• Title/Summary/Keyword: 피난주거

Search Result 32, Processing Time 0.034 seconds

A Study on the Analysis of Evacuation Risk by Building Application for Fire Safety (화재안전을 위한 건축물 용도별 피난리스크 분석에 관한 연구)

  • Jin, Seung-hyeon;Koo, In-Hyuk;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.164-165
    • /
    • 2021
  • In Korea, in the case of fire scenarios in performance design, it is assumed that the sprinkler is not working. In addition, it does not applicate various fire conditions. Therefore it is not enough that the accuracy about fire scenario. In foreign countries, reseach is being conducted to predict the casualities that can occur due to fire in the building space through statistical risk analysis. Also, research is consistently conducting for design that consider the sprinker probability of operation. Therefore, to analyze the fire risk of each building in Korea, the risk was analyzed using statistical data. As a result, the risk of casualties that can occur for each building use was analyzed as 0.6(persons/cases) for residential buildings, 0.25(persons/cases) for sales facilities, and 0.12(persons/cases) for buisiness facilities.

  • PDF

Analysis of fires case through on-field survey of residential and commercial building in Ulsan (울산 주상복합건물 현장조사를 통한 화재사례 분석)

  • Cho, Hwi-Je;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.84-85
    • /
    • 2021
  • The fire that broke out in a residential and commercial complex in Ulsan in October 2020 was large, but no deaths occurred. For this reason, there was a difference from the previous cases, so it was analyzed through field survey. The fire was expanded to the entire building by aluminum composite panels constructed by external heat method and SMC panels in evacuation safety zones, and fire was expanded to nearby mart due to wind on the day of the fire, and there were many evacuation spaces such as 15th, 28th, and rooftop heliports.

  • PDF

Prediction of a Debris Flow Flooding Caused by Probable Maximum Precipitation (가능 최대강수량에 의한 토석류 범람 예측)

  • Kim, Yeon-Joong;Yoon, Jung-Sung;Kohji, Tanaka;Hur, Dong-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.2
    • /
    • pp.115-126
    • /
    • 2015
  • In recent years, debris flow disaster has occurred in multiple locations between high and low mountainous areas simultaneously with a flooding disaster in urban areas caused by heavy and torrential rainfall due to the changing global climate and environment. As a result, these disasters frequently lead to large-scale destruction of infrastructures or individual properties and cause psychological harm or human death. In order to mitigate these disasters more effectively, it is necessary to investigate what causes the damage with an integrated model of both disasters at once. The objectives of this study are to analyze the mechanism of debris flow for real basin, to determine the PMP and run-off discharge due to the DAD analysis, and to estimate the influence range of debris flow for fan area according to the scenario. To analyse the characteristics of debris flow at the real basin, the parameters such as the deposition pattern, deposit thickness, approaching velocity, occurrence of sediment volume and travel length are estimated from DAD analysis. As a results, the peak time precipitation is estimated by 135 mm/hr as torrential rainfall and maximum total amount of rainfall is estimated by 544 mm as typhoon related rainfall.

Basic Study for performance Improvement of Fire Detectors System at Domestic Apartment Buildings (국내 공동주택 화재감지시스템의 성능개선을 위한 기초연구)

  • Son, Bong-Sae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.533-538
    • /
    • 2014
  • This study examines the performance of and searches for improvements to the existing automatic fire detection systems installed at domestic apartment buildings as a basic study for development of intelligent fire detection systems specifically for apartments. Thus, this study aims to find out the problems in performance and maintenance of the existing fire detectors installed at apartment buildings which is the prerequisite process for development of intelligent fire detection system for that specific application. It is also found impossible to check whether or not the detectors installed at each apartment are in an operational state at normal times. This study finds that it is desirable to replace the slow-sensing heat detectors by a smoke and single smoke detectors which can detect a fire at its early stage in an effort to improve the problems of fire detectors installed at apartment buildings presently. Because we need to the independence fire detection system of apartment building.

Improvement for BF (Barrier Free) Certification to Ensure Disaster Safety for the People with Disabilities (장애인 재난 안전확보를 위한 BF(Barrier Free) 인증제도의 개선 방향)

