• Title/Summary/Keyword: 풍속저감

Search Result 80, Processing Time 0.03 seconds

Analysis and Management Strategies of the Cold Air Characteristics in Hannamgeumbuk-Jeongmaek and Geumbuk-Jeongmaek (한남금북·금북정맥 일대의 찬공기 특성 분석을 통한 청주시 찬공기 관리방안)

  • SON, Jeong-Min;EUM, Jeong-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.152-171
    • /
    • 2019
  • In this study, we analyzed the characteristics of the cold air generated in Hannamgeumbuk and Geumbuk-Jeongmaek and proposed their management strategies. We also suggested management strategies after analyzing detailed cold airflows for Cheongju located Hannamgeumbuk-Jeongmaek and we compared the degree of nighttime temperature reduction of the Jeongmaek by using data obtained from observatories located on Cheongju. We used KALM(Kaltluftabflussmodell), a cold air simulation model developed in Germanay and identified both cold airflows and altitude of cold air layers generated during 360minutes at night. As a result, the cold airflow generated in the Jeongmaek became strong and the cold air was appeared clearly in the western part of the Hannamgeumbuk-Jeongamek and in the northern part of the Geumbuk-Jeongmaek. The average velocity of cold airflow was recorded at 0.45m/s, and the maximum speed of cold airflow was recorded at 2.70m/s. The average height of the cold air layer was 104.27m/s and the maximum thickness was 255.0m. The average velocity of cold airflows in Cheongju was 0.51m/s and the average height of cold air layer was 48.87m high. The highest degree of nighttime temperature reduction appeared in the Cheongnamdae observatory($-3.8^{\circ}C$), where the altitude of the cold air layer is high. The results showed that cooling effect of Jeongmaek actually affected the temperature reduction during nighttime. Based on the results, we designated the main mountain area of the Jeongmaek with active cold air generation as "cold air conservation areas" and proposed the current forest and topography conservation. We also proposed to designate areas that facilitate the cold airflows as "cold air management areas" and to complement the function of Jeongmaek. This study could support the establishment of systematic management plans of the Jeongmaek. In addition, it is expected that the results can be applied as basic data for ventilation paths of Cheongju.

A Study on the Inflow Velocity Reduction Measures in Case of Fire Great Depth Underground Double-Deck Tunnel (대심도 복층터널 화재 시 유입풍속 저감방안 연구)

  • Yang, Yong-Won;Moon, Jung-Joo;Shin, Tae-Gyun
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Recently, frequent traffic congestion has occurred in domestic urban roads. As a solution for downtown traffic congestion in domestic urban roads, plans for great depth underground double-deck tunnels have been made. Great depth underground double-deck tunnels that have been planned for passenger cars, has the structure of a network type; the entry of vehicles is carried out in the underground space. In these network great depth underground double-deck tunnels, the cross section and the height of the tunnel are smaller than the general road tunnel, and the smoke of a fire will propagate faster than the evacuation of tunnel passengers by the action of the traffic-ventilation and casualties are expected. Therefore, in the present study, an attempt was made to prevent the delay system for fire smoke diffusion at the time of a fire in a domestic network great depth underground double-deck tunnel according to the area of the tunnel block during the operation of the delay system for fire smoke diffusion to analyze the effects of reducing the inflow velocity. When the area of the tunnel block was not less than 50%, the effect of reducing about 21% of the wind speed acting on the tunnel was significant. If the area is more than 50%, the diffusion rate of fire smoke was reduced by approximately 21%, which will be useful for a safe evacuation.

