• Title/Summary/Keyword: 표준화환자

Search Result 374, Processing Time 0.021 seconds

An Study on the Correlation between Sound Characteristics and Sasang Constitution by CSL (CSL을 통한 음향특성과 사상체질간의 상관성 연구)

  • Shin, Mi-ran;Kim, Dal-lae
    • Journal of Sasang Constitutional Medicine
    • /
    • v.11 no.1
    • /
    • pp.137-157
    • /
    • 1999
  • The purpose of this study is to help classifying Sasang Constitution through correlation with sound characteristic. This study was done it under the suppose that Sasang Constitution has correlation with sound spectrogram. The following result were obtained about correlation between sound spectrogram and Sasang Constitution by comparison and analysis 1. Soeumin answered his voice low tone, smooth and quiet in the survey. Soyangin answered his voice high, clear, fast and speaking random. Taeumin answered his voice low, thick and muddy. 2. Taeyangin was significantly slow compared with the others in the time of reading composition. Taeyangin was significantly slow compared with the others in Formant frequency 1. Taeyangin was significantly discriminated from Soeumin in Formant frequency 5. Taeyangin was significantly low compared with the others in Bandwidth 2. Soeumln was significantly low compared with Taeyangin in Pitch Maximum and Pitch Maximum-Pitch Minimum. Taeyangin was significantly high compared with the others in Energy mean. 3. In list of specification, the discrimination rate was higher than that by lists of 13 in the results of Multi-dimensional 4-class minimum-distance. The discrimination rate of three disposition except Soyangin was higher than that of four disposition in the results of One way ANOVA and Analysis of dis crimination in SPSS/PC+. In CART, the estimate rate of Sasang Constitution discrimination was higher than any other method. It is considered that there is a correlation between sound spectrogram and Sasang constitution according to the results. And method of Sasang constitution classification through sound spectrogram analysis can be one method as assistant for the objectification of Sasang constitution classification.

  • PDF

FDG Uptake and a Contrast Enhancement According to Histopathologic Types in Lung Cancers (폐암의 조직학적 분류에 따른 종양의 FDG 섭취와 CT 조영증강정도에 관한 연구)

  • Han, You-Mie;Choe, Jae-Gol;Kim, Young-Chul;Park, Eun-Kyung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • Purpose: The aims of this study were to analyze correlation between the maximum standardized uptake value (SUVmax) of 2-[F-18]-fluoro-2-deoxy-d-glucose (FDG) on positron emission computed tomography (PET-CT) scan and the degree of contrast enhancement on computed tomography (CT) scan in lung cancers, and to recognize the difference in SUVmax and CT enhancement between groups of different histopathologic subtypes. Materials and Methods: Our study included 53 patients of pathologically confirmed primary lung cancer, who were performed PET-CT and post-contrast chest CT. We calculated initial and delayed SUVmax (SUV1, SUV2), difference between SUV1 and SUV2 (SUVd), retention index (RI), and the degrees of CT contrast enhancement of lung cancers. We analyzed these variables for subtypes of lung cancers. Results: The values (mean$\pm$ standard deviation) were $8.3{\pm}4.4$ for SUV1, $10.7{\pm}5.7$ for SUV2, $2.4{\pm}1.6$ for SUVd, $30{\pm}14$ for RI and $47.1{\pm}14.8$ HU (Hounsfield Unit) for degree of CT contrast enhancement. The difference of SUV1 and degree of CT enhancement between subtypes was not meaningful. SUV1 showed positive correlations with SUVd (r=0.74, p<0,01) and tumor size (r=0.58, p<0.01), but no significant correlation with degree of CT enhancement (r=0.06, p=0.69). In 10 cases, there was discrepancy in the same mass between the area of highest FDG-uptake and the area of highest contrast enhancement. Conclusion: We suggest that FDG uptake in lung cancer does not have a positive linear correlation with degree of CT enhancement. And there is no significant difference in FDG uptake and degree of CT enhancement between different subtypes of lung cancers.

