• Title/Summary/Keyword: 표준 k-$\varepsilon $모델

Search Result 34, Processing Time 0.027 seconds

Pressure Loss in the Discharge Flow Path from a Diffuser to a wall (디퓨저에서 벽면으로의 방출유로에서의 압력손실)

  • Lee, J.;Kim, Y.I.;Kim, S.H.;Lee, D.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.517-522
    • /
    • 2001
  • The exit edges of a diffuser are smoothly rounded, and a wall is located perpendicularly to a diffuser exit. The fluid is discharged towards the radial direction of a diffuser after impinging against a wall from a diffuser. In this flow path, pressure loss coefficients have been calculated by the variables of Reynolds number at a diffuser inlet, distance between a diffuser exit and a wall, and turbulence models. As a result, it was calculated that $h/D_0$ ratio between $0.35\sim0.4$ has the minimum pressure loss coefficient regardless of Reynolds number and turbulence models. It was also found that in case of the flow with relatively high Reynolds number at a diffuser inlet, the pressure loss coefficients by RNG $k-\varepsilon$ model have a tendency to be near to those by standard $k-\varepsilon$ model at small ratio of $h/D_0$, but to those by RSM at large ratio.

  • PDF

Numerical Analysis on the Blade Tip Clearance Flow in the Axial Rotor (II) - Variation of Leakage Vortex with Tip Clearance and Attack Angle - (축류 회전차 익말단 틈새유동에 대한 수치해석(II) - 틈새변화 및 영각변화에 따른 누설와류의 변화 -)

  • Ro, Soo-Hyuk;Cho, Kang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1106-1112
    • /
    • 1999
  • Substantial losses behind axial flow rotor are generated by the wake, various vortices in the hub region and the tip leakage vortex in the tip region. Particularly, the leakage vortex formed near blade tip is one of the main causes of the reduction of performance, generation of noise and aerodynamic vibration in downstream. In this study, the three-dimensional flow fields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The numerical technique was based on SIMPLE algorithm using standard $k-{\varepsilon}$ model(WFM) and Launder & Sharma's Low Reynolds Number $k-{\varepsilon}$ model(LRN). Through calculations, the effects of tip clearance and attack angle on the 3-dimensional flow fileds behind a rotor and leakage flow/vortex were investigated. The presence of tip leakage vortex, loci of vortex center and its behavior behind the rotor for various tip clearances and attack angles was described well by calculation.

A study on the three dimensional turbulent flow analysis of wake flow behind rotating blade row between hub and midspan (허브와 중앙스팬 사이의 회전익 후류 3차원 난류유동해석에 관한 연구)

  • No, Su-Hyeok;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.911-918
    • /
    • 1997
  • The turbulent viscous wake flows behind a single airfoil, two-dimensional stationary blade row and three-dimensional rotating blade row were calculated, and the numerical results were compared with experimental ones. The numerical technique was based on the SIMPLE algorithm using three turbulent closure models, standard k-.epsilon. model(WFM), low Reynolds number k-.epsilon. model(LRN) and Reynolds stress model (RSM). In the case of a single airfoil, WFM, LRN and RSM presented fairly good velocity distributions in the wake compared with experimental data. In the case of the stationary blade row, LRN and RSM presented better results than WFM for wake velocity distribution, and especially LRN showed best results among these three turbulent models. In the case of the rotating blade row, WFM and LRN showed fairly good agreement with experimental data of the three-dimensional velocity component distributions in the range from hub to mid span region. LRN was also superior to WFM in accuracy of prediction for the wake velocity distribution as same with the cases of a airfoil and the stationary blade row.

Prediction of Unsteady Turbulent Flow over a Square Cylinder using Two-Equation Turbulence Models (2-방정식 난류모델을 이용한 정사각주 주위 비정상 난류 유동의 예측)

