• Title/Summary/Keyword: 프럭스

Search Result 8, Processing Time 0.017 seconds

Performance Evaluation System for Tow-Channel Ring-Core Flux-Gate Compass (2-체널 링-코어 프럭스-게이트 콤파스의 성능평가 시스템 개발)

  • 임정빈;김봉석
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.11a
    • /
    • pp.13-19
    • /
    • 2002
  • Design and implementation methodologies on the performance evaluation system of two-channel ring-core Flux-Gate Compass (FG-Compass) are described, with evaluation procedures and methods based on the polynomial regression models. Performance evaluation system is consists of a step motor driving unit, a bearing transmitting unit and, evaluation programs using polynomial regression formulae. Through performance evaluation tests, total residual deviation tests, total residual deviation of $\pm$4$^{\circ}$ and eigen residual deviation of $\pm$2$^{\circ}$ are obtained from the FG-Compass. The result is more accurate values than the typical FG-Compass with eigen residual deviation of $\pm$4$^{\circ}$ and is provide a possibility to develop a high performance FG-Compass. In addition, the design methodology of a smart FG-Compass with the self estimation and correction of residual deviations is also discussed.

  • PDF

Performance Evaluation System for Tow-Channel Ring-Core Flux-Gate Compass (2-체널 링-코어 프럭스-게이트 콤파스의 성능평가 시스템 개발)

  • Yim, Jeong-Bin;Jeong, Jung-Sik;Park, Sung-Hyeon;Kim, Bong-Seok
    • Journal of Navigation and Port Research
    • /
    • v.26 no.5
    • /
    • pp.529-535
    • /
    • 2002
  • Design and implementation methodologies on the performance evaluation system of Two-Channel Ring-Core Flux-Gate Compass (TCRC FG-Compass) are described, with evaluation procedures and methods based on the polynomial regression models. Performance evaluation system consists of a step motor driving unit, a bearing transmitting unit and evaluation programs derived from polynomial regression formulae. Newly designed performance evaluation system enabled the accuracy of TCRC FG-Compass to be ascertained. It was confirmed that the size of residual deviation of TCRC FG-Compass is $2^{\circ}$, while that of the conventional one is $4^{\circ}$. In addition, the design methodology to the self estimation and correction of residual deviations is also discussed.

Development of Ship's Digital Compass Using Flux-gate Sensors with High Accuracy (고정밀 프럭스-게이트 센서를 이용한 선박용 디지털 컴퍼스 개발)

  • Yim Jeong- Bin
    • Journal of Navigation and Port Research
    • /
    • v.30 no.5 s.111
    • /
    • pp.321-329
    • /
    • 2006
  • The ultimate target cf this study is to develop ship's Digital Compass that can substitute for conventional ship's Magnetic Compass. At first, a new Digital Compass system consisting of three-axis Flux-gate sensors and small sized step motor was developed Then, new deviation adjustment theory incorporating with Kalman filter method was proposed through which automatic deviation analysis and correction are obtainable without ship's swinging procedures. The effectiveness of developed Digital Compass and proposed deviation adjustment theory are verified throughout the performance evaluation tests on the training ship 'SAE-NU-RI'.

Development of Ship's Digital Compass Based on High Accuracy Flux-gate Sensor (고정밀 프럭스-게이트 센서를 이용한 선박용 디지털 컴퍼스 개발)

  • Yim Jeong-Bin;Saha Rampadha
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.77-85
    • /
    • 2006
  • The last target of this study is to develop ship's Digital Compass that can be substitute with conventional ship's Magnetic Compass. At first, new Digital Compass system was developed with three-axis high accuracy Flux-gate sensors and small sized step motor. Then after, new deviation correction theory without ship's swinging procedures was proposed to provide automatic deviation analysis, correction and renewal. Throughout the performance evaluation tests on the training ship 'SAE-NU-RI', the effectiveness of developed Digital Compass and proposed deviation correction theory are verified.

