded image. In this paper we used an optical testing interferometer such as a Fizeau interferometer, which has various advantages when aligning the segmented mirror on the ground, and focused on measuring the axial displacement error of a segmented mirror as the basic research of measuring the piston errors between adjacent mirrors. First, we calculated the relationship between the axial displacement error of the segmented mirror and the surface defocus error of the interferometer and verified the calculated formula through experiments. Using the experimental results, we analyzed the measurement uncertainty and obtained the limitation of the Fizeau interferometer in detecting axial displacement errors.

Measurement of Streambed Hydraulic Conductivity in Stream Sections in the Anseongcheon Watershed, Korea (안성천 수계 국가하천구간 하상 수리전도도 측정 시험)

  • Jeon, Seon-Keum;Lee, Il Hoon;Lee, Jeongwoo;Chung, Il-Moon;Hong, Sung Hun
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.377-382
    • /
    • 2017
  • Field experiments were conducted to estimate streambed hydraulic conductivity at 15 sites in the Anseongcheon watershed, Korea. Seepage meters and piezometers were installed in the streambed at each site to measure the amount of stream water-groundwater exchange and the hydraulic gradient. The vertical hydraulic conductivity was then calculated using Darcy's formula. The measured stream water-groundwater exchange rates were $4.08{\times}10^{-6}$ to $1.49{\times}10^{-5}m/s$, and the vertical hydraulic gradients were 0.005 to 0.145. The data suggest the streambed hydraulic conductivity to be $7.80{\times}10^{-5}$ to $1.58{\times}10^{-3}m/s$. The results show significant differences in connectivity between stream and aquifer. Quantification of the hydraulic interconnection between stream and aquifer, and evaluation of the effects of groundwater development and utilization on the streamflow require hydrogeological investigations of the connection between stream and aquifer, including the hydraulic conductivity of the streambed. Various field testing and analysis methods for hydrogeological assessment also require further improvement.

Setup of Infiltration Galleries and Preliminary Test for Estimating Its Effectiveness in Sangdae-ri Water Curtain Cultivation Area of Cheongju, Korea (청주 상대리 수막재배지의 지중 침투형 갤러리 설치와 예비 주입시험)

  • Moon, Sang-Ho;Kim, Yongcheol;Kim, Sung-Yun;Ki, Min-Gyu
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.445-458
    • /
    • 2016
  • Most of water curtain cultivation (WCC) area in Korea has been inveterately suffering from the gradual draw-down of groundwater level and related shortage of water resources at the late stage of WCC peak time. To solve this problem, artificial recharge techniques has been recently applied to some WCC area. This study introduces infiltration gallery, which is one of the artificial recharge methods, and tentatively examined the effectiveness of three galleries installed at Sangdae-ri WCC area of Cheongju City. Seven galleries are set up at each empty space between eight vinyl houses in this area and its dimension is designed as 50 cm in each width and height and 300 cm in each length. Installation process was including bed excavation, backfill with gravels and silica sands, and completion of gallery by equipment of piezometer and covering with non-woven cloth. For each B, C, D gallery, 3 types of test including preliminary, four step and one long-term injection were performed. The first preliminary test showed the rough relations between injection rates and water level rise as follows; 20 cm and 30 cm level rise for $33.29{\sim}33.84m^3/d$ and $45.60{\sim}46.99m^3/d$ in B gallery; 0 cm, 16 cm and 33 cm level rise for $21.1m^3/d$, $33.98m^3/d$ and $41.69m^3/d$ in C gallery; 29 cm and 42 cm level rise for $48.10m^3/d$ and $52.23m^3/d$ in D gallery. Afterwards, more quantitative results estimating effectiveness of artificial recharge were reasoned out through stepped and long-term injection tests, which is expected to be employed for estimating water quantity re-injected into the aquifer through these galleries by natural injection over the period of WCC peak time.

Use of a Temperature as a Tracer to Study Stream-groundwater Exchange in the Hyporheic Zone (열추적자를 이용한 지하수-하천수 혼합대 연구)

  • Kim, Kue-Young;Chon, Chul-Min;Kim, Tae-Hee;Oh, Jun-Ho;Jeoung, Jae-Hoon;Park, Seung-Ki
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.525-535
    • /
    • 2006
  • A study on stream-groundwater exchange was performed using head and temperature data of stream water, streambed, and groundwater. Groundwater level and temperature were obtained from multi-depth monitoring wells in small-scale watershed. During the summer and winter season, time series of temperature data at streambed and groundwater were monitored for six months. In the winter time, we measured the temperature gradient between stream water and streambed. The observed data showed three typical types of temperature characteristics. First, the temperature of streambed was lower than that of stream water; second, the temperature of streambed and stream water was similar; and the last, the temperature of streambed was higher than that of stream water. The interconnections between the stream and the streambed were not homogeneously distributed due to weakly developed sediments and heterogeneous bedrock exposed as bed of the stream. The temperature data may be used in formal solutions of the inverse problems to estimate groundwater flow and hydraulic conductivity.