• Title/Summary/Keyword: 풍선 확장술

Search Result 49, Processing Time 0.029 seconds

One-stage Repair of Aortic Arch Anomalies and Intracardiac Defects through Median Sternotomy (정중 흉골절개를 통한 대동맥궁 기형과 심기형의 일차교정술)

  • Chang Yun Hee;Lee Sang Kwon;Lee Hyung Doo;Kim Siho;Yie Kilsoo;Woo Jong Soo;Lee Young Seok;Sung Si Chan
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.291-300
    • /
    • 2005
  • One-stage repair of aortic arch anomalies and intracardiac defects through median sternotomy has been recently adopted by many institutions since it is known to be safer than the staged repair. The early and midterm results of the one-stage repair of aortic arch anomalies and intracardiac defects were retrospectively evaluated. Material and Method: 45 patients who underwent one-stage repair of aortic arch anomalies and intracardiac defects performed by one surgeon from January 1996 to July 2003 were included in this retrospective study. The median age of repair was 16 days (range, 3 days$\~$23.7 months) and the mean weight was $3.62\;\pm\;1.30 kg$. Thirty one $(68.9\%)$ had coarctation and 14 $(31.1\%)$ had interrupted aortic arch. Associated intracardiac anomalies were VSD in 31 patients (VSD group), TGA or Taussig-Bing anomaly in 10 (TGA group), and others in 4 (ASD in 1, aortopulmonary window 1, truncus arteriosus 1, aortic and mitral stenoses 1, miscellaneous group). The arch obstruction was repaired with end-to-side anastomosis in 23 patients and end-to-end anastomosis in 22. Result: Overall postoperative hospital mortality was $22.2\%\;(10/45);\;16.1\%$ (5/31) in VSD group, $40\%$ (4/10) in TGA group, and$25\%$ (1/4) in miscellaneous group. There was no mortality in VSD group since 1998, and the mortality in TGA group has remarkably reduced since technical modification for coronary transfer was adopted $(75\%\;vs\;16.7\%)$. There was no postoperative seizure or other neurological complications. Postoperative aortic restenosis occurred in 5 patients $(5/35,\;14.3\%)$. Two patients underwent balloon aortoplasty with successful results. There was no reoperation. There was one late death caused by pneumonia 5 months after the operation. Two-year actuarial survival rate including operative death was $72.9\%$. Conclusion: The operative mortality of one-stage repair has been reduced with time and aortic restenosis rate was also acceptable. We concluded that this procedure is a reproducible procedure for aortic arch anomalies associated with intracardiac defects.

Experience with a Safe Anastomotic Method for Ivor Lewis Operation (Ivor Lewis 수술 후 발생되는 문합 부위 합병증을 예방하기 위한 술식 평가)

  • Kim, Jeong-Won;Lee, Yong-Jik;Chang, Yong-Jin;Park, Chang-Ryul;Jung, Jong-Pil
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.625-629
    • /
    • 2008
  • Background: When it comes to esophageal cancer operations, the prevalence of anastomotic complications that adversely affect quality of life is related to the type of anastomotic procedure and the operative site. We studied outcomes related to a safe anastomotic method used in Ivor Lewis esophagogastrectomy for preventing anastomotic leakage and stricture formation. Material and Method: Between May 2003 and April 2007, 18 patients with esophageal cancer underwent this type of esophagogastrectomy. Four people were lost to follow-up. There were 17 men (94.4%) and 1 woman. The mean patient age was 61 years (range, $46{\sim}73$ years). Result: The mean follow-up period was 17.2 months (range, $1{\sim}45$ months). There was no anastomotic leakage. There was one benign anastomotic stricture (5.6%) requiring esophageal balloon dilatation, which was accomplished with a 25 mm circular stapler. Conclusion: We experienced relatively good postoperative results using a safe anastomotic method in the Ivor lewis operation for preventing anastomotic complications. These results suggest that this anastomotic method is effective in reducing the incidence of benign anastomotic complications.

