• Title/Summary/Keyword: 표준측정법

Search Result 869, Processing Time 0.031 seconds

Clinical Usefulness of Contrast Echocardiography: The Dose Effect for Left Ventricle Visualization in Dogs (심초음파의 조영제의 임상적 유용성: 개에서 좌심영상화에 대한 조영제 용량의 영향)

  • Shin, Chang-ho;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.486-490
    • /
    • 2015
  • Two-demensional echocardiography is routinely used for evaluation of cardiac function. Visualization of the endocardial border is essential for the assessment of global and regional left ventricular with cardiac disease. SonoVue$^{TM}$ is a microbubble contrast agent that consists of sulfur hexafluoride-filled microbubbles in a phospholipid shell. There were many studies about contrast echocardiographic examination using SonoVue$^{TM}$ contrast agent, and various doses of SonoVue$^{TM}$ were used. To our knowledge, in published veterinary medicine, there was not reported for diagnostic efficient dose of SonoVue$^{TM}$ to evaluate contrast enhanced left ventricular endocardial border delineation (LVEBD). The purpose of this study is to compare the visualization time of LVEBD and find efficient dose of SonoVue$^{TM}$ for using various doses in dogs. Ten healthy Beagles were recruited to the study. Three different doses (0.03 ml/kg, 0.05 ml/kg and 0.1 ml/kg) of SonoVue$^{TM}$ were injected. Endocardial segments were assigned based on previously established methodology, where by the four-chamber views of the LV were divided into 6 segments. In this study, Contrast enhancement of the LVEBD after each injection was evaluated visually at the time point of overall contrast enhancement (Segmental scoring 5+) in the LV by three investigators in a blind manner. Statistical analysis was performed with SPSS version 14.0. All data were analyzed using one-way ANOVA, the multiple comparison Scheffe test. When data for the three offsite readers were combined, mean durations of useful contrast were $3.54({\pm}2.14)$, $6.15({\pm}2.61)$, and $24.39({\pm}11.10)$ seconds for the 0.03 ml/kg, 0.05 ml/kg, and 0.1 ml/kg SonoVue$^{TM}$ doses, respectively. After injection of contrast agent, there were no significant change in side effects such as urticaria, angioedema, hypersensitivity reactions, and digestive system disorders. This study suggests that efficient dose of SonoVue$^{TM}$ contrast agent for improvement of the left ventricle visualization is 0.1 ml/kg. The duration of useful enhancement of LVEBD and the reproducibility were also the highest at the 0.1 ml/kg dosage.

Improvement of Oxygen Isotope Analysis in Seawater samples with Stable Isotope Mass Spectrometer (질량분석기를 이용한 해수 중 산소안정동위원소 분석법의 개선)

  • Park, Mi-Kyung;Kang, Dong-Jin;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.4
    • /
    • pp.348-353
    • /
    • 2008
  • Oxygen isotope has not been used actively in water mass studies because of difficulties on the analysis though it has advantages as a water mass tracer. The most popular method to analysis the oxygen isotope ratio in water samples is equilibration method: isotopic equilibrium of water with $CO_2$ at constant temperature. The precision of oxygen isotope analysis using commercial automatic $H_2O/CO_2$ equilibrator is ${\pm}0.1%o$. This value is not sufficient for studies in open ocean. The object of this study is to improve the analytical precision enough to apply open ocean studies by modification of the instrument. When sample gas is transferred by the pressure difference, the fractionation which is preferential transportation of light isotope can be occurred since the long transportation path between the equilibrator and mass spectrometer. And the The biggest source of error during the analysis is long distance and large volume of the pathway of sample gas between. Therefore, liquid nitrogen trap and high vacuum system are introduced to the system. The precisions of 14 time analysis of same seawater sample are ${\pm}0.081%o$ and ${\pm}0.021%o$ by built-in system and by modified system in this study, respectively.