  • 박진용
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.230-233
    • /
    • 2023
  • 우리 헌법은 인간의 존엄과 가치 그리고 행복을 추구할 권리를 보장하고 있으며, 편의증진법과 교통약자법을 통해 장애인등이 교통수단, 여객시설 및 도로 등을 비장애인들과 차별 없이 이용하여 이동하고, 도로와 대중교통수단, 공공 건축물과 주거 등 생활 필수시설에 자유롭게 접근하기 위한 접근권을 보장하고 있다. 우리나라는 이동권의 보장을 편의시설 제도라는 독자적인 체계를 통해 이루어지고 있으며, 이를 실질적으로 보장하기 위하여 장애물 없는 환경 인증 제도(BF 인증제도)를 도입하였다. 시행 15년을 맞은 BF 인증제도는 양적으로는 많은 발전을 가져왔지만, 질적으로 특정 건축물 등 일부에 대한 인증 편중 현상이 있으며 안전취약계층에 대한 재해 안전확보에 대한 고려가 포함되지 않아 부진정한 이동성과 접근성의 보장이라는 한계를 가지고 있다. 이동권 보장이 얼마나 잘 이루어지느냐는 그 나라의 사회 안전망이 얼마나 잘 갖추어져 있는지 판단하는 척도라 할 것이며, 따라서 이러한 이동권 보장은 위험상태에서의 안전한 피난을 함축하고 있으며 중첩적으로 국가의 기본권 보호 의무의 이행과 관련된다. 이에 따라 이동권과 접근권의 증진을 위한 BF 인증 규정을 안전 규범으로 보완하여 장애인과 비장애인이 사회의 일원으로서 평등한 인격적 주체로 공동체에 기여하는 안전한 사회적 환경의 조성이 긴절히 요청된다고 할 수 있다.

  • PDF

Evaluation on Transverse Load Performance of Lightweight Composite Panels (경량 복합패널의 분포압 강도 성능 평가)

  • Kang, Su-Min;Hwang, Moon-Young;Kim, Sung-Tae;Cho, Young-Jun;Lee, Byung-yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.146-157
    • /
    • 2018
  • Over the last 10 years, the number of disasters has been increasing in Korea. As a result, the need for temporary residences or shelters for disaster conditions is increasing. In this study, post-disaster refugees housing was developed using lightweight composite panels that are lighter than the materials that make up the existing shelter. To accomplish this, the structural performance of the lightweight composite panel was validated. Among the performance tests on the panels, the transverse load test was conducted according to the ASTM E 72 criteria. As a result of the experiment, when each specimen was subjected to a uniformly distributed load, the allowable load was determined according to the span. All the experiments were ended due to a loss of adhesive at the junction of the skin and core. Further analysis was conducted to calculate the shear stress when the junction was dropped. The mean shear stress at the adhesive surface of a specimen, 150 mm and 200 mm in thickness, was 0.0170MPa and 0.0156MPa, respectively. This suggests that similar values were obtained from panels of equal thickness. In addition, this stress provides a criterion of judgment that could be used to inspect the structural performance of the panels. The performance of the panel was evaluated based on the allowable load, but it may be possible to increase the strength of the lightweight composite panel by improving the joining method to avoid separation from the junction.

Evaluation on In-plane Shear Strength of Lightweight Composite Panels (경량 복합패널의 면내 전단 성능 평가)

  • Hwang, Moon-Young;Kang, Su-Min;Lee, Byung-yun;Kim, Sung-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.9-20
    • /
    • 2019
  • The number of natural disasters in Korea, such as earthquakes, is increasing. As a result, there is growing need for temporary residences or shelters for disaster conditions. The aim of this study was to produce post-disaster refugees housing differentiated from existing shelters using lightweight composite panels. To accomplish this, the structural performance of lightweight composite panels was validated, and an in-plane shear strength test was conducted according to the ASTM E72 criteria among the performance test methods for panels. As a result of the experiment, the maximum load for each specimen under an in-plane shear load was determined. All the experiments ended with the tear of the panel's skin section. The initial stiffness of the specimens was consistent with that predicted by the calculations. On the other hand, local crushing and tearing, as well as the characteristics of the panel, resulted in a decrease in stiffness and final failure. Specimens with an opening showed a difference in stiffness and strength from the basic experiment. The maximum load and the effective area were found to be proportional. Through this process, the allowable shear stress of the specimens was calculated and the average allowable shear stress was determined. The average ultimate shear stress of the lightweight composite panels was found to be $0.047N/mm^2$, which provides a criterion of judgement that could be used to expect the allowable load of lightweight composite panels.

Effects on Resident of human body at fire outbreak for apartment building using CFAST (화재 시뮬레이션을 이용한 공동주택 화재발생시 거주자의 인체에 미치는 영향)

