• Title/Summary/Keyword: 풍향.풍속

Search Result 341, Processing Time 0.023 seconds

A Study on the Simplified Prediction Method of Air Resistance for Towing Force Calculation of Disabled Ships (사고선박 예인력 계산을 위한 공기저항 간편 추정법 연구)

  • Kim, Eun-Chan;Choi, Hyuek-Jin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.3
    • /
    • pp.198-204
    • /
    • 2014
  • Ships sailing the seas encounter air resistance. The air resistance depends on the shape of the above-water hull, the ship speed, the wind speed and wind direction. The experimental or statistical methods which are used to predict the air resistance are one of the essential procedures of the calculation of the towing force of the disabled ships. This paper shows simplified air resistance prediction method using the variables of the projected area of the above-water hull, the speed of the ship, the wind speed and its direction. These methods have been applied to the existing computer program which had been set up to predict the towing force of the disabled ships.

Uncertainty Analysis on Vertical Wind Profile Measurement of LIDAR for Wind Resource Assessment (풍력자원평가를 위한 라이다 관측 시 풍속연직분포 불확도 분석)

  • Kim, Hyun-Goo;Choi, Ji-Hwee;Jang, Moon-Seok;Jeon, Wan-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.185.1-185.1
    • /
    • 2010
  • 원격탐사(remote sensing)란 관측 대상과의 접촉 없이 멀리서 정보를 얻어내는 기술을 말한다. 기상관측분야에는 이미 소다(SODAR) 장비가 폭넓게 사용되거 왔으나 최근 풍력자원평가(wind resource assessment)를 위한 풍황측정에 SODAR와 더불어 라이다(LIDAR)가 적극적으로 활용되기 시작하고 있다. 참고로 SODAR(SOnic Detection And Ranging)는 수직 및 동서 남북 방향으로 음파를 발생시키고 대기유동에 의해 산란 반사된 에코를 수신하여 진동수 변화와 반사에코 강도를 측정하여 각 방향의 에코자료를 벡터 합성함으로써 풍향 및 풍속을 산출하는 원리이다. 반면 LIDAR(Light Detection And Ranging)는 비교적 최근에 풍황측정 용도로 개발된 레이저 탐지에 바탕을 둔 원거리 센서로, 공기입자(먼지, 수증기, 구름, 안개, 오염물질 등)에 의해 산란된 레이저 발산의 도플러 쉬프트(Doppler shift)를 이용하여 풍향 및 풍속을 측정하는 원격탐사 장비이다. 풍력자원평가 측면에서 라이다는 그 정확도가 IEC61400-12에 의거한 풍황탑(met-mast) 측정자료 다수와의 비교검증 실측평가(Albers et al., 2009)를 통하여 입증된 바 있다. 한편 한국에너지기술연구원에서 운용 중인 라이다 시스템은 그림 1의 우측 그림과 같이 1초에 $360^{\circ}$를 스캔하여 50지점에서 반사되는 레이저를 스펙트럼으로 측정하되 설정된 관측높이에서 풍속은 샘플링 부피(sampling volume)의 평균값으로 정의된다. 그런데 샘플링 부피는 설정된 관측높이로부터 상하 12.5m, 총 25m의 높이구간에서 관측한 스펙트럼의 평균값을 그 중앙지점에서의 풍속으로 환산하는 알고리듬(algorithm)을 채택하고 있다. 따라서 비선형적으로 변화하는 풍속연직분포 관측 시 풍속환산 알고리듬에 의한 측정오차가 개입될 가능성이 존재하는 것이다. 이에 본 연구에서는 라이다에 의한 풍속연직분포 측정 시 샘플링 부피의 구간 평균화 과정에서 발생하는 불확도(uncertainty)를 정량적으로 분석함으로써 라이다에 의한 풍속연직분포 관측의 불확도를 정량평가하고자 한다.

