• Title/Summary/Keyword: 프리스트레싱

Search Result 122, Processing Time 0.024 seconds

Evaluation of Prestress Loss in Prestressing Reinforcing Units using Steel Bar and Pipe (강봉 및 강관을 이용한 프리스트레싱 유닛의 긴장 응력 손실 평가)

  • Sim, Jae-Il;Mun, Ju-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.75-82
    • /
    • 2021
  • The objective of this study is to examine the loss of prestressing stress in the developed prestressing reinforcing units using steel bar and pipe (SP). The main parameters were the reinforcing bar type, the magnitude of prestressed force, and prestressing method. The test results showed that the loss of prestressing stress for SP was highest in the initial prestressing step, which was higher for the compression introduction typed specimens than tension introduction typed specimens. The loss of prestressing stress of SP made with P800 was 1.6% for the compression introduction typed specimen with 0.8fy, which was lowest than the other specimens. Meanwhile, the relaxation of SP with the respect to the time ranged between 0.4 and 1.9%, irrespective of SP material type, the magnitude of prestressed force, and prestressing method. These values were less than 2.5%, which is the maximum value for the relaxation of prestressed reinforcing steel bars in design codes. Consequently, considering the loss of stress developed in the initial prestressing step, the developed SP material type, prestressing introduction method, and magnitude are recommended to be P800, compression introduction type, and 0.8fy.

Behavior of PSC Girder with Partially Corrugated Web (부분 파형강판을 복부로 사용한 PSC거더의 거동)

  • Choi, Kyu-Tae;Ahn, Jin-Hee;Park, Hyun-Min;Kim, Sang-Hyo;Jung, Sang-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.47-48
    • /
    • 2009
  • This study suggested partially corrugated web PSC girder considering bucking characteristics to get advantages of serviceability improvement and prestressing efficiency. In addition, Behavior characteristics of partially corrugated web PSC girder was examined by static loading test.

  • PDF

Case study on the external prestressing method strengthened carbon fiber reinforced plates. (탄소섬유 보강판 전용 정착장치를 이용한 외부 프리스트레싱 보강공법 사례연구)

  • 정원용;임공묵
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1003-1006
    • /
    • 2003
  • In recent years, FRP plates have been studied for flexural reinforcement of RC structures due to easy installation and good Quality control. This study presents experimental field test results for the effectiveness of flexural reinforcement of the RC slab using external prestressing with thin CFRP strips made by the pultrusion process. It was demonstrated that flexural strength was considerably increased with relatively easy installation when compared to the other methods used for the composite reinforcement.

  • PDF

Strengthening of Reinforced Concrete Structures using Externally Prestressed CFRP plates (외부 프리스트레스트 탄소섬유판에 의한 구조물 보강공법)

  • 박선규;유영찬
    • Computational Structural Engineering
    • /
    • v.17 no.1
    • /
    • pp.39-42
    • /
    • 2004
  • 콘크리트 구조물에 대한 보강공법은 1950년도에 개발된 강판보강공법을 위시로 하여 강연선에 의한 외부프리스트레싱 공법으로 발전하고 있으며, 약 10년전부터는 신소재인 FRP(Fiber Reinforced Polymer)에 의한 보강공법이 본격적으로 개발되어 실용화되고 있다. 강판보강공법은 에폭시 등의 접착제를 이용하여 콘크리트 인장측에 강판을 접착함으로써 강도 및 강성을 증가시키는 공법으로 강판을 보강재로 이용함으로써 공법에 대한 인지도가 높은 장점이 있는 반면, 재료의 가공 및 취급이 어려우며 중량이 커 자중이 증가되는 단점이 있다. 또한, 강재의 부식위험이 상존하고 있어 이에 대한 세심한 배려 및 주기적인 유지관리를 필요로 한다.(중략)

A Comparative Study on the Equivalent Load Method and the Initial Stress Method for Modeling of the Prestressing Tendon (프리스트레싱 텐던의 모델링을 위한 등가하중법과 초기응력법의 비교연구)

  • Jeon, Se-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.459-462
    • /
    • 2005
  • In finite element analysis of the PSC structures, the prestressing effect can be introduced by two ways, i.e, equivalent loads or initial stress. This study investigates the reason why the two schemes that adopt the different approaches produce the similar results. The discussion is applicable to the general finite elements that correspond to the concrete and tendons. Some of the detailed derivations of each scheme are presented. Numerical examples show the identical results for the two methods.

