• Title/Summary/Keyword: 피부측정

Search Result 1,181, Processing Time 0.027 seconds

The Comparison of Shampoos for Skin Hydration by Measurement of Epidermal Capacitance in Normal Canine Skin (Epidermal Capacitance를 이용한 시판되는 치료용 샴푸의 정상적인 개 피부에 대한 가수효과)

  • Oh, Tae-Ho;Jae-Hoon heong;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.18 no.3
    • /
    • pp.206-210
    • /
    • 2001
  • Various commercial shampoos were frequently prescribed for dermatologic therapy in small animal practice. Skim hydration affected by the shampoos, however, was not evaluated routinely. In order to evaluate the skin hydration for the exact prescription of shampoos method to measure skin hydration of shampoos are needed. This study was undertaken to evaluate the skin hydration effect of shampoo on canine skin using Corneometer. Five healthy dogs were applied with 7 commercial shampoos: Humilac, Sebocalm, Sebolytics, Etiderm, Benzoyl peroxide, HyLyt and Zn-7 Derm. Skin hydrations were evaluated by measurement of electrical capacitance by Corneometer. A statistically significant increase in skim hydration was found 17(p<0.05) and 77 minutes(p<0.01) after application of Humilac indicating a humidifying effect of this product. A statistically significant decrease in skin hydration was found for the Benzoyl peroxide after 77 minutes(p<0.05). No statistically significant differences between the other shampoos were found. None of the products tested had any negative effect on the skin barrier function. The Corneometer was found useful for detecting skin hydration to shampoos and considered as a simple and useful tool for prescription of various shampoos routine practice.

  • PDF

Measurement of physiological response and estimation of subjective sensation with cool biz (쿨비즈 복장에 의한 생리적 반응 측정과 주관적 감각평가)

  • Gang, Nu-Ri;Lee, Ji-Yeon;Na, Yeong-Ju
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.236-238
    • /
    • 2009
  • 에너지 절약차원에서 냉방을 줄여 지구온난화 방지에 일조하고자 여름철에 가벼운 차림의 의복을 권장하는 쿨비즈 캠페인이 시작되었으나 이의 정량적인 효과를 분석하는 연구가 미흡하였다. 본 연구에서는 여름철 온실가스 줄이기 및 직장인 등의 건강증진 등을 위하여 기후복장 적응형에 대한 범국민 인식 및 실천 필요를 바탕으로, 실험을 통해 쿨비즈에 의한 생리적 반응 측정 및 주관적 감각평가를 실시하였다. 1 차실험은 두 복장(전통의복,기후의복)의 피부온 측정실험으로, 환경온 25, $27^{\circ}C$, 상대습도 50% RH 에서 20 대 성인남성 4 명을 대상으로 실험을 하였다. 피험자는 심신을 안정할 수 있도록 30 분간의 안정기를 가진 후에 60 분 동안 실험을 하였으며, 사무실 내 작업환경과 같은 분위기 조성을 위해 편안하게 의자에 앉아 가벼운 대화나 컴퓨터 워드작업 및 설문을 응할 수 있도록 피험자 앞 책상 위에는 노트북을 설치해 두었고, 실험 진행기간 동안 피부온, 직장온, 습도, 발한량, 열화상 카메라, 온열감, 습윤감, 쾌적감 등과 같은 주관적 감각을 측정하였다. 2 차 실험은 동일 피부온 발현하는 환경온 찾기로 기준온도($27^{\circ}C$)에서 전통복장을 입고 온도를 점진적으로 하강시키면서 $27^{\circ}C$ 기후 복장을 입은 상태의 피부온도와 동일해지는 실내온도를 측정한다. 착의 형태에 따른 피부온도 변화에서 환경온도 $25^{\circ}C$ 전통의복 기후의복에 의한 피부온도의 차이는 전통의복이 최소 0.3~최대 $1.6^{\circ}C$ 더 높게 나타났으며, 환경온도 $27^{\circ}C$에서 전통의복 기후의복에 의한 피부온도의 차이는 대체적으로 전통의복이 최소 0.4~최대 $1.0^{\circ}C$ 더 높게 나타났다. 주관적 감각평가에서도 기후의복보다 전통의복에서 온열감 습윤감 불쾌감이 더 높은 경향을 보였다. 주관적 감각으로는 $25^{\circ}C$ 전통의복과 $27^{\circ}C$ 기후의복에서 중립적인 느낌을 나타냈다.

