• Title/Summary/Keyword: 풍우현상

Search Result 4, Processing Time 0.009 seconds

Shear Force Variation of Stiffening Girder caused by Vibration of Stay Cable (사장 케이블 진동에 의한 보강형의 전단력 변화)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.1-8
    • /
    • 2009
  • Stay cable is easily exposed to vibration induced rainy wind effects. There are some problems for not only unexpected vibration but also well-known vibration. An outbreak of displacement by the said effects brings damages such as over-tension of cables and barriers, fatigue of anchorages and dampers, and additional shear force variation of stiffening girders. This study suggests analytic methodology for dynamic tension variation of cables and shear force variation of stiffening girders. Additionally this study announces with dynamic problems for cable stayed bridge briefly. To realize this subject, we divide restoring force into chord component and normal component and then make up the differential equations which can satisfy physical phenomenon for each component. Finally we apply adequate functions such as sinusoidal and parabola in order to reduce these differential equations. Therefore we can meet with good results through a series of above process. As a remarkable result, CIP recommendations (2002) give inadequate solution with over 10% error. However it gives very good solution if parts of our study are reflected at the said recommendations. The fact means that CIP recommendations (2002) well-known as international standard of stay cables are not even concern about this subject yet. For verification of this study, F.E. analysis using E.C.C. with external forces was fulfilled, and the accuracy and conciseness of this study were shown.

Design to Control Vibration for Stay Cable with Damper (댐퍼도입에 의한 사장 케이블의 제진설계)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae;Seo, Ju Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1A
    • /
    • pp.51-58
    • /
    • 2008
  • A cable element happens to vibration easily rather than other elements because a cable element has few rotational stiffness. Dynamic motion of stay cable is distinguished from vibration by wind and/or rain and excitation by support movement. Mostly a stay cable is vibrated by wind and/or rain except that when natural periods coincide between stiffening girder and stay cable. It happens to deterioration of serviceability and durability by vortex shedding, rainy-wind induced vibration, and galloping. Additional damping generated by installation of cable damper is well known good scheme against above phenomena. Researchers have lack of effort to develop the recommendations even if cable stayed bridges are designed and constructed in Korea. Therefore, development of the domestic recommendations should be achieved as soon as possible. This study suggests the consistent and systematic recommendations on vibration controlling design of stay cable by installation of damper. It gives readers two important methodologies that one evaluates required damping ratio, the other determines installing point considering efficiency.

현장취재 - 김포, 강화지역 2세 양계인을 찾아서 - '풍우동주(風雨同舟)' 한 배를 타고 가다

  • Kim, Dong-Jin
    • KOREAN POULTRY JOURNAL
    • /
    • v.43 no.7
    • /
    • pp.108-110
    • /
    • 2011
  • 국내 양계산업은 초창기인 1960-70년대를 시작으로 비약적인 발전을 해 오고 있다. 많은 농가들이 자동화, 규모화를 이루면서 농가수는 점점 줄어드는 추세를 보이고 있다. 이런 시대적인 흐름 속에 양계업도 자연스럽게 2세에게 경영권이 넘어가는 현상이 두드러지게 나타나고 있다. 본고는 경기도 김포를 중심으로 모인 젊은 패기의 양계 2세들이 진취적이고 적극적으로 양계업을 꾸려나가고 있는 현장을 찾아 활동상황을 취재한 것이다.

전력계통안정화 보호계전기술

  • 신대승
    • 전기의세계
    • /
    • v.43 no.4
    • /
    • pp.20-26
    • /
    • 1994
  • 전력계통은, 발전기, 변압기, 모선, 선로등을 주요소로 한 많은 설비요소로 구성되며, 이들이 일체로 되어 하나의 안정상태를 유지하면서 운용되고 있다. 전력계통 구성요소중, 특히 가공선로는 지역적으로 널리 분포되어 있으므로, 뢰, 풍우, 염분 등 자연 현상의 영향을 받아 단락, 지락등 계통사고 발생이 불가피하며, 또 다른 구성요소들도 각각 고유한 사고형태와 사고빈도를 가지고 있다. 보호방식은 이들 각종 설비에 사고가 발생하였을 때에, 신속히 사고설비를 계통에서 제거하여, 사고 전류의 계속으로 인한 설비손상을 방지하는 것을 그 기본목표의 하나로 하고 잇다. 그러나 사고발생은 단지 설비의 손상을 가져올 뿐만 아니라, 하나의 안정상태를 유지하고 운용되고 있는 전력계통 전체에 대해서, 이 안정을 무너뜨리는 방아쇠로 작용하며, 사고의 계속, 또는 사고제거에 따른 계통구성의 급변등은 주파수의 저하, 계통탈조, 설비과부하등으로 파급되어 전계통 붕괴로 확대될 가능성을 가지고 있다. 이러한 경향은 전원의 원격화와 집중대용량화, 선로조류의 증가등으로, 계통이 복잡화함에 따라 더 증대하고 있다. 이러한 배경을 바탕으로 하여 보호방식의 책무는, 종전의 설비보호 위주에서 사고파급방지에 의한 계통보호(protection for power system disturbance)로 그 중점목적이 옮겨가고 있으며, 이 사고 파급방지보호장치를 계통안정화장치라고도 한다.

  • PDF