• Title/Summary/Keyword: 피난특성

Search Result 221, Processing Time 0.024 seconds

A Study on the Character and Walking Velocity of Crowd Going up Stairs (계단에서 올라가는 군집보행의 속도에 관한 조사 및 특성에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.72-77
    • /
    • 2011
  • The effort of transferring some parts of urban functions to the underground space is growing trend among modem cities because of the limit of horizontal land use, the rise of land value, the diversification of human desire, etc. Thus, the basement of building and the subway station have deepened. It calls our attention to safety about evacuation from the underground space to the ground. Until now, the study about crowding walk in stairs has been progressed, focusing on the crowding walk that is going down the stairs, and there is no study about crowding walk that is going up the stairs. This study measured walking pace by crowd density that is going up the stairs in the subway station stairs making one-way movement of crowd. The actual survey showed that the mathematical relation 'V=0.638-0.0949p' determines going up walking velocity at a gradient of $23^{\circ}$, and the mathematical relation will be 'V=0.597-0.1067p' at a gradient of $30^{\circ}$, when it is converted, based on the average walking velocity of crowd by the slope of the stairs which is recommended by Architectural Institute of Japan.

A Study on the Suitability Impact Factors of a Comprehensive Park as an Emergency Shelter for Earthquakes (지진대피공간으로써의 공원녹지 적절성 평가지표 연구)

  • Cao, Lin-Sen;Kang, Tai-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.4
    • /
    • pp.62-70
    • /
    • 2017
  • Following the September $12^{th}$, 2016 earthquake in Gyeongju-city, the observation can be made that South Korea is not a non-earthquake country. Because of its particular characteristics, urban green spaces are good sites for protection during an earthquake but studies regarding the suitability of park green spaces as a form of earthquake shelter are few, making it difficult to highlight the function of park green spaces as emergency shelters. The purpose of this study is to identify indicators for suitability impact factors of comprehensive parks as emergency earthquake shelter zones. Using the Delphi method, three rounds of survey were implemented. According to the analysis results of Average value, CVR, Consultation and Convergence, ten candidate indicators were removed in the candidate group. Twenty-seven suitability impact factors of comprehensive parks were retained, including 8 indicators in the field of safety, 6 indicators in the field of accessibility, and 13 indicators in the field of service effectiveness.

Construction of Multi-purpose Hazard Information Map Based on Digital Image Using Geospatial Information (지형공간정보를 활용한 수치영상기반의 다목적 재해정보지도 구축)

  • Yun, Hee-Cheon;Min, Kwan-Sik;Kim, Min-Gyu
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.3
    • /
    • pp.91-101
    • /
    • 2010
  • As global warming has caused the number of abnormal changes in climate to increase throughout the world, much damage has occurred recently in Korean Peninsula which results from unexpected heavy rains, landslides, and floods from typhoons. To prevent and cope with these annually repeated natural hazards, the overall improvements are needed, including systematic management of the existing natural hazard information and improvement of hazard information. In this study, multi-purpose hazard information map based on digital image was constructed as an effective way to enhance hazard management considering regional characteristics and hazard response capabilities in the field. Multi-purpose hazard information map with a new concept by fusion of geospatial information and hazard attribute information is able to support quick decision for hazard management making and development of hazard information system.

Analysis of Performance-based Design Guides of Smoke Control System (성능위주 연기제어 설계지침 분석)

  • Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.6-13
    • /
    • 2016
  • With regard to smoke control system, the design guidelines of smoke exhaust for accommodation and smoke control for evacuation stairs and vestibule has been proposed domestically, but after reviewing the applicability to modern buildings that tend to be larger, higher and complex, a smoke control system according to domestic design guidelines might have difficulty in securing the safety from smoke in a fire. Therefore, it is necessary to adopt the performance-based design of a smoke control system that can enhance the safety and integrate the smoke control functions and design depending on the characteristics of fire and building structure in the case of fire in a large, high-rise, and complex building. This study analyzed the domestic design guidelines of a smoke control system and this paper proposes the part requiring improvement, and examines the legal system and guidelines on performance-based design of smoke control system in foreign countries.

A Study on Heat and Smoke Exhaust Characteristics from the Subway Fire for Different Ventilation Modes (지하철 화재시 제연모드에 따른 열 및 연기 배출 특성 연구)

  • Chang, Hee-Chul;Yoon, Kyung-Beom;Park, Won-Hee;Kim, Tae-Kuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.37-42
    • /
    • 2008
  • This study is focused on the numerical predictions for different smoke-control ventilation modes for the subway fire. Smoke-control ventilation mode in the domestic platform is that exhausting for the smoke detected zones while supplying air or stopping any ventilation for other zones in the platform. Three cases of smoke control ventilation modes are considered. First and second case are present running smoke control mode in Korea. The third is that smoke-control ventilation fans equipped in the platform are operated in first 4 minute(platform evacuation time, NFPA130) since then the fans equipped in the platform are stopped and the fans equipped in the tunnels are operated. Distributions of heat, carbon monoxide and visible range are compared at a height of 1.7m(passenger breath/sight height) above the platform. The numerical results show that air supply fan operation in the platform causes the smoke disturbance and a rapid spread of the smoke. The switch-operation with fans in both the platform and tunnel are better than operation with only platform fans in smoke rejection efficiency.

