• Title/Summary/Keyword: 표준화된 섭취값

Search Result 12, Processing Time 0.033 seconds

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Quantitative Ga-67 Scintigraphy in patients with Silicosis: Comparison with Chest X-ray and Pulmonary Function (규폐증에서 Gallium-67 신티그라피의 정량적인 분석: 흉부 X-선과 폐기능검사와의 비교)

  • Shin, Kwang-Hyun;Sohn, Hyung-Sun;Chung, Yong-An
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.381-387
    • /
    • 1999
  • Purpose: The International Labor Organization (ILO) has established an international standard for chest X-ray diagnosis of pneumoconiosis since 1980. However, there is a need for improved diagnosis and staging in occupational disease. We evaluated Ga-67 citrate scintigraphy quantitatively and correlated the scintigraphic findings with pulmonary function tests and chest X-ray results. Materials and Methods: Twenty-five patients underwent whole body scintigraphy with additional chest and abdomen images 48 hrs after intravenous injection of 185 MBq of Ga-67 citrate. Ten normal controls were also studied. Regions of interest (ROI) were drawn on the posterior image to measure counts from the liver and lungs (Lung/Liver Ratio). Results: L/L ratio according to the stages of chest X-ray classification were as follows; stage 0 (normal, n=10): $0.3948{\pm}0.0692$, stage 1 (n=10): $0.5763{\pm}0.1537$, stage 2 (n=11), $0.6849{\pm}0.1459$, stage 3 (n=4) $0.9913{\pm}0.0712$. There was a significant correlation between the scintigraphic L/L ratio and the X-ray stage (r=0.618, p<0.05). However, no significant correlation between L/L ratio and pulmonary function tests were observed (p>0.05). Conclusion: Quantitative Ga-67 scintigraphy can be a useful method for staging of silicosis. However, it is not a method to assess pulmonary functional impairment.

  • PDF

Development of nutrition quotient for Korean preschoolers (NQ-P): Item selection and validation of factor structure (취학전아동 대상 영양지수 개발 : 평가항목 선정과 구성 타당도 검증)

  • Lee, Jung-Sug;Kang, Myung-Hee;Kwak, Tong-Kyung;Chung, Hae Rang;Kwon, Sehyug;Kim, Hye-Young;Hwang, Ji-Yun;Choi, Young-Sun
    • Journal of Nutrition and Health
    • /
    • v.49 no.5
    • /
    • pp.378-394
    • /
    • 2016
  • Purpose: Screening of preschool-age children for nutrition programs to improve dietary intake and behaviors requires cost-effective and easily administered validated assessment tools. The purpose of this study was to develop a parent/caregiver-administered instrument for measuring diet quality and behaviors of preschoolers as a nutrition quotient for preschoolers (NQ-P). Methods: Development of NQ-P was carried out in three steps: item generation, item reduction, and validation. The 24-h dietary record was selected as the gold standard reference tool. The 38 items of the NQ-P checklist were derived from a systematic literature review, expert in-depth interviews, statistical analysis of the fifth Korean National Health and Nutrition Examination Survey data, and national nutrition policies and recommendations. Self-administered questionnaires were delivered to parents who recorded 24-h dietary intakes of 100 responders aged 3~5 yr. Pearson's correlation was used to measure the level of agreement between questionnaires. Item reduction was performed, and 20 items were selected based on survey results, expert reviews, and priorities of national nutrition policy and recommendations. The 412 nationwide subjects sampled through daycare centers completed the 20-item checklist questionnaire. The construct validity of the NQ-P was assessed using confirmatory factor analysis, LISREL. Results: After analyses of exploratory factors, NQ-P items identified three dimensions of diet (balance, moderation, and environment). The three-factor structure accounted for 49.28% of the total variance. Standardized path coefficients were used as weights of the items. The NQ-P and three-factor scores of the subjects were calculated by the obtained weights of the questionnaire items. Conclusion: A food behavior checklist for preschoolers' NQ would be a useful and suitable instrument for evaluating nutrition adequacy and dietary quality of Korean preschoolers.

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

Prognostic Usefulness of Maximum Standardized Uptake Value on FDG-PET in Surgically Resected Non-small-cell Lung Cancer (수술로 제거된 비소세포폐암의 예후 예측에 있어 FDG-PET 최대 표준화 섭취계수의 유용성)

