Effect of the Prestressing Tendon Arrangement in the Wall of Circular Storage Tank  

전세진 (대우건설기술연구소)
정철헌 (대우건설기술연구)
진병무 (대우건설기술연구소)
Publication Information
Journal of the Korea Concrete Institute / v.14, no.5, 2002 , pp. 759-765 More about this Journal
Abstract
Prestressing tendons in the wall of circular storage tank are investigated from the viewpoint of equivalent load method. Special attention is paid to the effectiveness of eccentricities of the hoop and vertical tendons. Local effect at the bent Point of vertical tendon in the wall with varying thickness is examined. Some aspects which are frequently overlooked or misinterpreted in the conventional analyses of vertical tendons are discussed. Numerical examples are presented to emphasize the significance of accurate analysis of the vortical tendon in practice. It is expected that the equivalent load method can be effectively used to simplify the analysis of tendons in the circular wall and to minimize the errors.
Keywords
prestressed concrete; circular storage tank; equivalent load method; hoop(circumferential) tendon; vertical tendon;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Lin, T. Y. and Burns, Ned H., "Design of Prestressed Concrete Structures," 3rd edition, John Wiley & Sons, 1981.
2 Brondum-Nielsen, T., "Prestressed Tanks," ACI Structural Journal, Vol. 82, No. 4, July-Aug. 1985, pp.500 - 509.
3 Ghali, A. and Elliott, E., "Prestressing of Circular Tanks," ACI Structural Journal, Vol. 88, No. 6, Nov.-Dec. 1991, pp.721-729.
4 PCI Committee on Precast, Prestressed Concrete Storage Tanks, "Recommended Practice for Precast Prestressed Concrete Circular Storage Tanks," PCI Journal, V. 32, No. 4, July-Aug. 1987, pp.80 - 125.
5 Nawy, E. G., "Prestressed Concrete: A Fund-amental Approach," Prentice Hall, 1989.
6 "ANSYS 5.6 - User's Manual," ANSYS, Inc., 1999.
7 Ghali, A., "Circular Storage Tanks and Silos," 2nd edition. E & FN Spon. 2000.
8 ACI 373R-97, "Design and Construction of Circular Prestressed Concrete Structures with Circumferential Tendons, " American Concrete Institute, 1997.
9 ACI 372R-97, "Design and Construction of Circular Wire and Strand-Wrapped Prestressed Concrete Structures," American Concrete Institute, 1997.
10 Brondum-Nielsen, T., "Linear Transformation of Center of Gravity of Steel Line in Statically Indeterminate Prestressed Concrete Structures," ACI Structural Journal, Vol. 89, No. 2, March-April 1992, pp.139-140.
11 Priestley, M. J. N., "Analysis and Design of Circular Prestressed Concrete Storage Tanks," PCI Journal, Vol. 30, No. 4, July-Aug. 1985, pp.64-85.
12 BS 7777, "Flat-bottomed, Vertical, Cylindrical Storage Tanks for Low Temperature Service:Part 3," British Standards Institution, 1993.
13 ACI 334.1R-92, "Concrete Shell Structures Practice and Commentary," Armican Concrete Institute, 1997.
14 (주)대우건설, 대림산업주식회사, "통영 생산기지 저장 탱크 및 본설비공사 기술제의서(Technical Part)," 한국가스공사, 1999.
15 오병환, 전세진, "등가하중법 관점에서 분석한 프리스트레싱 텐던의 직선이동," 콘크리트학회 논문집, 제14권 6호, 2002, 12. (게재예정).   과학기술학회마을   DOI   ScienceOn