  • PDF

Monte Carlo Simulation for the Measurement of Entrance Skin Dose on Newborn and Infants (영·유아의 입사피부선량 측정을 위한 몬테카를로 시뮬레이션)

  • Kim, Sang-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.346-352
    • /
    • 2012
  • Radiation dose estimation on the newborn and infants during radiation examinations, unlike for the adults, is not actively being progressed. Therefore, as an index to present exposure dose during radiation examinations on newborn and infants, entrance skin dose was measured, and the result was compared with results of monte carlo simulation to raise reproducibility of entrance skin dose measurement, and it was proved that various geometry implementation was possible. The resulting values through monte carlo simulation was estimated using normalization factors for entrance skin dose to calibrate radiation dose and then normalized to a unit X ray radiation field size. Average entrance skin dose per one time exposure was $78.41{\mu}Gy$ and the percentage error between measurement by dosimeter and by monte carlo simulation was found to be -4.77%. Entrance skin dose assessment by monte carlo simulation provides possible alternative method in difficult entrance skin dose estimation for the newborn and infants who visit hospital for actual diagnosis.

Study on the Skin Temperatures of the Orofacial Trigger Points for the Patients with TMJ disorders (턱관절장애환자의 안면 발통점의 피부온도에 대한 연구)

  • Jung, Deuk-Jin;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.4
    • /
    • pp.345-353
    • /
    • 2001
  • Thermography는 신체 체표면에서 발생되는 온도를 정량화하는 다양한 방법에 대한 일반적인 표현이다. Electrothermography는 의학분야에서 사용이 증가되고 있는 술식이다. 인체를 포함한 모든 물체는 적외선을 방출한다. 그래서, Wien의 법칙에 따르면, 방출되는 최대에너지에서의 주파수는 체온에 의존한다는 것을 알 수 있다. 따라서, 피부 표면에서 방출되는 적외선을 측정하는 것에 의해 온도가 측정될 수 있다. 최근에는, electrothermography가 만성 구강안면동통 환자의 진단에 있어서 새로운 진단 기기로서 각광을 받고 있다. 본 연구에서는 측두하악관절장애의 증상이 있는 교근, 측두근, 그리고 측두하악관절의 발통점의 피부 온도와 증상이 없는 대측의 피부 온도를 디지틀 적외선 체열 촬영으로 비교하고자 하였다. 측두하악관절장애를 주소로 하고 편측성의 구강안면동통을 호소하는 21명의 내원환자를 선택하였다. 디지틀적외선 체열촬영은 DTI-16-DOREX21(Dorex Inc., U.S.A) 기기를 사용하였다. 발통점 피부에 marker를 부착하고, 좌측과 우측의 color thermogram을 $0.1^{\circ}C$ 해상도로 측정하였다. 본 실험에서 측정한 발통점은 masseter inferior, masseter anterior, temporalis anterior 그리고 TMJ이었다. 증상이 있는 부위와 증상이 없는 대측의 피부온도 차이를 알아보기 위해 paired t-test를 사용하였으며, 실험 결과는 다음과 같다. 1. 급성 근육장애 환자에 있어서는 증상이 있는 부위와 증상이 없는 대측과의 피부온도 차이가 통계학적으로 유의한 차이가 있었다(p<0.0075). 2. 만성 근육장애 환자에 있어서는 증상이 있는 부위와 증상이 없는 대측과의 피부온도 차이가 통계학적으로 유의한 차이를 볼 수 없었다. 3. 측두하악관절 내장증 환자에 있어서는 증상이 있는 부위와 증상이 없는 대측과의 피부온도 차이가 통계학적으로 유의한 차이를 볼 수 없었다. 결론적으로 적외선 체열촬영은 급성저작근장애의 진단에 있어서 유용한 진단방법의 한가지로 사료되며, 앞으로 임상적으로 더욱더 심화된 연구가 필요할 것으로 사료된다.

