• Title/Summary/Keyword: 풀림 처리

Search Result 30, Processing Time 0.021 seconds

Effect of Heat Treatments on Welding Residual Stresses of AISI 4130 Steel (AISI 4130강의 용접잔류응력에 미치는 열처리의 영향)

  • 양영수;나석주;김원훈;조원만
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1982-1989
    • /
    • 1991
  • The effect of heat treatments were considered on the residual stress fields of AISI 4130 weldments. In experiments, various heat treatments such as preheating, postheating, stress relieve annealing and hardening treatment were carried out for the GTA weldments and the residual stress was measured by using the hole drilling method. The post weld heat treatment at 230.deg.C, which aimed mainly to prevent the possible weld cracking, was found to have only a negligible effect on the welding residual stress distribution, while the annealing treatment at 600.deg.C almost completely removes the residual stress. It was also revealed that the hardening treatment causes no further residual stresses in weldments.

Influence of the Dental Implant Abutment Screw Coating Materials on Joint Stability (임플란트 지대주나사 코팅이 결합안정성에 미치는 영향)

  • Lim, Hyun-Pil;Park, Young-Sun;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Yoon, Suk-ja
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.157-169
    • /
    • 2009
  • The aim of this study was to evaluate effect of implant abutment screw coating treatment on joint stability, investigating mechanical properties of these. For this study used $ExFeel^{(R)}$ external hexed implant system and $15mm{\times}1mm$ discs. Experimental group was $1{\mu}m$ TiN, TiCN, TiC coated abutment screws and discs. To know mechanical property, i evaluated adhesion strength, surface hardness, using disc, corrosion test using screw. The results were as follows : rotation angle of coated screws increased than that of non-coated screw because of lower friction coefficient, especially TiC coated screw group had the largest value, but removal torque decreased in all coated screws (p<0.05). Torque loss before and after fatigue test was the smallest in TiC-coated screws, and the largest in non-coated screws (p<0.05), and there was no statistically significant difference between dry condition and wet condition of screws because of higher surface hardness and lower friction coefficient. From the above results, TiN, TiCN, TiC coating group had high abrasion resistance, especially TiC coated group which had low torque-consuming, high rotation angle as low friction coefficient will be considered to influence on implant abutment screw joint stability positively.

THE INFLUENCE OF ABUTMENT SCREW TIGHTENING TIMING AND DLC COATING OF CONICAL CONNECTION IMPLANT SYSTEM (일체형 지대주의 Diamond Like Carbon 표면 처리와 나사 조임 시기가 풀림 현상에 미치는 영향)

  • Kim, Ki-Hong;Koak, Jai-Young;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.209-216
    • /
    • 2008
  • Statement of problem: It is difficult about assessing the loosening tendency of conical connection type implant after cyclic loading with diamond like carbon coating one-piece abutments, and also about the retightening effect. Purpose: This study was performed to investigate the influence of one-piece abutment screw retightening after $5.0{\times}10^{4}$ cyclic loading and Diamond like coating Material and methods: Thirty two ITI implant were divided to 4 groups. Group 1,3-titanium abutment, group 2,4 - diamond like carbon coated abutment. Group 1,2 - $20.0{\times}10^{4}$ cyclic loading after $5.0{\times}10^{4}$ cyclic loading, Group 3,4- after $20.0{\times}10^{4}$ Cyclic loading. After cyclic loading, periotest values were taken and removal torque values of abutments were measured with a digital torque gauge. Results: 1. The removal torque of group 2 after $5.0{\times}10^{4}$ cyclic loading is slightly greater than the other groups but not significantly higher than others (P>0.05). 2. The final removal torque values after $20.0{\times}10^{4}$ cyclic loading of group 1 is bigger than group 3, and group 2 is bigger than group 4, but not significantly higher (P>0.05). 3. The final removal torque values after $20.0{\times}10^{4}$ cyclic loading of all groups are not significantly different (P>0.05).

