• Title/Summary/Keyword: 풍향

Search Result 529, Processing Time 0.043 seconds

A Study on the Application ratio of Directional wind speeds Characteristics by Gumbel Model Simulation Using Directional wind Patterns (풍향패턴에 따른 굼벨 모델 시뮬레이션에 의한 풍향풍속성의 적용율 평가에 관한 연구)

  • Chung, Yung-Bea
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.573-580
    • /
    • 2010
  • In this study, an assessment method that considers the effects of directional wind speeds on buildings or structures that are sensitive to wind is proposed. Also, the basic characteristics of directional wind speeds were assessed by means of local annual maximum wind speeds. From the method of assessment of the characteristics of directional wind speeds, their goodness-of-fit was verified by applying extreme value distribution to the data on annual maximum wind speeds from the Korea Meteorological Administration. To consider the characteristics of directional winds, an assessment method is suggested that divides the directional wind pattern of each directional wind speed into four groups. From the study results, all the data on directional wind speeds based on the Gumbel distribution were examined using data on annual maximum wind speeds from Seoul, Tongyung, and Incheon. Since the Gumbel model of all directional wind speeds has independent probability characteristics that govern the 4 directional wind pattern groups, the application ratio proposed was based on the assessment of these four groups. According to the goodness-of-fit of the data on the annual maximum wind speeds based on the Gumbel distribution, new application ratios were proposed that consider the directional wind speeds in Seoul, Tongyung, and Incheon.

A Study for the measurement of the 3D direction and velocity of the wind on the sphere surface using two 2D-anemometers (두 개의 2차원 풍향풍속센서를 이용한 송전선 볼센서 구 표면에서의 3차원 풍향풍속 측정 방안에 관한 연구)

  • Cho, Nam-Kyu;Lee, Dae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.472-473
    • /
    • 2008
  • 최근 전력 공급의 안정성을 위해 송전선로에 각종 센서를 볼형태(볼센서)로 장착하여 철탑 및 송전선의 위험 상태를 실시간으로 모니터링해야 하는 필요성이 증대되고 있는데, 본 연구에서는 볼센서의 장착 특성으로 인해 구 표면에 3차원 풍향풍속센서 1개로 3차원 풍향풍 속이 측정 불가능한 문제점을 해결하고자, 2개의 2차원 풍향풍속센서의 측정 데이터를 이용하여 3차원 풍향풍속을 산출하는 방안에 대해 기술하였다. 구 표면을 따르는 풍속 및 풍압 유동해석 결과를 바탕으로, 먼저 구 표면을 따르는 2개의 풍향벡터를 통해 실제 풍향을 산출하고, 실제 풍향에 상대적인 센서 위치에 따른 해석결과에 기준해 보정처리를 함으로써 실제 풍속을 산출하는 방안에 대한 연구를 수행하였다.

  • PDF

Temperature and Wind Control of Virtual Warmth Image Using Fuzzy Reasoning Rule (퍼지 추론 규칙을 이용한 가상의 열 영상 온도와 풍향 제어)

  • Kang, Kyoung-Min;Kim, Kwang-Baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.387-392
    • /
    • 2008
  • 본 논문에서는 에너지 절약을 위한 방법으로 여름철 냉방의 적정 온도 및 풍향을 제어하기 위한 가상의 시뮬레이션을 목적으로 열 영상과 퍼지 추론 규칙을 적용한 온도 및 풍향 제어 기법을 제안한다. 온도 제어를 위한 가상 시뮬레이션에서 열 영상을 분석하기 위해서 영상을 $300{\times}400$의 크기를 가지는 색상 분포 영상으로 변환한다. 색상 분포 영상은 Red, Magenta, Yellow, Green, Sky, Blue의 온도 값을 가지는 R, G, B 값이며 각 색상은 $ 24.0^{\circ}C$에서 $27.0^{\circ}C$의 분포의 온도 값을 가진다. 색상 분포 영상은 아래 계층부터 레벨1에서 레벨10의 높이 계층으로 분류한다. 분류한 각 계층은 고유의 색상 분포도를 가지며 색상이 가지는 온도 수치에 따라서 계층별로 온도를 구성한다. 풍향 제어를 위한 각 계층의 높이는 레벨1에서 레벨3까지는 하위층이며, 레벨 4부터 레벨 7은 중간층, 레벨 8부터 레벨 10은 상위층으로 분류한다. 각 계층의 온도와 높이 레벨 값은 온도 조절과 풍향의 우선 순위, 강도 조절, 지속 시간을 구하기 위한 파라미터이다. 실내 공간의 전체적인 온도의 균형과 풍향을 제어하는 과정으로 풍향의 방향, 지속시간을 적용하고 풍향의 강도를 구하기 위해서 색상 분포영상의 각 구간의 온도 및 높이의 특징을 적용하여 퍼지 소속 함수를 설계한 후, 소속 함수의 소속도를 구하고 퍼지 추론 규칙을 적용하여 풍향의 강도를 구한다.

