• Title/Summary/Keyword: 피난 안전성

Search Result 250, Processing Time 0.039 seconds

A Comparative Study on Evacuation Behavior Characteristics of Trainees according to Experience Level on board a Training Ship (운항실습선 교육생의 승선 숙련도에 따른 피난행동특성 비교분석)

  • Hwang, Kwang-Il;Lee, Yun-Sok
    • Journal of Navigation and Port Research
    • /
    • v.38 no.3
    • /
    • pp.233-238
    • /
    • 2014
  • With the increasing needs on various leisure activities, the users of passenger ships and cruisers have been increased year by year. Although over 15 accidents per year betide on domestic passenger ships for last decade, the researches on the safety of crews and guests on boards are difficult to find. This study performed the comparative analysis by experiments on the evacuation characteristics between experience levels on board a training ship. The followings are the results. From the seniors' experiments, it is found that more various evacuation scenarios have to develope and drill as a part of education contents. And from the freshmen's trials, the importances of the evacuation education and the roles of existing crews on evacuation guides are pointed out as to increase the safety of new crews and/or guests who are not accustomed to onboard a ship. On the other, it is explained that the communications between evacuees are worthy and useful, and also save more evacuation times. And on the viewpoint of evacuation methodology, it is clear that captain and evacuation-related crews have to control all the evacuation passages and evacuees of each passages to save more lives.

A study of on the occupant movement speed during emergency evacuations for the evacuation safety assessment of domestic buildings (국내 건축물의 피난안정성평가를 위한 비상대피 시 재실자 이동속도에 관한 연구)

  • Youn, Ho-Ju;Hwang, Eunkyung
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.332-338
    • /
    • 2013
  • Recently in Korea, in order to ensure evacuation safety within buildings, reviewing and evacuation assessment using computer simulations has been performed from the planning and design stages. Since the results from the assessment mainly depends on the initial values of input elements, it is important to establish element specific data. Nevertheless evacuation related experiments and research are still insufficient to apply overseas standards to domestic conditions. This study intended to conduct a experiment on evacuation movement speed by age as part of element-specific data construction for domestic occupant movement speed. After analyzing domestic and overseas studies on evacuation movement speed, we conducted the experiment of evacuation movement speed for 134 people. Then, by carrying out a comparative analysis of the results of the movement speed obtained from the experiment with overseas movement speeds, we followed the validation procedures of the experimental results under domestic evacuation conditions. The data derived from the experiment is expected to serve as a basis for the movement speed of domestic evacuation safety assessment.

A Study on the investigation of outflow coefficient in exit and set-up plan for egress safety plan of PBD (성능적 피난안전계획을 위한 출구 유동계수의 조사 및 설정방안 고찰)

  • Seo, Dong-Goo;Kim, Dong-Eun;Hong, Hae-Ri;Hwang, Eun-Kyung;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.255-260
    • /
    • 2010
  • 최근 건축물은 초고층화 대형화 지하심층화 되어가고 있다. 한편, 이러한 건축물은 화재시 기존의 건축물 보다 피난안전성의 문제가 대두된다. 이에 따라 국내외에서는 성능적 피난안전계획을 목적으로 PBD를 시행하고 있다. 하지만 국내의 경우 국외에 비하여 그 방법론이 부족하고, 건축물의 피난용량이 부족한 시점에 놓여있다. 이러한 배경을 통하여 본 연구는 재실자 피난행동분석 중 피난계산에 중요한 요인인 출구유동계수를 조사하고, 기존의 국내외 문헌과 비교를 실시하였다. 이에 따라 종합표준치 1.88인/ms를 도출하였으며, 또한 실태조사의 한계성을 파악하고, 이를 통한 조사기법에 대한 프로세스를 제안하였다.

  • PDF

Study Improvement of the Evacuation Performance in a Double-Skin Structure (이중외피 구조 건축물의 피난성능 개선에 관한 연구)

  • Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.98-107
    • /
    • 2017
  • This study examined an effective way of measuring the evacuation performance in buildings, which are applied to a double skin facade through an evaluation of the escape safety. Buildings with a double skin facade appeared to have a faster combustion expansion speed for the upper floor if a fire occurs. Moreover, a double skin facade is more difficult to escape safely than a general building construction because of the limited design standards. Accordingly, this study suggested virtual modeling including single emergency stairs and alarm systems considering the risk in each structure of buildings. These results showed that box-type double skin, corridor access type, shaft-box type, and multistory facade systems showed a 26.4%, 29.1%, 23.4%, and 26.3% increase in evacuation performance, respectively, as well as securing the safety of occupants.

A Study on the Recognitions on Evacuation and Architectural Design Characteristics of Child Care Center with Disabilities (장애아 전문 어린이집 피난인식 및 건축현황 분석 연구)

  • Lee, Jeong-Soo;Oh, Young-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.617-624
    • /
    • 2018
  • The purposes of this study are to propose architectural design and evacuation management guidelines for child care center with disabilities. To achieve these purposes, the questionnaire has carried out for director who manage child care center and analyzed the architectural characteristics of child care center for children with disabilities. The results of this study are as follows : (1) 65.3% directors think that less than 30% of children with disabilities in child care center can evacuate by oneself, and 73.2% of child care centers have difficulties for safe evacuation because of more than 50% of children with complex disabilities. (2) The moving or visual impaired children who live more than 2nd floors are need safe refuge areas for waiting in child care centers. (3) The child care centers for children with disabilities which were renovated from housing and multi-family housing have difficulties in vertical evacuating, and needs renovating for promotion of convenience and evacuation of children with disabilities.

