• Title/Summary/Keyword: 풍하중 평가 방법

Search Result 37, Processing Time 0.025 seconds

Static Wind Fragility Analysis of an Extradosed Bridge (엑스트라도즈드교의 정적 풍하중 취약도 분석)

  • Kim, Doo Kie;Kim, Dong Hyawn;Seo, Hyeong Yeol;Lee, Chang Ju
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.107-113
    • /
    • 2007
  • This study presents fragility curves for the wind fragility analysis of a six-span extradosed bridge. The loads and corresponding load combinations are calculated using domestic design codes. Random variables are utilized to considering the uncertainties of the input variables for wind loads. The fragility curve is represented as a log-normal distribution function, in which two parameters are estimated by the maximum likelihood method. The results show that the extradosed bridge is safe to suffer static wind forces.

A Study on the Equivalent Static Wind Load Estimation of Large Span Roofs (대스팬 지붕구조물의 등가정적 풍하중 산정에 관한 연구)

  • Lee, Myung-Ho;Kim, Ji-Young;Kim, Dae-Young;Kim, Sang-Dae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.1 s.19
    • /
    • pp.83-90
    • /
    • 2006
  • The GF(Gust Factor) method is usually used as a method to evaluate equivalent static wind loads for general structures. The GF method is performed on the assumption that the shape of the equivalent static wind load profile is typically similar to that of mean wind loads. The shape of fluctuating wind loads could be quite different with that of the mean wind loads in case of large-span structures. So, the effect of higher modes as well as first mode must be considered to evaluate the wind loads. In this study, the ACS (Advanced Conditional Sampling) method is suggested to evaluate of equivalent static wind loads after investigating about GF and LRC method. The An method ran derive effective static wind loads by combining wind pressures and inertia forces of a structure chosen at a maximum load effect. The maximum load effect is assessed with the time history analysis using pressure data measured in wind tunnel tests. Equivalent static wind loads evaluated using ACS, GF, and LRC methods are compared to verify the effectiveness of ACS method.

  • PDF

Structural countermeasure for wind-induced vibration of suspension bridge catwalks (현수교 캣워크의 구조적 진동억제 대책)

  • Lee, Han-Kyu;Lee, Seung-Ho;Kwon, Soon-Duck;Kim, Jong-Hwa
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.84-87
    • /
    • 2011
  • 본 연구에서는 버페팅 해석을 통해 현수교 캣워크에 작용하는 풍하중에 대한 정적 및 동적 응답을 알아 보고 진동 억제 대책을 제시하였다. 캣워크는 영구구조물이 아닌 임시구조물이기 때문에 그동안 절적한 평가가 수행되지 못하였다. 따라서 본 연구는 풍하중에 의한 캣워크의 동적 응답을 해석적인 방법을 통해 알아보았으며, 동적 변위를 산정하기 위해 시간이력 해석 방법을 통해 버페팅 해석을 수행하였다. 그 결과로 부터 캣워크의 수평변위를 억제하기 위해 주케이블을 시공중에 연결하는 방법과 스테이 로프를 설치하는 방법을 제시하였다.

  • PDF

Application of LRBs for Reduction of Wind-Induced Responses of Coupled Shear Wall Structures (전단벽 구조물의 풍응답 저감을 위한 LRB의 적용)

  • Park, Yong-Koo;Kim, Hyun-Su;Ko, Hyun;Kim, Min-Gyun;Lee, Dong-Guen
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.47-56
    • /
    • 2011
  • In general, shear walls are employed as lateral resistance system. Most of shear wall structures require openings in shear walls and thus shear walls are linked by floor slabs or coupling beams resulting in the coupled shear wall structures. In this study, an LRB (lead rubber bearing) was introduced in the middle of the coupling beam of the coupled shear wall structures and the wind-induced response reduction effect of this system was investigated. In order to evaluate the control performance of the proposed method, 20- and 30-story building structures were used as example structures and boundary nonlinear time history analyses have been performed using artificial wind excitation. Japanese vibration evaluation criteria was employed to evaluate whether the proposed system could improve the serviceability of the tall coupled shear wall structures under wind excitation. Based on analytical results, it has been shown that the proposed method that connects shear walls with LRBs can improve the wind-induced response control effect.