  • PDF

Comfort and Body Temperature in Different Fabrics by Sensitivity Assessment (감각평가에 따른 원단의 쾌적감과 피부온도)

  • 전향란;신윤숙
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.145-147
    • /
    • 2000
  • 본 연구는 각기 다른 종류의 원단으로 운동복을 만들어 선수들에게 입혀서 운동을 20분간 실시하게 하여 원단에 따라 쾌적감을 평가하였다. 실험방법은 피부온도를 4부위 측정하였고 가슴부위에서 의복 내 온도를 측정하였으며 매 5분마다 주관적인 쾌적감을 신고하도록 하였다. 연구의 목적은 다른 종류의 원단으로 제작한 운동복에 따른 쾌적감과 피부온도의 변화와 의복내 온도의 변화를 알아봄으로서 원단별로 쾌적감을 느끼는 피부온도와 의복 내 온도를 찾아내고 운동복의 디자인이나 설계에 적용하여 쾌적한 운동복을 개발하고자 한다. 그 결과 동일한 원단에서 운동시의 쾌적감은 부위별 피부온도가 높을 때 보다 낮을 때에 쾌적감을 느끼고 있다는 것을 알 수 있었다. 즉 운동 시에 발생하는 열을 의복이 열 평형을 이루기 위해 빨리 열을 밖으로 배출할 수 있는 의복의 디자인이 필요하다는 것을 알 수 있었다. 각기 다른 원단에서는 시간별 감각평가를 비교한 결과 PE/Wool의 원단이 쾌적하다는 평가를 하였다. 처음 의복을 입었을 때와 운동 중 그리고 운동 후에 피부온도나 의복 내 온도 변화가 적을 때에 쾌적하다는 평가를 하였다.

  • PDF

Development of Intergrated Ring-Type System for Measurement Signal of Electrodermal Activity Based on Dynamic State (동적 상태의 신경변화 자극에 따른 피부전도도 신호 검출을 위한 반지형 통합 측정 시스템 개발)

  • Lim, Min-Gyu;Lee, Young-Jae;Lee, Jae-Ho;Park, Hee-Jung;Kang, Seung-Jin;Kim, Kyung-Nam;Lee, Jeong-Whan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.07a
    • /
    • pp.359-360
    • /
    • 2013
  • 본 연구에서는 외부 자극과 내적인 교감신경의 변화에 따라 나타나는 땀 반응으로 얻어진 생체신호를 다루었다. 즉, 땀 반응을 지칭하는 피부전도도를 측정할 수 있는 시스템과, 더불어 차량 운전시 혹은 운동 등의 동적 자극에 의한 영향을 최소화하여 교감신경에 의한 피부전도도의 신뢰도를 높일 수 있는 방안을 강구하였다. 기존의 두 개의 전극 간 리지스턴스(Resistance)를 측정하는 방식을 내부에서 분리된 한 개의 전극을 사용하여 신체적 움직임의 제한점을 해소하고 피부전도도로 나타난 생체신호가 외적인 움직임에 따른 영향인지 내적인 신경의 변화에 따른 영향인지를 추정할 수 있는 모듈을 개발하였다. 20명의 건강한 청년을 대상으로 피실험하여 기존의 생체신호 측정 장비인 MP-150의 EDA모듈과 동시 측정한 결과, 두 데이터가 약 88% 일치하는 것으로 확인하였다.