  • PDF

Flow Analysis indoor Coal Storage Shed due to Wind Velocity and Wind Direction of Ambient Air (외기의 풍속 및 풍향에 따른 옥내저탄장 내부 유동 해석)

  • Kim, Tae-Kwon;Cho, Mok-Lyang;Bae, Young-Wan;Kim, Ji-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.538-545
    • /
    • 2020
  • The outdoor coal storage sheds of thermal power plants are being converted to indoor coal storage sheds worldwide because of the environmental pollution problems in the surrounding areas. On the other hand, indoor coal storage sheds are causing problems, such as indoor coal scattering and harmful gas generation. In this study, the ventilation method of indoor coal storage sheds was analyzed in terms of the internal flow characteristics and ventilation according to the outside wind velocity and direction. CFD analysis was performed based on the actual flow measurement information inside the indoor coal storage sheds. A comparison of the wind speed of 6 m/s and 2 m/s when the outside wind direction was easterly showed that the stream velocity to the monitor louver was faster and the recirculation area was clearer at 6 m/s than at 2 m/s. In addition, the trend of a westerly wind was similar to that of the easterly wind. The ventilation rate according to the wind speed was 13.1 times and 4.4 times for a wind speed of 6 m/s and 2 m/s, respectively. If the wind speed is 2 m/s, the situation does not meet the required number of ventilations per hour in a general plant, and needs to be improved.

Efficient Control of an Air Conditioner Using Thermal Image and a Fuzzy Control Method (퍼지 제어 기법과 열 영상을 이용한 에어콘의 효율적 제어)

  • Kim, Kwang-Baek;Woo, Youn-Woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2201-2206
    • /
    • 2010
  • The shortage of fossil fuel drives researchers to find a new way to increases energy efficiency. In this paper, we propose a method to control the direction and speed of an air conditioner using a thermal image and fuzzy controlling method, which results in the increase of energy efficiency. The thermal image is first converted into a color temperature image which represents the temperature range from $24.0^{\circ}C$ to $27.0^{\circ}C$. The temperature image is divided into 5 columns and the distribution of them is used to analyze room temperature and control an air conditioner. The proposed method was applied to 300 by 400 thermal images. When the performance of the proposed method was compared to existing systems in energy efficiency, the proposed method was better than existing methods, which is clear from experimental results.

Statistical Estimation of Wind Speed in the Gwangyang-Myodo Region (광양 - 묘도 지역의 통계학적인 풍속 추정)

  • Bae, Yong Gwi;Han, Gwan Mun;Lee, Seong Lo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.197-205
    • /
    • 2008
  • In order to estimate mean wind speed in the Gwangyang-Myodo Region, the probability distribution model of extreme values has been used in the statistical analysis of joint distribution probability of daily maximum wind speed and corresponding direction in this paper. For this purpose frequency of daily maximum records at respective stations is inquired into and sample of largest yearly wind speed of sixteen compass direction and non-direction is extracted from daily data of maximum wind speed and appropriate direction of the meteorological observing stations nearby the bridge construction site. These extreme speed records are applied to Gumbel and Weibull distribution model and parameters are estimated through method of moment and method of least squares etc. And also, distribution and parameters are inquired into whether it is fitted through the probability plot correlation coefficient examination. From fitted parameters the largest yearly wind speed of sixteen compass direction and non-direction is extrapolated taking into account factors regarding sample size of data and distance from the bridge construction site according to the appropriate stations.

The Analysis of Wind Data at the Cities in Korea with Meteorological Administration Data -Wind Data Analysis in 32 Cities During 30 Years- (기상청 자료를 이용한 도시의 바람자료 분석 연구 - 32개 도시의 30년간 바람자료 분석 -)

  • Yoon, Jae-ock
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.5-12
    • /
    • 2003
  • Using the wind, we can get a thermal comfort in summer. In winter we must shut out the wind. To achieve sustainable environmental building design, especially wind data is very important. The wind direction and wind velocity of 32 cities were analyzed to suggest the wind map of Korea. The weather data which was used in this paper was from National Weather Service(19711.1~2000.12.31). The results of this study are 1) The monthly wind velocity of Seoul is 1.1m/s-3.8m/s. 2) The maximum wind velocity could be estimated from the annual average wind velocity. The regression curve is Y(The maximum wind velocity)=6.369732 X(annual average wind velocity) + 6.391668 (P< 9.66E-12). 3) The wind velocity at the inland area which is far from 25km sea side is smaller than coastal area. The distance from the sea is major index of wind velocity. 4) The monthly wind direction was compared inland area with coastal area. 5) The uniform-velocity line on the Korean map was obtained.