Improvement of Flexural Structural Performance and Applied Section Shape for Sound Proof Wall Structures Using Glass Fiber Reinforced Polymer(GFRP) (GFRP를 활용한 도로 방음벽 구조물의 구조성능 및 단면형상 개선에 관한 연구)

  • Jung, Woo-Young;Choi, Hyun-Kyu
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.9-15
    • /
    • 2009
  • This research presents the structural performance and an improving technique for flexural capacity of road safety facilities based on the damage cases by wind pressure. Among road safety facilities, a support frame of soundproofing walls is considered as a prototype structure and its corresponding structural behaviors and section design are performed mainly by analytical and experimental studies. On the basis of analytical results, glass fiber reinforced polymer(GFRP) with an epoxy matrix which is high stiffness-to-weight ratio was used for applied one of strengthening techniques and their results shows that support frame strengthened by GFRP is the most effective compared to other cases proposed in this research for advancing its flexural improvement, Finally, optimum section design was performed analytically to evaluate wind-resistance capacity and its result would be very useful for developing a practical design guideline for Road safety facilities under strong wind.

  • PDF

Half-Scaled Substructure Test for the Performance Evaluation of a Transmission Tower subjected to Wind Load (송전철탑의 내풍안전성 평가를 위한 1/2축소부분구조 실험)

  • Moon, Byoung-Wook;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.641-652
    • /
    • 2007
  • In this paper, a half-scaled substructure test was performed to evaluate the buckling and structural safety of an existing transmission tower subjected to wind load. A loading scheme was devised to reproduce the dead and wind loads of a prototype transmission tower, which uses a triangular jig that is mounted on the reduced model to which the similarity law of a half length was applied. As a result of the preliminary numerical analysis carried out to evaluate the stability of a specimen for the design load, is was confirmed that the calculated axial forces of tower leg members were distributed to $80{\sim}90%$ of an admissible buckling load. When the substructured transmission tower was loaded by 270% of its maximum admissible buckling load, it was failed due to the local buckling that is occurred in joints with weak constraints for out-of-plane behavior of leg members. By inspection of load-displacement curves, displacements and strains of members, it is considered that this local buckling was due to additional eccentric force by unbalanced deformation because the time that is reached to yielding stress due to the bending moment is different at each point of a same section.

Computational Analysis of Vortex Structures around Wall-Mounted Bluff Body in Boundary Layer (경계층 내에 위치한 각진 물체 주위의 와류 전산 해석)

  • Lee, Ju-Yong;Kim, Hyeon-U;Lee, Seung-Su
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.354-359
    • /
    • 2013
  • 일반적으로 건축물의 설계시 풍동 실험을 통한 풍환경의 평가를 수행하고 있으며, 이는 환경 영향 평가법에서 정한 건축 사업 시행 시 수반되어야 할 자연환경, 생활환경 그리고 사회경제환경의 영향 평가의 일환으로 실시되고 있다. 그러나, 풍동 실험의 경우 여러 가지 현실적 제약조건으로 설계와 실험의 피드백 (Feedback)이 원활하지 못하며, 특히 대상 건축물이 공장과 같이 대기 오염원이 되는 경우 실험은 더욱 어려운 형편이다. 이에 대한 보완책으로 전산 유체 역학을 이용한 건축물의 풍압 해석에 의한 풍하중 추정이나 인접 지형-지물의 영향을 고려한 건축물 주위의 풍환경 평가가 있다. 전산 모사에 의해 풍동 실험의 미비점을 보완하고, 보다 상세한 정보를 확보함으로써 건축물의 구조적 안전성의 증대와 환경 피해 감소를 기할 수 있다. 그러나 복잡한 지형-지물이나 건축물 주위의 풍환경에 대한 전산 모사는 주로 두 가지의 기술적 어려움을 수반하게 되다. 그 중 하나는 고정 경계면을 이루는 형상의 복잡성으로 인해 기존에 많이 이용하고 있는 Body-fitted 격자계를 이용하는 경우, 격자 생성 과정이 매우 복잡하고 어려울 뿐 만 아니라 생성된 격자가 주로 비정렬 (unstructured) 특성을 갖게 되어 수치해석 과정의 효율을 저하시키는 요인이 되며, 격자의 형상도 수치해석의 수렴성을 저하시키는 예가 많다. 다른 어려움으로 풍환경은 전형적인 난류 유동장으로서 난류의 전산 해석은 아직도 해결하지 못한 부분이 많다는 점이다. 이에 본 논문에서는 복잡한 지형-지물이나 건축물의 풍하중과 풍환경의 전산 모사 기술 확보를 위하여 수행중인 연구의 일환으로 물체 형상의 기하학적 복잡성의 극복을 위한 가상경계법 (Immersed Boundary Method)과 난류 유동장의 물리적 엄밀성을 높이기 위한 다와동 모사 (Large Eddy Simulation)을 이용한 물체 형상과 무관한 유동장 해석 기술 개발에 대하여 다루고자 한다. 먼저 최근에 유동 해석에 이용되는 방법인 가상경계법(IBM)은 물체를 포함한 전체 전산 영역을 직교 좌표계에 의해 이산화하고, 유동장내 존재하는 물체의 표면에서의 점착 조건을 만족시키기 위하여 지배 방정식에 적절한 외력을 추가로 고려하는 방법이다. 본 연구에서는 가상경계법을 이용하여 경계층에 위치한 건물 형상의 각진 물체 주위 사이에 형성되는 공동 내부의 비정상 유속 및 압력에 대한 전산 해석을 수행하고, 풍상측 전면에 형성되는 경계층에 의한 영향을 분석하였다.