A Study on the Fire Alarm System of Vertical Fire Spread Structure by Using FDS (FDS을 이용한 수직 연소확대 구조의 화재경보방식에 관한 연구)

  • Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.100-107
    • /
    • 2016
  • Today, high-rise buildings expected to meet various needs and improve the quality of frequency of fire and the potential risks are increasing. In particular, the fire spread risk in the vertical direction is increasing. As a result there is a problem with delays in the evacuation time of occupants. To overcome this problem, there is a need to consider the structure of the building and develop a system for the early detection of fire by applying a fire alarm system according to the risk ranking. Therefore, this paper describes the vertical fire spread characteristics of a multistory double-skin and stairs structure with risk. The data were compared with that from the national and international fire alarms as well as with. smoke density, smoke detectors, visibility, and CO concentration using FDS. A fire alarm system for each structure is proposed.

Study of the Characteristics of Smoke Spread by an Installing Smoke Barrier in Medium Length Road Tunnel (중규모 도로터널의 제연경계벽 설치에 따른 연기확산특성)

  • Baek, Doo-San;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.9-17
    • /
    • 2016
  • In the case of a medium length road tunnel, the installation of a smoke control facility is not mandatory so users can suffer considerable injuries if a fire breaks out. Therefore, this study analyzed the high-temperature air and toxic gas generated by fire proliferating with time when a smoke barrier is not installed and when the installation interval is 100, 150, 200, and 250 m through 3-dimensional numerical analysis, evacuation simulation, and Quantitative Risk Assessment Methodology targeting the medium length road tunnel. As a result, the diffusion of the high-temperature air and toxic gas occurring from the a fire was delayed when the smoke barrier was installed in a medium length road tunnel compared to that when it was not installed. In addition, when the installation interval of a smoke barrier was 100m and the numerical analysis target was 100m, the diffusion of high-temperature air and toxic gas generated by the fire was delayed more than in the other cases, which was most suitable for tunnel users to evacuate.

Numerical Analysis on Pressurization System of Smoke Control in Consideration of Stack Effect (연돌효과를 고려한 급기가압 제연시스템의 수치해석 연구)

  • Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-6
    • /
    • 2013
  • When the pressurization system that uses difference of pressure for smoke control is designed, the factors influencing on the pressure field in building should be applied to design process and the stack effect is one of the main factors. Numerical analysis based on network model in 20-story building is carried out to analyze the pressurization system of smoke control in consideration of stack effect. Calculations are conducted for three conditions, that is, stack effect only, pressurization only and stack effect plus pressurization. Results including the detailed pressure field and flow rate at each floor are represented and the stack effect are effectively visualized. Meanwhile, the pressure of stairwell is increased as much as the summation of the stack effect and pressurization, and the problem induced by rise of pressure is pointed out.

Optical Characteristics of Phosphorescent Materials with Water-based Ceramics (축광세라믹스의 광학적 특성에 관한 연구)

  • Fujita Akihiro;Kagami Shinya;Hur Man-Sung;Jones Mark I
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.42-46
    • /
    • 2005
  • This study is intended to examine the degree of phosphorescent luminance in proportion to the amount of phosphorescent pigments in the ceramic based coating. The results of this study were that the degree of phosphorescent luminance was Increased in proportion to the amount of phosphorescent pigments in the ceramic based coatings. Samples with more than $20\%$ of phosphorescent pigments exceeded the Japanese Industrial Standard for security signs. Luminance levels 10 times greater than the KS and JIS standard were obtained with a concentration of $50\%$. The luminance increased initially with the number of applications of the ceramic based coating but there was no further increase for more than 4 applications. The water-based phosphorescent ceramics developed here are made entirely of inorganic materials and do not generate toxic gases. The optical characteristics of these materials makes them suitable for use in phosphorescent emergency exit signs in place of the traditionally used vinyl chloride materials.

A Study on a PCB Manufacturing Plant's Fire Risk Assessment due to the Mitigation of Fire Protection Zone and an Improvement Way through Estimation of Sprinkler Demand Water Flow Rate (방화구획 완화에 따른 PCB공장의 화재위험평가 및 스프링클러 요구살수유량 산정을 통한 기준개선안에 관한 연구)

  • Oh, Chan-Wook;Oh, Ryun-Seok;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.56-62
    • /
    • 2019
  • A sprinkler is a fire extinguishing equipment installed in a protected area where a detector or head detects a fire and automatically puts out the fire. However, the Ministry of Land, Infrastructure and Transport's "Regulations on Building Evacuation and Fire Protection Standards, etc." stipulate that fire compartment area should be reduced to three times by installing sprinkler facilities in the case of factories and warehouses. In this study, fire hazard was analyzed for a real PCB factory which mitigated the fire protection zone by sprinkler installation, and the head opening characteristics of sprinkler facilities through computer simulation, installation standards of sprinkler facilities, thermal performance, operating range, and the amount of water sprayed to identify the problems of operation of sprinkler facilities in case of fire, and to suggest the grounds such as required sprinkling flow rate for system improvement.