The Study of Usefulness of Metal Artifact Reduction Algorithm and Artifacts Caused by Metallic Hip Prosthesis on PET/CT (PET/CT에서의 고관절 삽입물에 의한 인공물과 Metal Artifact Reduction Algorithm의 유용성에 대한 고찰)

  • Park, Min Soo;Ham, Jun Cheol;Cho, Yong In;Kang, Chun Goo;Park, Hoon-Hee;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.35-43
    • /
    • 2012
  • Purpose : PET/CT performed CT-based attenuation correction generates the beam hardening artifact by metallic implant. The attenuation correction causes over or underestimate of the area adjacent to metallic hip prosthetic material and change of $^{18}F$-FDG uptake. Also, the image quality and the diagnosability on genitourinary disease are reduced. Therefore, this study will evaluate the usefulness of MAR (Metal Artifact Reduction) algorithm method to improve the image quality on PET/CT. Materials and Methods : PET/CT was performed by fixing hip prosthesis in SPECT/PET phantom. In PET images with and Without MAR algorithm, the Bright streak, Dark streak, Metal region and Background area that appeared on CT were confirmed, and the change of each SUV (standardized uptake value) was analyzed. Also, in 15 patients who underwent total hip arthroplasty, each MAR algorithm and Without MAR algorithm and non attenuation correction was evaluated. Results : In PET image Without MAR algorithm, SUV of Bright streak region was $0.98{\pm}0.48$ g/ml; Dark streak region was $0.88{\pm}0.02$ g/ml; Metal region was $0.24{\pm}0.16$ g/ml, Background area was $0.91{\pm}0.18$ g/ml. In SUV of PET image with MAR algorithm, Bright streak region was $0.88{\pm}0.49$ g/ml, Dark streak region was $0.63{\pm}0.21$ g/ml, Metal region was $0.06{\pm}0.07$ g/ml, Background was $0.90{\pm}0.02$ g/ml. SUV generally decreased when applying MAR algorithm. In PET image Without MAR algorithm, SUVs of Bright region were higher than those measured in the Background, and it was false positive uptake. But, in PET image with MAR algorithm, SUVs of Bright region were similar to the Background, and false positive uptake disappeared. Conclusion : MAR algorithm could reduce an increase of $^{18}F$-FDG uptake due to attenuation correction in the hip surrounding tissue. However, decrease of SUV in Dark streak region should be considered in the future. Therefore, this study propose that the diagnostic accuracy can be improved in genitourinary diseases adjacent to metallic hip prosthesis, if provided PET images with and Without MAR algorithm, and non attenuation correction images at the same time.

  • PDF

The Ratio of Medical Aid over Health Insurance of Age Adjusted Mortality Rate of Tuberculosis and Related Factors (의료보장유형에 따른 연령표준화 결핵 사망률비와 관련 요인)

  • Na, Baeg-Ju;Kang, Moon-Young;Hong, Jee-Young;Kim, Eun-Young;Kim, Keon-Yeop;Lee, Moo-Sik;Yang, Sang Kyu
    • Journal of agricultural medicine and community health
    • /
    • v.31 no.1
    • /
    • pp.9-20
    • /
    • 2006
  • Objectives: This study was aimed at investigating the ratio of medical aid over health insurance of age adjusted mortality rate of tuberculosis and related factors. And we want to compare the ratio of medical aid over health insurance of age adjusted mortality rate of tuberculosis and related factors among the provinces. Methods: In order to compare, the data was referred to National health insurance center for affirming the insurance type of the dead. And age adjusted mortality rate of tuberculosis of each insurance type was analyzed by whole country and the provinces. Related factors of the provinces were gathered from public statistic books. We analysed correlation study between the ratio of medical aid over health insurance of age adjusted mortality rate of tuberculosis and related factors among the provinces. Results: Major findings were as follows 1. The ratio of medical aid over health insurance of age adjusted mortality rate of tuberculosis was 5.6. And the ratio was relatively high at 40-60 ages. 2. The ratio of medical aid over health insurance of age adjusted mortality rate of tuberculosis by the province was varying. And the factors that were financial independence, crowdedness, percent of people on medical aid, population size served by each public health center, number of hospital by a million peoples have correlated with increment of the ratio. Conclusions: As a consequence of tuberculosis control, the ratio was high. Thus this finding suggests that medical utilization and preventive behavior, environment of tuberculosis patient are under handicapped condition. Especially large cities like metropolitan area who have high financial independence, high population density, high percentage of medical aid peoples have high ratio of medical aid over health insurance of age adjusted mortality rate of tuberculosis. There is need for additional and systematic research on the attitude or tendency toward medical services(inc1uding preventive services) utilization of medical aid tuberculosis patients.

