The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.

The Study on Scattered Radiation Effects According to Acquisition of X-ray Imaging using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 X선 의료영상 획득 시 산란선 발생 영향 연구)

  • Park, Ji-Koon;Kang, Sang-Sik;Yang, Seung-Woo;Heo, Ye-Ji;Kim, Kyo-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.549-555
    • /
    • 2018
  • The medical imaging technique images the contrast formed based on the difference in absorption coefficient of X-rays which changes according to the composition and thickness of the object. At this time, not only primary rays entering the image detector but also scattered rays greatly affect the image quality. Therefore, in this paper, Forward scattering rate and Scattered to primary ratio analysis were performed through Monte Carlo simulation in order to consider influence of scattered ray generated according to object thickness and radiation exposure area change on image quality. In the study, the Forward scattering rate corresponding to the thickness of the object was analyzed at a maximum of 15.3%p and the Scattered to primary ratio was analyzed at 2.00 to 4.54, but it was analyzed as maintaining a constant value for radiation exposure area change. Based on these results, the thickness of the object should be considered as a factor influencing the quality of the image, but radiation exposure area verified that it is a factor that does not affect the image quality. We believe that the results of this research can be utilized as basic information of scattered radiation to improve image quality.

Distribution of the Scatter Ray on Chest X-ray Examinations (흉부 X선 촬영 시 산란선 분포 연구)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.255-260
    • /
    • 2012
  • This study aims to examine the generation of scatter rays by dividing it into the presence of the subject at the chest X-ray examination, the X-ray tube and detector in the X-ray room, the front of the patient window, the outside of the entrance door of the patient waiting room, opening of the entrance door, the outside of the radiological technologist's entrance door, and the opening of the radiological technologist's entrance door, etc. When there is a subject, as the subject is thicker, more scatter rays occur at each of the spots for measurement. And when the entrance door is closed at the measurement, fewer scatter rays are generated.

A Study on the Detection Ability of Minute Lesions in X-ray Using the Molybdenum Target (Molybdenum 저지극을 이용한 X-ray의 미세병소 검출능력에 관한 연구)

  • Yang, Da-Rae;Dong, Kyung-Rae;Park, Yong-Soon;Ji, Youn-Sang;Kim, Young-Keun;Kim, Chang-Bok
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • Beam quality is determined according to Xray tube's target material. In a range of between 22 kVp and 28 kVp, molybdenum target generates the characteristics energy between the average 17.9 kVp and 19.5 kVp, which produces the high contrast image of the breast. In this study, we used the Mo/Mo combination breast device and ALVIM TRM phantom and measured the detection ability of the minute lesion in the breast imaging throughout analyzing ROC curves. Assuming that an average subject thickness of the breast is 40 mm, the detection ability was not dependent on the kVp changes in a while dependent on both the mAs and thickness change. We can assure that it is not needed to increase the kVp for the imaging of breast which thickness is within the mean range of 40 mm.

Design of Fuzzy Inference System for Cameras Inter-Axial Distance Control of Remote Stereoscopic Photographs (원거리 입체촬영용 카메라 축간거리 조절을 위한 퍼지추론 시스템)

  • Byun, Gi-Sig;Oh, Sei-Woong;Kim, Gwan-Hyung;Kim, Min;Kim, Hyun-Jo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.41-49
    • /
    • 2015
  • The common way to obtain a stereoscopic image of a subject at a distance is to place two cameras on the parallel axis rather than crossing axis. To find the IAD and maximum focal length, left and right images are obtained by varying the IAD of cameras and the focal length of the camera lens and the depth budget for the obtained images is analyzed through post production. Then, the database for IAD and focal length of the camera lens with the depth range that does not cause visual fatigue and visual discomfort are developed. These data are used to design fuzzy control and deduce the IAD and focal length of the camera lens to shoot a subject at a distance, and the function of the fuzzy control is confirmed through the actual shooting within the range of deduced IAD and focal length of the camera lens.