2007 Korean National Growth Charts: review of developmental process and an outlook (2007 한국 소아 청소년 성장도표 : 개발 과정과 전망)

  • Moon, Jin Soo;Lee, Soon Young;Nam, Chung Mo;Choi, Joong-Myung;Choe, Bong-Keun;Seo, Jeong-Wan;Oh, Kyungwon;Jang, Myoung-Jin;Hwang, Seung-Sik;Yoo, Myung Hwan;Kim, Young Taek;Lee, Chong Guk
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.1
    • /
    • pp.1-25
    • /
    • 2008
  • Purpose : Since 1967, The Korean Pediatric Society and Korean Government have developed Korean Growth Standards every 10 years. Last version was published in 1998. During past 40 years, Korean Growth Standards were mainly descriptive charts without any systematic nor statistical standardization. With the global epidemic of obesity, many authorities such as World Health Organization (WHO) and United States' Centers for Disease Control (CDC) have been changed their principles of growth charts to cope with the situations like ours. This article summarizes and reviews the whole developmental process of new 2007 Korean Growth Charts with discussion. Methods : With the initiative of Division of Chronic Disease Surveillance in Korea Centers for Disease Control and Prevention, we have performed new national survey for the development of new Standards in 2005 and identified marked increase of childhood obesity and plateau of secular increment of final height in late adolescents. We have developed new Growth Standards via adapting several innovative methods, including standardization of all available raw data, which were acquired in 1997 and 2005 national survey and full application of LMS method. Results : We could get new standardized charts; weight-for-age, length/height-for-age, weight-for-height, head circumference-for-age and BMI-for-age. Other non-standardized charts based on 2005 survey data were also published; waist circumference-for-age, mid-arm circumference-for-age, chest circumference-for-age and skinfold-for-age. Clinical guideline was also developed. Conclusion : Developmental process and results of new Korean Growth Charts are comparable with other internationally well-known Growth Standards, WHO 2006 Growth Standards and CDC Growth Charts. 2007 Korean Growth Charts are relevant especially in Korea and Korean ethnic groups.

Neurochemical Profile Quantification of Regional Adult Mice Brain Using: ex vivo $^1H$ High-Resolution Magic Angle Spinning NMR Spectroscopy (생체 외 조직 고 분해능 Magic Angle Spinning을 이용한 정상 Adult Mice에서의 뇌 부위별 뇌 신경화학 대사물질 정량분석)

  • Lee, Do-Wan;Woo, Dong-Cheol;Lee, Sung-Ho;Kim, Sang-Young;Kim, Goo-Young;Rhim, Hyang-Shuk;Choi, Chi-Bong;Kim, Hwi-Yool;Lee, Chang-Wook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.35-41
    • /
    • 2010
  • The purpose of this study is to quantitate regional neurochemical profile of regional normal adult mice brain and assess regional metabolic differences by using ex vivo $^1H$ high-resolution magic angle spinning nuclear magnetic resonance spectroscopy ($^1H$ HR-MAS NMRS). The animals were matched in sex and age. The collected brain tissue included frontal cortex, temporal cortex, thalamus, and hippocampus. Quantitative 1D spectra were acquired on 40 samples with the CPMG pulse sequence (8 kHz spectral window, TR/TE = 5500/2.2 ms, NEX = 128, scan time: 17 min 20 sec). The mass of brain tissue and $D_2O$+TSP solvent were 8~14 mg and 7~13 mg. A total of 16 metabolites were quantified as follow: Acet, NAA, NAAG, tCr, Cr, tCho, Cho, GPC + PC, mIns, Lac, GABA, Glu, Gln, Tau and Ala. As a results, Acet, Cho, NAA, NAAG and mIns were showed significantly different aspects on frontal cortex, hippocampus, temporal cortex and thalamus respectively. The present study demonstrated that absolute metabolite concentrations were significantly different among four brain regions of adult mice. Our finding might be helpful to investigate brain metabolism of neuro-disease in animal model.

Catch up growth in children born small for gestational age by corrected growth curve (부당 경량아로 출생한 소아들에서 교정성장곡선을 이용한 따라잡기 성장에 대한 연구)

  • Jung, Myung Ki;Song, Ji Eun;Yang, Seung;Hwang, Il Tae;Lee, Hae Ran
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.9
    • /
    • pp.984-990
    • /
    • 2009
  • Purpose : Being small for gestational age (SGA) is a risk factor of short stature in children. Genetic background such as mid-parental height (MPH) is known to influence growth of children born SGA. We studied the relationship between growth of children born SGA and MPH and studied the effects of insulin-like growth factor (IGF-I) and insulin-like growth factor binding protein 3 (IGFBP-3) on postnatal growth in children born SGA according to MPH. Methods : Forty-nine neonates born SGA were included in this study. We defined corrected height standard deviation score (cHtSDS) by modified height SDS (HtSDS) based on their MPH. We categorized subjects into group 1 consisting of children with cHtSDS ${\geq}0$ (n=35) and group 2 consisting of children with cHtSDS <0 (n=14), and compared IGF-I and IGFBP-3 between the two groups. Results : The HtSDSs and cHtSDSs in groups 1 and 2 were $0.06{\pm}1.05$ vs. $-0.95{\pm}0.85$ (P=0.000) and $0.78{\pm}0.93$ vs. $-0.46{\pm}0.67$ (P=0.000), respectively. IGF-I SDS was higher in group 1 than in group 2 ($2.82{\pm}3.69$ vs. $0.23{\pm}2.42$, P=0.012). Total cHtSDS ($0.42{\pm}1.03$) was significantly higher than HtSDS ($-0.22{\pm}1.10$) (P=0.000). Conclusion : Our results show that cHtSDS differs significantly from HtSDS. Growth assessment by standardized growth curve does not uniformly show effects of genetic factors. A more accurate assessment of growth uses a personalized corrected growth curve that considers the genetic factor measured by MPH.