  • PDF

Verification of skin dose according to the location of tumor in Tomotherapy (토모테라피 시 종양의 위치에 따른 피부선량 검증)

  • Yoon, Bo Reum;Park, Su Yeon;Park, Byoung Suk;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • Purpose : To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. Materials and Methods : In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5mm and 10mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3mm and 5mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. Results : The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5mm and 3mm respectively. If placed 5mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5mm and 3mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2~17.1% whereas if the tumor is 5mm away from the ceiling part, the figure decreased to 2.8~9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment. Conclusion : This study found gaps between planned skin doses and actual doses in the Tomotherapy treatment planning. Especially to the Tomo-cocuh direction, skin doses were found to be larger than the planned doses. Thus, during the treatment of tumors near the Tomo-couch, doses will need to be more accurately calculated and more efforts to verify skin doses will be required as well.

두경부암의 6MV 광자선 치료 시 표면선량 증가를 위한 Spoiler의 유용성 평가

  • 이강혁;김원택;이화중;김대영
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.41-47
    • /
    • 2002
  • 1.목적 두경부암(head and neck Ca)과 쇄골상부(Supraclavicular)에 6MV 광자선으로 치료 시 치료부위(Target volume)가 피부에서 대략 $1^{\sim}2mm$정도 깊이에 위치할 경우, 6MV 광자선의 선량분포는 표면선량이 낮아서 치료에 적합하지 않기 때문에 Bolus와 같이 사용하지만 Skin Sparing(피부보호)효과의 손실로 피부의 손상이 발생할 수 있다. 이러한 이유로 피부의 보호와 치료 시 표면선량의 증가를 위해 Spoiler(산란판)를 제작하여 측정 후 그 특성을 이해하고 선량의 분포를 통하여 Bolus와 비교한 후에 Spoiler의 유용성에 대해 평가하고자 하였다. 2.방법 Siemens사 선형가속기(PRIMUS)의 6MV 광자선을 사용하여 Spoiler의 사용여부 및 Spoiler의 사용 시에는 조사면의 크기를 $5{\times}5,\;7{\times}7,\;10{\times}10,\;15{\times}15,\;20{\times}20cm^2$로 하고 Spoiler와 표면과의 거리는 6, 10, 15cm로 바꾸어 가면서 물팬톰(PTW. 독일)을 이용해 깊이와 측방에 따른 선량분포를 Markus 전리함(PTW. 독일)으로 측정하였으며 전리함의 방수를 위해 씌어진 방수 캡 때문에 표면선량을 별도의 고형 팬톰으로 측정하였다. 표면의 측정선량은 전리함의 측면 벽 등에 의한 선량 측정치의 증가 현상으로 과 반응을 보였으며 이를 교정하였다. 그리고 측정된 데이터를 치료계획 시스템(Pinnacle 6.0m)으로 비교, 분석하였다. 3.결과 Spoiler의 사용 시 3cm깊이 측정선량 백분율과 Spoiler를 사용하지 않은 해당 치료 조사면의 3cm깊이 선량의 백분율에 일치하도록 하여 가상의 치료 깊이인 2mm에서 측정값을 비교하여 본 결과 조사면 $5{\times}5,\;10{\times}10,\;20{\times}20cm^2$에서 OPEN시 62, 64, $70\%$, Bolus는 97, 97, $99\%$로 Spoiler의 사용 시 표면과의 거리가 6cm에서 82, 98, $103\%$, 10cm에는 72, 89, $101\%$, 15m에 65, 79, $96\%$로 나타났으며 표면에서의 측정값을 비교하여 본 결과 OPEN시 11, 17, $27\%$, Bolus는 84, 84, $86\%$, Spoiler의 사용 시 6cm에서 40, 71, $93\%$, 10cm에는 25, 50, $81\%$, 15cm에 18, 36, $67\%$를 나타내었다. 또한 3m깊이에서의 측방 선량분포에서 Spoiler의 거리변화(6, 10cm)는 심부선량의 변화에 영향을 주지 않는 것으로 확인할 수 있었다. 그리고 위의 실험측정치를 치료계획 시스템에 입력하여 선량분포를 확인한 결과 Spoiler를 사용하는 경우 OPEN에 비해 선량분포 영역을 표면으로 끌어 올릴 수 있으며 Bolus 보다 피부 보호효과는 어느 정도 유지가 되는 것을 보여주었다. 4.결론 이와 같이 Spoiler는 Bolus와 비교하여 6MV 광자선의 build up 영역을 표면으로 증가시키는 동시에 Skin Sparing(피부보호)효과를 유지할 수 있으며 두경부암의 치료에서 Spoiler의 사용이 가능한 조건으로는 조사면이 $5{\times}5cm^2$에서 Spoiler와 표면과의 거리가 6cm일 때, $7{\times}7cm^2$에서 6cm, 10cm였고 $10{\times}10cm^2$는 10cm, 15cm로, $15{\times}15cm^2$는 15cm의 간격으로 평가되었다. 또한 $20{\times}20cm^2$의 조사면, Spoiler가 6cm 간격 인 경우 Bolus를 사용한 것 보다 더욱 높은 표면선량을 나타내었다. 그러나 Spoiler와 표면간의 거리를 다르게 함으로써 깊이에 따라 선량분포를 다양하게 나타낼 수 있기 때문에 표면선량의 증가와 피부의 보호를 위해 환자의 피부 두께, 실제 치료 부위의 깊이 등을 고려한다면 Spoiler를 사용하는 것이 bolus를 사용하는 것보다 더 유용하게 적용할 수 있을 것으로 사료된다.