Flux Profile Method for Evaluating the thermal Efficiency of Green roof (Flux Profile Method를 적용한 옥상녹화의 열효율 성능 평가)

  • Kwon, You Jeong;Seo, YongWon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.320-320
    • /
    • 2022
  • 기후변화와 도시화로 인한 영향으로 도시의 폭우, 폭염을 비롯한 현상이 빈번하게 발생하고 있다. 특히 시가화 지역의 높은 불투수율은 도시홍수를 야기한다. 이러한 현상을 완화하기 위해 도시지역에서는 그린인프라와 저영향개발이 도입되고 있다. 그 중 지속가능한 발전을 위한 필수요소로 자리매김한 옥상녹화는 도시에 위치한 건물의 상층부와 내부의 온도를 낮춤으로써 에너지절감효과와 강우 시 빗물을 저류함으로써 우수유출 저감효과, 그리고 도시 공간 내 녹지도입으로 인한 이산화탄소 배출 저감 효과 등을 기대할 수 있다. 본 연구에서는 열섬현상완화와 유출 저감의 방안 중 하나인 옥상녹화(Green roof)의 효과를 정량적으로 평가하기 위해 콘크리트로 이루어진 동일한 제원의 실험동을 구축하고, 실험동 내외부의 온도, 습도, 강우, 풍속, 일사량 등의 기상자료를 측정할 수 있는 센서를 설치하였다. 각 실험동에서 측정된 기상요소를 Flux Profile Method를 적용하여 공간 내에 있는 열에너지의 총량인 순복사열을 구성하는 현열속, 잠열속, 토양열속(H, LE, G)을 산정하였다. 또한 에너지 평형에 따라 산정된 각 실험동의 열속과 지표면 복사량 관측자료을 정량적으로 비교하여 옥상녹화의 적용성을 평가하였다. 2021년 7월 21일부터 2021년 7월 28일 까지 모니터링한 결과 옥상녹화의 열 효율은 일반 콘크리트 지붕에 비해 실내온도가 최대 6.83℃ 낮게 나타나며 이는 여름철 건물 내부의 온도조절에 필요한 에너지 저감효과를 볼 수 있다. Flux Profile Method를 적용한 결과 옥상녹화의 전체 열속 중 현열속 28.5% 잠열속 70.7%, 토양열속 0.5% 의 복사량 분포를 보였고, 일반 콘크리트 지붕은 현열속 45.3%, 잠열속 38.6%, 토양열속 16.2% 으로 나타났다. 이와 같은 방법은 옥상녹화의 정량적 평가를 가능하게 함으로서 향후 기후변화 대응방안 및 전략 수립 시 옥상녹화의 온도저감효과 분석에 적극 활용할 수 있을 것으로 판단된다.

  • PDF

Application of Flux Profile Method for Evaluating the Temperature Decreasing Effects of Green roof (여름철 옥상녹화의 온도저감효과 평가를 위한 Flux Profile Method의 적용)

  • Kwon, You Jeong;Seo, YongWon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.94-94
    • /
    • 2021
  • 현재 전 지구적으로 일어나고 있는 극단적 기후현상과 이로 인한 자연재해의 원인은 복합적이다. 기후변화로 인한 영향과 동시에 도시화 또한 하나의 원인으로 작용하고 있다. 이러한 영향을 완화하기 위한 방안으로 도시의 그린인프라와 저영향개발은 최근 지속가능한 발전을 위해 꼭 필요한 요소로 자리잡고 있다. 그린인프라 유형 중 하나인 옥상녹화는 많은 이점을 제공한다. 도시에 위치한 건물의 상층부, 내부 및 주변 온도을 낮춤으로써 얻을 수 있는 에너지절감 효과와 강우 시 상당량의 빗물을 저류함으로써 기대되는 우수유출 저감효과, 그리고 도시 공간 내 식물의 적극적인 도입으로 인한 이산화탄소 배출 저감 효과 등을 기대할 수 있다. 본 연구에서는 도시지역의 열섬현상완화와 유출저감의 방안 중 하나인 옥상녹화(Green roof)의 효과를 정량적으로 평가하기 위해 콘크리트로 이루어진 동일한 제원의 실험동을 구축하고, 실험동 내외부의 연직방향 온도, 습도, 강우, 풍속, 일사량 등의 기상자료를 측정할 수 있는 센서를 설치하였다. 각 실험동에서 측정된 기상자료를 Flux Profile Method를 적용하여 무강우기간과 강우발생기간 동안의 연직 방향의 현열속, 잠열속, 토양열속(H, LE, G) 을 산정하였다. 에너지 평형에 따라 산정된 각 실험동의 열속과 지표면 복사량 관측자료을 정량적으로 비교하여 적용성을 평가하였다. 실험의 대조군인 일반 코팅재로 마감된 콘크리트 지붕의 무강우 기간 중 최대 현열속 693.82 W/m2 잠열속은 330.15 W/m2 으로 나타났으며, 실험군인 옥상녹화가 조성된 지붕의 최대 현열속 436.27 W/m2, 잠열속 949.20 W/m2 으로 나타났으며, 산정치와 관측치 시계열의 NSE는 0.81 으로 Flux Profile Method를 통해 산정된 열속의 정확도는 비교적 높은 것으로 나타났다. 이와 같은 방법으로 옥상녹화의 정량적 평가가 가능해짐으로써 향후 기후변화 대응방안 및 전략 수립 시 옥상녹화의 온도저감효과 분석에 적극 활용할 수 있을 것으로 판단된다.

