• Title/Summary/Keyword: 플라스틱 결함

Search Result 775, Processing Time 0.033 seconds

Adherence of Salivary Proteins to Various Orthodontic Brackets (다양한 교정용 브라켓 표면에 부착하는 타액단백질에 관한 연구)

  • Ahn, Sug-Joon;Ihm, Jong-An;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.443-453
    • /
    • 2002
  • The principal aims of this study were to identify the composition of salivary pellicles formed on various orthodontic brackets and to obtain a detailed information about the protein adsorption profiles from whole saliva and two major glandular salivas. Four different types of orthodontic brackets were used. All were upper bicuspid brackets with a $022{\times}028$ slot Roth prescription; stainless steel metal, monocrystalline sapphire, polycrystalline alumina, and plastic brackets. Bracket pelicles were formed by the incubation of orthodontic brackets with whole saliva, submandibular-sublingual saliva, and parotid saliva for 2 hours. The bracket pellicles were extracted and confirmed by employing sodium dodecyl sulfatepolyacrylamide gel electrophoresis, Western transfer methods, and immunodetection. The results showed that low-molecular weight salivary mucin, ${\alpha}-amylase$, secretory IgA (sIgA), acidic proline-rich proteins, and cystatins were attached to all of these brackets regardless of the bracket types. High-molecular weight mucin, which promotes the adhesion of Streptococcus mutans, did not adhere to uy orthodontic brackets. Though the same components were detected in all bracket pellicles, however, the gel profiles showed qualitatively and quantitatively different pellicles, according to the origins of saliva and the bracket types. In particular, the binding of sIgA was more prominent in the pellicles from parotid saliva and the binding of cystatins was prominent in the pellicles from the form plastic brackets. This study indicates that numerous salivary proteins adhere to the orthodontic brackets and these salivary proteins adhere selectively according to bracket types and the types of the saliva.

Effect of low temperature microwave irradiation on tunnel layer of charge trap flash memory cell

  • Hong, Eun-Gi;Kim, So-Yeon;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.261-261
    • /
    • 2016
  • 플래시 메모리 (flash memory)는 DRAM(dynamic racdom access memory)이나 SRAM(static random access memory)에 비해 소자의 구조가 매우 단순하기 때문에 집적도가 높아서 기기의 소형화가 가능하다는 점과 제조비용이 낮다는 장점을 가지고 있다. 또한, 전원을 차단하면 정보가 사라지는 DRAM이나 SRAM과 달리 전원이 꺼지더라도 저장된 정보가 지워지지 않는다는 특징을 가지고 있어서 ROM(read only memory)과 정보의 입출력이 자유로운 RAM의 장점을 동시에 가지기 때문에 활용도가 크다. 또한, 속도가 빠르고 소비전력이 작아서 USB 드라이브, 디지털 TV, 디지털 캠코더, 디지털 카메라, 휴대전화, 개인용 휴대단말기, 게임기 및 MP3 플레이어 등에 널리 사용되고 있다. 특히, 낸드(NAND)형의 플래시 메모리는 고집적이 가능하며 하드디스크를 대체할 수 있어 고집적 음성이나 화상 등의 저장용으로 많이 쓰이며 일정량의 정보를 저장해두고 작업해야 하는 휴대형 기기에도 적합하며 가격도 노어(NOR)형에 비해 저렴하다는 장점을 가진다. 최근에는 smart watch, wearable device 등과 같은 차세대 디스플레이 소자에 대한 관심이 증가함에 따라 투명하고 유연한 메모리 소자에 대한 연구가 다양하게 진행되고 있으며 유리나 플라스틱과 같은 기판 위에서 투명한 플래시 메모리를 형성하는 기술에 대한 관심이 높아지고 있다. 전하트랩형 (charge trap type) 플래시 메모리는 플로팅 게이트형 플래시 메모리와는 다르게 정보를 절연막 층에 저장하므로 인접 셀간의 간섭이나 소자의 크기를 줄일 수 있기 때문에 투명하고 유연한 메모리 소자에 적용이 가능한 차세대 플래시 메모리로 기대되고 있다. 전하트랩형 플래시메모리는 정보를 저장하기 위하여 tunneling layer, trap layer, blocking layer의 3층으로 이루어진 게이트 절연막을 가진다. 전하트랩 플래시 메모리는 게이트 전압에 따라서 채널의 전자가 tunnel layer를 통해 trap layer에 주입되어 정보를 기억하게 되는데, trap layer에 주입된 전자가 다시 채널로 빠져나가는 charge loss 현상이 큰 문제점으로 지적된다. 따라서 tunnel layer의 막질향상을 위한 다양한 열처리 방법들이 제시되고 있으며, 기존의 CTA (conventional thermal annealing) 방식은 상대적으로 높은 온도와 긴 열처리 시간을 가지고, RTA (rapid thermal annealing) 방식은 매우 높은 열처리 온도를 필요로 하기 때문에 플라스틱, 유리와 같은 다양한 기판에 적용이 어렵다. 따라서 본 연구에서는 기존의 열처리 방식보다 에너지 전달 효율이 높고, 저온공정 및 열처리 시간을 단축시킬 수 있는 마이크로웨이브 열처리(microwave irradiation, MWI)를 도입하였다. Tunneling layer, trap layer, blocking layer를 가지는 MOS capacitor 구조의 전하트랩형 플래시 메모리를 제작하여 CTA, RTA, MWI 처리를 실시한 다음, 전기적 특성을 평가하였다. 그 결과, 마이크로웨이브 열처리를 실시한 메모리 소자는 CTA 처리한 소자와 거의 동등한 정도의 우수한 전기적인 특성을 나타내는 것을 확인하였다. 따라서, MWI를 이용하면 tunnel layer의 막질을 향상시킬 뿐만 아니라, thermal budget을 크게 줄일 수 있어 차세대 투명하고 유연한 메모리 소자 제작에 큰 기여를 할 것으로 예상한다.

