• 제목/요약/키워드: 프리텐션

검색결과 111건 처리시간 0.02초

높이가 큰 프리텐션 콘크리트 보에서의 비선형 스트럿-타이 모델 방법 (Nonlinear Strut-Tie Model Approach in Pre-tensioned Concrete Deep Beams)

  • 윤영묵;이원석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.847-852
    • /
    • 2000
  • This paper presents an evaluation of the behavior and strength of two pre-tensioned concrete deep beams tested to failure with using the nonlinear strut-tie model approach. In the approach, the effective prestressing forces represented be equivalent external loads are gradually introduced along its transfer length in the nearest strut-tie model joints, the friction at the interface of main diagonal shear cracks is modeled by diagonal struts along the direction of the cracks in strut tie-model, and additional positioning of concrete ties a the place of steel ties is incorporated. Through the analysis of pre-tensioned concrete deep beams, the nonlinear strut-tie model approach proved to present effective solutions for prediction the essential aspects of the behavior and strength of pre-tensioned concrete deep beams.

  • PDF

프리텐션공법의 프리스트레스트 콘크리트 부재의 정착길이 산정에 관한 실험 및 이론연구 (Derivation of Development Length in Pretensioned Prestressed Concrete Members)

  • 오병환;김의성;최영철
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.3-11
    • /
    • 2000
  • In pretensioned concrete structures, bond between prestressing steel and concrete is an essential component to ensure the integrity of a pretensioned member. The anchorage and development of the prestressing force depend exclusively on bond. The purpose of this study is to investigate the characteristics of bond and development length between pretensioned steel and concrete. To resolve the controversy over the adequacy of the current code provision on development length of prestressing strands, a comprehensive test program has been scheduled and twenty four rectangular prestressed concrete beams have been tested to determine development length. Major test variables include diameter of strands (12.7mm, 15.2mm) and concrete covers (3cm, 4cm, 5cm). The test results indicate that the development length based on the bond stress-slip relation. The proposed model can evaluate realistically the development length of pretensioned prestressed concrete members and can be the good basis for the future basis of code equations on development length of PSC members.

유한요소해석을 통한 포스트텐션 정착구 형상 변수의 정착부 극한강도 영향 분석 (Ultimate Strength of Anchorage Zone according to Geometric Parameters of Post-Tensioning Anchorage using a Finite Element Method)

  • 권양수;김진국;곽효경
    • 한국전산구조공학회논문집
    • /
    • 제28권3호
    • /
    • pp.317-324
    • /
    • 2015
  • 프리스트레스 콘크리트 정착부의 설계를 위해 AASHTO 및 PTI에서 관련 설계식을 제안하고 있다. 그러나 이러한 설계식은 구조물의 긴장력이 단순 지압판을 통해 구조 전반으로 전달된다는 가정으로 유도된 것으로 실제 구조물에 적용되는 상용 정착구의 형태와는 차이가 있다. 이 논문에서는 하중전달 시험에 의한 실험적 방법과 3차원 고체요소를 사용한 비선형 유한요소해석 프로그램을 이용한 해석적 방법을 통해 정착구의 형상 변수에 따른 정착부의 거동특성 변화에 대한 연구를 수행하였다. 하중전달시험 결과에서 얻어진 하중변위 곡선 및 극한하중 값을 해석을 통해 얻은 결과와 비교하여 유한요소모델의 적합성을 확인하였다. 또한 정착구의 리브의 설치위치, 리브의 개수, 리브의 설치길이를 주요 변수로 설정하여 형상변수에 따른 매개변수 연구를 수행하였다.

FBG 광섬유센서가 내장된 7연 강연선을 이용한 포스트텐션 UHPC 교량의 긴장력 장기모니터링 (Long Term Monitoring of Prestressing Tension Force in Post-Tension UHPC Bridge using Fiber Optical FBG Sensor)

  • 김현우;김재민;최송이;박성용;이환우
    • 한국전산구조공학회논문집
    • /
    • 제28권6호
    • /
    • pp.699-706
    • /
    • 2015
  • 이 연구에서는 FBG센서가 내장된 강연선을 포스트텐션 UHPC 교량(길이 11.0m, 폭 5.0m, 높이 0.6m)에 적용하고 약 1년간의 긴장력 장기모니터링 결과를 정리하였다. 그리고 초기 도입 긴장력과 차량재하시험을 통하여 콘크리트 내부 강연선의 긴장력 변화를 계측하고 계측결과에 대한 분석을 수행하였다. 연구결과, 이 연구에서 제안하는 콘크리트 내부 긴장력 측정방법이 공영 중인 교량에서 외력으로 인한 콘크리트 내부의 작은 프리스트레스 변화를 효과적으로 측정할 수 있음을 알 수 있었다. 아울러 장기 계측결과를 이용하여 응력변화에 의한 유효변형률을 정확하게 얻기 위해서는 온도보정에 사용되는 열팽창계수의 선택이 매우 중요함을 알 수 있었다.