  • PDF

Estimation Method of the Design Wind Load of Soundproof Wall Using GIS (GIS를 이용한 방음벽의 설계풍하중 산정방법)

  • Lee, Dong-Ho;Choi, Se-Hyu
    • Spatial Information Research
    • /
    • v.23 no.5
    • /
    • pp.75-85
    • /
    • 2015
  • Recently deformed or destroyed of soundproof wall by local winds and typhoon has increased. This research proposed the estimation method of the design wind load of soundproof wall using spatial information analysis based on 1:5,000 digital map and performed comparative analysis with actual application cases. According to the result of quantitative evaluation using GIS, the surface roughness in the downtown area packed with buildings was III and the surface roughness in the suburban district with a relatively small number of buildings was II and the surface roughness in the district packed with open areas and typical farmhouses was I. This shows that the wind load of the soundproof walls reflecting the actual surface conditions was estimated. If the quantitative GIS analysis presented in this study is applied to wind-resistant design of soundproof walls, it is supposed that this will be helpful in more rational wind-resistant design by remedying the existing problem in which the wind load varies depending on designer's subjectivity.

Safety Assessment for the Solar Cell Structure using Finite Element Analysis (유한요소법을 이용한 태양광 집전기 구조물에 대한 안전성 평가)

  • Lee, Yang-Chang;Lee, Joon-Seong;Lee, En-Chul;Lee, Ho-Jung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.881-884
    • /
    • 2009
  • 태양열을 이용한 발전은 신재생에너지 사업으로 현재 각광을 받고 있는 분야 중의 하나이다. 본 논문에서는 3kv급 태양열 집전기를 유한요소법을 이용하여 돌풍이 불 때 풍하중에 의한 안전성을 평가하였다. 태양열 집전기는 옥외에 설치가 되므로 바람에 대한 영향을 가장 많이 받게 되는데 풍하중은 특히 강한 태풍이 불 때에 가장 높은 설계변수로 자중이나 프레임이 태양을 트레킹 할 때 생기는 동역학적인 변수보다도 크게 된다. 기존에 풍압력에 대한 산술식이 있지만 구조에 따라 적용하는 방법이 다르므로 돌풍이 불 때의 풍속을 적용, 유한요소법을 이용하여 우선 플레이트 프레임 표면에 발생하는 표면 압력을 계산하였다. 구한 표면 압력으로부터 플레이트 부분에 작용하는 하중으로 환산을 구조물에 대입하였고, 구조물이 크고 Mesh수에 문제로 인해 프레임을 두 부문으로 나누어서 포스트 부문과 플레이트 부분에 적용하여 해석하였다. 포스트의 경우에는 플레이트에서 받은 풍하중을 벡터로 나누어서 적용하였고 플레이트 부분에서 작용하는 자중을 고려하여 적용하였다. 플레이트의 경우 돌풍에 안정적이라 하더라도 변형량이 높을 경우를 적용하였다. 포스트 부분과 플레이트 연결부에서도 보강을 통하여 적정범위의 응력이 집전기에 문제가 발생할 수 있으므로 적정한 범위의 변형량을 유지하기 위해 설계변경 하여 안전한 구조물이 되도록 하였다.

  • PDF

Design of an Excitation System for Simulating Wind-Induced Response and Evaluating Wind-load Resistance Characteristics (건축구조물의 풍하중 구현 및 풍특성 평가를 위한 가진시스템 설계)

  • Park, Eun-Churn;Lee, Sung-Kyung;Min, Kyung-Won;Chun, Lan;Kang, Kyung-Soo;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.769-778
    • /
    • 2007
  • In this paper, excitation systems using linear mass shaker (LMS) and active tuned mass damper (ATMD) are presented in order to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. Filter and envelop function are used such that the error between the wind and actuator induced responses is minimized by preventing the actuator from exciting unexpected modal response and initial transient response. The analyses results from a 76-story benchmark building problem in which wind load obtained by wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately embody the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.