  • PDF

Load Ratio between Two Adjacent Wings of Load Cell Type Anemometer according to Wind Direction (풍향에 따른 로드 셀형 풍향풍속계의 인접한 두 날개 사이의 하중 비)

  • Han, Dong-Seop
    • Journal of Navigation and Port Research
    • /
    • v.36 no.5
    • /
    • pp.357-361
    • /
    • 2012
  • Anemometer is a meteorological instrument that measures wind direction and wind speed in real time, and is mounted to the cranes that are used at ports, shipbuilding yards, off-shore structure, or construction sites that are influenced by wind, and it is used in conjunction with the safety system. Load cell-type anemometer measures the wind direction through the ratio of load between 4 positions by mounting the thin plate to 4 load cells, and measures wind velocity through the summation of loads. In this study, we compared and analyzed the results in the theoretic approach, analytic approach and experimental approach to derive the correlation between load ratio and wind direction. Wind direction was selected as the design variable, and selected 9 wind direction conditions from $0^{\circ}{\sim}90^{\circ}$ with $11.25^{\circ}$ space for analysis, and 10 wind direction conditions with $10^{\circ}$ space for experiment.

Development of Load-Cell-Based Anemovane (로드셀형 풍향풍속계 개발)

  • Jeon, Byeong Ha;Han, Dong Seop;Lee, Kwon-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.5
    • /
    • pp.685-691
    • /
    • 2013
  • A load-cell-type anemovane operates based on wind vector properties. The developed load-cell-type anemovane is of a fixed type in which the wing does not rotate, unlike in the case of existing anemovanes. The load-cell-type anemovane is required to accurately derive the correlation between the load ratio and the wind direction in order to develop a qualified product. This is because the load ratio repeats every $90^{\circ}$ owing to the use of four load cells, and its value varies nonlinearly according to the wind direction. In this study, we compared analytical results with experimental results. Fluid analysis was carried out using ANSYS CFX. Furthermore, the prototype was tested using a self-manufactured wind tunnel. The wind direction was selected as the design variable. 13 selected wind direction conditions ranging from $0^{\circ}$ to $90^{\circ}$ with an interval of $7.5^{\circ}$ for analysis were defined. Furthermore, 10 wind direction conditions with an interval of $10^{\circ}$ for the experiment were defined. We derived the relations between the pressure ratio and the wind direction through the experiment and fluid analysis.

A Study on Improvement Plan for Selection of Evacuation Site through Analysis of Meteorological Data -Focus on Incheon·Siheung·Ansan- (기상관측자료 분석을 통한 위해관리계획 주민대피 장소 선정 개선방안 연구 -인천·시흥·안산 지역을 중심으로-)

  • Jeon, Byeong-Han;Kim, Hyun-Sub;Oh, Seung-Bo;Kim, Hee-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.16-22
    • /
    • 2017
  • This study examined the status of resident evacuation sites notified to nearby communities, centered on business sites subject to the risk management plan of Incheon, Siheung, and Ansan. Through an analysis of the meteorological data, the direction of improvement of the site selection process for the safe evacuation of chemical accidents was studied. Among a total of 111 evacuation sites, 30 schools were selected the most, and 2-3 sites were usually selected for evacuation. As a result of an analysis of the Incheon meteorological data of 2016, the frequency of occurrences was 18.8525% in the NNE wind direction, 18.0328% in the NNW wind direction, 12.2951% in the WSW wind direction, 9.0164% in the SSE direction, 8.4700% in the SW direction, 6.5574% in the W direction, and 5.7376% in the S direction. The NNE wind direction showed the highest frequency, but the other winds showed a relatively high frequency, indicating that the annual wind direction was not biased toward one side.

