A Study on Elbow Phantom Production and Usability Evaluation by Adjusting Infill Density using 3D Printing (3D 프린팅을 사용한 Infill 조절에 따른 Elbow 팬텀 제작 및 유용성 평가에 관한 연구)

  • Myung-In Kim;Seung-Ho Ji;Hyun-Seop Wi;Dae-Won Lee;Hui-Min Jang;Myeong-Seong Yun;Dong-Kyoon Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.929-937
    • /
    • 2023
  • Human equivalent phantoms manufactured using 3D printers are cheaper and can be manufactured in a short time than conventional human phantoms. However, many phantoms are manufactured with less than 100 % of Infill Density, one of the 3D printer output setting variables. Therefore, this study compared the Bone Phantom CT number, which differs from the ratio of five Infill Density produced using a 3D printer, to the CT number of the actual human body Bone. In addition, the usefulness of the manufactured phantom was evaluated by producing a 100 % elbow joint phantom with Infill Density and setting the Infill Density to 100 % through CT number comparison for each tissue on computed tomography (CT). As a result, the Bone Phantom printed with 100 % Infill Density did not show the most statistically significant difference from the CT number value of the actual human Bone, and the CT number of each tissue did not show a statistically significant difference from the CT number value of each tissue of the actual human elbow joint.

Printing Performance Evaluation of Water-dispersed Pigment Ink according to Additive Conditions of Film Substrate Surface Coating Agent (필름기재 표면 코팅제의 첨가물질 조성 조건에 따른 수분산 안료잉크의 프린팅 성능 평가)

  • Hyeok-Jin Kim;Hye-Ji Seo;Eun-Ha Kang;Min-Woo Han;Dong-Hyeon Lee;Dong-Jun Kwon;Jin-Pyo Hong
    • Textile Coloration and Finishing
    • /
    • v.35 no.4
    • /
    • pp.196-205
    • /
    • 2023
  • Water-dispersed pigment is on-going study for without air pollution in the textile and print industry. Primer treatment is essential for the substrate to improve the printing quality of eco-friendly water-dispersed pigment ink. Otherwise in the case of untreated primer, the water-dispersed pigment ink will dry onto the surface and cause defective images. This study was conducted on film substrate coating (primer) to fix eco-friendly water-dispersed pigment ink on film substrate. The drying, bleeding, and color strength of the pigment ink were examined depending on the composition and mixing ratio of the coating solution. The mixing ratio of silica gel in the coating film is increased to 0, 0.5, 1, 2 and 3 and results that DK-1-3 of silica gel ratio of 1 showed the lowest bleeding such as 52%, the letter thickness of 0.76mm and DK-1-5 of SG ratio of 3 showed the highest bleeding such as 304%, the letter thickness of 2.02mm. The mixing ratio of SPA in the coating film is increased to 2.5, 5, 7.5, SPA ratio of 7.5 has a bleeding ratio of 9% and letter thickness of 0.544mm. It showed the closest value to 0.5mm. According to the result, the optimal mixing ratio of binder, polymer coagulant, silica gel is 100:7.5:1.

Effects of Guar Gum Addition on Optimal Properties of Fish Surimi Mixture for 3D Printing (구아검 첨가가 3D 프린팅을 위한 수리미 혼합물의 특성에 미치는 영향)

  • Hyun-Sik Na;Dong-Hyeon Kim;Ha-Young Lee;Sang-Min Lee;Hyeon-Ji Yu;Go-wun Seo;ChangHyeon Ko;Seon-Woo Park;Hyung-Wook Choi;Ye-Jin Choi;Mi Jeong Jo;Dong-Woo Kim;DongHyun Ahn
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.6
    • /
    • pp.790-797
    • /
    • 2023
  • Guar gum is an edible starch extracted from Cyamopsis tetragonolobus and used as an auxiliary ingredient to enhance the viscosity and adhesiveness of food and improve its emulsification stability. Here, characteristics of fish surimi mixture with various added amounts (0, 0.23, 0.45, 0.67, and 0.89 wt%) of guar gum were analyzed. In unheated surimi with guar gum, the pH decreased as the content increased. In the color values analysis, only the b* (yellowness) increased depending on the amount of added guar gum. The firmness increased with increasing guar gum content, and no significant difference in adhesiveness was observed. In heated surimi, a* (redness) and b* decreased in a content-dependent manner, and L* (lightness) was higher than that of unheated surimi. Regarding physical properties, the highest values of hardness, gumminess, and chewiness were observed in the heated surimi with 0.67 wt% of guar gum. However, no significant change was observed in springiness and cohesiveness. Results of sensory evaluation indicated that with higher guar gum content, only the hardness increased slightly, and significant differences were absent in the remaining parameters. Thus, surimi with 0.67 wt% of guar gum is considered to be optimal for 3D printing.