  • Nguyen Xuan Canh;Lee Won-Woo;Sung Sook-Whan;Jheon Sang-Hoon;Kim Yu-Kyeong;Lee Dong-Soo;Chung June-Key;Lee Myung-Chul;Kim Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.205-210
    • /
    • 2006
  • Purpose: FDG uptake on positron omission tomography (PET) has been considered a prognostic indicator in non-small cell lung cancer (NSCLC). The aim of this study was to assess the clinical significance of maximum value of SUV (maxSUV) in recurrence prediction in patients with surgically resected NSCLC. Materials & methods: NSCLC patients (n=42, F:M =14:28, age $62.3{\pm}12.3$ y) who underwent curative resection after FDG-PET were enrolled. Twenty-nine patients had pathologic stage 1, and 13 had pathologic stage II. Thirty-one patients were additionally treated with adjuvant oral chemotherapy. MaxSUVs of primary tumors were analyzed for correlation with tumor recurrence and compared with pathologic or clinical prognostic indicators. The median follow-up duration was 16 mo (range, 3-26 mo). Results: Ten (23.8%) of the 42 patients experienced recurrence during a median follow-up of 7.5 mo (range, 3-13 mo). Univariate analysis revealed that disease-free survival (DFS) was significantly correlated with maxSUV (<7 vs. $\geq7$, p=0.006), tumor size (<3 cm vs. $\geq3$ cm, p=0.024), and tumor tell differentiation (well/moderate vs. poor, p=0.044). However, multivariate Cox proportional analysis identified maxSUV as the single determinant for DFS (p=0.014). Patients with a maxSUV of $\geq7$(n=10) had a significantly lower 1-year DFS rate (50.0%) than those with a maxSUV of <7 (n=32, 87.5%). Conclusion: MaxSUV is a significant independent predictor for recurrence in surgically resected NSCLC. FDG uptake can be added to other well-known factors in prognosis prediction of NSCLC.

Analysis of Urine Iodine Excretion Decrease by Two-Week Stringent Low Iodine Diet for Remnant Thyroid Ablation with Radioactive Iodine in Korean Patients with Thyroid Cancer; Prospective Study (한국 갑상선암 환자들에서 잔여갑상선 제거를 위한 방사성요오드 치료 전 2주간의 엄격한 저요오드식이에 의한 소변 내 요오드량 감소 분석; 전향적 연구)

  • Choi, Joon-Hyuk;Kim, Hoon-Il;Park, Jang-Won;Song, Eun-Hoon;Ko, Bong-Jin;Cheon, Gi-Jeong;Kim, Byung-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.375-382
    • /
    • 2008
  • A low iodine diet (LID) is the recommended preparation for radioactive iodine treatment. However, the recommended duration and stringency of LID are different among each recommendation. More stringent LID is expected in Korea because Korea is a iodine-rich region. We investigated the decrement of urine iodine excretion by two-week stringent LID for remnant thyroid ablation with radioactive iodine in Korean patients with thyroid cancer, prospectively. Material and Method: From November 2006, patients who referred to our hospital for remnant ablation after total thyroidectomy were included in this study. To decrease total body iodine, our protocol included three strategies. First, we checked medication which could inhibit the radioactive iodine uptake. Second, the date of 1-131 treatment was scheduled at least 3 months later if contrast agent had been used. The last strategy was two-week stringent LID education by specialized nutritionist. Before and after two-week stringent LID, 24hr-urine iodine was analyzed respectively. 24hr-urine creatinine was also analyzed for determining more valid 24hr urine sampling subgroup. Results: Total 51 patients were finally enrolled. Average of 24hr-urine iodine excretion was significantly lowered ($787{\pm}2242\;{\rightarrow}\;85{\pm}85\;{\mu}g/d$, p=0.03) after LID and 74.4% of patients reached below the recommended urine iodine excretion level ($<100\;{\mu}g/d$). In subgroup (n=14), similar results was showed ($505{\pm}666\;{\rightarrow}\;99{\pm}116\;{\mu}g/d$, p=0.05) and 78.6% of patients met the criteria. Conclusion: Most patients could reach below the recommended urine iodine level after two-week stringent LID. Therefore, in our opinion, at least two-week stringent LID should be recommended in Korea.

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

A Study on Artificiality Salivary pH and Sugar Fermentation Test of Caries Potentiality Foods (우식유발식품에 의한 인공타액내 pH 변화와 당 분해 효소 활성에 관한 연구)

  • Ji, Yun-Jeong;Park, Su-Kyung
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.303-309
    • /
    • 2012
  • This study was designed to provide basic data for developing a standardized caries potentiality index to help to choose snack foods with a low score on the index by investigating adolescents' snack intakes and measuring them in total saccharinity, pH, and acidogenic potential and glucosidase activity of Streptococcus mutans (S. mutans). Total 28 snack foods were selected and measured for total saccharinity (Pocket refractometer PAL-1, ATAGO) and pH with a pH meter (Mentor, Seoul, Korea). Artificial saliva was added to each sample. The experiment group was administered with S. mutans (ATCC 3692), cultured in a constant temperature incubator at $37^{\circ}C$, and measured for pH changes over five times including after 10 minutes, 30 minutes, 1 hour, and 24 hours. Each sample of 0.3 ml was added to tubes containing sucrose, galactose, or glucose to measure the glucosidase activity of S. mutans. They were then observed for glucosidase activity with colorimetry after 24 hours of culture in a constant temperature incubator at $37^{\circ}C$. The mean pH by the acidogenic potential of S. mutans was pH 5.33. The experiment group dropped in pH more than the control group due to the increasing acidogenic potential of S. mutans by glucosidase activity, recording pH 5.27 after 10 minutes, pH 5.21 after 30 minutes, pH 5.15 after 1 hour, and pH 4.80 after 24 hours. The observation results of glucosidase activity of S. mutans with colorimetry show that most of the samples were positive in orange and yellow with glucose, sucrose, and glactose recording activity of 78.58%, 75%, and 71.42%, respectively.