  • PDF

Products and pollutants of half dried sewage sludge and waste plastic co-pyrolysis in a pilot-scale continuous reactor (반 건조 하수슬러지와 폐플라스틱 혼합물의 파일롯 규모 연속식 열분해에 의한 생산물과 발생 오염물질)

  • Kim, YongHwa;Chun, Seung-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.327-337
    • /
    • 2017
  • A continuous low temperature ($510^{\circ}C{\sim}530^{\circ}C$) pyrolysis experiment in a pilot-scale of 85.3 kg/hr was carried out by the mixed feedstock of half dried digested sewage sludge and waste plastics. As a result, the amount of pyrolysis gas generated was maximum 68.3% of input dry mass and scored $40.9MJ/Nm^3$ of lower heating value (LHV), and the percentage of air inflow caused by continuous pyrolysis was 19.6%. The oil was produced 4.2% of the input dry mass, and the LHV was 32.5 MJ/kg. The sulfur and chlorine contents, which could cause corrosion of the facility, were found to be 0.2% or more respectively. The carbide generated was 27.5% of the input dry mass which shows LHV of 10.2 MJ/kg, and did not fall under designated waste from the elution test. The concentration of carbon monoxide, sulfur oxides and hydrogen cyanide of emitted flu gas from pyrolysis gas combustion was especially high, and dioxin (PCDDs/DFs) was within the legal standards as $0.034ng-TEQ/Sm^3$. Among the 47 water pollutant contents of waste water generated from dry flue gas condensation, several contents such as total nitrogen, n-H extract and cyanide showed high concentration. Therefore, the merge treatment in the sewage treatment plants after pre-treatment could be considered.

