• 제목/요약/키워드: 플룸

검색결과 152건 처리시간 0.025초

다공확장벽을 이용한 플룸간섭의 제어 (Control of Plume Interference Using a Porous Extension)

  • Young-Ki Lee;Heuy-Dong Kim
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.95-98
    • /
    • 2003
  • The physics of the plume-induced shock and separation particulary at a high plume to exit pressure ratio and supersonic speeds up to Mach 3.0 with aid without a passive control method, porous extension, were studied using computational techniques. Mass-averaged Navier-Stokes equations with the RNG k-$\varepsilon$ turbulence model were solved using a fully implicit finite volume scheme and a 4-stage Runge-Kutta method. The courol methodology for plume-afterbody interactions is to use a perforated wall attached at either the nozzle exit or the edge of the missile base. The Effect of porous wall length on plume interference is also investigated. The computational results show the main effect of the porous extension on plume-afterbody interactions is to in the plume from strongly underexpanding during a change in flight conditions. With control, a change in porous extension length has no significant effect on plume interference.

  • PDF

선박용 주방후드 환기시스템에 관한 수치해석 (Numerical Analysis of the Kitchen Hood Ventilation System for Marine Environment)

  • 이중섭
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.96-101
    • /
    • 2015
  • This study regards distributions of flow in the ventilation system used in the kitchen hood in a ship. In this study, for describing the flow in the ventilation system, three-dimensional steady-state turbulence was assumed for the governing equation. When the plume was formed, three gases, CO, CO2, and HCL, in the flow field of the hood were considered as the plume, and it was assumed that the sum of concentrations of the gases was 100%. As a result, it could be confirmed that the plume was smoothly discharged when the flow rate of the supply was ten times lower than that of the exhaust.

로켓 배기플룸에 관한 3차원 수치해석 (Three-Dimensional Computations of Rocket Exhaust Plume)

  • 김영목
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 추계 학술대회논문집
    • /
    • pp.71-76
    • /
    • 1999
  • The base flow regions of a three-body sounding rocket containing multiple exhaust plumes were numerically investigated in three dimensions for a free stream Mach number of 2.7 at flight altitude 18.5 km. The flowfields were calculated using the full compressible Navier-Stokes equations with an one-equation turbulence model of Baldwin-Earth. The present calculations were executed based upon a chemically frozen, single perfect gas model assumption. Due to the symmetry of the three-body rocket of each single nozzle, only one fourth of the computational domain was considered for the analysis. The results indicate that a babe heating effect is not considerable due to the small expansion of the plumes. In the base, however, a low speed recirculating flow dominates the region.

  • PDF

플룸에 의한 액체로켓 저부면 복사 가열 해석 (Numerical Analysis on Radiative Heating of a Plume Base in Liquid Rocket Engine)

  • 손채훈;김영목
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 추계 학술대회논문집
    • /
    • pp.65-70
    • /
    • 1999
  • Radiative heating of a liquid rocket base plane due to plume emission is numerically investigated. Calculation of flow and temperature fields around rocket nozzle precedes and thereby realistic plume shape and temperature distribution inside the plume are obtained. Based on the calculated temperature field, radiative transfer equation is solved by discrete ordinate method. The averaged radiative heat flux reaching the base plane is about $5kW/m^2$ at the flight altitude of 10.9km. This value is small compared with radiative heat flux caused by constant-temperature (1500K) plume emission, but it is not negligibly small. At higher altitude (29.8km), view factor between the babe plane and the exhaust plume is increased due to the increased expansion angle of the plume. Nevertheless, the radiative heating disappears since the base plane is heated to high temperature (above 1000K) due to convective heat transfer.

  • PDF

IR 신호 분석을 위한 비행 조건에 따른 노즐 열유동장 해석 (Numerical Analysis of Nozzle Plume Flow-Fields at Various Flight Conditions for Infrared Signature Investigation)

  • 전수환;양영록;문혁;김준영;명노신;조태환
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.601-604
    • /
    • 2011
  • Plume flow-fields of aircraft nozzles are numerically investigated at various flight conditions for infrared signature analysis. A mission profile of subsonic unmanned combat aerial vehicle is considered for the requirement of each mission, associated engine and nozzles are selected through a performance analysis. Numerical results of nozzle plume flow-fields using a CFD code are analyzed in terms of thrust, maximum temperature. It is shown that maximum temperature increase for lower altitude and higher Mach number.

  • PDF

DSMC 방법 SMILE 코드를 이용한 Rothe 마이크로 노즐 시뮬레이션 (Simulation of Rothe Micronozzle Using DSMC method SMILE code)

  • 최영인;김영훈;옥호남;김인선
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.30-33
    • /
    • 2007
  • 고고도에서의 노즐 플룸 해석에 가장 일반적으로 사용되는 CFD 기법은 DSMC 방법이다. 본 논문에서는 DSMC 방법으로 만들어진 러시아 ITAM 연구소의 SMILE 코드를 사용하여 Rothe 마이크로노즐 내부유동을 시뮬레이션 하였다. 또한, SMILE 코드 결과의 유효성(신뢰성)을 확보하기 위하여 레이놀즈 수에 따른 노즐 내부 centerline의 온도를 Rothe의 실험치와 비교하여 검증하였다.

  • PDF

항공기 IR 신호 분석을 위한 다양한 비행 조건에서의 노즐 열유동장 해석 (COMPUTATIONAL INVESTIGATION OF NOZZLE FLOWFIELDS AT VARIOUS FLIGHT CONDITIONS FOR AIRCRAFT INFRARED SIGNATURE ANALYSIS)

  • 전수환;양영록;문혁;명노신;조태환
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.15-21
    • /
    • 2011
  • Aerothermodynamic flowfields of aircraft engine nozzles are computationally investigated at various flight conditions for infrared signature analysis. A mission profile of subsonic unmanned combat aerial vehicle is considered for the case study and associated engine and nozzles are selected through a performance analysis. Computational results of nozzle and plume flowfields using a density-based CFD code are analyzed in terms of thrust, maximum temperature, length and optical thickness of plume. It is shown that maximum temperature, length, and optical thickness of nozzle plume increase for lower altitude and higher Mach number.

