• 제목/요약/키워드: 플랜트 응답

검색결과 96건 처리시간 0.024초

해양플랜트 설비 Corrugated Blast Wall의 폭발 충격응답 인자 특성에 관한 파라메트릭 연구 (Parametric Study on Explosion Impact Response Characteristics of Offshore Installation's Corrugated Blast Wall)

  • 김봉주;김병훈;손정민;백점기;서정관
    • 한국해양공학회지
    • /
    • 제26권3호
    • /
    • pp.46-54
    • /
    • 2012
  • More than 70% of the accidents that occur on offshore installations stem from hydrocarbon explosions and fires, which, because they involve blast effects and heat, are extremely hazardous and have serious consequences in terms of human health, structural safety, and the surrounding environment. Blast barriers are integral structures in a typical offshore topside module to protect personnel and safety critical equipment by preventing the escalation of events caused by hydrocarbon explosions. Many researchers have shown the adequacy of the simple design tool commonly used by the offshore industry for the analysis and design of blast walls. However, limited information is available for corrugated blast wall design with explosion impact response characteristics. Therefore, this paper presents a parametric study on the explosion impact response characteristics of an offshore installation's stainless steel corrugated blast wall. This paperalso investigates and recommends design parameters for the structural design of a corrugated blast wall based on a nonlinear structural analysis of experiential results.

유도전동기의 위치제어 시스템을 위한 가변구조제어기의 떨림저감 (Chattering Reduction of Variable Structure Controller for Position System of Induction Motor)

  • 김영조;김현중
    • 전자공학회논문지T
    • /
    • 제35T권2호
    • /
    • pp.39-47
    • /
    • 1998
  • 가변구조 제어기는 이론적으로 빠른 응답특성을 가지며 오버슈트가 없고 외란이나 파라미터 변동에 강인한 제어기로 알려져왔다. 그러나 가변구조 제어기는 모델링과정에서 무시된 플랜트의 고주파 동특성을 여기할 수 있고, 또 시스템을 구성하는 소자들에 손상을 줄 수 있는 채터링현상이 발생하기 때문에 산업현장에서 널리 적용되지 못하고 있다. 본 논문에서는 채터링을 저감시키기 위한 개선된 가변구조 제어기를 제안하고 유도전동기의 위치제어에 적용한다. 기존의 가변구조 제어기는 한 개의 스위칭면을 중심으로 고주파 스위칭을 행하여 시스템의 구조를 절환한 반면에, 개선된 가변구조 제어기는 한 개의 면 대신 슬라이딩 영역을 이루기 위해 두 개의 스위칭면을 가지며 이 영역 내에서 저주파 스위칭으로써 시스템 구조를 절환하게 된다. 그러므로 제안된 알고리즘은 기존의 가변구조 제어기가 가지는 빠른 응답성이나 강인성을 유지하면서 고주파 채터링을 저감시키는 특징을 가지며 전동기정수 변동에도 양호하게 동작하고 있다. 제안하는 제어기의 타탕성을 확인하기 위해 실험을 행하였다.

  • PDF

해양플랜트 구조물의 화재 사고 시 PFP 효과를 고려한 비선형 구조응답 해석 기법에 대한 연구 (Methods for Nonlinear Structural Response Analysis of Offshore Structures with Passive Fire Protection under Fires)

  • 김정환;이동훈;하연철;김봉주;서정관;백점기
    • 한국해양공학회지
    • /
    • 제28권4호
    • /
    • pp.294-305
    • /
    • 2014
  • In offshore structures, fire is one of the most important hazardous events. The concern of fires has recently been reflected in the rules and quantified risk assessment based design practice. Within the framework of quantified risk assessment and the management of offshore installations, therefore, more refined computations of the consequences or hazardous action effects due to fire are required. To mitigate fire risk, passive fire protection(PFP) is widely used on offshore structures. This study presents methods for a nonlinear structural response analysis considering the PFP effects under fires. It is found that a structural response analysis is most likely to use valuable technology for the optimization and design of offshore structures with PFP. Thermal and structural response analyses have been performed using LS-DYNA and FAHTS/USFOS. The results of these structural response analyses are compared with each other.