  • PDF

An Experimental Study on Retrofit Effect of Shear Wall with Opening Using Steel Bar or Steel Plate (강봉 및 강판을 이용한 개구부를 갖는 전단벽의 보강효과에 관한 실험 연구)

  • Choi, Youn-Cheul;Bae, Baek-Il;Choi, Chang-Sik;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.2
    • /
    • pp.129-138
    • /
    • 2009
  • Recently, for more demands of the economical benefits and environmental conservation, many engineers prefer to choose remodeling. Artificial openings are often unavoidable to make house wider, which will degrade wall strength and stiffness by losing effective wall section that may cause the weakening of system capacity. In these cases the damaged shear walls need to be retrofitted by additional materials or members. In this research, four specimens were tested to investigate the capacity of the damaged wall and the retrofitted wall. The artificially damaged wall was prestressed by tendons to improve the shear capacity of the wall, and the other walls were retrofitted by adding steel plate at the surface for the same purpose. Consequently, these retrofitted walls had improved capacity and stiffness in both shear and flexure. Especially, the wall with steel plate showed ductile behavior after ultimate load and the prestressed wall had greater stiffness than the unstrengthened prototype wall.

An Experimental Study on Uniaxial Compressive Behavior of RC Circular Columns Laterally Confined with Prestressing Aramid Fiber Strap (아라미드 스트랩으로 프리스트레싱 횡구속된 RC 원형기둥의 일축압축거동에 관한 실험적 연구)

  • Han, Sang-Hoon;Hong, Ki-Nam;Lee, Jae-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.2
    • /
    • pp.159-168
    • /
    • 2009
  • In this study, strength, stiffness and confinement effect with stress-strain and stress-volumetric strain curves for improved uniaxial compressive behavior of RC circular columns laterally confined with prestressing aramid fiber strap were experimentally investigated. The test variables were the specimens with or without axial reinforcing bar and the number and spacing of strap, prestressing level, the types of reinforcing fiber (CFS, GFS). As a result, the failure type of the columns was very stable and strength increase rate was about 73% comparison with the general RC columns. Moreover, the strain increase rate is very small and the axial displacement confinement effect was very effective compared with existry methods (CFS, GFS), the initial and final lateral confinement effect was excellent.

Effect of the Prestressing Tendon Arrangement in the Wall of Circular Storage Tank (원형탱크 구조물 벽체의 텐던 배치에 대한 고찰)

  • 전세진;정철헌;진병무
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.759-765
    • /
    • 2002
  • Prestressing tendons in the wall of circular storage tank are investigated from the viewpoint of equivalent load method. Special attention is paid to the effectiveness of eccentricities of the hoop and vertical tendons. Local effect at the bent Point of vertical tendon in the wall with varying thickness is examined. Some aspects which are frequently overlooked or misinterpreted in the conventional analyses of vertical tendons are discussed. Numerical examples are presented to emphasize the significance of accurate analysis of the vortical tendon in practice. It is expected that the equivalent load method can be effectively used to simplify the analysis of tendons in the circular wall and to minimize the errors.