Characteristics of organic pollutants in discharged industrial waste in Korea - Focuse on metallic and plastic manufacturing processes and wastewater treatment plants - (국내 사업장 폐기물 중 유기오염물질의 배출특성 연구 - 금속과 플라스틱 제조공정 및 폐수처리시설 중심으로 -)

  • Yeon, Jin-Mo;Kang, Young-Yeul;Kim, Woo-Il;Shin, Sun-Kyoung;Jeong, Seong-Kyeong;Cho, Yoon-A;Kim, Na;Kim, Min-Sun
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.421-428
    • /
    • 2012
  • In this study, PCDD/PCDFs, PAHs and PCBs in wastes from metal, plastic and wastewater treatment facilities were analyzed. The concentrations of PCDD/PCDFs ranged from 7.37~432.20 ng-TEQ/kg in fly ash, 0.51~855.01 ng-TEQ/kg in incinerated ash and 0.37~385.81 ng-TEQ/kg in dust. Dioxin content was lower, compared to data in foreign countries. PAHs concentration was in the range of 0.0075~2.9225 mg/kg for process sludge and 0.0035~1.6716 mg/kg for wastewater sludge, which satisfied all of the two standards (Nap, Ant, B(a)F:4/0.8, Phen, B(a)A:5/1, Flt:10/2.5, B(a)P:4.5/0.9) of the Marine Environment Management Act. PAHs concentration in process sludge and wastewater sludge were slightly lower than those abroad. According to the analysis of seven types of PCBs (in comparison with the first standard, 0.15 mg/kg), concentration was found in the range of 0.0~0.65 mg/kg, while PCB-52, PCB-101, PCB-138, PCB-153 and PCB-180 isomers were detected in excessive value in some machine oil and hydraulic fluid.

Growth of Mungbean Sprouts and Commodity Temperature as Affected by Water Supplying Methods (관수방식에 따른 숙주나물의 생장과 품온 변화)

  • Kang Jin Ho;Ryu Yeong Seop;Yoon Soo Young;Jeon Seung Ho;Jeon Byong Sam
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.6
    • /
    • pp.487-490
    • /
    • 2004
  • Methods for culturing bean sprouts could be divided into two main groups of overspraying and underwatering according to water supplying. The study was done to measure the effect of water supplying method on growth of mungbean sprouts and temperatures inside their culture boxes. The morphological characters, fresh and dry weights were measured on the 6th day after culturing, but temperatures of the boxes were recorded daily by dataloggers. Lateral roots was not formed in the under-watering method (UM) while partially done in the over-spraying method (OM). OM had longer hypocotyl but UM had longer root compared to the other. Two water supplying methods, however, had nearly similar total length adding hypocotyl and root lengths, diameters of middle and upper parts of hypocotyl. OM showed more total fresh weight than UM mainly resulting from increment of hypocotyl fresh weight. The fresh weight increment in OM was caused by relatively higher temperature of culture box compared to UM.

Analysis of Stomach Contents of Sea-eel Conger myriaster Caught from lost Plastic pot (유실된 플라스틱 붕장어 통발에 어획된 붕장어의 위내용물 분석)

  • 정순범;이주희;김형석;오윤택;조삼광
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.2
    • /
    • pp.149-155
    • /
    • 2002
  • Sea-eels caught by fishing boat and trawl were analyzed to investigate feeding status and individual growth of sea-eels caught from the lost plastic sea-eel Pot which is estimated at the ghost fishing Average length of sea-eel caught from fishing boat and test fishing was 33.6cm, 48.9cm for trawl and 45.6cm for the lost plastic sea-eel pot, respectively. The length frequency distribution is the same as the fact that sea-eel goes to the offshore from the coastal waters according to the getting growth. Sea-eel rate having empty stomach were 5.0% for fishing boat, 4.2% for trawl and the empty stomach rate of sea-eel was the highest as 87.6% in the lost pot. Sea-eel rate feeding fish as prey were 98.7% for fishing boat, 78.8% for trawl and 63.3% for the lost pot, respectively and other preys were crustacean and cephalopod. Fatness index calculated using weight and length were 1.514 for trawl catches and 1.292 for the lost pot and the difference was 15% between trawl catches and the lost pot. There also was difference at the 5% significance level in the result of t-test of Covariance Analysis.