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.

  • PDF

Evaluation of Radioactivity Concentration According to Radioactivity Uptake on Image Acquisition of PET/CT 2D and 3D (PET/CT 2D와 3D 영상 획득에서 방사능 집적에 따른 방사능 농도의 평가)

  • Park, Sun-Myung;Hong, Gun-Chul;Lee, Hyuk;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.111-114
    • /
    • 2010
  • Purpose: There has been recent interest in the radioactivity uptake and image acquisition of radioactivity concentration. The degree of uptake is strongly affected by many factors containing $^{18}F$-FDG injection volume, tumor size and the density of blood glucose. Therefore, we investigated how radioactivity uptake in target influences 2D or 3D image analysis and elucidate radioactivity concentration that mediate this effect. This study will show the relationship between the radioactivity uptake and 2D,3D image acquisition on radioactivity concentration. Materials and Methods: We got image with 2D and 3D using 1994 NEMA PET phantom and GE Discovery(GE, U.S.A) STe 16 PET/CT setting the ratio of background and hot sphere's radioactivity concentration as being a standard of 1:2, 1:4, 1:8, 1:10, 1:20, and 1:30 respectively. And we set 10 minutes for CT attenuation correction and acquisition time. For the reconstruction method, we applied iteration method with twice of the iterative and twenty times subset to both 2D and 3D respectively. For analyzing the images, We set the same ROI at the center of hot sphere and the background radioactivity. We measured the radioactivity count of each part of hot sphere and background, and it was comparative analyzed. Results: The ratio of hot sphere's radioactivity density and the background radioactivity with setting ROI was 1:1.93, 1:3.86, 1:7.79, 1:8.04, 1:18.72, and 1:26.90 in 2D, and 1:1.95, 1:3.71, 1:7.10, 1:7.49, 1:15.10, and 1:23.24 in 3D. The differences of percentage were 3.50%, 3.47%, 8.12%, 8.02%, 10.58%, and 11.06% in 2D, the minimum differentiation was 3.47%, and the maximum one was 11.06%. In 3D, the difference of percentage was 3.66%, 4.80%, 8.38%, 23.92%, 23.86%, and 22.69%. Conclusion: The difference of accumulated concentrations is significantly increased following enhancement of radioactivity concentration. The change of radioactivity density in 2D image is affected by less than 3D. For those reasons, when patient is examined as follow up scan with changing the acquisition mode, scan should be conducted considering those things may affect to the quantitative analysis result and take into account these differences at reading.

  • PDF

Analysis of cytosine adenine repeat polymorphism of the IGF-I promoter gene in children with idiopathic short stature (특발성 저신장증 환자에서 IGF-I 프로모터 cytosine-adenine repeat 유전자 다형성의 분석)

  • Moon, Jae Hoon;Chung, Woo Yeong
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.3
    • /
    • pp.356-363
    • /
    • 2009
  • Purpose : A polymorphism in the IGF-I gene promoter region is known to be associated with serum IGF-I levels, birth weight, and body length, suggesting that IGF-I gene polymorphism might influence postnatal growth. The present study aimed to investigate the role of this polymorphic cytosine-adenine (CA) repeat of the IGF-I gene in children with idiopathic short stature. Methods : The study involved 131 children (72 boys and 59 girls) diagnosed with idiopathic short stature, aged 715 years. Genomic DNA was extracted from anticoagulated peripheral whole blood. The primers were designed to cover the promoter region containing the polymorphic CA repeat. Data were analyzed using GeneMapper software. The correlations between age and serum IGF-I levels were analyzed using Spearmans correlation coefficient. Results : The CA repeat sequences ranged from 15 to 22, with 19 CA repeats the most common with an allele frequency of 40.6%. Homozygous for 19 CA repeat was 13.0%, heterozygous for 19 CA repeat was 56.5%, and 19 CA non-carrier was 30.5%. The three different genotype groups showed no significant differences in height, body weight and body mass index, and serum IGF-I levels. The serum IGF-I level and age according to the IGF-I genotypes were significantly correlated in the entire group, 19 CA repeat carrier group, and the non-carrier group. The three groups also showed no significant differences in the first year responsiveness to GH treatment. Conclusion : There were no significant different correlations between 19 CA repeat polymorphism and serum IGF-I levels according to genotype. Our results suggest that the IGF-I 19 CA repeat gene polymorphism is not functional in children with idiopathic short stature.