부착된 프리스트레스 넓은 보-기둥 외부접합부의 유한요소해석 (FE Analysis of Exterior Wide Beam-Column Connections with Bonded Tendon Stress)

  • 이문성;최윤철;임재형;문정호;최창식
    • 한국전산구조공학회논문집
    • /
    • 제21권4호
    • /
    • pp.307-315
    • /
    • 2008
  • PPS(Post-tensioned Precast concrete System)공법은 U자형 PC로 제작된 넓은 보와 PC또는 현장 타설 콘크리트로 제작한 기둥으로 구성되며, PC보와 기둥의 일체성 확보를 위하여 프리스트레스를 도입하였다. 본 연구에서는 포스트텐션을 도입한 넓은 보-기둥 접합부의 구조적 특성을 규명하고, 다양한 변수해석이 가능하기 위한 자료를 제공하고자 유한요소해석 프로그램인 ANSYS을 사용하여 비선형 해석을 수행하였다 콘크리트에 대한 해석요소는 8개의 절점을 가지며 각 절점이 3개의 자유도(X, Y, Z축에 대한 병진 변위)를 갖는 Solid 65요소를 사용하였다. Solid 65요소에서 전단전달계수(Shear-Transfer factor)는 실험값에 근사적으로 해석값을 맞추기 위한 영향 계수값으로 균열이 발생하는 위치에 대한 전단강도의 감소를 반영한다. 그 결과, 본 실험체에 대한 해석에서는 열려진 전단전달계수 0.125와 닫혀진 전달계수 0.85에 기초하여 해석한 결과 닫혀진 전단전달계수는 0.85에서 열려진 전단전달계수에서는 0.2일때 가장 실험값에 근사한 해석치를 보였다.

2400MPa 긴장재가 적용된 포스트텐션 프리캐스트 콘크리트 보-기둥 접합부의 반복가력실험 (Reversed Cyclic Loading Test of Post-Tensioned Precast Concrete Beam-Column Connections with 2400MPa Prestressing Strands)

  • 황진하;최승호;이득행;김강수;우운택
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.45-52
    • /
    • 2017
  • The precast concrete (PC) method has many advantages in fast construction, quality control, etc. In domestic construction market, however, its application has been quite limited because of the concerns about structural integrity and seismic performances due to the discrete connections between precast concrete members. By applying the post-tensioning method, the precast beam-column connection can be well tightened, allowing improved structural integrity, and proper seismic performances can be also achieved. In this study, reversed cyclic tests have been conducted on the beam-column connection specimens, where the test variables included the compressive strength of grouting mortar and the tensile strengths of prestressing strands, based on which their seismic performances have been examined in detail. The post-tensioned PC beam-column connections showed good seismic performances comparable to that of the monolithic reinforced concrete connection specimen. When 2400 MPa prestressing strands are applied to the beam-column connection, it is preferable to adjust the prestress level similar to that applied for the 1860 MPa prestressing strands to avoid premature local crushing failures at the beam-column connections.

인장타이를 이용한 비닐하우스의 보강효과에 관한 실험적 연구 (Experimental Study on Strengthening Effect of Plastic Greenhouse using Tension-tie)

  • 장유진;이수헌;채승훈;신경재
    • 한국강구조학회 논문집
    • /
    • 제22권2호
    • /
    • pp.151-160
    • /
    • 2010
  • 최근 기상이변으로 인한 겨울철 폭설로 농가 시설물 중의 하나인 비닐하우스의 붕괴사고가 빈번히 발생하여 농가의 피해가 증가되고 있다. 하지만 이에 대한 정부의 대책이 미약하여 매년 붕괴사고가 일어난다. 프레임 붕괴의 주된 이유는 폭설시 저항할 수 있는 휨내력이 부족하기 때문이다. 본 연구에서는 현재 이용되는 비닐하우스에 인장타이로 보강한 실험연구를 수행하였다. 비닐하우스의 스팬은 6.5m이고, 단면은 두 가지 종류(${\phi}25.4{\times}1.5$, ${\phi}31.8{\times}1.5$)를 사용하였다. 비닐하우스의 곡선 보와 직선 기둥 연결부에 임시적인 인장타이로 스틸와이어와 로프를 이용하여 보강하였다. 프리텐션을 인장타이에 적용시켰고, 적설하중을 등가의 수직하중으로 파괴할 때까지 적용하였다. 무보강과 로프 보강을 비교한 결과 로프 보강의 붕괴하중이 10∼45% 증가하였고 무보강과 스틸와이어 보강을 비교한 결과 스틸와이어 보강의 붕괴하중이 58~73% 증가하였다. 강도와 관련해서는 비교적으로 스틸와이어가 효과적이나, 연결부 및 프리텐션 적용이 로프보다 복잡하고 어려우므로 로프가 더 효율적인 것으로 판단된다.