Clinical Outcomes and Prognosis of Patients with Stent Fracture after Successful Drug-Eluting Stent Implantation (관상동맥 약물 방출 스텐트 삽입 후 스텐트 골절에 대한 임상결과 및 예후)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.109-116
    • /
    • 2014
  • Many studies have suggested that in the era of Drug-Eluting Stents(DES) are one of the causes of In-Stent Restenosis(ISR) of Stent Fracture(SF). The present study sought to evaluate clinical characteristics of patients with stent fracture after successful DES implantation. The 4,701 patients were selected for analysis who underwent a follow-up coronary angiography irrespective of ischemic symptoms. The overall incidence of SF was 32 patients(male:female=19:13, Av. age $62.44{\pm}9.8$year, 0.68%). Fractures of Sirolimus-Eluting Stents(SES), Paclitaxel-Eluting Stents(PES), Biolimus A9-Eluting Stents(BES), Everolimus-Eluting Etents(EES), Endothelial Progenitor Cell Capture Stent(EPC) and Zotarolimus-Eluting Stents(ZES) are accounted for 19(59.4%), 9(28.1%), 2(6.3%), 1(3.1%), 1(3.1%) and 0(0%) respectively. SF developed in the left Anterior Dscending(LAD) artery in 16 patients(50%) and in complex(type B2, C) lesions in 25 patients(69.4%). Ten patients were treated with heterogenous DES, the rest being treated with either homogenous DES(3 patients), plain old balloon angioplasty(3 patients), or conservative medical treatment(17 patients). None of the patients with SF suffered from cardiac death during a follow-up period of $32.9{\pm}12.4$ months. The overall rate of DES fracture over up to 3.7 years of follow-up was 0.68% with higher incidence in SES than in PES. SF frequently occurred in the LAD artery and in complex lesions. Of the patients with SF, coronary intervention was performed only when the binary restenosis lesion was significant. During the follow-up, patients with SF have continued on combination antiplatelet therapy. There is a very low rate of major adverse cardiac events(post-detection of SF), especially cardiac death associated with SF.

May-Thurner Syndrome Treated with Endovascular Wall Stent - Report of two cases - (May-Thurner 증후군의 혈관 내 스텐트를 이용한 치료 - 치험 2예 -)

  • Yoon, You-Sang;Won, Je-Hwan;Choi, Ho;Soh, Dong-Mun;Lee, Cheol-Joo;Kim, Hyung-Tae
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.202-205
    • /
    • 2003
  • Deep vein thrombosis (DVT) is a common disease. However, May-Thurner syndrome, which is the cause of DVT, is an uncommon processes in which there is an impaired venous return due to compression of the left iliac vein by the overlying right common artery. This condition results in a left iliofemoral deep thrombosis and severe leg edema. It is, therefore, called iliac compression syndrome. Catheter-directed thrombolytic therapy of acute extensive iliofemoral DVT and balloon angioplasty with venous stenting are recommended. Two cases with history of left leg swelling are diagnosed as May-Thurner syndrome, which was demonstrated by venography. We successfully treated the patients with thrombolysis, balloon angioplasty, and stent insertion at the site of common iliac vein compression. Therefore, we report the cases with overall review of the literature.

Neck Clipping of Giant Aneurysm in ICA Using Intra-Operative Temporary Balloon Occlusion and Suction Decompression Technique - A Case Report - (술중 풍선 확장을 이용한 일시적 근위부 결찰과 흡입, 감압술을 실시한 내경동맥의 거대동맥류 결찰 - 증례보고 -)

  • Weon, Keun Soo;Shin, Yong Sam;Park, Han Jun;Lee, Seung Un;Yun, Su Han;Cho, Ki Hong;Cho, Kyung Gi
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.165-169
    • /
    • 2001
  • Apatient, 51 years old woman, had suffered form headache and decrease of visual acuity. She had $3{\times}3cm$ sized giant aneurysm originated in cavernous and clinoid portion of left ICA(C4,C5) in the cerebral angiography. Before craniotomy, left CCA was exposed and 6F double lumen catheter was inserted in left ICA through the sheath. Pre-operative angiography was done. balloon catheter was positioned at the petrous portion of ICA. Eyebrow approach was done and giant aneurysm was exposed. The proximal blood flow was controlled with balloon dilatation and suction and decompression was tried, then multiple clips were applied. The loss of distal blood flow under intra-operative angiography was notified after clipping. The position of clips were repositioned to preserve blood flow & the rich flow was confirmed at distal part of clipping. In the post-operative cerebral angiography, the same finding was shown.

