• Title/Summary/Keyword: 표준 시편

Search Result 165, Processing Time 0.021 seconds

Evaluation of Notch Effect on the Dynamic Strain Aging Behavior of Carbon Steel Piping Material (탄소강 배관 재료의 DSA 거동에 미치는 노치 영향 평가)

  • Lee, Sa-Yong;Kim, Jin-Weon;Kim, Hong-Deok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.3
    • /
    • pp.275-282
    • /
    • 2012
  • In this study, tensile tests were performed using standard and notched-bar specimens under two different displacement rates and various temperatures, in order to investigate the effects of the stress and strain concentration at the notched section on the dynamic strain aging (DSA) behavior of carbon steel piping material. In addition, finite element simulations were conducted to evaluate quantitatively the stress and strain states for both types of specimen under uniaxial tensile loading. The results showed that serration and an increase in tensile strength, which are considered to be evidence of DSA in carbon steels, can be observed from tensile tests for notched-bar specimens. It was also found that the temperature region of DSA observed in the notched-bar specimens was higher than the DSA region observed in the standard tensile specimens tested under the same displacement rate. The results of finite element analysis showed that this behavior is associated with the high strain rate at the notched section, which is caused by the stress and strain concentration.

A Proposal of Round Specimen for the Determination of Crack Arrest Toughness (균열정지 인성치결정을 위한 원형시편의 제안)

  • 이억섭;김상철;송정일;이규철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1472-1478
    • /
    • 1991
  • 본 연구에서는 Rectangular Computer Tension(CT) 시편을 수정하여 만든 표준 시편인 MRL-CLWL시편(material research laboratorycrack line wedge loaded specimen )으로 균열정지 인성치를 결정하였다. 그리고 CT시편과 같은 효과를 갖는 Newman등 이 제안한 round compact tension(RCT)시편을 수정한 Round-CLWL 시편으로 균열정지인 성치를 결정하여 상호 비교평가하였다. Round-CLWL 시편은 시편제작시 round-bar를 절단하여 시편으로 가공할 수 있으므로 가공성이 좋으며 따라서 가공비가 적게 든다. 특히 균열 위치 및 방향을 임의로 선택하여 가공하기가 용이하므로 방향성이 있는 소 재의 균열정지 인성치를 결정하는 데 매우 편리한 시편이라 생각된다. 본 논문에서 는 Round-CLWL 시편으로 $K_{1a}$ 값을 계산하는데 필요한 형상계수를 결정하였으며, Polymethylmethacrylate(PMMA)를 사용하여 Round-CLWL 시편 채택의 타당성 확인을 위 한 MRL-CLWL과 Round-CLWL 시편 채택의 타당성 확인을 위한 MRL-CLWL과 Round-CLWL시 편의 $K_{1a}$결정 실험을 하였다.하였다.

XRR 박막 두께 표준물질 제작조건에 따른 구조적특성 연구

  • Yu, Byeong-Yun;Bin, Seok-Min;O, Byeong-Seong;Kim, Chang-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.283-283
    • /
    • 2011
  • 본 연구에서는 XRR 측정에 있어 박막두께 표준보급을 하기 위하여 표준물질을 이온빔 스퍼터링 증착법을 이용하여 제작하였다. 시편제작 시 공기 중 노출에 의해 산화가 되지 않는 산화물 박막과 산화물 기판을 선택하였다. 기판 및 타겟물질 등을 변화시키면서 제작된 시편의 특성을 살펴보았다. 사용된 타겟 물질로는 HfO2, Ta2O5, Cr2O3를 사용하였으며, 기판으로는 glass, sapphire, quartz, SiO2(1 ${\mu}m$-thermal oxidation)를 사용하였다. 산화물 타겟을 사용하여 증착 시 타겟 주위로 생기는 전하들의 charge build-up 되는 현상은 neutralizer를 사용함으로써 문제를 해결하였다. 제작된 시편은 XRR을 이용하여 측정하였고, XRR simulation과 curve fitting을 통하여 박막의 두께, 표면 및 계면의 거칠기, 밀도를 평가하였다. 기판으로 사용된 glass, quartz는 타겟 물질과 관계없이 표면 거칠기가 좋지 않아 XRR 반사율이 급격히 떨어지면서 측정되는 각도의 영역이 작아졌다. sapphire로 제작한 시편에서는 측정된 데이터와 simulation의 curve fitting이 양호하지 않았다. 이 문제는 현재 조사중에 있다. SiO2 기판으로 제작한 시편의 경우 타겟 물질과 관계없이 XRR curve fitting 결과가 양호 하였다. 그 중 Cr2O3의 결과가 다른 타겟 물질에 비해 x 2 값이 작았고 반사율 곡선에서의 거칠기와 진폭도 양호하였다. 위 연구결과로써 SiO2 기판을 사용한 Cr2O3 타겟 물질로 제작된 시편이 XRR 박막 두께 표준물질로써 적합한 것으로 판단된다.