공개소스프로젝트를 이용한 사이버물리시스템 데이터분석아키텍처 (CPS Data Analysis Architecture using Open Source Projects)

  • 임유진;최은미
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2013년도 추계학술발표대회
    • /
    • pp.172-175
    • /
    • 2013
  • 사이버물리시스템(CPS)은 실시간 제약으로 타이밍에 민감한 특징이 있으며, 산업 영역에 적용시 시스템 동작과 안전필수 로그의 특정한 패턴을 나타내는 대용량의 실시간 데이터를 생성시킨다. 본 논문은 공개소스프로젝트인 하둡에코시스템을 이용한 CPS 데이터분석 아키텍처를 소개한다. CPS 처리의 특징 때문에 그 대용량의 데이터 처리는 하나의 머신에서 분석될 수 없으므로, 하둡에코시스템을 통하여 실시간 기반으로 생성되는 데이터를 저장하고 처리하는 시스템 아키텍처를 제안한다. 하둡분산파일시스템(HDFS)은 거대한 CPS 데이터의 저장을 위한 기본 파일시스템이고, 하이브는 데이터웨어하우징 처리를 위한 CPS 데이터분석에 사용된다. 플룸은 서버들로부터 데이터를 수집하고 HDFS에서 그 데이터를 처리하기 위해 사용되며, Rhive는 데이터 마이닝과 분석을 적용하기 위해 사용된다. 이러한 아키텍처를 개관하고, 또한 효과적인 데이터 분석을 위해 사용한 시스템 설계 전략을 소개한다.

해양 지구물리 탐사를 이용한 해저열수광상 부존지역 탐지 방법 (The Exploration Methodology of Seafloor Massive Sulfide Deposit by Use of Marine Geophysical Investigation)

  • 김현섭;정미숙;김창환;김종욱;이경용
    • 지구물리와물리탐사
    • /
    • 제11권3호
    • /
    • pp.167-176
    • /
    • 2008
  • 태평양 해양 지각판과 인도-호주 대륙 지각판간 섭입작용에 의해 형성된 남태평양 라우분지는 활동성 후열도분지로서 해저열수광상이 부존할 가능성이 매우 높은 지역이다. 한국해양연구원은 라우분지를 대상으로 다중음향측심장비(EM120)을 이용하여 정밀지형조사를 실시하여 열수활동이 활발할 것으로 예측되는 해저 지각 확장축 주변지역 (FRSC)과 해저화산 지역(MTJ)을 선별하였다. 또한, 표층 및 심해견인 자력탐사결과를 토대로 저 자기이상 현상을 나타내는 열수광체 지역을 선정하였다. 표층 및 심해 견인 자력탐사 결과 해령에서 주로 나타나는 Central Anomaly Magnetization High(CAMH)가 FRSC-2 지역에서 관측되었으며, MTJ-1 지역에서는 열수분출작용으로 추정되는 저자화이상이 발견되었다. CTD 시스템을 이용하여 열수 플룸 추적자인 투명도, 수소이온(pH), 미생물생체량(ATP), 메탄$(CH_4)$농도를 실시간으로 측정한 결과 FRSC-2와 MTJ-1 지역은 현재 매우 활발한 화산 활동이 진행되고 있음을 알 수 있었다. 이 지역에서 채취한 열수분출공과 기반암 시료는 이 지역에서 열수활동이 진행되었거나 진행되고 있으며, 실제로 열수 광체가 부존하고 있음을 확인할 수 있었다. 첨단 해저면 영상장비를 사용하지 않고도, 전통적인 해양 지구물리탐사 방법이 해저열수광상의 탐지에 비용 효과적인 탐사방법임을 알 수 있었다.

엇갈리게 배열된 두 개의 수평관에서 수평 피치-직경비에 따른 자연대류 열전달 영향 (Effect of Horizontal Pitch-to-Diameter Ratio on the Natural-Convection Heat Transfer of Two Staggered Cylinders)

  • 채명선;허정환;정범진
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.259-268
    • /
    • 2012
  • 엇갈리게 배열된 두 개의 수평관의 수직 이격거리($P_v$/D)와 수평 이격거리($P_h$/D)를 변화시키며 자연대류 열전달을 실험적으로 측정하였다. 열/물질전달의 상사성을 이용하여 물질전달 실험을 수행하였고 난류영역까지 확장하였다. Pr 수 2,014, RaD 수 $1.5{\times}10^8\sim2.5{\times}10^{10}$, $P_v$/D는 1.02~5, $P_h$/D는 0~2 범위에서 수행하였다. 하단 수평관의 물질전달은 단일 수평관 상관식의 예측치와 일치하였다. 상단 수평관의 물질전달은 $P_v$/D가 작을 때, 하단 수평관에서 상승하는 플룸의 예열영향(Preheating effect)으로 인해 감소하였고, $P_h$/D가 증가하면 급격히 상승하였다. 그러나 $P_v$/D가 클 때, 상단 수평관의 물질전달은 하단 수평관의 플룸 속도영향으로 인하여 단일 수평관보다 컸고, $P_h$/D가 증가함에 따라 완만하게 감소하였다. $P_h$/D가 매우 증가하여도 굴뚝효과(Chimney effect)와 측면유동효과(Side flow effect) 인하여 상단 수평관의 열전달이 하단 수평관의 열전달보다 크게 나타났다.