A Study on the Usefulness of an Ankle Joint Examination Assistive Device using a 3D Printing (3D 프린터를 이용한 발목관절 검사 보조기구의 유용성연구)

  • Dong-Hee Hong;Eun-hye Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1099-1108
    • /
    • 2023
  • The mortise view radiography procedure is an ankle joint examination and observes the presence of trauma, sprain, or dislocation suspected in the ankle joint. The auxiliary equipment used during the mortise view radiography procedure can generate artifacts in the radiograph images and is not diverse enough to be custom-made for each patient; not cost-efficient. The purpose of this study is to create a custom assistive device to support mortise view radiography procedure. This study utilized 3D printing technology to create the mortise view radiography procedure assistive device (ShinHan Device; SHD). The lengths of the tibiotalar joint (TTJ), talar calcaneal joint (TCJ), and medial joint (MJ) were measured and evaluated by five researchers using both SHD and the prototype Hologic tool. The mean ranges were found to be 39.42-39.47 mm for TTJ, 31.41-31.57 mm for TCJ, and 21.21-21.23 mm for MJ while using SHD device. On the other hand, the measurements showed mean ranges of 39.73-39.79 mm for TTJ, 31.46-31.50 mm for TCJ, and 21.31-21.35 mm for MJ while using the Hologic tool. Based on this study results, the error ranges at all positions decreased by 24% for TTJ, 17% for TCJ, and 36% for MJ when using SHD device compared to the Hologic tool. Moreover, when SHD was used, it allowed for a highly reproducible examination posture (ICC = 0.99), and it enabled the acquisition of radiograph images without artifacts, which were present in the Hologic tool.

Analysis of Buildability and Strength Characteristics of Cement-based Composite Materials by Manufacturing Method of Laminated Specimens (적층시험체 제작 방식에 따른 시멘트계 복합재료의 적층성능 및 강도 특성 분석)

  • Eun-A Seo;Ho-Jae Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.9-15
    • /
    • 2023
  • In this study, the lamination performance and strength characteristics of cement-based composite materials according to the laminated specimens manufacturing method were analyzed. As a result of evaluating the buildability according to the layer height, the highest dimensional stability was shown when the layer height was 10 mm in all parts. The mold casting specimen and the printing-Z specimen showed the same compressive strength performance at the age of 28 days. On the other hand, the compressive strength at 28 day of printing-X specimen was the lowest at 71.72 MPa, and 8% lower than that of the mold casting specimen and the printing-Z specimen. The split tensile strength of the laminated specimen may show similar performance to that of the mold casting specimen, but the strength performance may decrease by more than 10% depending on the direction of the layer and the number of layers in the specimen. As a result of the interface analysis of the laminated specimen through X-ray CT analysis, it was confirmed that pores of a certain size were distributed along the interface of the layer.

Effects of Naked Barley Starch on Properties of Fish Surimi Mixture for 3D Printing (쌀보리 전분의 첨가가 수리미 혼합물의 3D 프린팅 적합성에 미치는 영향)

  • Ha-Young Lee;Hyeon-Ji Yu;Sang-Min Lee;Hyun-Sik Na;Dong-Hyeon Kim;Go-Wun Seo;Chang-Hyeon Ko;Seon-Woo Park;Hyung-Wook Choi;Ye-Jin Choi;Mi Jeong Jo;Dong-Woo Kim;Dong-Hyun Ahn
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.57 no.2
    • /
    • pp.109-115
    • /
    • 2024
  • This study investigated the effects of various naked barley starch contents (0, 0.67, 1.34, 2.0, and 2.67 wt%) in surimi mixtures for 3D printing. Adding starch to surimi altered its texture, potentially reducing production costs. Unheated surimi became less firm with higher starch content. After heating, there was an increase in hardness, adhesiveness, springiness, cohesiveness, gumminess, chewiness, and resilience, peaking at 1.34 wt% starch. Compared to the negative control, starch-added heated surimi had a tougher texture. The color values (L*, a*, and b*) decreased after heating, with no significant change in shearing force with increasing starch content. Sensory evaluation indicated improved smell, texture, hardness, elasticity, and preference over the negative control. Higher starch content increased hardness for 3D printing suitability with no significant difference above 1.34 wt% starch indicating this is the most appropriate content. Naked barley starch enhanced surimi strength without affecting smell and preference, suggesting it as a potential surimi additive.

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.