Real-time Health Monitoring of Pipeline Structures (배관 구조물의 상시 건전성 모니터링)

  • Kim, Ju-Won;Kim, Tae-Heon;Lee, Chang-Gil;Park, Seung-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.666-669
    • /
    • 2010
  • 여러 가지 지하시설물 중 국가 주요 자원의 수송망을 책임지는 주요구조물인 수도관, 가스관등의 배관구조물은 접근이 쉽지 않은 지하공간에 복잡하게 연결되어 있어 그 중요성에 비해 유지, 관리, 보수가 쉽지 않았다. 이러한 배관구조물을 균열, 조인트 풀림 등의 손상으로부터 보다 안전하고 효율적으로 관리하기 위하여 상시적 배관구조물 손상진단기법을 연구하였다. 이를 위해 배관 구조물 시험체에 볼트풀림, notch 등과 같은 손상에 대하여 대표적인 압전센서인 PZT와 MFC를 부착하고 임피던스기법 및 유도 초음파기법을 적용하여 볼트풀림개수, notch 손상개수 증가에 따른 출력신호를 반복 계측하였다. 객관적인 평가를 위해 계측된 신호를 신호처리기법인 웨이블렛 변환을 수행하고, RMSD 및 1-CC의 손상지수를 사용하여 구조물손상을 정량화 시켰으며 이를 토대로 구조물의 건전성의 기준이 되는 임계값을 설정함으로서 임피던스와 유도초음파 두 검색기법을 이용한 상시적 배관구조물 건전성 모니터링의 가능성을 살펴보았다.

  • PDF

Comparison of removal torque between prefabricated and customized abutment screw (기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교)

  • Jamiyandorj, Otgonbold;Kim, Jee-Hwan;Kim, Mu-Seong;Park, Young-Bum;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.243-248
    • /
    • 2012
  • Purpose: The purpose of this study is to compare the removal torque between prefabricated and customized implant abutment screw. Materials and methods: Three types of implant system (Osstem, Astra, Zimmer) were used. For each system, prefabricated abutment screw (control group) and customized abutment screw (test group) were used to connect the fixture and the abutment (n = 6). Digital torque gauze was used to control the tightening torque and the screws were tightened under each manufacturer's recommendation. 10 minutes after the connection the same tightening torque was applied, and 5 minutes after the second connection, the removal torque was measured. This procedure was repeated 10 times. In the cyclic loading test, 10 minutes after the first connection to the 6 groups (n = 3), the same tightening torque was applied, and a total of 1,000,000 time loading was applied at 30 degree angle to long axis with 50 N load. Repeated measures of ANOVA test (${\alpha}$=.05) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque after cyclic loading. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). In the 10 time repetition test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Also in the cyclic loading test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Conclusion: Within the limitation of this study, there was no significant difference in the removal torque between the prefabricated abutment screw and customized abutment screws.

Effects of anaerobic sealing agents on preload maintenance of screw-retained implant prosthesis with surface of screws (임플란트 보철물 나사의 전하중 유지에 나사 표면에 따른 혐기성 나사 고정제의 효과)

  • Ryu, Seung-Beom;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.103-109
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the preload maintenance of the retaining screw when using anaerobic sealing agents in implant fixture and abutment components. Specifically, the study examines the effects of anaerobic sealing agents on different types of screws. Materials and methods: External hexagon implants made of titanium and anti-rotational abutments were used. Titanium abutment screws and ebony abutment screws from the same manufacturer were used. The experiment was divided into four groups (n = 10 in each group). In the control group, no sealing agent was used at the implant fixture and abutment screw interface. All abutment screws were tightened according to the manufacturer's recommended torque (30 N.cm). After 24 hours, the removal torque (detorque) of each screw was measured using a digital torque gauge device. The data were analyzed by two-way ANOVA test according to normality distribution satisfaction. Results: Looking at the results for each group, titanium screws and no treatment showed detorque values of 20.3 ± 1.6 N.cm. titanium screws and applied anaerobic sealing agent showed detorque values of 32.4 ± 6.7 N.cm. Ebony screws and no treatment showed detorque values of 20.2 ± 1.5 N.cm. ebony screws and applied anaerobic sealing agent showed detorque values of 30.4 ± 4.5 N.cm. Conclusion: The detorque value was higher in the case of using anaerobic sealing agents in both the titanium screw and ebony screw groups. But there was no difference between the two screws.