A Study on Improvement of Evacuation Safety at Daycare Center (어린이집 피난안전 향상에 관한 연구)

  • Jin, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.63-73
    • /
    • 2017
  • As more and more the number of a couple working together for living has increased and an interest in early education has risen, daycare centers have made an effort to provide effective and good service beyond 'nursery care'. The most important thing in building in the event of disasters is safe evacuation of occupants. Having 'safe evacuation route' is required to reduce damage caused by disasters, It is necessary to give continuous and repeated training for right evacuation to infant and children so that they can evacuation successfully. This study examined problems that need improvement so that evacuation instrument installed in daycare centers can be used better by analyzing a survey of evacuation related facilities on daycare centers. This study found that laws and regulations on safety should be improved, evacuation facilities prepared against should be maintained regularly by relevant authorities, training for coping with disasters should be provied and evacuation instruments which are suitable for children.

Fire and Evacuation Simulation Analysis of Large-Scale Domestic Data Centers (국내 대규모 데이터센터 화재 및 피난 시뮬레이션 분석 )

  • Kim, Dong-Min;Go, Eun-Seong;Park, Hyeong-Gyoon;Gwak, Ji-Hyeon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.347-348
    • /
    • 2023
  • 본 논문에서는 실제 규모 데이터센터의 3D 모델링을 기반으로 대상 공간별 화재 시나리오를 선정하여 화재 및 피난 시뮬레이션을 수행하였다. FDS와 Pathfinder는 full coupling 방식을 사용할 수 없는 한계가 있으며 semi coupling의 경우 가시화에는 도움이 되나 결과에 영향을 주지 않는다. 따라서 재실자의 피난 상황 시 경로에 대한 안전성과 화재 위험 노출 정도를 시각적으로 분석하는 것이 가능한 semi coupling과 시뮬레이션 결과 데이터 분석을 병행하여 수행하였다. 전산실의 경우 서버의 기능상실 한계 온도가 32도이기 때문에 서버 기능 정지 상황에 도달하는 시간을 중점적으로 분석하였다. 전산실은 업무 및 고객 서비스와 관련된 모든 데이터들을 저장하기 위해 항시 기동 되어야 하는데 전산실 내 화재가 발생할 경우 1~2분 이내 서버 기능이 정지되는 상황이 발생하였다. 따라서, 서버가 안전하게 계속 동작하기 위해서는 전력 계측 및 제어 케이블 열화, 서버 장치의 건전성이 유지되어야 하며 초기 화재를 빠르게 감지하여 진압하여야 한다. 피난 시뮬레이션의 경우 가시도를 상실하게 되는 시간이 약 195초(5m 미만) 인근으로 인원이 해당 층을 완전히 벗어나는 데 걸리는 시간이 약 125.6초였던 것을 보면 대피하기에 충분한 허용 피난시간(ASET)을 확보하고 있음을 알 수 있었다.

  • PDF

Analysis of the Evacuation Safety with the Structure and Opening/Closing of Exits in a Fire at a Highway Service Area (고속도로 휴게소 화재 시 출입문의 구조와 개폐에 따른 피난안전성 분석)

  • Lee, Jai Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.419-425
    • /
    • 2021
  • This study analyzed the safety of evacuation according to the number of exits and the direction of evacuation routes with evacuation simulations of the Pathfinder in case of a fire at a highway service area. It was also analyzed of the difference in RSET by comparing the single or double types of the exit of a facility. The results were as follows. When only one direction exit was opened, all of the RSET were exceeded. When two or more different directions were opened according to the general principle of evacuation, all results met the RSET. The simulations showed that two or more different directions were more shortened in RSET than the one same direction. The result of the types of doors showed that the single type door was shortened in RSET rather than the double type doors. For the evacuation safety in a fire at the highway service areas, firstly, it is necessary to secure two or more exits in a fire at all times. Secondly, the exits should not be same directions. Finally, it is suggested that the exit should be installed with a single type of door.

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

A Study on ASET Elongation & Notification Time to Fire Stations for the Escape Safety of Aged Bedridden Patients in Elderly Long-term Medical Care (노인의료복지시설 화재 시 와상노인의 피난안전성 제고를 위한 피난허용시간 연장과 소방기관으로의 통보시간 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.50-59
    • /
    • 2018
  • Recently, huge life losses occurred in the elderly long-term medical care fires due to lack of escape safety. As part of the measures to enhance the effectiveness of fire escape safety, while they prolong the available safe egress time (ASET) of non fire compartments, a measure to shorten fire-fighter's arrival time by fire alarm notifying device should be implemented in these facilities. The four categories from the aspects of fire prevention/protection engineering were provided with the necessary component technologies for carrying out these helper-guided evacuations. Fire prevention engineered technology was presented by two provisions; one for ensuring small compartment sections by installing the fire rated wall between bed rooms and another for ensuring the fire retardant or/and non-flammable performance of finishing materials. Also fire protection engineered technology was presented by two items; one for imposing cooling effects by sprinklers and another for providing automatic fire alarm notifying functions to fire stations. In order to improve the escape safety of these facilities in Korea, alternative revisions may presented by considering insufficient provisions in the architectural/fire law provisions by analyzing the provisions of Japanese and domestic laws in detail.