  • PDF

Determination of Practical Dosing of Warfarin in Korean Outpatients with Mechanical Heart Valves (인공심장판막 치환환자의 Warfarin 용량결정)

  • Lee Ju Yeun;Jeong Young Mi;Lee Myung Koo;Kim Ki-bong;Ahn Hyuk;Lee Byung Koo
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.761-772
    • /
    • 2005
  • Background: Following the implantation of heart valve prostheses, it is important to maintain therapeutic INR to reduce the risk of thromboembolism. The objective of this study was to suggest a practical dosing guideline for Korean outpatients with prosthetic heart valves managed by a pharmacist-run anticoagulation service (ACS). Material and Method: A retrospective chart review was completed for all patients enrolled in the ACS at Seoul National University Hospital from March, 1997 to September, 2000. Patients who were at least 6 months post-valve replacement and had nontherapeutic INR value (less than 2.0 or greater than 3.0) were included. The data on 688 patients (1,782 visits) requiring dosing adjustment without any known drug or food interaction with warfarin were analyzed. The amount of adjusted dose and INR changes based on the INR at the time of the event were calculated. Aortic valve replacements (AVR) patients and mitral or double valve replacement (MVR/DVR) patients were evaluated separately. Result: Two methods for the warfarin dosage adjustment were suggested: Guideline I (mg-based total weekly dose (TWD) adjustment), Guideline II (percentage-based TWD adjustment). The effectiveness of Guideline 1 was superior to Guideline II overall in patients with both AVR and MVR/DVR. Conclusion: The guideline suggested in this study could be useful when the dosage adjustment of wafarin is necessary in outpatients with mechanical heart valves.

Aortocaval Fistula - A case report - (대동맥-대정맥루 -치험 1예-)

  • Cho Kwang-Hyun;Kwon Young-Min;Han Il-Yong;Jun Hee-Jae;Lee Yang-Haeng;Hwang Youn-Ho;Yoon Young-Chul
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.721-724
    • /
    • 2005
  • Aortocaval fistula is a rare complication of abdominal aortic aneurysm, involving less than $1\%$ of all abdominal aortic aneurysms. A 64-years old man with a long history of hypertension and abdominal aortic aneurysm had chest pain, dyspnea, epigastric discomfort and palpable abdominal pulsating mass. Physical examination revealed hypo­tension with a systolic blood pressure of 70 mmHg, a large pulsatile mass and a systolic abdominal bruit. Laboratory data revealed a hemoglobin values of 11.0 g/dL, blood urea nitrogen (BUN) value of 5 mg/dL, and creatine value of $2.5 mg\%$. Abdominal Angio CT showed a 10cm infrarenal abdominal aortic aneurysm with dilatation of the IVC and aortocaval fistula from the aortic aneurysm, which was confirmed at emergency surgery. When the aneurysm was opened and the thrombus was removed, a 1 cm communication was identified between the aorta and IVC. This was controlled with Foley catheters ballooning, and the fistula was closed by continuous suture placed outside the aneurysm. A bifurcated aorto-iliac graft was used to restore arterial continuity. The patient was discharged home after uncomplicated postoperative course.

Risk Assessment of Arsenic by Human Exposure of Contaminated Soil, Groundwater and Rice Grain (오염된 토양, 지하수 및 쌀의 인체노출에 따른 비소의 위해성 평가)

  • Lee Jin-Soo;Chon Hyo-Taek
    • Economic and Environmental Geology
    • /
    • v.38 no.5 s.174
    • /
    • pp.535-545
    • /
    • 2005
  • Environmental survey from some abandoned metal mine areas was undertaken on to assess the risk of adverse health effects on human exposure to arsenic influenced by past Au-Ag mining activities. Elevated levels of As were found in tailings from the studied mine areas. This high concentration may have a impact on soils and waters around the tailing piles. In order to perform the human risk assessment, chemical analysis data of soils, rice grains and waters fur As have been used. The HQ values fer As via the rice grain and groundwater consumption were significantly higher compared with other exposure pathways in all metal mine areas. However, there were minimal soil and water dermal contact risks. The resulting Hl values of As from the Dongil, Okdong and Hwacheon mine areas were higher than 5.0, and their toxic risk due to drinking water and rice grain was strong in these mine areas. The cancer risk of being exposed to As by the rice grain route from the Dongil, Okdong and Hwacheon mine areas was $5.2\times10^{-4},\;6.0\times10^{-4}\;and\;8.1\times10^{-4}$, respectively. The As cancer risk via the exposure pathway of drinking water from these mine areas exceeded the acceptable risk of 1 in 10,000 fer regulatory purposes. Thus, the daily intakes of groundwater and rice grain by the local residents from the Dongil, Okdong and Hwacheon mine areas can pose a potential health threat if exposed by long-term arsenic exposure.