RC 부재의 휨 보강을 위한 외부 비부착형 탄소섬유판 포스트텐션 시스템 (Post-tensioning System with Externally Unbonded CFRP Strips for Strengthening RC Members)

  • 유영찬;최기선;김긍환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.147-154
    • /
    • 2008
  • 본 연구에서는 외부 비부착형 프리스트레스트 탄소섬유판으로 보강된 RC보의 휨거동을 분석하기 위한 실험연구를 수행하였다. 실험체는 프리스트레스 양 및 정착장치의 형상을 변수로 총 10개로 제작되었다. 또한 프리스트레스의 도입에 따른 구조성능 비교를 위하여 기준실험체와 단순부착 실험체를 함께 제작하였다. 실험결과, 단순 부착 탄소섬유판으로 보강된 부재는 조기 박리에 의해 탄소섬유판 인장강도의 50% 이하에서 최종파괴되었다. 그러나, 프리스트레스를 도입하여 보강한 실험체는 모두 탄소섬유판의 파단하중까지 도달하였다. 또한 스터드형 정착장치를 적용한 실험체들의 보강성능은 매립형 정착장치를 적용한 실험체와 동등한 보강성능을 나타내었다.

원형 정착판을 사용한 포스트텐션 특수정착구의 설계에 관한 연구 (A Study on the Design of Special Circular Plate Anchorage for Post-tension)

  • 최규형;노병철;임정훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권6호
    • /
    • pp.73-83
    • /
    • 2016
  • 포스트텐션 공법을 적용한 콘크리트 부재의 정착구역에서 정착판 근처의 지압응력은 일반적으로 높은 프리스트레스 하중에 의해 발생한다. 따라서 단면의 효율적인 활용과 콘크리트 부재의 파괴로 이어질 수 있는 균열제어를 위해 적절한 정착판의 크기가 제시되어야 한다. 본 연구에서는 도로교설계기준 및 PTI 등에 의해 사각형 정착판과 원형 정착판의 유효면적에 대한 관계식을 제안하였다. 또한 정착판의 형상에 따라 형상계수를 제안하였으며, 유한요소해석을 통해 적절성을 분석하였다.

고속축중계가 설치된 포스트텐션 콘크리트 포장의 실험적 거동 분석 (Experimental Analysis of Weigh-in-Motion Sensor Installed Post-Tensioned Concrete Pavement Behavior)

  • 박희범;배종오;김성민;안주옥
    • 한국도로학회논문집
    • /
    • 제12권3호
    • /
    • pp.139-146
    • /
    • 2010
  • 본 연구는 포스트텐션 콘크리트 포장(PTCP: Post-Tensioned Concrete Pavement)에 고속축중계(WIM: Weigh-in-Motion)를 설치한 포장 시스템의 거동을 분석하기 위하여 수행되었다. PTCP는 일차로 폭으로 기존의 아스팔트 포장을 절삭하여 제거한 후에 시공되었다. PTCP는 슬래브의 연장이 길기 때문에 긴장을 통해 프리스트레스를 적절히 작용시키기 위해서는 슬래브와 하부층과의 마찰이 적어야 하며 이러한 영향을 시험시공을 통해 우선적으로 분석하였으며, 환경하중에 따른 슬래브의 종방향 거동도 분석하였다. 시험시공을 통해 얻은 결과를 바탕으로 공용중인 도로에 WIM 센서를 설치한 PTCP를 시공하였으며 이러한 포장체가 환경하중을 받을 때의 컬링 거동을 측정하여 특성을 분석하였다. 연구결과 PTCP 슬래브 상부의 일부를 절삭하여 WIM 센서를 설치하더라도 PTCP의 거동은 이에 영향을 받지 않는 것을 알 수 있었으며, WIM 센서의 정밀 측정에 부합되는 PTCP 시스템을 시공할 수 있는 기반을 마련하였다.