  • PDF

Estimation of Standard Load for Disaster-Resistant Design of Outdoor Signboards (내재해형 옥외광고물 설계를 위한 표준하중 산정)

  • Lee, Sungsu;Kim, Junyeong;Ham, Hee Jung;Kim, Ji Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.131-140
    • /
    • 2016
  • Recent destructions of outdoor signboards have frequently been caused by strong wind, resulting in damage on the property and human livelihood. One of the major causes of the problems is inadequate implementation of structural design code to the outdoor signboards which are vulnerable to wind. This leads to this paper to present the design guideline of wind-resistant outdoor signboards. In order to estimate the design wind speed, basic wind speeds over Korea suggested by KBC(2015)(revision) are corrected with land surface roughness and topography of the terrain and installation height of the signboard. This paper also suggested the procedure of wind load estimation for different types of outdoor signboards; wall attached type, wall ribbed type and ground erected type. Since the process involves complex calculation to some extent, this paper presents summarized version of wind load estimation from non-professional point of view.

Modeling and Analysis of Control Scheme for Voltage Source Inverter Based Grid-connection of Wind Turbine (전압원인버터를 이용한 계통연계형 풍력발전의 출력제어 모의 및 해석)

  • 김슬기;김응상
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.154-163
    • /
    • 2003
  • Grid connection essentially requires a wind energy conversion system (WECS) to not only supply adequate power responding to constantly varying wind speed but also provide a specified level of voltage magnitude and frequency that is acceptable in the electric power network. To satisfy such requirements, appropriate control schemes of a wind turbine to be connected to the power grid should be employed. This paper presents an output control strategy of a grid-connected wind power generation, which consists of a fixed-pitch wind turbine, a synchronous generator and a AC-DC-AC component with a voltage source inverter built in, and performs modelling and analysis of the strategy using PSCAD/EMTDC, an electromagnetic transient analysis software. Real power output control of the voltage source inverter is implemented to extract the maximum energy from wind speed inputted through wind blades and reactive power control, to keep the terminal voltage of WECS at a specific level. SPWM switching method is used to reduce the harmonics and maintain 60 ㎐ of the output frequency. The wind turbine performance and output corresponding to wind variation and the terminal load change is simulated and analysed.

A Study on General Characteristics of Wind and Solar Power System, Automatic Tail Safety Controller and DC-DC Converter (풍력 및 태양광 발전시스템의 일반 특성과 강풍제어기 및 DC-DC컨버터에 대한 연구)