  • PDF

A Study on the Subcooled Boiling Heat Transfer in a Horizontal Tube (수평관내 냉매의 과냉비등열전달에 관한 연구)

  • 김종헌;김철환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.26-33
    • /
    • 1994
  • A new reliable method to prediet the axial vapor fraction distribution from the measured probability density of the liquid bulk temperature is suggested in this paper. And also the actual quality of the subcooled boiling flow is easily calculated from the liquid bulk temperature. When the heat generating rate is reached to the CHF value, the sharp wall temperature increasing by the wall temperature fluctuation is occurred under the CHF condition. This paper presents the simple wall temperature fluctuation model of transition boiling by the repeating process of overheating and quenching, when the coalescent bubble passes slowly near the wall. Experiments for the subcooled R-113 flow are carride-out in the range of(0.9399~4.461)${\times}10^6$kg/$m^2$hr mass velocity and 10~3$0^{\circ}C$ intel subcooling condition.

  • PDF

Determination of the Convective and Diffusive Fluxes from the Transient Profiles of Solute and Solvent under Evaporation Experiment

  • Wei, Dai;Lee, Sunhoon;Yu, Amemiya
    • Journal of Environmental Impact Assessment
    • /
    • v.11 no.3
    • /
    • pp.173-187
    • /
    • 2002
  • 토양 속에서 발생될 수 있는 용질과 용매의 복합 수송시스템을 대상으로 한 연구 중 회석상태로부터 포화상태에 이르기까지의 넓은 농도분포를 가지는 토양 용액에 적용될 수 있는 물리 화학적 이론에 입각한 지배방정식을 발표한 연구는 전무한 실정이다. 본 연구는 용매와 토양기체간 그리고 용질과 결정간의 상변화를 고려한 연립물질수지방정식을 제시하고, 여기에 타율적 대류를 포함하는 상호확산 분산수송방정식을 도입하여 대류와 확산에 관한 프럭스를 분리, 결정하는 것을 목적으로 한다. 대류 플럭스의 결정은 타율적으로 이루어지는 것이 이론적으로 타당하며, 이러한 타율적 대류 플럭스가 제공된다면 본 연구에서 제시된 지배방정식을 이용해서 토양용액의 복합수송 시스템을 범용적으로 해석, 예측할 수 있을 것으로 판단된다.

Study on the Improvement of Brazeability for Copper-Aluminum Dissimilar Materials Joint (구리-알루미늄 이종재료의 브레이징 특성 향상에 관한 연구)

  • 정호신;배동수;고성우
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.49-57
    • /
    • 2001
  • One of the most important considerations to braze Cu-Al dissimilar materials is control of brittle metallic compound which makes it difficult to obtain a sound brazed joint. Nowdays, several attempts were made to control the metallic compound. But effective method for controlling metallic compound was not established. In this point of view, commercially pure aluminum and copper were used as base metal and Al-Si-X and Zn-Al-X alloy systems were developed as filler metal. Brazing was carried out to find optimum conditions for Cu-Al dissimilar joint. The results obtained in this study were summarized as follows: 1) The joint brazed by Al-Si-X filler metal showed good brazeability and mechanical properties. The tensile strength of the joint brazed over solidus temperature was more than 90% of Al base metal. Especially, the joint brazed at liquidus temperature was fractured in the Al base metal. 2) Fluorides fluxes(a mixture of potassium fluoro-aluminates) were used to improve surface cleanliness of base metal and wettability of Al-Si-X filler metal. It was melted at the temperature about 1$0^{\circ}C$ lower than that of the filler metal, and made appropriate brazing environment. Therefore, it could be a proper selection as flux.

  • PDF

Turbulence Models for the Surface Discharge of Heated Water (표면온배수 난류모형)

  • 최흥식;이길성
    • Water for future
    • /
    • v.23 no.4
    • /
    • pp.445-457
    • /
    • 1990
  • In order to predict the dispersion of a thermal discharge with strong turbulent and buoyant effects, the development of a numerical model using turbulence model and its application are significantly increased. In this study, a 3-dimensional steady-state model for the surface discharge of heated water into quiescent water body is developed. For the model closure of turbulent terms the 4-equation turbulence model is used. For economic numerical simulation, the elliptic governing equations are transformed to the partially parabolic equations. In general, the simulated results by the present model agree well to the experimental results by Pande and Rajaratnam. The model characteristics are presented in comparison with the predicted results of the 2-equation turbulence model by McGuirk and Rodi. Applying the 4-equation turbulence model to the Korea nuclear unit 1 at Kori site, feasibility and efficiency of the present model are validated.

  • PDF