A Study on the Improvement of the Mast Design for Wind Detector (풍향풍속 검출기 마스트 설계 개선에 관한 연구)

  • Kim, Dong-Young;Park, Hae-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.98-107
    • /
    • 2021
  • During the sea trial test for the aerovane in AOE-II, a malfunction occurred in the wind detector movement around 40 to 90° on the starboard side and around 270 to 320° on the port side. The purpose of this study was to analyze and improve the cause of the above phenomenon. The wind detector was covered with a mast structure and was not affected directly by the blowing wind, and a vortex air current was formed behind the mast structure, causing the motion malfunction. The above problem was solved by moving and installing the wind detector on the newly installed mast yard. After conducting vibration analysis and reviewing the effects of vibration, the wind detector was installed in the new mast yard and verified by a sea trial test. Since the improvement plan was slightly effective, the position of the wind detector moved away from the mast on the new mast yard and was re-verified through a sea trial test. The movement malfunction of the wind detector did not occur, confirming that it is an appropriate improvement plan.

Preliminary Evaluation of Sources of Ambient Trace Metals using Wind Speed and Wind Direction (풍속과 풍향을 이용한 대기중 미량금속의 오염원에 대한 예비적인 추정)

  • 장미숙;이진홍
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.55-56
    • /
    • 2002
  • 풍속과 풍향은 지역의 오염원 추정에 중요한 변수가 되므로 풍속에 따른 오염물질 농도 및 풍향을 고려한 pollution rose를 통해 기상조건과 오염물질 농도의 관련성을 분석하고, 대상 지역의 오염원을 개괄적으로 추정하고자 한다. (중략)

  • PDF

Control on Wind Speed and Direction of Electric Fan using A.I Fan Sensor (A.I Fan 센서를 이용한 선풍기의 풍향 및 풍속 조절)

  • Kwon, Young-Geun;Choi, Sae-Hoon;Han, Young-Sam;Kim, Myoung-Jin;Park, Chae-Seo;Hur, Joon;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.81
    • /
    • pp.7-19
    • /
    • 2007
  • 본 논문은 초음파센서와 적외선센서를 이용하여 그 신호를 받아 주 모터를 제어한 것으로, 센서를 이용한 선풍기의 풍향 및 풍속을 제어하였다. 풍향제어는 인체감지센서와 ATmega128, DC모터를 사용하였고, 기본적으로 WmAVR과 PonyProg를 사용하여 소스코딩 및 다운로딩을 하였으며, 모터 구동드라이버는 모터제어에 범용으로 쓰이는 L298 칩을 사용하였다. 풍속제어는 초음파센서와 ATmeBa16, DC모터를 사용하여 제작하였고, 풍향제어부와 마찬가지로 WinAVR과 PonyProg 및 L298 칩을 사용하여 소스코딩 및 다운로딩을 하였다. 풍향제어는 물체가 정면에 위치하면 회전을 멈추고, 좌우로 $100^{\circ}$ 반경이내에서 거리 1m내외의 물체를 감지하도록 설계하였다. 풍속제어는 물체까지의 거리를 최소 3cm 최대 3m 이내에서 물체를 감지하여 모터의 속도를 제어할 수 있도록 하였고, 모터속도는 DC모터를 PWM 방식으로 제어하여 속도를 조절하였다.

A micro wind sensor fabricated using MEMS technology (MEMS 기술을 이용한 초소형 풍향 풍속 센서)

  • Yoo, Eun-Shil;Shin, Kyu-Sik;Cho, Nam-Kyu;Pak, Jung-Ho;Lee, Dae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1468-1469
    • /
    • 2008
  • 기상관측 분야에서는 풍속센서의 소형화 요구가 커지고 있어 Air flow sensor를 이용한 MEMS(Micro Electro Mechanical System) 풍향 풍속센서의 응용연구가 활발하다. MEMS 풍향 풍속 센서는 수 mm 크기를 가지면서도 바람의 세기와 함께 방향을 측정하여야 하는데, 센서 칩이 노출되어 있어 외부환경으로부터 영향을 받기 때문에 센서소자의 내오염성과 내구성 확보가 중요하다. 따라서 본 연구에서는 절연막으로 비점착성의 테프론 막을 적용하여 외부환경으로부터 영향을 줄일 수 있는 열감지 방식의 MEMS 풍향 풍속 센서 칩을 제작하였다. 테프론 코팅막을 이용한 풍향 풍속 센서는 0.1m/s의 resolution을 가지며, 최대 15m/s까지 측정이 가능하여, 오염에 강하고 발수성을 센서를 제작하였다.

  • PDF