A motion detection technique utilization the variation characteristics of light intensity and motion (조명과 움직임의 변화특성을 이용한 동작검출 기법)

  • 김봉민;김진헌;김석기
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.940-943
    • /
    • 1998
  • 본 논문은 조명의 전체 혹은 국부적인 변화에 견실한 특성을 갖는 동작검출 기법에 관한 것이다. 피사체의 움직임과 조명이 변화의 특성을 파악하기 위해 본 논문에서는 두 영상의 상관계수와 영상의 차이를 종합적으로 이용하여 움직임 여부를 판단할 수 있는 지표를 산정하는 기법을 제시한다.

  • PDF

3D Depth Estimation by Using a Single Smart Phone Camera (단일 스마트폰 카메라를 이용한 3D 거리 추정 방법)

  • Bae, Chul Kyun;Ko, Young Min;Kim, Seung Gi;Kim, Dae Jin
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2018.06a
    • /
    • pp.240-243
    • /
    • 2018
  • 최근 VR(Virtual Reality)와 AR(Augmented Reality)의 발전에 따라 영상 또는 이미지에서 카메라와 물체 사이의 거리를 추정하는 기술에 대한 연구가 활발히 진행되고 있다. 본 논문에서는 카메라와 물체 사이의 거리 추정 방법 중에서 단일 카메라를 이용하여 촬영한 이미지의 흐림 정도를 분석하여 3D 거리를 추정하는 알고리즘을 연구한다. 특히 고가의 렌즈가 장착된 DSLR 카메라가 아닌 스마트폰 카메라 이미지에서 DFD를 이용한 거리 추정 방법 중 1개의 이미지를 이용한 3D 거리 추정 방법과 초점이 서로 다른 2개의 이미지를 결합하여 3D 거리를 추정하는 방법을 연구하고 최적회된 피사체 범위에 대해 연구하였다. 한 개의 이미지를 이용한 거리 추정에서는 카메라의 초점 거리를 200 mm로 설정할 때, 두 개의 이미지를 이용한 거리 추정에서는 두 이미지의 초점 거리를 각각 150 mm, 250 mm로 설정했을 때 가장 넓은 거리 추정 범위를 갖는다. 또한, 두 거리 추정 방법 모두 초점 거리가 가까울수록 가까운 물체의 거리 추정에 효율적인 것으로 나타났다.

  • PDF

Analysis of the minimum exposure position according to the additional filtration plate (부가여과판에 따른 최소한의 피폭 위치에 대한 분석)

  • Tae-Ri, Kim;Min-Ji, Kang;Sang-Hee, La;Yun-Jeong, Shin;Tae-Gyeom, Hong;Min-Cheol, Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.1 no.2
    • /
    • pp.11-17
    • /
    • 2022
  • The purpose is to find out where medical workers can receive the minimum radiation does in clinical. In order to sett RQR standard quality of radiation, put a Al 1.5mm filter(row and column: 10 cm × 10 cm) on X-ray tube. Al 0.9 mm, Cu 0.3 mm, Ni 0.3 mm used as a filter. The Acrylic phantom were set to 13.1 cm, 18.5 cm, 21.1 cm. by the object thickness was different. As a results, when we use Al 0.9 mm, 1853 nSv was the highest numeral. It is a point of anode low 50 cm, when we use 13.1 cm Acrylic phantom. When we use Cu 0.3 mm, 173 nSv was the lowest numeral. It is a point of anode low 150 cm, when we use 13.1 cm Acrylic Phantom. In this study, it was confirmed that the spatial scattering dose decreased as the distance from the X-ray tube increased. It is considered that more studies on the exposure of scattered doses are needed in the future.