  • PDF

An Investigation of Lattice Parameter Measurement of Inorganic Crystals by Electron Diffraction Patterns (전자회절도형을 이용한 무기시료의 격자상수 측정법 연구)

  • Lee, Young-Boo;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.29 no.1
    • /
    • pp.75-81
    • /
    • 1999
  • Optimum conditions for making the Au and Al internal standards for TEM have been determined experimentally. The Au internal standard was produced by sputter coating at 9mA for 100 seconds in low vacuum $(\leq1\times10^{-3})$. The Al internal standard was produced by evaporation coating at 7kV for 10 minutes in high vacuum $(\leq1\times10^{-5})$. Measurements of the lattice parameters of andalusite and albite feldspars with this Au internal standard resulted in errors of (a) $ \leq1.2%$ in precion and $\leq0.3%$ in accuracy for andalusite: (b) $\leq0.5%$ in precision and $\leq1.1%$ in accuracy for albite feldspars. The most significant error occurred from the measuring processes of distances and angles of electron diffraction patterns. By employing systematic procedures of measurement with high precision devices, this lattice parameter determination method utilizing the internal standard should be a good alternative to the conventional powder XRD method or the sophisticated CBED method for special samples.

  • PDF

최신 압입시험기를 이용한 산업설비의 비파괴 안전진단

  • Lee, Yoon-Hee;An, Jung-Hoon;Choi, Yeol;Son, Dong-Il;Jang, Jae-Il;Kwon, Dong-Il
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.9-16
    • /
    • 2000
  • 1970년대의 급격한 경제 성장시기에 건설된 구조물들은 30년 이상의 사용으로 인해 노후화가 심각하며 대형 산업재해의 가능성을 가지고 있다. 따라서 노후 설비들의 안전 한 사용을 위해서는 소재 물성의 정기적인 진단을 통한 정확한 수명예측이 필요하다. 그러나 기존의 소재 물성평가를 위한 표준 방법인 일축인장 및 파괴역학 시험의 경우, 변형 및 파괴 거동에 대한 많은 정보를 제공하고 있지만, Bulk 형태의 표준시편이 필요하여 시편을 채취하는 과정에서 설비와 구조물에 노치에 의한 손상이 가해질 수 있어 구조물의 안전성을 오히려 해치는 결과를 초래할 수 있다. 또한 채취 중의 응력완화 및 손상에 의해 표준시편도 본래 현장 구조물과 다른 물성을 가질 수 있다.(중략)

  • PDF

Difference of Translucency according to Drying Time after Staining of Dental Zirconia (치과용 지르코니아 착색 후 건조시간에 따른 반투명도의 차이)

  • Lee, Joo-Hee;Park, Jin-Young;Kim, Dong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.124-130
    • /
    • 2021
  • Dental prosthesis translucency importantly contributes to aesthetic outcomes. The purpose of this study was to investigate the effect of drying time and zirconia coloring agent type on translucency. For the experiment, 90 circular specimens were fabricated for each zirconia block. Then, zirconia specimens were treated with a coloring agent for 180 seconds and dried for 0 seconds (undried), 30 seconds (intermediate dry), or 30 minutes (complete dry). Then, a specimen was placed on a black standard tile or a white standard tile, and using a standard D65 light source reflected was measured using the light removal method. A total of three repeated measurements were obtained per specimen. One-way ANOVA was used to compare and analyze the relationship between zirconia translucency and drying time. Zirconia and coloring liquid types were significantly associated with translucency (P < 0.001). Although no significant difference was observed with respect to drying time (P > 0.922), zirconia in the completely dried (30 minutes) state was more translucent.