  • Choi, Jung-Hoon;Park, Sung-Jun;Moon, Chae-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.109-116
    • /
    • 2005
  • Wind power and photovoltaic(PV) systems are getting into the spotlight as substitute energy. But problem is happened stability by speed change of wind and the power output of the sun's ray. The power output amount according to velocity of wind power system. System breakdown can happen at change of sudden velocity, typhoon and night. This paper shows a automatic tail safety brake controller based on feedback control using wind velocity. The operation of automatic tail safety controller verified by manual test. PV system is a energy change system by temperature of sun's ray and cell. Maximum power point tracking(MPPT) is used in PV systems to maximize the photovoltaic array output power. In existed PV system is low output and changeable DC voltage for boost and filtering the buck-boost converter use. But, this paper established deformed DC-DC converter. Changed Buck-boost converter's unlined output current to line output current using DC-DC converter. This is effect that reduce ripple of output current. Proved through an output waveform comparison experiment. Finally, tail safety brake controller is established to wind turbine system for stability elevation and DC-DC converter is established on PV system for stability output.

Analysis of Temperature Influence Experiment on Green Spaces in Campus (캠퍼스 내 녹지공간의 온도분석 및 온도영향요인 규명 실험)

  • Kim, Jaekyoung;Kim, Wonhee;Kim, Eunil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.511-520
    • /
    • 2020
  • Owing to global warming, heat waves have become stronger in the summer, and research on improving the thermal environment of green spaces, such as urban parks, is being conducted. On the other hand, studies on improving the urban thermal environment, which is changing due to the greening pattern and the intensity of the wind, are still insufficient. This study analyzed the temperature of the green spaces on campus to understand the factors affecting the temperature changes. After investigating the covering condition and planting form of the site, factors, such as temperature, humidity, wind direction, wind speed, and illuminance, were measured. The most influential factors on the temperature distribution are evapotranspiration and wind - induced heat transfer. The other major factors affecting the temperature change were the type of cover, wind velocity/wind direction, type of planting, shade / solar irradiance. In the type of cover, the plant was classified as low temperature, and the asphalt pavement was classified as high temperature. In wind speed, instantaneous temperature was reduced by 1.2 ℃ in southern wind, 0.7 ℃ in the westerly wind, 0.4 ℃ in the north wind and 0.5 ℃ in the east wind when a wind of 3.5m/s or more was blown.

Performance Evaluation of Measuring Instrument for Infra-Red Signature Suppression System Model Test (적외선 신호저감 장치 모형시험을 위한 계측기의 성능평가)

  • SeokTae Yoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.6
    • /
    • pp.21-27
    • /
    • 2023
  • Modern naval ships install an Infra-Red Signature Suppression system (IRSS) in their exhaust pipe to reduce infrared signature emitted to the outside. In addition, naval ships are strategic assets with a very long life cycle, so high reliability of the performance of the equipment on board must be guaranteed. Therefore, equipment such as IRSS is evaluated for performance through model testing at the design stage. A variety of measuring instruments are used in IRSS model testing, and the reliability of these instruments must also be guaranteed. In this paper, a study was conducted to evaluate the reliability of measurement equipment used in IRSS model testing. The test equipment and instruments used were a hot gas wind tunnel, pitot tube, digital differential pressure gauge, thermocouple sensor, and digital recorder. As the fan speed of the hot gas wind tunnel increased, the measurement deviation of the flow decreased, and the temperature output of the thermocouple sensor showed differences in response time and stability depending on the method used.

The structural performance estimation and assessment of noise barrier by wind pressure (풍압에 의한 방음벽의 구조성능 산정 및 평가)

  • 윤제원;박진일;권형오;김영찬;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.150-154
    • /
    • 2001
  • 도로 및 철도에서 발생하는 소음을 저감시키기 위해 설치되는 방음벽은 흡음률, 투과손실 등과 같은 음향성능 외에도 태풍과 같은 강풍에 견딜 수 잇는 구조성능이 확보되어야 한다. 따라서, 본 논문에서는 지역별 특성 및 풍속을 고려한 풍압을 산정하는 방법을 소개하고, 풍압에 의한 방음판의 구조해석을 수행하였다. 또한, EN 1794-1의 규정에서 정하는 시험방법에 따른 방음판의 하중변형량 시험을 통하여 방음판의 구조성능을 평가하였다.

  • PDF