Association of Hypercapnia in the First Week of Life with Severe Intraventricular Hemorrhage in the Ventilated Preterm Infants (기계적 환기 요법을 시행 받은 미숙아에서 고탄산혈증과 뇌실내 출혈의 발생과의 관계)

  • Kim, Jeong-Eun;Namgung, Ran;Park, Min-Soo;Park, Kook-In;Lee, Chul;Kim, Myung-Jun
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.34-43
    • /
    • 2010
  • Purpose : The aim of this study was to examine whether hypercapnia during the first seven days of life was associated with severe intraventricular hemorrhage (IVH) in preterm infants requiring mechanical ventilation. Methods : A matched pair analysis was performed for 19 preterm infants with severe IVH(grade$\geq$3) and 38 infants with no severe IVH (normal or grade 1), who required mechanical ventilation for more than seven days. The univariate and multivariate analysis of severe IVH with maximal and minimal $PaCO_2$, averag $PaCO_2$, SD of $PaCO_2$, and difference in the $PaCO_2$ were assessed. The major perinatal factors and maximal ventilator index (VI) were also compared. Results : Infants with severe IVH had a higher maximal $PaCO_2$ (86.1$\pm$18.4 mmHg vs. 60.1$\pm$ 11.6 mmHg, P <0.001) and mean $PaCO_2$ (47.5$\pm$5.6 mmHg vs. 41.2$\pm$6.3 mmHg, P=0.004) and a larger SD or difference in $PaCO_2$ (14.0$\pm$4.4 mmHg vs. 9.0$\pm$2.4 mmHg; 60.3$\pm$20.9 mmHg vs. 35.5$\pm$11.8 mmHg, P <0.001). However the minimal $PaCO_2$ values did not differ between the groups. Disseminated intravascular coagulation, pulmonary hemorrhage, and the air leak syndrome were more frequent in the IVH group than in the controls. The maximal VI on each day was higher in the IVH group. The multivariate logistic regression analysis after controlling for bleeding tendency showed that the air leak syndrome, maximal VI, and maximal $PaCO_2$ were independently associated with severe IVH [OR, 1.324 (95% CI, 1.011-1.733; P=0.041)]. Conclusion : Extreme hypercapnia was significantly associated with severe IVH in preterm infants, after adjustment for major perinatal risk factors. Frequent monitoring of the $PaCO_2$ may be important for early detection of inadvertent hypercapnia and prompt correction of high PaCOS levels.

Interaction of Rifampin and Warfarin (리팜핀이 와파린의 항응고 효과에 미치는 영향)

  • Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.768-774
    • /
    • 1999
  • Background: It is well known that rifampin decreases the hypoprothrombinemic effect of warfarin by induction of cytochrome P-450 enzyme in healthy volunteer. However, in patients the dosage schedule of warfarin during rifampin therapy is not established. Therefore, patients taking both rifampin and warfarin were reviewed to find out the adequate dosage schedule of warfarin in addition to side effects by interaction of two drugs. Method: Patients taking both rifampin and warfarin were retrieved from patients who were admitted due to heart disease and tuberculosis at Boochun Sejong Hospital from January of 1995 to August of 1999. To decide the adequate dosage of warfarin, the dosage of warfarin before, during, and after rifampin was evaluated in patients who kept adequate hypoprothrombinemic effect of warfarin during rifampin. To decide the adequate dosage schedule of warfarin, the time interval from the beginning of rifampin to normalization of prothrombin time(INR$\geq$1.1) was evaluated. And, the side effects by interaction of two drugs were reviewed. Results: All 12 patients taking both rifampin and warfarin were retrieved. Among them only 6 kept adequate hypoprothrombinemic effect of warfarin during rifampin. The dosage of warfarin during rifampin was $2.4{\pm}0.6$(mean$\pm$standard deviation) times as much as that before rifampin but the dosage after rifampin was the same as that before rifampin. The time interval from the beginning of rifampin to normalization of prothrombin time was $5.8{\pm}2.9$(mean${\pm}$standard deviation) days. 2 out of 12 had complication related to the interaction of rifampin and warfarin, one cerebral embolism just after the beginning of rifampin and the other cerebral hemorrhage just after the discontinuation of rifampin. Conclusion: When both rifampin and warfarin are prescribed, it would be a possible method to be confirmed by prospective study that warfarin be gradually increased about 2 times more than that without rifampin over 1 week or so after the beginning of rifampin and be tapered to the same dosage as that before rifampin when rifampin is discontinued. And, it would be prudent that prothrombin time be monitored frequently during rifampin and warfarin therapy, especially the beginning or discontinuation of rifampin.

  • PDF