소형펀치시험에서 인장물성변화에 의한 시편의 변형거동과 하중-변위곡선에의 영향

  • 이재봉;박재학;김민철;이봉상
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.05a
    • /
    • pp.147-152
    • /
    • 2003
  • 원자로 압력용기 저합금강들은 원자로 가동 중 중성자 조사에 의해 재질열화 (material degradation)가 발생한다. 그러므로 계속적인 재질열화의 평가는 발전소의 수명을 예측, 평가하기 위해서 매우 중요하다. 그러나 표준시편을 이용한 인장시험, 충격시험 및 파괴인성 시험법 등은 조사시편의 크기 및 수량에 제한이 따르고, 높은 방사능으로 인해 시험편의 취급에도 제약을 받게 된다. 따라서 소형시편을 이용한 재료의 손상평가기술의 필요성이 부각되었고, 소형펀치시험(small punch test, SP test)은 그 중 하나의 유용한 시험 방법이다.(중략)

  • PDF

Compressive Fracture Behavior of ATJ Graphite for Rocket Nozzle (로켓 노즐목에 이용되는 ATJ 그라파이트 압축거동 평가)

  • Choi, Hoon Seok;Seo, Bo Hwi;Kim, Jae Hoon;Moon, Soon Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1435-1440
    • /
    • 2014
  • The effects of the specimen size and temperature on the compressive strength of ATJ graphite were investigated. Compressive tests were conducted in accordance with ASTM C 965 at room temperature, $700^{\circ}C$ and $900^{\circ}C$. Three types of cylindrical specimen at room temperature were used in uniaxial tests, where the diameter-to - length ratios were one to two for the ASTM standard specimen, one to one for the Type I specimen, and one to 0.5 for the Type II specimen. Two kinds of cylindrical specimens, with and without antioxidant coating, were tested at elevated temperature. The Compressive strength of the expanded specimens(Type I, II) were slightly higher than that of standard specimen at room temperature. The compressive strength of a specimen with antioxidant coating increased as the temperature increased to $900^{\circ}C$. In contrast, that of the non-coated specimen decreases sharply due to the oxidation of the specimen.

Acoustic Emission Application for Aerospace Composite Materials (항공용 복합재료에 대한 음향방출의 활용)

  • Lee, Sang-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.3
    • /
    • pp.313-318
    • /
    • 2001
  • To establish nondestructive test method for aerospace composite materials, various composite specimens were tested and analyzed using acoutic emission. The hit rate of acoustic emission closely was rotated with crack initiation and propagation. This report also presents defection capability of crack initiation pressure, initial crack active location, and crack propagation using acoustic emission.

  • PDF

A Study on Temperature Characteristics of Various Depth using Infrared Thermography (적외선 열화상기법을 이용한 균열 깊이에 따른 온도특성에 관한 연구)

  • Jung, Ju-Yeong;Yoon, Hyuk-Jin;Cho, Hyun-Woo;Yang, Hui-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.83-89
    • /
    • 2018
  • The thermal characteristics of concrete specimens were analyzed using cement paste specimens with artificial cracks. In order to understand the temperature characteristics of the specimen depending on the crack depth, the specimen was heated and the minimum temperatures of the specimens at which cracks appear were investigated according to the crack depth. It was confirmed that the surface temperature distribution of the specimen varies depending on whether the specimen is cracked or not, because of the single and multiple reflections of the incident energy. Furthermore, as the temperature distribution of the specimen reaches a steady state, the temperature data tends to decrease with the crack depth. Through the observation of the normalized temperatures, it was found that the temperature of the specimens obtained from this experiment reached a steady state after 10 minutes. At this time, the standard deviation of the normalized temperature is around 0.01 or less, and the temperature decreases linearly with increasing crack depth. This result is considered to be closely related to the area where multiple reflections occur in the cracked region. If the correlation between the crack region and the incident energy is analyzed for various specimens, it can be applied to the diffuse reflection of the light.