  • Lee Sangsan
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.31-36
    • /
    • 1995
  • 비유선형의 물체 주위의 유동은 정체유동, 경계층 박리 및 주기적 와열 생성 등의 복잡한 유동현상이 공존한다. 본 연구에서는 비교적 단순한 형상인 정사각주 주위의 비정상 난류 유동을 2-방정식 와점성 난류모델인 표준 $k-{\varepsilon}$ 모델과 RNG $k-{\varepsilon}$ 모델을 이용하여 예측할 수 있는지를 검증하였다. 정교하게 수행된 최근의 실험과 대와류모사(LES)의 결과를 검증을 위한 비교의 자료로 삼았다. 적절한 난류모델의 선정과 더불어 시간 정확도, 공간 정확도 및 대류항 처리법 등이 해석결과에 미치는 영향도 살펴보았다. 기존의 표준 $k-{\varepsilon}$모델은 정체점 부근에서 난류 운동에너지를 과도하게 생성하는 근본적인 문제점 때문에 실험 및 LES의 결과를 제대로 예측할 수 없었다. 난류운동에너지의 초과 예측에 따른 운동량의 과도한 혼합으로 인해, 항력계수 및 양력계수의 비정상성 뿐 아니라 평균 항력계수도 부정확하게 예측하였다. RNG $k-{\varepsilon}$ 모델을 사용한 경우에는 정체점 주위 유동현상의 예측이 상당히 향상되어 항력계수 및 양력계수의 평균치, 진폭 및 비정상성의 주기 등을 정확하게 예측하는 것이 가능하였다. 그러나 이 경우에도 예측의 정확도가 시간 증분과 격자의 크기 및 대류항 처리법등에 영향을 받으며, 특별히 대류항 처리법에 상당히 민감하게 변하는 것을 알 수 있었다. 향상된 유동예측은 RNG $k-{\varepsilon}$ 모델의 난류에너지 소산율 방정식의 개선된 항이 과도하게 생성된 난류에너지를 정체점 부근에서 제거하기 때문에 가능하다는 것을 알 수 있었다.의 20세 이하 골절 및 탈구가$30.3\%까지 감소하게되어 년도가 증가함에 따라 청장년 층에 비하여 소아골절 및 탈구가 전체적으로 감소하는 경향을 보였다. 스키골절의 부위별 발생빈도는 1990년 이전까지 하지골절 및 탈구가 많았으나 이후 점차 상지의 골절 탈구가 증가하였다 하지에서 가장 많은 골절은 경골 골절이었으며, 경골골절은 회전력에 의한 나선형골절이 $76.5\%로 가장 많았고 년도에 따른 변화는 보이지 않았다. 스키손상의 발생빈도는 초기에 비하여 점차 감소하는 경향을 보였으며, 손상의 특성도 부위별, 연령별로 다양한 변화를 나타내었다.해가능성을 가진 균이 상당수 검출되므로 원료의 수송, 김치의 제조 및 유통과정에서 병원균에 대한 오염방지에 유의하여야 할 것이다. 확인할 수 있었다. 이상의 결과에 의하면 고농도의 유기물이 함유된 음식물쓰레기는 Hybrid Anaerobic Reactor (HAR)를 이용하여 HRT 30일 정도에서 충분히 직접 혐기성처리가 가능하며, 이때 발생된 $CH_{4}$를 회수하여 이용하면 대체에너지원으로 활용 가치가 높은 것으로 판단된다./207), $99.2\%$(238/240), $98.5\%$(133/135) 및 $100\%$ (313)였다. 각각 두 개의 요골동맥과 우내흉동맥에서 부분협착이나 경쟁혈류가 관찰되었다. 결론: 동맥 도관만을 이용한 Off pump CABG를 시행하여 감염의 위험성을 증가시키지 않으면서 영구적인 신경학적 합병증을 일으키지 않았고 좋은 혈관 개존율을 보여주었다. 따라서 동맥 도관을 이용한 Off pump CABG는 관상동맥의 협착의 정도에 따라 효율적으로 시행

  • PDF

Effects of Radiation Heat Transfer on the Fire in an Atrium (아트리움 공간에서 화재발생시 복사열전달의 영향 분석)

  • Yoon, Kyung-Beom;Chang, Hee-Chul;Kim, Tae-Kuk
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.18-24
    • /
    • 2007
  • The purpose of this study is focussed on the numerical predictions of temperature distribution by radiation heat transfer in atrium fire using the field fire model and the CCRHT-3D code. This code uses standard $k-{\varepsilon}$ turbulent model with SIMPLE algorithm and weighted sum of gray gases model regrouping(WSGGM-RG). The WSGGM-RG calculates radiative properties on the reduced computational loads while reserving the accuracy. The numerical results show that lower temperature distributions on the wall and the top ceiling wall can be obtained by considering radiative heat transfer. The temperature on the top ceiling wall can be an important parameter in predicting the operating condition of the sprinkler head.

