• Title/Summary/Keyword: 피압대수층

Search Result 33, Processing Time 0.032 seconds

Parameter Identification of an unconfined Aquifer (피압 대수층의 전달경수 동정)

  • Lee, Jae-Hyeong;Park, Yeong-Gi;Hwang, Man-Ha
    • Water for future
    • /
    • v.17 no.4
    • /
    • pp.303-310
    • /
    • 1984
  • One of the delicate problems in aquifer problems in aquifer management is the identification of the spatial distribution of the hydrological parameters. To determine the distribution of the transmissivity in a aquifer, several data are available; the local values of transmissivity around well, interference tests, some knowledge of geological structure. All this information has to be combined to find a plausible representation of the aquifer. According to a three phased optimization process calculation is carried out; geostatistical estimate of the parameter field on the basis of known well point values adjustable on a limited numerical model, and modification of the values ot pilot points by a minimization algorithm. This procedure, applied to a known case, has proved to be very useful.

  • PDF

Hydrogeologic Parameter Estimation by Using Tidal Method in a Fractured Rock Aquifer (단열암반 대수층에서 조석분석법을 이용한 수리상수 추정)

  • Shim Byoung Ohan;Chung Sang Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.3
    • /
    • pp.27-32
    • /
    • 2004
  • The oceanic tides have an effect on groundwater levels in coastal fractured rock aquifers. The observed groundwater table fluctuations caused by the effective stress through an aquifer are shown as sine curves similar with tidal fluctuation. To estimate a hydrogeologic parameter, tidal method is utilized with groundwater level fluctuations of two monitoring wells. Cross correlation function is used to calculate time lags between observed groundwater levels and tide, and the deeper well shows longer time lag. The storage coefficients calculated by using tidal efficiency and time lag show large differences. The storage coefficients obtained by using time lags are close to the result of slug test, and that of the deeper well shows closer value by slug test. The tidal efficiency is unsatisfied to apply in the tidal method because of an effect of phreatic aquifer and the vertical flow of groundwater through fractured confining bed. This tidal method can be an economical and effective way to define the parameter by considering the location of observation well and hydrogeologic characteristics of a coastal aquifer.

A Study of Consolidation Behavior of Clay Ground with Partially Penetrated PVD under Artesian Pressure (연직배수재가 부분 관입된 점토지반의 피압에 따른 압밀 거동에 관한 연구)

  • Yun, Daeho;Nguyen, Ba Phu;Kim, Jaehong;Kim, Yuntae
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.1
    • /
    • pp.47-57
    • /
    • 2016
  • Many researchers reported that artesian pressure exists in thick soft ground of Busan Nakdong river estuary. Artesian pressure in soft ground could affect rate of consolidation, settlement and drainage capasity of prefabricated vertical drain(PVD). This paper investigated consolidation behaviors of soft ground with partially penetrated PVD subjected to artesian pressure. Laboratory tests with 1-dimensional large column equipment and their numerical analyses were carried out. Test results showed that the consolidation settlement of clay ground with artesian pressure was higher than that without artesian pressure. Due to artesian pressure, the dissipation rate of excess pore water pressure was reduced in soft ground with artesian pressure, especially at bottom part of clay ground. Numerical results were in good agreement with experimental test results.

Computing Hydraulic Parameters of Fractured Aquifers Using Fractal Model of Groundwater Flow with Leakage (누수를 포함하는 지하수 유동의 프락탈 모델 적용에 의한 균열 암반 대수층의 수리상수 산출)

  • 함세영;임정웅
    • The Journal of Engineering Geology
    • /
    • v.4 no.2
    • /
    • pp.219-229
    • /
    • 1994
  • Since groundwater flow in fractured rocks is controlled by the distribution of fractures irregu1arly developed in space, it is not possible to understand the hydraulic characteristics of fractured aquifers using Theis equation which is applicable only to homogeneous isotropic confined aquifer. This study deals with the theoretical background of the fractal groundwater flow model with leakage, the methodology of calculation of the hydraulic parameters, and the application of the developed model to field data. From the result of the application of the fractal model to two field data in Hongcheon and Yusung areas, we obtained a good match between theoretical curves and observed curves, with the same hydraulic parameters at the pumping well and the observation well. In the two pumping test analyses, we have determined 1.9 of the fractal dimension. This means that the dimension of groundwater flow at these two sites is slightly smaller than radial flow.

