• Title/Summary/Keyword: 프레온

Search Result 64, Processing Time 0.025 seconds

Korean Fifteen-Year-Olds' Alternative Conceptions on the Greenhouse Effect Revealed in PISA Test Results (PISA 검사 결과에서 드러난 만15세 한국 학생들의 온실효과에 대한 대안적 개념)

  • Kwak, Young-Sun
    • Journal of The Korean Association For Science Education
    • /
    • v.24 no.3
    • /
    • pp.668-674
    • /
    • 2004
  • This study investigated Korean fifteen-year-olds' (mis)conceptions on the greenhouse effect based on the PISA results. Based on previous studies on students' ideas about the greenhouse effect, Korean students'understanding of the natural factors and human-induced factors of the greenhouse effect were analyzed. Students' misconceptions about causes of the greenhouse effect were also examined. In addition to CO2, Students mentioned CFCs, atmospheric pollution, water vapor and methane as greenhouse gases. Many students indicated that the greenhouse effect and ozone depletion have a causal relationship. Teaching implications of the misconceptions were also discussed.

The Study on Performance Characteristics due to the Degree of Superheat in Freon Refrigerating System (The Comparison of Heat Exchanger Types) (프레온 냉동장치의 과열도에 관한 성능 특성 연구 (열교환기 타입별 비교))

  • Jeong, Song-Tae;Ha, Kyeong-Soo;Kim, Yang-Hyun;Park, Chan-Soo;Ha, Ok-Nam;Lee, Seung-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.486-491
    • /
    • 2005
  • Nowadays heat exchangers that have been applied for freon refrigerating systems, a shell and tube type condenser, but because of their large size, large space for installation and more amount of refrigerants are needed. Therefore, in this study, we will find the most suitable operating condition through the comparison of performance between the shell & tube type and shell & disk type heat exchanger with R22. The experiments are carried out for the condensing pressure of refrigeration system from 1500kPa to 1600kPa and for the degree of superheat from 0 to $1^{\circ}C$ at each condensing pressure. As a result of experiment, if the shell & disk type heat exchanger is applied for R22 refrigerating systems, minimized input of refrigerants and space required for installation will be secured, which will have a great contribute to financial improvement for industry.

  • PDF

A Study on the Development of Low Pass Filter for Chopper Gate Control Unit of Electric Rolling Stock (부산도시철도 1호선 전동차 Low Pass Filter 개발연구)

  • Kang, Hyun-Chul;Kim, Hae-Chang;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1445-1456
    • /
    • 2011
  • This paper presents the research of Low Pass Filter(hereinafter called "LPF") which is the part of Chopper Gate Control Unit on the electric rolling stock. Chopper Gate Control Unit controling the propulsive equipments of electric rolling stock consists of several electronic parts, PCB, Power Supply, Gate Circuit Amp, Freon Cooling Device, and has been used the parts made by japan manufacturer Mitsubish. But these parts recently have been more broken down and slow down performance because of long-term use, deterioration. Most of the malfunctions are low performance of LPF. Furthermore, it is physically impossible to repair LPF. Because it is molding type part and no longer manufactured. Also it needs high cost for custom-building. Therefore, it is now making up for through self-developed LPF and operating on Busan metro 1st after on-board testing. This research performed the PS Pice simulation testing, analysis of self-developed LPF performance and the wave form characteristic by multi-function synthesizer, spectrum analyzer, oscilloscope.

  • PDF

Fuel Concentration Measurements by Laser Rayleigh Scattering (레이저 Rayleigh 산란을 이용한 연료농도의 계측)

  • Kwon, Soon-Tae;Kim, Hyeong-Sig;Lee, Jae-Won;Park, Chan-Jun;Ohm, In-Young
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.199-205
    • /
    • 2008
  • In this study, a system to measure continuously the fuel concentration in a steady flow rig on the basis of Rayleigh scattering is presented. The system can be employed to measure both the temporal and the spatial distribution. Also, it is possible to calibrate the system for the measurement of accurate absolute concentration. Firstly, the system was tested at a calibration chamber for the determination of scattering cross section from propane, butane, acetylene, Freon-12 and Genetron 143a. After this, the system was adapted to a steady flow rig to measure the temporal and spatial fuel concentration. The rig is composed of cylinder head, intake manifold, injector, and transparent cylinder which can simulate internal combustion engine. To cope with the problem of Mie scattering interference, a software filter was developed, which is based on the rise time and the time constant of the photomultiplier-amplifier system. The results show that LRS can provide useful informations about concentration field and the software filter is very effective method to remove Mie interference.