  • PDF

$^{18}F$-FDG PET/CT for the Preoperative Diagnosis of Papillary Thyroid Microcarcinoma: The Value of Dual Time Point Imaging (갑상선미세유두암의 수술 전 진단에서 $^{18}F$-FDG PET/CT: 이중시간 영상의 유용성)

  • Seo, Young-Duk;Kim, Seong-Min;Kim, Kun-Ho;Kim, Je-Ryong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.543-556
    • /
    • 2009
  • Purpose: We studied the patterns of FDG uptake of primary papillary thyroid microcarcinoma (PTMCa) lesions and benign thyroid nodules in dual time point $^{18}F$-FDG PET/CT imaging. Materials and Methods: Consecutive 134 patients (154 lesions) with PTMCa and 49 patients (61 nodules) with benign thyroid nodules equal to or less than 1.0 cm who underwent dual time point $^{18}F$-FDG PET/CT study before surgery were enrolled. We calculated the maximum standardized uptake value of PTMCa and benign nodules in both time points, and percent change of SUVmax (${\Delta}%SUVmax$) and lesion to background ratio of SUVmax (${\Delta}L:B$% ratio) between both time points. The mean time interval between scans was $23.4{\pm}4.4$ minutes (thyroid to thyroid interval: $10.7{\pm}4.4$ minutes). Results: The mean of SUVmax of PTMCa was increased from $4.9{\pm}4.3$ to $5.3{\pm}4.7$ (p<0.001) and ${\Delta}%SUVmax$ was $12.3{\pm}23.6%$. But, the mean of SUVmax of benign nodules was no definite change ($2.1{\pm}1.0$ to $2.1{\pm}1.3$, p=0.686) and ${\Delta}%SUVmax$ was $-0.3{\pm}20.5%$. Of the 154 PTMCa, 100 nodules (64.9%) showed an increase in SUVmax over time, while 19 (31.1%) of the 61 benign thyroid nodules showed an increase (p<0.001). The dual time point $^{18}F$-FDG PET/CT found more PTMCa in visual assessment (62.3% vs. 76.6%, p=0.006), even in smaller than 0.5 cm (38.6% vs. 60.0%, p=0.011). Conclusion: Dual time time $^{18}F$-FDG PET/CT imaging was more useful than single time point $^{18}F$-FDG PET/CT imaging for distinction between PTMCa and benign nodule, especially when nodule showed equivocal or negative findings in single time point $^{18}F$-FDG PET/CT imaging or was smaller than 0.5 cm.

Harmonization of Hemolysis Index in Clinical Chemistry Laboratory and Its Application as a Result Verification Tool (화학검사 결과의 검증을 위한 용혈 지수 일치화 도구 개발)