Frost Formation in a Straight Duct under Turbulent Flow (난류 유동 하에서 덕트 내의 착상)

  • Yang, Dong-Keun;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1114-1121
    • /
    • 2003
  • A mathematical model considering the air side and the frost layer is presented to predict the frost layer growth. The standard k-$\varepsilon$ model for the air flow and the diffusion and energy equations for the frost layer are employed. The numerical results are compared with experimental data to validate the present model, and agree well with experimental data within a maximum error of 10%. The present model predicts well the frost properties and heat and mass transfer with respect to the frosting time. The variation of total heat transfer strongly depends on the operating condition, and has a similar trend to that of the sensible heat transfer. The frost properties along the flow direction are also investigated.

Numerical study on in-cylinder flow of a reciprocating engine using a fractional step method (Fractional step method를 이용한 엔진내부유동의 수치해석)

  • Lee, Byoung-Seo;Kong, Ho-Jin;Lee, Joon-Sik;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.745-750
    • /
    • 2000
  • A numerical code which can simulate unsteady, incompressible and 3-dimensional flows in an engine cylinder has been developed. The governing equations based on the cylindrical coordinate are discretized by the finite volume method with staggered variable arrangements. A geometric conservation rule is also incorporated into the simulation code in order to deal with a moving boundary problem. For the unsteady simulation, a fractional step method is adopted. The law of wall is applied to the wall boundaries and standard $k-\;{\varepsilon}$ model is used to describe the in-cylinder turbulent flow. The model cylinder has one eccentric port, flat piston and flat cylinder-head. The comparisons with experimental data show fairly well qualitative agreement.

  • PDF

Numerical Simulation on the Heat and Smoke Flow Phenomena Due to the Fire in a Cyclodrome (경륜장 내부의 화재발생에 따른 열 및 연기 거동에 대한 수치적 연구)

  • 박원희;김태국;손봉세
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.13-19
    • /
    • 2003
  • In this paper, numerical calculations are conducted to predict the characteristics of the heat transfer and smoke propagation in a cydodrome. The gas flow velocity and temperature around the origin of the fire is obtained by using a plume model and the turbulent flow characteristics are considered by standard $textsc{k}$-$\varepsilon$ turbulent model. In this study, the transient thermal behavior can be used for designing fire detection of large rooms.

Development of a Model for Fluid Analysis of Water Jet Using Automatic Javan(Salted-dry Seaweeds) Dryer Machine (전자동 자반건조기 제작에 이용할 Water Jet의 유동해석 모델)

  • Kim, Ill-Soo;Park, Chang-Eun;Jeung, Young-Jae;Son, Joon-Sik;Nam, Ki-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.5
    • /
    • pp.53-58
    • /
    • 1998
  • This paper concentrates on the development of a computational design program to determine nozzle size in water jet, combing the numerical optimization technique with the flow analysis code. To achieve the above objective, a two-dimensional model was developed for investigating the fluid flow in water jet and calculating the velocity and pressure distributions. The mathematical formulation as a standard ${k}-\varepsilon$ model was solved employing a general thermo fluid-mechanics computer program, PHOENICS code, which is based on the Semi-Implicit Method Pressure Linked Equations(SIMPLE) algorithm. The developed code was applied to water jet design to determine the nozzle size, and investigated the effect of the change of nozzle location. Calculated results showed that the flow pattern is not changed as the change of nozzle location.

  • PDF

Experiment on water turbulent natural convection for safety improvement of nuclear power plant (원자력발전소 안전성 평가 향상을 위한 물 자연대류 검증 실험)

  • Kim, Donghyuk;Ryu, Nayoung;Kim, Man-Bae;Park, Chang-Yong;Kim, Jungwoo
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.46-50
    • /
    • 2016
  • The objective of the present study is to perform experiments for water filled cavity heated and cooled from the side at $Ra=8.5{\times}108$. This experiment can provide validation database of the standard k-${\varepsilon}$ turbulence model for single-phase turbulent natural convection which has been regarded as one of the important phenomena in nuclear safety. For the natural convection inside a cavity, temperature and velocity were obtained by thermometry and PIV (Particle Image Velocimetry) methods. These results would be used for validation of standard k-${\varepsilon}$ turbulence model.