물 분사 펌프의 동특성 분석 (Analysis of Dynamic Characteristics of Water Injection Pump)

  • 이종명;이정훈;하정민;안병현;김원철;최병근
    • 대한기계학회논문집A
    • /
    • 제37권12호
    • /
    • pp.1483-1487
    • /
    • 2013
  • 물 분사 펌프는 심해 유정의 시추작업 후 유정 내 높은 압력으로 인하여 원유를 1 차 생산하고 이후 유정 내 압력이 낮아져 유정 자체의 압력 만으로 생산이 어려울 때 고압의 해수를 유정에 주입해 회수율을 높이는 해양플랜트에서 사용되는 핵심 기자재이며, 여러 기업에서 개발 중이다. 본 논문은 회전체의 동특성 을 분석하여 베어링 강성에 따른 고유진동수 변화분석, 운전속도 변화에 따른 고유진동수의 변화와 위험속도 분석, 안정성 평가, 불평형 응답을 통하여 변위와 틈새 관계 분석 등의 수학적 해석을 통하여 개발 중의 제품의 신뢰성에 기여하였다.

다수기의 확률론적 지진안전성 평가를 위한 지진손상 상관계수의 적용 (Feasibility Study of Seismic Probabilistic Risk Assessment for Multi-unit NPP with Seismic Failure Correlation)

  • 임승현;곽신영;최인길
    • 한국전산구조공학회논문집
    • /
    • 제34권5호
    • /
    • pp.319-325
    • /
    • 2021
  • 후쿠시마 원전사고 발생으로 다수기의 지진안전성에 관한 연구의 필요성이 부각되었다. 한 부지에 건설된 원자력발전소의 경우 유사한 지진응답을 보이기 때문에 적게나마 원자력발전소 SSCs간의 지진손상에 대하여 상관성이 존재하므로 합리적 지진안전성 평가를 위하여 지진손상 상관성을 고려하여야 한다. 본 연구에서는 쌍둥이 호기의 필수전원상실사건에 대하여 확률론적 지진안전성 평가를 수행하였다. 적절한 지진손상 상관계수를 도출하기 위하여 확률론적 지진응답해석을 수행하여 적용하였다. External Event Mensuration System 프로그램을 활용하여 다수기의 필수전원상실사건의 고장수목을 구성하여 지진취약도 및 지진리스크를 분석하였다. 또한 SSCs간의 지진손상 상관성을 완전독립 및 완전종속으로 고려하여 비교 분석을 수행하였다.

PZT actuator를 이용한 외팔보의 능동진동제어 (Active control of vibration of cantilever beams using PZT actuators)

  • 신창주;홍진숙;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.247-252
    • /
    • 2008
  • This paper presents an active vibration control of cantilever beams under disturbances by a primary force. A direct velocity feedback control using a pair of PZT actuator and a velocity sensor is considered. Variation of the stability and performance with the locations of the sensor/actuator pair is investigated. It is found that the maximum gain varies with the locations of the sensor/actuator pair significantly. The maximum gain shows a symmetric distribution along the beam length with respect to the center point, although the boundary condition of the beam is unsymmetric. The control performance is affected by the location of the primary force as well as the location of the sensor/actuator pair. The active control system can more effectively reduce the vibration when the primary force is located close to the fixed boundary.