  • PDF

The Design of Embroidery Textile Electrodes for Biosignal Applications (생체신호 측정을 위한 자수 직물전극 디자인)

  • Gang, Da-Hye;Song, Ha-Yeong;Lee, Yeong-Jae;Lee, Jeong-Hwan;Lee, Ju-Hyeon;Jo, Ha-Gyeong;Jo, Hyeon-Seung
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.58-61
    • /
    • 2009
  • 최근 직물전극을 의복에 적용하여 의복을 착용한 상태에서 심전도, 심박과 같은 생체신호를 측정하는 방법이 다양하게 연구되고 있다. 그러나 대부분 직물전극의 경우, 높은 임피던스와 피부-전극 간의 불안정한 접촉으로 인해 생체신호를 측정하는 것은 매우어렵다는 문제점들이 지적되어 왔다. 이 논문에서는 피부-전극 간의 접촉을 향상시키기 위한 전극의 구조를 고안하여 의복에 적용함으로써, 착용자의 피부와 직물전극간의 접촉을 안정화 시킨 후, ECG(Electrocardiogram)를 측정하였다. 본 연구의 실험에 사용한 전극의 특성 분석 방법으로는 전극의 임피던스와 그에 따른 ECG 를 측정하여 SNR 분석을 실시하였다. 직물전극의 두 가지 구조와 직물전극과 트랜스미터 연결 스냅간 접촉 방식에 따른 ECG 측정을 비교한 결과, 전극 구조와 전도성 paste 사용 여부는 모두 ECG 측정에 영향을 미쳤다.

  • PDF

Development of a Skin Index Using Skin Characteristic Factors and Skin Biomarkers of Korean Women According to H igh Temperature and Low Humidity Environments (고온건조 환경에 따른 한국 여성의 피부 특성인자와 피부 바이오 마커를 활용한 피부 지수 개발)

  • Jihye Maeng;Gaewon Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.4
    • /
    • pp.341-348
    • /
    • 2023
  • In this study, basic skin characteristic data was measured by measuring skin hydration, skin sebum secretion rate, skin melanin index, skin redness index, skin redness image analysis, transepidermal water loss (TEWL), and amount of stratum corneum before and after creating a temporary high temperature and low humidity environments targeting Korean women in their 20s to 50s. Stratum corneum by tape stripping was collected at each measurement and skin biomarkers including total protein content, carbonylated protein, neutral lipid, and lipid peroxidation were analyzed. Based on the results, the differences before and after creating a high temperature and low humidity environments were confirmed, the correlation between skin characteristics and skin biomarkers was confirmed, and a new skin index was created based on this. The new skin index can be used in product efficacy evaluation, and the possibility of constructing a new clinical study method and using skin biomarker discovery research through additional research was confirmed.