Effect of Nickel Content on Corrosion Resistance and Machinability of Fe-23Cr-2.5C-1.2Si-1.08Mn-0.48Mo-0.3V-xNi Cast Iron (Fe-23Cr-2.5C-1.2Si-1.08Mn-0.48Mo-0.3V-xNi 주철의 내식성 및 피삭성에 미치는 Ni의 영향)

  • Kim, Ki-Bin;Jung, Sung-Sik;Baek, Min-Sook;Yoon, Dong Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.576-584
    • /
    • 2020
  • The extruder screw material is mainly SKD11, but the recent development of synthetic resins have increased the occurrence of chemical corrosion and wear. To solve this issue, high chromium cast iron is needed because of its good abrasion resistance and corrosion resistance, but its use is avoided because of its poor machinability. In this study, to improve the machinability of high chrome cast iron, 0, 0.5, 1.0, 1.5% of nickel, which has excellent workability, was added to high chromium cast iron with a composition of Fe-23Cr-2.5C-1.2Si-1.08Mn-0.48Mo-0.3V, and annealed after casting. Subsequently, the effect of nickel on the machinability and corrosion resistance was analyzed using a turning test and coin polarization test, and compared with SKD11. After casting using a high-frequency vacuum induction furnace, the annealing treatment was performed at 750 ℃ for five hours and then reheated at 1100 ℃ for five hours. A turning test after annealing at 750 ℃ showed that the machinability was improved remarkably when the nickel content was over 1.0%. In the potentiodynamic polarization test in a 5% NaCl solution, the corrosion resistance decreased with increasing nickel content in the as-cast and annealing treatment. On the other hand, after reheating, the corrosion resistance was best with a 1.5% nickel content.

The effect of a titanium socket with a zirconia abutment on screw loosening after thermocycling in an internally connected implant: a preliminary study (내부연결 임플란트용 타이타늄 소켓을 이용한 지르코니아 지대주에서 열순환이 나사풀림에 미치는 영향: 예비연구)

  • Kyung, Kyu-Young;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.114-118
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the effects of a titanium component for the zirconia abutment in the internal connection implant system on screw loosening under thermocycling conditions. Materials and Methods: Internal connection titanium abutments and external connection zirconia abutments with titanium sockets were connected respectively to screw-shaped internal connection type titanium implants with 30 Ncm tightening. These implant-screw-abutment assemblies were divided into two groups of five specimens each; titanium abutments as control and zirconia abutments with titanium sockets as experimental group. The specimens were subjected to 2,000 thermocycles in water baths at $5^{\circ}C$ and $55^{\circ}C$, with 60 seconds of immersion at each temperature. The removal torque values (RTVs) of the abutment screws of the specimen were measured before and after thermocycling. RTVs pre- and post-thermocycling were investigated in statistics. Results: There was not screw loosening identified by tactile and visual inspection in any of the specimens during or after thermocycling. The mean RTV difference for the control group and the experimental group were $-1.34{\pm}2.53Ncm$ and $-1.26{\pm}2.06Ncm$, respectively. Statistical analysis using an independent t-test revealed that no significant differences were found in the mean RTV difference of the groups (P > 0.05). Conclusion: Within the limitations of this in vitro study, the titanium socket for the zirconia abutment did not show a significant effect on screw loosening under thermal stress compared to the titanium abutment in the internal connection implant.