Experimental Verification on the Structural Safety of Cantilever Beam Connected with Post-installed Adhesive Anchor Bolts (부착식 후설치 앵커로 연결된 내민보의 구조 안전성에 대한 실험적 평가)

  • Oh, Hong-Seob;Park, Sung-Rak
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.529-536
    • /
    • 2011
  • Recently, there has been a growing interest in expanded sidewalks for existing bridges. The cantilever beam system applied to expanded sidewalks for existing bridges are connected with the concrete structure by adhesive anchor bolts. However, the extended sidewalks are currently constructed without standardized regulations, which lead to excessive design of the beam spacing and installation and the construction difficulties due to the excessive over-weight. Moreover, there is only limited analysis and experiment data on the post-installed adhesive anchor bolts, so the excessive number of bolts is used for the connection. This paper deals with a method to increase the effectiveness of beam sections and anchor bolts geometry for expanded sidewalk of existing bridge. The study results showed that the failure of cantilever beam connected by adhesive anchor bolts was dominated by bond failure of interface between concrete and bolt. Also, the results indicated the possibilities of improving serviceability as well as safety of the sidewalks by changing of beam section and prestressing the bolts.

An Experimental Study on Sidewalk on the Bridge Bracket Section to Optimize (교량 보도부 브라켓 단면의 최적화를 위한 실험적 연구)

  • Park, Sungrak;Oh, Hongseob;Nam, Kiwook
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.158-158
    • /
    • 2011
  • 통상 교량구조물은 차도부와 보도부 및 그 부속시설로서 난간 및 연석부 등으로 구성되는데, 자동차 전용도로의 경우 보도부가 설치되지 않게 되고, 국내의 국도 및 지방도상의 많은 교량이 차도부와 보도부의 별도의 구분이 없이 보행자가 연석부 위로 통행하거나 여의치 않을 경우 난간에 기대어 통행하는 경우가 일반적이어서 안전사고의 위험에 직접 노출되는 경우가 많다. 이에 국토해양부에서는 최근 "도로의 구조 및 시설기준에 관한 규칙"을 개정하여 국내의 보행자 관련 교통사고로 인한 사망자가 전체 교통사고 사망자의 약 절반을 차지하는 실정을 고려하여 보행자의 안전한 통행로 확보를 통해 보행공간의 근본적인 개선이 불가피한 실정임을 시사 하였다. 이에 국내에서는 교량 보도부의 확장에 대한 관심이 높은 실정이며, 현재 보도부 확장에 대한 시공이 활발하게 이뤄지고 있다. 그러나 기존 교량에 보도부를 신설 혹은 확장함에 있어서 보도부 부재의 설치 간격 및 필요한 앵커볼트의 수량 및 부재의 성능 평가에 대한 기준이 명확하게 이뤄지지 않은 상태에서 설치되어져 왔었다. 기존에 시공되던 H-형강의 브라켓 단면의 경우 브라켓 단면의 중량이 커서 안정성 및 시공성이 떨어지며 과다한 앵커볼트의 체결 및 브라켓 단면의 과다설계로 인한 공사기간 및 비용의 증대를 가져오는 문제점이 있었다. 이에 본 연구에서는 교량 보도부의 확장 및 신설에 있어서 보도부 부재의 설치간격의 적정성 및 브라켓의 최적화를 위한 브라켓의 성능평가 시험을 수행하였다. 브라켓의 성능평가 시험은 1차 2차 3차 시험으로 나누어 진행되었으며, 1차시험은 H-형강의 브라켓단면을 원형강관으로서의 대체 가능성을 확인하였고, 2차 시험에서는 원형강관의 브라켓 단면의 앵커볼트수량의 최적화에 대한 시험을 수행하였으며, 3차 시험은 최적화된 브라켓 단면에 프리스트레싱의 도입으로 반력 및 인발력의 감소효과를 확인하는 연구를 수행하였다. 본 연구의 수행결과 기존의 설계 및 시공방법이 과다 설계가 이뤄졌음을 판단하였고, 브라켓 단면의 최적화를 통하여 기존 시공방법에 비해 시공성, 안전성, 경제성을 높일수 있을 것으로 판단된다.

  • PDF