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

Compression Strength Test of FRP Reinforced Concrete Composite Pile (FRP-콘크리트 합성말뚝 시편의 압축강도실험)

  • Lee, Young-Geun;Choi, Jin-Woo;Park, Joon-Seok;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.4
    • /
    • pp.19-27
    • /
    • 2011
  • In this paper, we present a part of results to develop new type hybrid FRP-concrete composite pile (i.e., concrete filled fiber reinforced plastic circular tubes, hybrid CFFT, HCFFT). The purpose of this paper is to evaluate compressive loading capacity through compressive strength test. Before compressive strength test of HCFFT, we investigated mechanical properties of pultruded fiber reinforced plastic (PFRP) and filament winding fiber reinforced plastic (FFRP). For estimating the compressive strength of HCFFT, uni-axial compression strength tests of HCFFT compression members were conducted. The test variables are compressive strengths of concrete and thickness of FFRP. In addition, uni-axial compression strength tests of concrete filled fiber reinforced plastic circular tube (CFFT) except PFRP members were conducted. The test variable in the test is thickness of FFRP. From the test result, the compressive strength of the HCFFT in larger than compressive strength of CFFT as much as 47%. It can be observed that the uni-axial compressive strength of the HCFFT increased if the concrete strength and the thickness of exterior filament winding FRP tube increased. In addition, the finite element analysis result is compared with the experimental result. The difference between the experimental and FEM results is in the range of 0.14% to 17.95%.

Evaluation of friction of esthetic brackets according to different bracket-wire angulations (심미 브라켓의 종류와 브라켓-호선 각도에 따른 마찰 저항에 대한 연구)

  • Je, Young-Ji;Chang, Minn-Hii;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.5
    • /
    • pp.341-350
    • /
    • 2007
  • The purpose of this study was to evaluate how the friction that occurs during the sliding movement of the archwire through esthetic brackets is differently affected by bracket materials, slot designs, and tip angulations of the archwire. Methods: Eight types of brackets with 0.018 inch slots (composite: Brillant (BR); composite with metal slot: Spirit MB (SP); ceramic: Inspire (IN), Signature (SI), Cristaline V (CR); ceramic with metal slot: Clarity (CL), Luxi II (LU); and metal bracket: Integra (IT)), and placed into groups of 20 brackets in each group, were tested in artificial saliva with 0.018 inch stainless steel wire. The wire tip angulations were given as 0, 4 and 8 degrees. Results: CR group significantly showed the lowest frictional force with all wire tip angulations of 0,4, and 8 degrees. IN significantly showed the highest frictional force (p < 0.001). BR (polyoxymethylene) had significantly less frictional force than SP (polycarbonate) (p < 0.001) and showed no significant difference between metal brackets. Friction was increased as the wire tip angulations were increased, but no notches were observed on any parts of the archwire. Conclusions: According to the results of this study, esthetic brackets are superior or similar to 55 brackets from a frictional point of view.

Evaluation of the Impact Behavior of Inline Disk Wheel Made of Carbon Fiber Reinforced Composites (탄소섬유 강화 복합재로 구성된 인라인 디스크 휠의 충격거동 평가)

  • Kwon, Hye-In;Lee, Sang-Jin;Shin, Kwang-Bok
    • Composites Research
    • /
    • v.29 no.2
    • /
    • pp.73-78
    • /
    • 2016
  • In this paper, The concept of a wheel with carbon fiber composite is to replace the conventional material used for a wheel hub, such as plastic, with a disk-type hub made of carbon fabric and epoxy resin. The impact load from the ground under real conditions was considered; a low-velocity impact test was conducted to evaluate the impact performance of the carbon wheel and compare it with that of a conventional plastic wheel. This study applied a 70 J impact load as a test condition. The impact energy was controlled in the test by adjustment of height and weight of impactor. The use of a carbon disk wheel hub was confirmed to reduce weight and generate an excellent repulsive force at low energy under conditions similar to real driving conditions. The results showed that the maximum load increased proportionally depending on the impact load, but the growth of the maximum load was reduced at a 20 J impact load and tended to decrease at a 45 J impact load. The carbon wheel showed excellent properties ; the level of rebounding was 35.3% and 19.1% of the total impact energy at impact loads of 5 J and 10 J, respectively. On the other hand, the carbon disk wheel rebounded less than 5% of the total energy due to crack generation of the thin carbon hub for impact loads of more than 20 J.