Digital immediate implantation and aesthetic immediate loading on maxillary incisor displaced due to root fracture: a case report (치근파절로 변위된 상악 중절치의 디지털을 이용한 즉시 임플란트 식립 및 심미 수복 증례)

  • Jieun Song;Songyi Park;Chan Park;Kwidug Yun;Hyun-Pil Lim;Sangwon Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.267-275
    • /
    • 2023
  • To obtain better esthetic results when immediately placing a dental implant, the soft tissue surrounding the implant must be conditioned during healing of the extraction socket. To this end, the emergence profile can be customized through immediate restoration of the provisional prosthesis, and good clinical results can be obtained at the time of definitive restoration in the future, resulting in high patient satisfaction. In this case, horizontal root fracture occurred after trauma to both maxillary central incisors. Immediate implant placement and loading was planned considering aesthetics and alveolar bone condition. By taking an impression using a digital intraoral scanner, a digital diagnostic wax-up was performed to make a more aesthetic prosthesis without applying external force to the traumatized teeth. Based on this, the ideal placement location was determined and immediate implant placement was performed using a 3D printed surgical guide. The provisional prosthesis was restored 5 days after placement, and the definitive zirconia crown was restored through soft tissue conditioning and customization using the shape of the provisional prosthesis for 3 months.

Application and Performance Evaluation of Photodiode-Based Planck Thermometry (PDPT) in Laser-Based Packaging Processes (레이저 기반 패키징 공정에서 광 다이오드 기반 플랑크 온도 측정법(PDPT)의 적용 및 성능 평가)

  • Chanwoong Wi;Junwon Lee;Jaehyung Woo;Hakyung Jeong;Jihoon Jeong;Seunghwoi Han
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.2
    • /
    • pp.63-68
    • /
    • 2024
  • With the increasing use of transparent displays and flexible devices, polymer substrates offering excellent flexibility and strength are in demand. Since polymers are sensitive to heat, precise temperature control during the process is necessary. The study proposes a temperature measurement system for the laser processing area within the polymer base, aiming to address the drawbacks of using these polymer bases in laser-based selective processing technology. It presents the possibility of optimizing the process conditions of the polymer substrate through local temperature change measurements in the laser processing area. We developed and implemented the PDPT (Photodiode-based Planck Thermometry) to measure temperature in the laser-processing area. PDPT is a non-destructive, contact-free system capable of real-time measurement of local temperature increases. We monitored the temperature fluctuations during the laser processing of the polymer substrate. The study shows that the proposed laser-based temperature measurement technology can measure real-time temperature during laser processing, facilitating optimal production conditions. Furthermore, we anticipate the application of this technology in various laser-based processes, including essential micro-laser processing and 3D printing.

A phantom production by using 3-dimentional printer and In-vivo dosimetry for a prostate cancer patient (3D 프린팅 기법을 통한 전립샘암 환자의 내부장기 팬텀 제작 및 생체내선량측정(In-vivo dosimetry)에 대한 고찰)

  • Seo, Jung Nam;Na, Jong Eok;Bae, Sun Myung;Jung, Dong Min;Yoon, In Ha;Bae, Jae Bum;Kwack, Jung Won;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. Materials and Methods : The phantom is produced to equally describe prostate and rectum based on a 3D volume contour of an actual prostate cancer patient who is treated in Asan Medical Center by using a 3D printer (3D EDISON+, Lokit, Korea). CT(Computed tomography) images of phantom are aquired by computed tomography (Lightspeed CT, GE, USA). By using treatment planning system (Eclipse version 10.0, Varian, USA), treatment planning is established after volume of a prostate cancer patient is compared with volume of the phantom. MOSFET(Metal OXIDE Silicon Field Effect Transistor) is estimated to identify precision and is located in 4 measuring points (bladder, prostate, rectal anterior wall and rectal posterior wall) to analyzed treatment planning and measured value. Results : Prostate volume and rectum volume of prostate cancer patient represent 30.61 cc and 51.19 cc respectively. In case of a phantom, prostate volume and rectum volume represent 31.12 cc and 53.52 cc respectively. A variation of volume between a prostate cancer patient and a phantom is less than 3%. Precision of MOSFET represents less than 3%. It indicates linearity and correlation coefficient indicates from 0.99 ~ 1.00 depending on dose variation. Each accuracy of bladder, prostate, rectal anterior wall and rectal posterior wall represent 1.4%, 2.6%, 3.7% and 1.5% respectively. In- vivo dosimetry represents entirely less than 5% considering precision of MOSFET. Conclusion : By using a 3D printer, possibility of phantom production based on prostate is verified precision within 3%. effectiveness of In-vivo dosimetry is confirmed from a phantom which is produced by a 3D printer. In-vivo dosimetry is evaluated entirely less than 5% considering precision of MOSFET. Therefore, This study is confirmed the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. It is necessary to additional phantom production by a 3D printer and In-vivo dosimetry for other organs of patient.

  • PDF