  • PDF

UV-cut Finish of Cotton Using Polycarboxylic acid and Vitamin C (폴리카르복시산과 Vitamin C를 이용한 면섬유의 자외선 차단 가공)

  • Lee, Sang-Uk;Choi, Min-Young;You, Mi-Dum;Jang, Jin-Ho
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.11a
    • /
    • pp.30-30
    • /
    • 2011
  • 산업화 과정에 방출된 할로겐 화합물 및 프레온 가스가 오존층을 파괴하면서 많은 양의 자외선이 지표에 도달하여 생태계에 적지 않은 영향을 끼치고 있다. 자외선은 살균, 소독작용 및 Vitamin D 합성을 위해 생명체에 필수적이지만 과다할 경우 색소침착, 피부노화, 피부암 발생, 백내장의 증가, 면역기능저하 등의 피해를 준다. 자외선은 파장 영역에 따라 UV-A(장파장 자외선), UV-B(중파장 자외선)및 UV-C(단파장 자외선)으로 나뉜다. 이 중 인체에 가장 유해한 것으로 알려진 단파장의 UV-C는 파장이 짧아 침투력이 미약해 오존층과 성층권에서 대부분 흡수되므로 생물학적으로 큰 의미는 없다. 그러나 자외선 중 UV-B와 UV-A 영역의 자외선은 인체에 영향을 가장 많이 미치므로 이들 영역의 자외선을 차단하는 것이 필요하다. Vitamin C는 아스코르브산(ascorbic acid)이라고도 불리며 미백효과, 주름 개선, 자외선 차단 및 항산화 작용을 하지만 섬유가공 시 Vitamin C는 쉽게 산화되며 세탁 내구성이 떨어지기 때문에 가교제를 필요로 한다. Vitamin C를 이용하여 자외선 차단성 섬유제품을 개발하기 위해, 포름알데히드를 유리하지 않는 폴리카르복시산 가교제 중 하나인 Citric Acid(CA)를 사용하여 고온에서 면직물에 처리했을 때 에스테르 형 가교를 형성하여 내세탁성을 가질 수 있었다. 자외선 차단 효과를 알아보기 위하여 KS K 0850 섬유제품의 자외선 차단율 및 차단지수 시험방법으로 평가하였다.

  • PDF

A Study on the District Community Cooling System using LNG Cold Energy (LNG 냉열이용 지역집단 냉방시스템에 대한 연구)

  • Kim, Chung-Kyun;Kim, Seung-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.27-30
    • /
    • 2010
  • This paper presents the system design process of district community cooling system using LNG cold energy. The newly developed LNG cooling system includes several heat exchangers, LNG storage tank, thermal mass storage tank, several cold energy storage tanks, gas air-conditioners, compressors, constant pressure regulators, cold energy and hot energy supply pipes. In addition, the gas air-conditioner system is installed to supply not sufficient cold energy due to low level of city gas consumptions during a summer period. This system design is very effective and safe to supply cold energy mass of fresh air by exchanging two thermal masses of an air and 200kcal/kg cold energy of LNG. The district community cooling system with LNG cold energy does not produce CO2 and freon gases in the air.

Technological Progress and Issues on the Recycling of Urban Mine Resources - Comparison of Korea with Japan - (도시광산(都市鑛山) 재자원화기술(再資源化技術)의 진보(進步)와 과제(課題) - 일본(日本)과 한국(韓國)의 비교(比較) -)

  • Oh, Jae-Hyun;Kim, Joon-Soo;Moon, Suk-Min;Min, Ji-Won
    • Resources Recycling
    • /
    • v.21 no.2
    • /
    • pp.17-33
    • /
    • 2012
  • In order to review the recent technological progress and issues on the urban mine resources recycling in Japan and Korea, recycling process of the ELV(End of Life Vehicles) and E-waste(WEEE) were studied. Although technological level for processing of the ELV and E-waste is almost similar in both countries, the treatment of hazadous materials of ELV such as freon, air bag and ASR is unsufficient in Korea. In the E-waste recycling, the technological level is deeply different according to the enterprise size in Korea. Finally, the big R&D project on recycling of urban mine resources sponsored by government in both countries were discussed.