  • Park, Joo-Won;Kwon, Jin-Suk;Choi, Jae-Hyouk
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.189-189
    • /
    • 2011
  • 최근 공동주택은 보편적인 도시주거 유형으로 자리매김 하고 있지만, 성장 위주의 경제 산업 정책에 따른 안전의식미약, 사회구조개편에 따른 급격한 증가, 생활환경 변화와 에너지 사용 증가 등 화재 유발인자의 다양화로 인해 인적 물적 피해가 증가하고 있는 실정이다. 특히 다른 건물들과는 달리 공동주택의 거주자가 유아, 노인, 신체장애자 등 다양한 인적 구성의 형태로 이루어져 있어서 화재 발생 건수에 비해 인명피해가 월등히 높은 편이다. 공동주택에서의 화재에 대한 위험성을 인식하고, 그에 대한 인적 물적 피해를 최소화하기 위한 대책 마련이 시급하다. 본 논문은 CFAST(Consolidated Model of Fire Growth and Smoke Transport)를 사용하여 공동주택을 대상으로 실물 화재 실험을 실시하고 공간화재에서의 화재 성상을 파악하여 화재 시 개구부의 개폐 여부에 따라 발생되는 산소와 이산화탄소의 농도와 온도가 인체에 미치는 영향에 대해 알아본다. 개구부를 개방 했을 경우에 외부창문의 개폐 여부에 상관없이 모든 방의 온도 분포가 뚜렷하게 나타났지만 개구부를 폐쇄 할 경우에는 발화지점인 거실의 온도 분포만 나타났다. Flashover현상과 Back Draft현상은 개구부의 개폐여부에 상관없이 외부 창문을 폐쇄 했을 경우에 나타났지만 특히 모든 개구부와 외부창문을 폐쇄 했을 경우에 더욱 뚜렷하게 나타났다. 각 실은 점화 후 4분경에 최고 온도를 보였으며 다른 방에 비해 발화지점인 거실의 온도가 가장 높게 나타났다. 온도에 의해서는 두 가지 영향이 일어날 수 있는데, 하나는 비교적 장시간에 걸쳐 발생하는 열응력이고, 다른 하나는 짧은 시간에 발생할 수 있는 화상이다. 만약 피부온도가 $45^{\circ}C$에 이르면 인체는 고통을 느끼게 되며, 이보다 더 높은 온도에서는 깊은 피부조직까지 손상을 줄 수 있다. 움직이지 않는 사람에 대한 고통 유발 임계온도는 약 $200^{\circ}C$이며, 인체는 땀의 발산으로 온도에 대한 내성이 증가하지만 이체가 장시간 열을 받으면 사망에 이를 수 있다. 결론적으로 공동 주택을 대상으로 CFAST를 이용해 분석한 결과 플래쉬오버 현상으로 인해 화재가 성장하여 급격히 온도가 상승하다가, 산소 부족으로 인해 화재가 성장하지 않고 온도가 떨어지는 것을 알 수 있다. 화재 시 온도, 산소, 이산화탄소를 고려하였을 때 약 3분 이내에 대피해야 온도 및 가스로 인한 피해를 줄일 수 있을 것으로 판단된다.

  • PDF

A study on the Combustion Characteristics of Wall Paper (내장벽지의 연소특성에 관한 연구)

  • Oh, Kyu-Hyung;Choi, Yeon-Yi;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.90-97
    • /
    • 2007
  • Combustion characteristics and toxicity of combustion gas of wallpaper samples were analyzed to evaluate the fire risk of wallpaper furnished in living space. In this study ash residue ratio was measured with high temperature electric furnace, and thermal analysis was carried out with TGA. Combustion time and smoke concentration were measured with cone heater and combustion gas analyzer. Smoke density of samples was measured using smoke chamber of ASTM E 662. The experimental results were showed as followings. Pyrolysis of silk wallpaper started at lower temperature compared to the other samples. It means that the silk wallpaper can be ignited at low heat flux and will have more fire risk than the others. Ignition time by radiation heat flux of silk wallpaper is shorter compared to the other samples, so evacuation time must be reduced. In the case of vinyl coated silk wall paper, carbon mono oxide concentration is the highest and the toxicity and damage effect to consciousness was stronger compared to the other samples. Smoke density of silk wall paper and fire retardant mixed coated silk wall paper were very high due to vinyl coating.

A Comparative Study on the Spatial Layout Characteristics of Modern Apartment Floor Plan and 'Standard Korea Traditional-Houses Floor Plan' (현대 아파트 평면도와 한옥표준평면도의 공간배치 특성 비교 연구)

  • Hwang, Yong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.271-278
    • /
    • 2019
  • This study compares the space depth and layout of a modern apartment floor plan (MAFP) and the standard floor plan of traditional Korean houses (STKHs), which has preserved the traditional beauty of Korea. Space Syntax was applied to compare the MAFP and STKH. The space within MAFP was more divided into many spaces than the STKH. In both types of floor plans, the living room space had the highest degree of integration and was used for central functions in the each floor plan. The STKH and the space in the MAFP have more segregated space than integrated space. In the STKH, the master bedroom and other rooms were found to be segregated space. However, the master bedroom of the MAFP was highly integrated space. The function of the thet maru has been greatly reduced in the STKH, and the numaru was classified as a highly segregated space. The evacuation space was the most segregated space in the MAFP. The STKH has been adapted and changed according to the trends of the times, and the MAFP reflects our traditional living habits.