Effects of Percutaneous Balloon Mitral Valvuloplasty on Static Lung Function and Exercise Performance (승모판협착증 환자에서 경피적 풍선확장판막성형술의 폐기능 및 운동부하 검사에 대한 효과)

  • Kim, Yong-Tae;Kim, Woo-Sung;Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Kim, Jae-Joong;Park, Seong-Wook;Park, Seung-Jung;Lee, Jong-Koo;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.1-10
    • /
    • 1994
  • Background: Patients with mitral stenosis(MS) have been demonstrated to have a variable degree of pulmonary dysfunction and exercise impairment. The hemodynamic changes of MS can be reversed after percutaneous mitral balloon valvuloplasty(PMV), but the extent and time course of the imporvement in pulmonary function and exercise capacity are not defined. Methods: In order to investigate the early(3 weeks or less)and late(3 months or more) effects of PMV on pulmonary function and determine if the pulmonary dysfunction is reversible even in patients with moderate to severe pulmonary hypertension, we performed the spirometry, measurements of diffusing capacity and lung volumes, and incremental exercise tests in patients with MS before and after PMV. Results: In 46 patients with MS(age: $40{\pm}12$years, male to female ratio: 1:2, mitral valve area: $0.8{\pm}0.2cm^2$) there was a significant increase in FVC(P<0.0025), $FEV_1$(P<0.001), $FEF_{25-75%}$(P<0.001, $FEF_{50%}$(P<0.001), PEF(P<0.0005), MVV(P<0.005), $\dot{V}O_2$max (P<0.0001), and AT(P<0.0001) after average 10 days of PMV. Also there was a significant decrease in DLco(P<0.0001) and DL/VA(P<0.0001). At later($5{\pm}2$months) follow-up in 11 patients, there was no further improvement in any parameters of pulmonary function and exercise test. Twenty nine patients with sinus rhythm were divided into 16 patients with pulmonary arterial pressure(PAP) more than 35mmHg and/or tricuspid regurgitation grade n or more(group A) and 13 patients with PAP less than 35mmHg(group B). Group A Patients had significantly lower FVC(P<0.001), $FEV_1$(P<0.001), DLco(P<0.05), $\dot{V}O_2$ max(P<0.025) and mitral valve area(P<0.025) than group B patients. Group A patients after PMV, showed significant increase in FVC(P<0.001), maximum $O_2$ pulse(P<0.00001) and $\dot{V}O_2$ max(P<0.00025). Both group showed an increase in AT(P<0.0001, P<0.005), but group A showed greater decrease in $\dot{V}E/\dot{V}O_2$ and $\dot{V}E/\dot{V}CO_2$ both at AT(P<0.001, P<0.001) and $\dot{V}O_2$ max(P<0.0001, P<0.0001) after PMV compared with group B. Conclusion: These data suggest that patients with MS can show increased pulmonary function and exercise performance within 1 month after PMV. Patients with moderate to severe pulmonary hypertension had a significant increase in exercise performance compared with those with mild to no pulmonary hypertension and it is thought to be related to a significat decrease of ventilation for a given oxygen consumption at maximum exercise.

  • PDF

Radiation Exposure of Operator in Intracoronary Radiotherapy Using $^{188}Re$ ($^{188}He$을 이용한 혈관내 방사선 치료시 시술자의 방사선 피폭 수준)

  • Chie, Eui-Kyu;Lee, Myung-Mook;Wu, Hong-Gyun
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.191-195
    • /
    • 2000
  • This study was undertaken to estimate the exposed dose of the medical personnel during the intracoronary radiotherapy procedure as a part of ongoing SPARE (Seoul National University Hospital Post-Angioplasty Rhenium) trial. Data of thirty-four patients among forty-two irradiated patients participating in this trial due to coronary artery stenosis were retrospectively analyzed. Intracoronary radiotherapy was delivered to the patient immediately after angioplasty ballooning. Prescribed dose was 17 Gy to media of the diseased artery and was delivered with $^{188}Re$ filled balloon catheter. Dosimetry was carried out with GM counter at eight different points. Ten centimeter and forty centimeter from the patient's heart were selected to represent maximum and whole-body exposed dose of the operator, respectively. Median delivered dose was 111.6 mCi with average treatment time of 576 seconds. Average exposed dose rate at 10 cm and 40 cm from the patient's heart were 0.43 mSv/hr and 0.30 mSv/hr, respectively. Average exposed doses per treatment were 0.07 mSv and 0.05 mSv for 10 cm and 40 cm from the patient's heart, respectively. Exposed doses measured are much lower than recommended limit of 50 mSv for radiation workers or 1 mSv for general population in ICRP-60. This study proves that current method of intracoronary radiotherapy incorporated in this trial is very safe regarding radiation protection.

  • PDF