  • PDF

디지털 조속기의 성능 시험을 위한 HILS 시스템 개발에 관한 연구 (A Study on the Development of HILS System for Performance Test of Digital Governor)

  • 장민규;조성훈;전일영;안병원;박영산;배철오;이성근;김윤식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.317-319
    • /
    • 2003
  • HILS(Hardware In-the Loop Simulation)은 임베디드(Embedded) 시스템의 개발과 시험에 많이 이용된다. 임베디드(Embedded) 시스템은 시스템의 운전 환경에서 쉽고, 철저하게 그리고 반복해서 시험할 수 없을 때 사용된다. HILS는 빠르고 경제적으로 제품을 개발하는데 유효하다. 또한 생산품이 생산을 시작한 후에 심각한 문제점들이 발견될 가능성을 상당히 줄여주어 생산품 개발 시간동안에 설계 최적화와 하드웨어/소프트웨어 디버깅을 실행하는데 도움을 준다. 본 연구는 Digital Governor의 성능을 확인하기 위해 스팀터빈 플랜트와 동기 발전기를 포함한 시뮬레이터를 HIL(Hardware In-the Loop Simulator)로 구현하였으며, 실시간으로 시스템의 응답을 확인할 수 있도록 소프트웨어로 구성하였다.

  • PDF

DC 서보모터의 속도제어를 위한 GAs의 PID 계수조정에 관한 연구 (A Study on the PID Order tuning by GAs for Velocity Control of DC Servo Motor)

  • 박재형;김성곤;이상관
    • 한국정보통신학회논문지
    • /
    • 제9권8호
    • /
    • pp.1840-1846
    • /
    • 2005
  • 본 논문에서는 유전 알고리즘을 사용하여 PID의 각 계수를 자동적으로 조정함으로써 DC 서보모터의 속도제어에 적용하였다. DC 서보모터는 산업현장 및 로봇분야에 널리 적용되고 있으며 적절한 제어성능을 얻기 위하여 많은 시행착오에 의한 다양한 제어방법이 사용되고 있다. 그러나 산업현장, 플랜트의 변화 및 외란에 강인한 제어알고리즘을 선택하기가 매우 어려우며 많은 시행착오를 통하여 원하는 계수값을 얻어 낼 수 있다. 따라서 본 논문에서는 이러한 문제점을 해결하고 DC 서보모터의 제어성능을 향상시키기 위하여 유전 알고리즘을 적용함으로써 우수한 응답특성을 얻을 수 있었다.

PZT Actuator를 이용한 외팔보의 능동진동제어 (Active Vibration Control of Cantilever Beams Using PZT Actuators)

  • 신창주;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제18권12호
    • /
    • pp.1293-1300
    • /
    • 2008
  • This paper presents an active vibration control of cantilever beams under disturbances by a primary force. A direct velocity feedback control using a pair of PZT actuator and a velocity sensor is considered. Variation of the stability and performance with the locations of the sensor/actuator pair is investigated. It is found that the maximum gain varies with the locations of the sensor/actuator pair significantly. The maximum gain shows a symmetric distribution along the beam length with respect to the center point, although the boundary condition of the beam is unsymmetric. The control performance is affected by the location of the primary force as well as the location of the sensor/actuator pair. The active control system can more effectively reduce the vibration when the primary force is located close to the fixed boundary.

업데이트된 집중질량스틱모델과 진동대실험 지진응답 비교 (Comparison of Seismic Responses of Updated Lumped-Mass Stick Model and Shaking Table Test Results)

  • 선휘창;홍상현;노화성
    • 한국지진공학회논문집
    • /
    • 제23권4호
    • /
    • pp.231-238
    • /
    • 2019
  • A conventional lumped-mass stick model is based on the tributary area method to determine the masses lumped at each node and used in earthquake engineering due to its simplicity in the modeling of structures. However the natural frequencies of the conventional model are normally not identical to those of the actual structure. To solve this problem, recently an updated lumped-mass stick model is developed to provide the natural frequencies identical to actual structure. The present study is to investigate the seismic response accuracy of the updated lumped-mass stick model, comparing with the response results of the shaking table test. For the test, a small size four-story steel frame structure is prepared and tested on shaking table applying five earthquake ground motions. From the comparison with shaking table test results, the updated model shows an average error of 3.65% in the peak displacement response and 9.68% in the peak acceleration response. On the other hand, the conventional model shows an average error of 5.15% and 27.41% for each response.