A Study on the Video Halogen Spot Lighting replaced by LED Lighting Fixture (영상용 할로겐 스폿 조명기를 LED 조명 등기구 대치에 관한 연구)

  • Lee, Jang-Weon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.07a
    • /
    • pp.548-551
    • /
    • 2011
  • 본 연구에서는 방송 촬영용 LED Spot 조명기기를 두 가지 형태로 개발하여, 현재 방송용 스튜디오 조명기기가 설치되어 있는 공간에서 다수 사용되고 있는 영국의 Arri사 650W와 1000W Fresnel Spot 조명기기와 조도, 색온도, 연색성 등의 비교 데이터 측정과 피사체의 촬영 시 영상 및 연색성에 따른 색상을 비교 측정하였다. 그리고 방송 촬영용으로 LED Spot 조명기기가 대체 가능한지를 판단하기 위하여 성능평가분석 하였다.

  • PDF

진공조건에 따른 Parylene 코팅박막의 투명도 평가

  • Lee, Su-Min;Jo, Gyu-Seok;Lee, Ji-Yun;Lee, Yun-Jin;Heo, Seung-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.297-297
    • /
    • 2012
  • Parylene 코팅은 다결정인 고분자 유기물에 열을 가하여 기화시켜 진공상태에서 피사체를 코팅하는 것으로 마이크로 두께 단위의 유전체 증착하는 것이다. Parylene 코팅은 주로 Display를 비롯한 태양전지, 반도체 등에서 다양한 산업분야에서 이용되며, 이 때 외부로부터 침투하는 수분을 방지하고, 전기적 절연 및 불순물로부터 피사체를 보호하여 기계적인 안정성을 목적으로 사용된다. Display와 태양전지는 빛을 이용하는 분야로써 Parylene을 투과하여 들어오는 빛의 전달효율에 따른 영향이 크게 고려되어진다. 빛의 전달효율을 높이기 위해서는 Parylene의 높은 투명도가 중요한 요소로 작용한다. 본 연구에서는 Parylene 코팅 박막의 투명도 상승을 위해 증착 시 다양한 진공조건으로 실험을 진행하였다. Parylene 코팅 시, 진공도에 따른 투명도를 평가하기 위해 Substrate로는(100%)투과율을 가지는 재질의 glass를 이용하였다. Parylene 종류로는 반도체분야에 주로 이용되는 C-type의 Parylene Polymer 사용하였다. 증착 조건으로는 $7{\sim}8{\times}10^{-2}$ Torr, $4{\sim}6{\times}10^{-2}$ Torr, $2{\sim}3{\times}10^{-2}$ Torr의 각각 다른 진공 조건에서 120분간 증착시켜 Parylene 코팅막을 형성하였다. 또한 높은 투습방지력을 가짐과 동시에 고투명도 유지에 대해 신뢰성평가를 하기위해 각 조건별로 1회, 3회, 5회 반복 증착하였다. 제작된 각 시편의 투명도 측정을 위해 광도계(DX-100, TAKEMURA)를 이용하여 빛의 투과율을 관찰하였다. 그 결과 진공도 $2{\sim}3{\times}10^{-2}$ Torr, $4{\sim}6{\times}10^{-2}$ Torr, $7{\sim}8{\times}10^{-2}$ Torr순의 시편이 높은 투과율을 나타내었으며, 그 중 $2{\sim}3{\times}10^{-2}$ Torr의 1회 증착 한 시편이(97%)로 가장 높은 투과율을 나타내었다. 반대로 $7{\sim}8{\times}10^{-2}$ Torr의 5회 증착 한 시편이(78%)로 가장 낮은 투과율을 보였다. 따라서 진공도가 높을수록 투명도가 상승하며, 증착횟수가 늘어날수록 투명도가 감소하는 것을 알 수 있었다. 본 연구의 결과로 Parylene 코팅의 진공도에 따른 투명도를 평가함으로써 Parylene 코팅 증착조건 최적화를 위한 기초자료로 이용될 것이라 사료된다. 또한 후속 연구로써 substrate의 온도조절과 시료량의 조절이 이루어진다면 좀 더 효율적으로 최적화된 박막형성이 가능할 것이라 판단된다.

  • PDF