Technique of Measuring Wind Speed and Direction by Using a Roll-rotating Three-Axis Ultrasonic Anemometer (II) (롤 회전하는 3축 초음파 풍속계를 활용한 풍향 풍속 측정기법(II))

  • Chang, Byeong Hee;Lee, Seunghoon;Kim, Yang won
    • Journal of Wind Energy
    • /
    • v.9 no.4
    • /
    • pp.9-15
    • /
    • 2018
  • In a previous study, a technique for measuring wind speed and direction by using a roll-rotating three-axis ultrasonic anemometer was proposed and verified by wind tunnel tests. In the tests, instead of a roll sensor, roll angle was trimmed to make no up flow in the transformed wind speeds. Verification was done in point of the residual error of the rotation effect treatment. In this study, roll angle was measured from the roll motor encoder and the transformed wind speed and direction on the test section axis were compared with the ones provided to the test section. As a result, up to yaw $20^{\circ}$ at a wind speed of 12 m/sec or over, the RMS error of wind speed was within the double of the ultrasonic anemometer error. But at yaw $30^{\circ}$, it was over the double of the ultrasonic anemometer error. Regardless of wind speed, at yaw $20^{\circ}$ and $30^{\circ}$, the direction error was within the double of the ultrasonic anemometer error. But at yaw $10^{\circ}$ or less, it was within the error of the ultrasonic anemometer itself. This is a very favorable characteristic to be used for wind turbine yaw control.

The Influence of Wind Conditions on the Performance of Smoke Ventilation in High-rise Building Fires (초고층건물 화재시 외기바람이 배연성능에 미치는 영향)

  • Kim, Beom-Gyu;Yim, Chae-Hyun;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.63-73
    • /
    • 2016
  • This study examined the effects of the wind conditions, such as wind velocity and wind directions, on the performance of the mechanical smoke exhaust systems for high-rise building fires. A scaled model design and CFD simulations were used to verify the effects both quantitatively and qualitatively. The results showed that the smoke exhaust velocity of the mechanical exhaust system can be reduced by up to 17% at a wind velocity of 5 m/s (equivalent to an outdoor wind speed of 16 m/s) and a wind direction of ${\theta}=5^{\circ}$. In addition, the angle of the outdoor wind direction below ${\theta}=25^{\circ}$ had a significantly influence on the smoke exhaust flow rate and reduced exhaust performance of the smoke exhaust system in a fire.

Analyses on the sea surface wind field data by satellite remote sensing (위성원격탐사를 활용한 해양표면 바람장 자료 분석)

  • Yoon, Hong-Joo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.149-157
    • /
    • 2008
  • If we use the microwave of SAR, we can observe ocean in spite of severe weather or night time. The sea surface image of SAR has numerous information about atmospheric phenomena related to surface wind field. The extracted wind information from SAR can be used diversely. In order to extract sea wind speed from SAR image, a generated wind direction from SAR and sigma nought should be input into wind model. Therefore, wind speed can be obtained by input wind direction into CMOD5 Model. Azimuth angle using CMOD5 Model is generated by added $90^{\circ}$ to Look angle which is extracted from SAR data file. A gained wind direction spectrum from SAR image has $180^{\circ}$ ambiguity because of 2D-FFT. This ambiguity should decide to use the location of land, wind direction in field or the result of numerical model. Consequently, wind direction using 2D-FFT is $3^{\circ}{\sim}7^{\circ}$ differences with actual surveying data. Wind speed by CMOD5 model is similar to actual surveying data as below 2m/s.

Control of Wind Velocity Using Temperature of Bodily Sensation and Fuzzy Logic (체감 온도와 퍼지 논리를 이용한 풍속 제어)

  • Kim, Jae-Yong;Ha, Yan;Kim, Seong-Hoon;Kim, Kwang-Beak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.320-322
    • /
    • 2009
  • 본 논문에서는 에너지 소비를 효율적으로 절약하기 위한 방법으로 평면도 상의 색상 분포 영상, 벽색상 분포 영상, 습도를 퍼지 추론 규칙에 적용하여 풍향 및 풍속을 제어하는 방법을 제안한다. 기존 제어 방법의 시뮬레이터는 소비 전력을 풍속에 관계없이 8.3KW로 설정하여 계산하기 때문에 풍속이 강하거나 약하더라도 시간 당 소비되는 전력이 같다는 문제점이 있었다. 그러나 본 논문에서 제안된 시뮬레이터에서는 풍속이 강할 수 록 소비되는 전력을 크게 설정하고, 풍속이 약할 수 록 소비되는 전력을 적게 설정한다. 제안된 풍속 제어 방법을 $400{\times}300$ 크기의 평명도 색상 영상 50장과 $400{\times}200$ 크기의 벽 색상 분포 영상 50장을 대상으로 기존의 풍속 제어 방법과의 전력량 차이를 시뮬레이션 한 결과, 기존의 방법보다 에너지 절약이 개선된 것을 확인하였다.

  • PDF