  • PDF

Self-weight Consolidation Settlement of Soft-grounds on the Artesian Pressure After the Penetration of Vertical Drain (연직배수재 타설 직후 피압대수층이 있는 지반의 자중압밀침하)

  • 김현태;조재홍;유전용;노종구;김승욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.597-604
    • /
    • 2002
  • This paper reviews depositional environments of marine deposits along the Nakdong river and then analytical solution of self-weight consolidation considering artesian pressure is made to find consolidated state. It's known that this area is in the under-consolidated state by the artesian pressure(u$\_$a/=0.3kg/$\textrm{cm}^2$) and the distribution of the artesian pressure is not linear but parabola. In predicting consolidation settlement for soft grounds improved by vertical drain, it is emphasized that the self-consolidation by sudden dissipation of artesian pressure should be considered.

  • PDF

A Study of Carvernous Limestone Aquifer of Jeon Cheon Basin (전천 석회암 대수층에 관한 연구)

  • 한종상
    • Water for future
    • /
    • v.16 no.3
    • /
    • pp.171-179
    • /
    • 1983
  • In the Jeon Cheon Basin, unconsolidated alluvium and marine clay beds overlying Tertiary conglomerate and impermeable mudstone, and Cambro-Ordovician sedimentary rocks composed of mainly cavernous limestones, and age-unknowned crystalline rocks are occured. Most productive rock is Cambro-Ordovician limestones containing a lot of solution openings and secondary porosities and shows its transmissivity of 1836$m^2$/day and storativity of 1.47 $\times$ $10^{-3}$. The storage of deep seated groundwater in linestone aquifer is estimated about 1059 $\times$ $10^6$ metric tons, being equivalent to 6 years total precipitation of the basin. The safe yield of the groundwater to be abstracted from the aquifer is about 126,000 tons/day. To pump at least 100,000 tons/day of groundwater from the said aquifer, a well field comprising 34 deep wells ranging in depth from 80 to 100 meter and penetrating the cavernous limestone aquifer shall be established at middle and down stream area.

  • PDF

Assessing the Utility of Rainfall Forecasts for Weekly Groundwater Level Forecast in Tampa Bay Region, Florida (주단위 지하수위 예측 모의를 위한 강우 예측 자료의 적용성 평가: 플로리다 템파 지역 사례를 중심으로)

  • Hwang, Syewoon;Asefa, Tirusew;Chang, Seungwoo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.1-9
    • /
    • 2013
  • 미래 기후 정보를 이용한 수문 환경의 단기 미래 예측은 안정적 수자원 공급을 위한 필수적 과제이다. 미국 플로리다 주 중서부 템파지역에서는 주요 수자원 중 하나인 지하수의 효과적 활용을 위해 지하수위 인공신경망 모델 (GWANN)을 개발하여 피압 대수층과 비피압 대수층에 대한 주 단위 평균 지하수위를 월별로 예측하고 그 결과를 수자원 공급 의사 결정에 반영하고 있다. 본 논문은 템파지역에 대한 GWANN 모델을 이용한 지하수위 예측 시스템을 소개하고 모델의 기후 입력 자료의 민감도를 분석함으로써 양질의 기후 정보에 대한 현 시스템의 활용성을 검토하였다. 2006년과 2007년에 대한 연구 결과, 관측 자료를 최적 예측 시나리오 (the best forecast)로 가정하여 적용한 결과는 지하수위 관측 지점에 따라 큰 차이를 보였지만 일반적으로 현 시스템 (현 시점의 실시간 주 단위 평균 강우량을 향후 4주간 동일하게 적용함) 에 비해 예측 성능이 개선되는 것으로 나타났다. 더불어 강우 관측 자료의 백분위 (percentile forecast; 20분위, 50분위, 80분위)를 강우 예측 자료로 활용한 경우에도 현 시스템과 비교하여 일부 나은 결과를 보여주었다. 그러나 지하수위 예측 모델을 활용하지 않고 현 시점의 지하 수위가 지속된다고 가정하는 경우 (na$\ddot{i}$ve model) 향후 2주간의 예측 결과가 best forecast 경우에 비해 높은 정확도를 보이는 등, GWANN 모델의 단기 예측에 대한 양질의 강우 예측 정보의 활용성은 낮으며, 향후 3주 이상에 대한 예측 성능에 있어 best forecast결과가 na$\ddot{i}$ve model 결과에 비해 높은 정확도를 보이기 시작하는 것으로 나타났다. 또한 GWANN 모델의 예측 성능은 적용 기간과 지역 및 지하대수층의 특성에 따라 큰 다양성을 가지는 단점을 보여 강우 예측 자료 활용에 앞서 모델 개선의 필요성이 있다고 판단된다. 본 연구는 단기수자원 공급 계획 수립을 위하여 사용되는 지역 모델링 시스템에 대한 기후 예측정보의 활용성 평가를 위한 방법론으로 고려될 수 있을 것으로 기대된다.