Caffeinated Food Consumption Patterns and Level among High School Students in Yongin Region (용인지역 고등학생의 카페인 함유 식품의 소비 패턴 및 소비 수준)

  • Park, Eun Jeong;Kim, Seong Yeong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.9
    • /
    • pp.1128-1136
    • /
    • 2017
  • Previous studies of the caffeine consumption pattern were limited primarily to beverages containing caffeine. Therefore, this study examined the caffeine consumption patterns and levels in beverages and foods containing caffeine among high school students (n=310) in the Yongin region. The participants included 171 boys (55.2%) and 139 girls (44.8%). The daily mean caffeine intake of the respondents was 41.27 mg (0.651 mg/kg) and 36.47 mg (0.696 mg/kg) in boys and girls, respectively. Among the caffeinated food groups, coffee had the highest caffeine intake group in both boys (18.95 mg) and girls (26.28 mg). Girls consumed large amounts of caffeine in the form of Americano-style coffee (20.04 mg), whereas boys consumed more canned coffee (6.77 mg) than girls (2.43 mg, P<0.01). Carbonated soft drinks were the second most prevalent source of caffeine intake in both groups, even though boys (14.29 mg) consumed larger amounts of caffeine than girls (5.85 mg, P<0.001). Multiple regression analysis investigating the major contributing food group to daily total caffeine intake also showed that the highest standardized coefficient was in coffee regardless of gender (boys 0.492, P<0.001 and girls 0.944, P<0.001), followed by carbonated soft drinks and energy drinks. Approximately 95% of high school students consumed normal levels of caffeine, whereas 3.5% of boys and 5.8% of girls consumed excessive amounts based on the standard limit of Korea Food and Drug Administration (<2.5 mg/kg/d) for adolescents. The daily mean caffeine intake of the excess group was 5.38 mg/kg and 6.96 mg/kg in boys and girls, respectively. Consequently, safe daily caffeine intake needs to be determined throughout continuous national management guidelines and nutritional education.

The study on Standard Uptake Value(SUV) change according to time input difference in PET/CT scan (PET/CT 검사에서 시간 입력 차이에 따른 표준화섭취계수(SUV) 변화에 대한 고찰)

  • Kim, Kyung-Sik;Lee, Ju-Young;Jung, Woo-Young;Kim, Jung-Sun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.21-25
    • /
    • 2011
  • Purpose: $^{18}F$-FDG Fusion Whole Body PET scan is performed approximately 1 hour after injecting $^{18}F$-FDG. At this point in the injection procedure, as a tool of the criteria of time input, time of clocks or computers can be used and in the scan procedure, time of workstation can be used. In case that synchronized time input is not done in the injection and scan procedures for PET scan, time error from injection to scan can occur. This time error may affect Standard Uptake Value (SUV) being used as quantitative assessment. Therefore, in this study, we analyzed the change of SUV according to time input difference and necessity of time synchronization. Materials and Methods: The analysis was performed to 30 patients ($54.8{\pm}15.5$ years old) who examined $^{18}F$-FDG Fusion Whole Body PET scan in Department of nuclear medicine, Asan Medical Center from December 2009 to February 2010. To observe the change of SUV according to time input difference, the image was reconstructed and analyzed by artificially changing time difference of 1, 2, 3, 5, 10, 20 min against the same patients based on 60 minutes. Result: SUV of the image that reconstructed the images of 30 patients by giving intervals of 1, 2, 3, 5, 10, 20 min respectively and the image that entered original time was compared and analyzed through paired t-test. Based on 0 minute, mean SUV of aorta was changed by 0.3, 1.1, 1.4, 3.2, 4.7, 12.5% respectively and there was no statistically significant difference in 1, 2 minutes (p>0.05) but there was significant difference in 3, 5, 10, 20 min (p<0.05). The changes of $SUV_{avg}$ of liver were 1.6, 2.5, 3.0, 4.2, 6.6, 12.8% in 1, 2, 3, 5, 10, 20 min respectively and the changes of $SUV_{max}$ of primary lesion were 1.0, 1.5, 2.2, 3.5, 6.6, 12.8% respectively (p<0.05). Conclusion: Errors may occur in the process of measuring or recording variables affecting SUV such as height and weight of patients, $^{18}F$-FDG dose, Emission scan start time etc. and as these errors are more, the accurate assessment of SUV is interfered. Therefore, in order to assess SUV more accurately, it is thought that efforts to minimize these errors should be made. Of these efforts, time synchronization will be a cornerstone for accurate scanning.

  • PDF