  • Pyo, Sang Shin;Nam, Hyun Su;Cha, Young Jong;Lee, Seungkwan;Lee, Hae Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.350-358
    • /
    • 2017
  • The hemolysis index (HI) is semi-quantitative marker for hemolysis. Because the characteristics of the HI vary from one commercial platform to another, no standardization or harmonization of the HI is currently available. Specimens (N=40) randomly selected from clinical patients were artificially hemolyzed in vitro. The serum of the specimens was then diluted with a 20 mg/dL difference between 0~300 mg/dL based on serum hemoglobin measured using the XE-2100 hematology automation equipment (Sysmex, Japan). Diluted serum was measured using the Hitachi-7600 biochemical automation equipment (Hitachi, Japan) to differentiate between HI and serum hemoglobin. The data showed linearity between HI and serum hemoglobin and that HI 1 contained approximately 20 mg/dL of serum hemoglobin. To determine the blood rejection threshold, the HI was divided into three groups: HI 0~1, HI 4~6, HI 9~15. After another batch of clinical specimens (N=40) was measured using a Hitachi-7600 (Hitachi, Japan), each specimen was moved forward and backward with the piston of the syringe to induce an artificial in vitro hemolysis, then measured again with a Hitachi-7600 (Hitachi, Japan). The percentage difference between the three groups was analyzed by ANOVA or the Kruskal-Wallis test. In the post-test, there were significant differences between the HI 0~1 and the HI 5~6: Glucose, creatinine, total protein, AST, direct bilirubin, uric acid, phosphorus, triglyceride, LDH, CPK, Magnesium, and potassium levels. Because many clinical tests differed significantly, the threshold for hemolysis could be appropriate for HI 5 (serum hemoglobin 100 mg/dL).

Geochemistry of Granites in the Southern Gimcheon Area of Korea (김천남부에 분포하는 화강암류의 지구화학)

  • 윤현수;홍세선
    • The Journal of the Petrological Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.16-31
    • /
    • 2003
  • The granites in the southern Gimcheon area can be divided into two parts, marginal hornblende biotite granodiorite (Mgd) and central biotite granodiorite to granite (Cgd). Mgd and Cgd are gray in color and display gradational contact relations and are mainly composed of coarse-grained and medium-grained rocks, respectively. Mgd has more frequent and larger mafic enclaves than Cgd, and the two granites partly show parallel foliation at thire contact with gneisses. From representative samples of the granites, K-Ar biotite ages of 197∼207 Ma were obtained. Considering the blocking temperature of biotite, it is suggested that the emplacement age of the granitic magma was probably late Triassic. The anorthite contents of plagioclases in Mgd display less variation than those of Cgd, indicating that Mgd crystallized within a narrow range of temperatures. In the Al$\_$total/-Mg diagram, the biotites from the granites plot within the subalkaline field, and the smooth slope indicates differentiation from a single magma. All amphiboles from the granites belong to magnesio-hornblende. The linear trends of major oxides, AFM and Ba-Sr-Rb indicate that Mgd and Cgd were fractionally differentiated from a single granitic magma body crystallizing from the margin inwards. The relations of modal (Qz+Af) vs. Op, K$_2$O vs. Na$_2$O, Fe$_2$ $O_3$ vs. FeO, Fe$\^$+3/(Fe$\^$+3/+Fe$\^$+2/) and K/Rb vs. Rb/Sr show that they belong to I-type and magnetite-series granitic rocks developed by the progressive melting products of fixed sources. REE data, normalized to chondrite value, have trends of enriched LREE and depleted HREE together with weakly negative Eu anomalies.

The Development of Quality Assurance Program for CyberKnife (사이버나이프의 품질관리 절차서 개발)

  • Jang, Ji-Sun;Kang, Young-Nam;Shin, Dong-Oh;Kim, Moon-Chan;Yoon, Sei-Chul;Choi, Ihl-Bohng;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Kwon, Soo-Il;Lee, Dong-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.185-191
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: Standardization quality assurance (QA) program of CyberKnife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for CyberKnife and evaluation of the feasibility under applications. $\underline{Materials\;and\;Methods}$: Considering the feature of constitution for systems and the therapeutic methodology of CyberKnife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two CyberKnife centers. The acceptable tolerance was based on the undertaking inspection list from the CyberKnife manufacturer and the QC results during last three years of two CyberKnife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. $\underline{Results}$: The current QA status of two CyberKnife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. $\underline{Conclusion}$: It is considered that the developed QA program in this research could be established the standardization of QC methods for CyberKnife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy.