동남해안지역의 피압단열 대수층에서 조석 분석법을 이용한 수리상수 추정

  • 심병완;정상용;성익환;이병대;조병욱
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.497-500
    • /
    • 2003
  • If ground water levels of a confined fractured rock aquifer fluctuate with sea tides, individual values of hydrogeologic parameters can be determined. Tidal efficiency and time lag are first calculated from the water level data recorded at an observation device situated inland from the sea. The tidal efficiency factor of the aquifer at the seacoast is then determined from the observation in monitoring wells and used to calculate storage coefficient. Tidal efficiency factor and the tidal time lag are utilized to calculate storage coefficient and the results are compared. This method is tested in the southeastern coastal area of Busan, Korea. This is a simple and inexpensive way to test confined aquifer but the analysis should be performed according to the coastal environment.

  • PDF

Evaluation of Bacteriological Safety in Deep Confined Aquifer (심층피압지하수에서 세균군집의 분석에 의한 분변성 오염 평가)

  • 조장천;김상종
    • Korean Journal of Microbiology
    • /
    • v.35 no.1
    • /
    • pp.47-52
    • /
    • 1999
  • The study on the bacterial distribution was performed to evaluate the bacteriological safety in 4 deep confined aquifers drilled for drinking. All the investigated aquifers were oligotrophic, howevec bacterial densities and activities and the number of indicator bacteria in C-2 boreholes were much higher than those in other boreholes. Fecal pollution was observed in 3 boreholcs except C-1 borehole. The ratio of gram positive bacteria of the C-2 borehole was much lower than those 01 another boreholes. The numbers of total colifonns, fecal coliforms, and fecal Slreptococcus in the C-2 boreholes were 61, 33, 55 CFU (250 ml)$^{-1}$

  • PDF

The Numerical Study on Individual Vacuum Seepage Consolidation Method with Flexible Well Point (연성 Well Point를 적용한 개별진공 침투압밀공법에 관한 해석적 연구)

  • Kim, Byung-Il;Hong, Kang-Han;Kim, Young-Seon;Han, Sang-Jae
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2022
  • In this study, the individual vacuum seepage consolidation method, a new soft ground improvement method, was developed to supplement the conventional suction drain method (individual vacuum preloading method) and the geotechnical behavior was predicted through numerical analysis. If the individual vacuum seepage consolidation method applied, the effect of accelerating settlement and increasing the amount of settlement was high when the aquifer was located in the middle or at the bottom of the layer to the target improvement layer. It was found that the pumping amount in the aquifer does not affect the settlement behavior when it exceeds a certain level. Even vacuum pumping wells were installed in various locations, such as inside or outside of the embankment, the difference in settlement and horizontal displacement was insignificant. In addition, it was predicted that the settlement rate was the fastest and the horizontal displacement (inward) was large when both methods were carried out at the same time. Since this method can reach the target settlement amount very quickly, it was confirmed that it is possible to increase the spacing of vertical drain, thereby securing economic feasibility.