A Study on Performance Characteristics due to the Degree of Superheat in Freon Refrigerating System - The Comparison of Heat Exchanger Types - (프레온 냉동장치의 과열도에 관한 성능 특성 연구 - 열교환기 타입별 비교 -)

  • Hong, Suck-Joo;Ha, Ok-Nam;Kwon, Il-Wook;Yun, Kab-Sig;Hong, Sung-In;Kim, Jin-Hyun;Kim, Yang-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.941-946
    • /
    • 2006
  • Nowadays heat exchangers that have been applied for freon refrigerating systems, a shell and tube type condenser, but because of their large size, large space for installation and more amount of refrigerants are needed. Therefore, in this study, we will find the most suitable operating condition through the comparison of performance between the shell & tube type and shell & disk type heat exchanger with R22. The experiments are carried out for the condensing pressure of refrigeration system from 1,500 kPa to 1,600 kPa and for the degree of superheat from 0 to $10^{\circ}C$ at each condensing pressure. As a result of experiment, if the shell & disk type heat exchanger is applied for R22 refrigerating systems, minimized input of refrigerants and space required for installation will be secured, which will have a great contribute to financial improvement for industry.

Vibration characteristics of an ultrasonic waveguide for cooling (냉각용 초음파 웨이브가이드의 진동 특성)

  • Kim, Hyunse;Lim, Euisu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.6
    • /
    • pp.568-575
    • /
    • 2020
  • Ultrasound has been widely used in various industrial fields. One of challenging application areas is cooling microelectronics. Ultrasonic cooling systems can work with air, argon (Ar) and nitrogen (N2) instead of conventional refrigerant such as freon gas, which can cause global warming. Furthermore, ultrasonic systems do not have moving parts, thus high durability can be obtained. So it is necessary to develop ultrasonic cooling systems due to environmental issues and durability points. In this paper, the design and fabrication processes are explained. When designing the system, a feasibility test was performed with a prototype cooler. Based on the result, finite element analysis with ANSYS software was performed. The predicted anti-resonance frequency for a piezoelectric actuator was 34.8 kHz, which was in good agreement with the experimental result of 34.6 kHz with 0.6% error. In addition, the predicted anti-resonance frequency for the ultrasonic waveguide was 39.4 kHz, which also agreed well with the experimental value of 39.8 kHz with 1.0% error. Based on these results, the developed ultrasonic waveguide might be applicable in microchip cooling.

Determination of the mole fractions of ethylene oxide and freons in medical liquefied gas mixture by GC/AED (GC/AED를 이용한 의료용 액화혼합가스 중 산화에틸렌 및 프레온 가스류의 몰분율 측정)

  • Kim, Hyunjoo;Kim, Dalho;Lim, Arang;Lee, Taeck-Hong;Kim, Jin Seog
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.382-387
    • /
    • 2012
  • Ethylene oxide ($C_2H_4O$, EtO) is used as a raw material for the production of ethylene glycol and other industrially important material such as ethanolamines and also used as a disinfecting agent. It is applied for gas-phase sterilization of thermally sensitive medical equipment, and for processing of storage facilities as a mixture with fluorinated hydrocarbon. In this perspective, accurate determination of the mole fractions of components in the liquefied gas mixture is required for the quality control and safety of production and use. Each component of the liquefied gas mixture has different chemical and physical properties such as vapor pressure and boiling point. Therefore, we can suppose that analytical results can be different according to the introduction method for the gas phase of upper layer, or for the liquid phase of lower layer in gas cylinder. In this study, we designed a new on-line sample injection device for the liquefied gas mixture in liquid or gas state, and applied to the analysis of liquefied gas mixture of ethylene oxide and fluorinated hydrocarbons by GC/AED (gas chromatograph-atomic emission detector). We studied performance of AED, and effect of sample introduction and selected wavelength to the accuracy and repeatability of analytical results.