Empirical Study of Key Factors in Satisfaction with Subway Services (지하철 이용만족도 결정요인에 관한 실증적 연구 -서울지역을 중심으로-)

  • Shim, Jong-Seop;Jeon, Ki-Heung
    • Korean Business Review
    • /
    • v.13
    • /
    • pp.49-66
    • /
    • 2000
  • Despite the fact that understanding customers satisfaction with transportation services is a subject of great importance, authors, so far, found no systematic researches referred to that issue. From this point, studying the satisfaction with subways services can be extremely useful. Empirical study of key factors in the satisfaction with subway services is the departure point, which holds as objectives, and we believe, will contribute to overall increasing in the number of subways services used and in the amount of public benefits derived from that usage. In order to achieve these goals: First, several items referred to some key factors in the satisfaction of subway usage were systemized. Second, a research of specific weights attached to those key factors by subway passengers was conducted. Knowledge of the satisfaction variables system can provide deep insights into ones perceptual experience when using a subway. The results were as follows: Various interrelated factors compose a passengers satisfaction with subway services. People do not just use subway passively; a number of key factors, like physical and personal services, exact timing, easiness to access etc. determine the passengers satisfaction with subway. In order to find out specific weights of these key factors multiple regression analysis was employed. Results showed that satisfaction with subway is determined by (in order of importance) easiness to access, quality of physical services, friendliness of working stuff and timing exactness. According to the findings, passengers do not use subway as a simple mean of transportation, rather they perceive it as a complex combination of environmental elements and overall satisfaction depends on these various factors. Therefore, to learn passengers satisfaction with subways services, passengers subway experience must be thoroughly studied and analyzed, and this is where papers value resides.

  • PDF

STANDARDIZATION OF WORD/NONWORD READING TEST AND LETTER-SYMBOL DISCRIMINATION TASK FOR THE DIAGNOSIS OF DEVELOPMENTAL READING DISABILITY (발달성 읽기 장애 진단을 위한 단어/비단어 읽기 검사와 글자기호감별검사의 표준화 연구)

  • Cho, Soo-Churl;Lee, Jung-Bun;Chungh, Dong-Seon;Shin, Sung-Woong
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.14 no.1
    • /
    • pp.81-94
    • /
    • 2003
  • Objectives:Developmental reading disorder is a condition which manifests significant developmenttal delay in reading ability or persistent errors. About 3-7% of school-age children have this condition. The purpose of the present study was to validate the diagnostic values of Word/Nonword Reading Test and Letter-Symbol Discrimination Task for the purpose of overcoming the caveats of Basic Learning Skills Test. Methods:Sixty-three reading-disordered patients(mean age 10.48 years old) and sex, age-matched 77 normal children(mean age 10.33 years old) were selected by clinical evaluation and DSM-IV criteria. Reading I and II of Basic Learning Skills Test, Word/Nonword Reading Test, and Letter-Symbol Discrimination Task were carried out to them. Word/Nonword Reading Test:One hundred usual highfrequency words and one hundred meaningless nonwords were presented to the subjects within 1.2 and 2.4 seconds, respectively. Through these results, automatized phonological processing ability and conscious letter-sound matching ability were estimated. Letter-Symbol Discrimination Task:mirror image letters which reading-disordered patients are apt to confuse were used. Reliability, concurrent validity, construct validity, and discriminant validity tests were conducted. Results:Word/Nonword Reading Test:the reliability(alpha) was 0.96, and concurrent validity with Basic Learning Skills test was 0.94. The patients with developmental reading disorders differed significantly from normal children in Word/Nonword Reading Test performances. Through discriminant analysis, 83.0% of original cases were correctly classified by this test. Letter-Symbol Discrimination Task:the reliability(alpha) was 0.86, and concurrent validity with Basic Learning Skills test was 0.86. There were significant differences in scores between the patients and normal children. Factor analysis revealed that this test were composed of saccadic mirror image processing, global accuracy, mirror image processing deficit, static image processing, global vigilance deficit, and inattention-impulsivity factors. By discriminant analysis, 87.3% of the patients and normal children were correctly classified. Conclusion:The patients with developmental reading disorders had deficits in automatized visuallexical route, morpheme-phoneme conversion mechanism, and visual information processing. These deficits were reliably and validly evaluated by Word/Nonword Reading Test and Letter-Symbol Discrimination Task.

  • PDF