• Title/Summary/Keyword: 표준측정법

Search Result 870, Processing Time 0.026 seconds

A Study on Creating Refrence Pattern of Korean Digits by using the Clustering (집단화를 이용한 한국어 숫자음성의 표준 패턴 설정에 관한 연구)

  • 김계국
    • The Journal of the Acoustical Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.3-12
    • /
    • 1986
  • 본 논문은 불특정 화자의 음성을 인식시키기 위하여 한국어 150 숫자음에 대하여 10개의 표준 패턴을 설정하는데 목적을 두고 연구하였다. 남성 화자 3인이 각 숫자음을 5번씩 반복 발음한 150숫자 음을 집단화 하여 표준 패턴을 설정하였다. 특징 피라미터는 포르만트 주파수를 이용하였고 유크리드 거리 측정법을 유사도 비교에 사용하였다. 실험 결과는 85.3%의 인식율을 얻었다.

  • PDF

Antenna Gain Measurement in Time Domain (시간 영역에서 안테나 이득 측정 연구)

  • Park, Jungkuy;Kim, Woo-Nyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.11
    • /
    • pp.1217-1227
    • /
    • 2012
  • There are several antenna calibration methods, so-called 3-Antenna Method, Standard Site Method, and Standard Antenna Method which measure the antenna gains or antenna factors. These methods yield the free space or quasi free space antenna gains in only the frequency domain. In this paper, an antenna calibration method using the time domain in the open area test site is discussed. The reflected waves due to the ground are traced in the time domain. After they are removed by the time gating function of network analyzer, the free space transmission coefficient $S_{21}$ is extracted. Such a way is applied to the broad band horn antenna ranging 1 GHz to 18 GHz, and the free space gains are obtained by Friis transmission equation. The method is checked by Standard Site Method in open area test site. The results show comparatively good agreement except for 18 GHz.

Studies on the Standardization of pH Measurement System (pH 측정 시스템의 표준화에 관한 연구)

  • Lee, Hwa Shim;Kim, Myung Soo;Kim, Jin Bok;Oh, Sang Hyup
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.4
    • /
    • pp.432-442
    • /
    • 1998
  • Since the definition of pH, $pH=-Ioga_H$ is based on a single ion activity, pH values can not be determined with measurement itself, but require an approximation method. They are derived from EMF measurement of a liquid junction free cell using hydrogen and Ag/AgCl electrodes. Primary standard materials with certified pH values can be obtained with this approximation method. Standard buffer solutions are used to calibrate pH meters. Thus the accuracy of the pH values of standard buffer solutions limits the reliability of measured pH values can be obtained with this approximation method. Standard buffer solution are used to calibrate pH meters. Thus the accuracy of the pH values of standard buffer solutions limits the reliability of measured pH values of sample solutions. To certify the pH values, we have established the system for the primary standard measurement and certified the pH of buffer solutions in the range of 1.6∼12.5 pH unit within uncertainty of ${\pm}0.005$ pH unit.

  • PDF

Simultaneous Determination of Vitamin A and E in Infant Formula by Rapid Extraction and HPLC with Photodiode Array Detection (신속추출법 및 PDA-HPLC에 의한 조제분유 중 비타민 A, E의 동시분석)

  • Kwak, Byung-Man;Lee, Ki-Woong;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.189-195
    • /
    • 2004
  • Rapid and simple method was developed for simultaneous determination of vitamins A and E contents in infant formula. Vitamins A and E were extracted by PDA-HPLC with reversed phase column using organic solvent, and their contents in Certified Reference Material (CRM) and infant formula were determined and compared with results of Food Standards Codex and AOAC method for evaluation of developed method, Vitamins A and E contents in CRM determined by developed method were within certified range of standard values. Developed method has great advantages of simple and rapid sample preparation and simultaneous determination of vitamins A and E by PDA-HPLC using reversed phase column.

Development of Tractor Roll-Over Test Method for ISO Revision (ISO 국제표준 제안을 위한 트랙터 전복 안전도 시험방법)

  • Ryu, Dong Soo;Baek, Seung Hoon;Kim, Myoung Ho;Kim, Seong Min
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.68-68
    • /
    • 2017
  • 농작업 시에 가장 빈번하게 일어나는 위험한 농기계 관련 사고는 전도사고로 트랙터의 전복이 꼽히고 있다. 따라서 트랙터의 전복을 유발하는 주원인인 무게중심의 측정이 중요시 되고 있다. 지금까지 사용해 왔던 북미와 유럽, 일본 등의 선진 농기계 업체들이 사용하고 있는 트랙터 무게중심 측정방법(ISO 789-6 : OECD code2, 작도법)은 정밀성과 신뢰성이 다소 결여되어 이를 정확히 측정하기 위한 새로운 방법 및 알고리즘의 개발이 시급한 상황이다. 따라서 본 연구에서는 트랙터 무게 중심을 보다 정확히 측정할 수 있는 방법을 개발하고 이를 ISO에 NP(New Proposal)제안 과정을 거쳐 ISO 개정을 위한 기초연구로 수행되었다. 트랙터 무게중심 측정을 위한 ISO 789-6의 경우 작도법으로 시험하도록 되어 있으나, 본 연구에서는 무게중심을 계산할 수 있는 프로그램을 개발하고, 극좌표계산방식으로 측정된 값을 프로그램에 직접 입력하는 방법을 개발하여 신뢰성과 정밀성을 높일 수 있도록 하였다. 프로그램의 개발은 ISO(OECD) 방법에 대해 계산식을 개발하고 4개의 좌표가 교차하는 좌표와, 트랙터 후방을 들어 올렸을 때의 끝점 좌표, 전방을 들어 올렸을 때의 끝점 좌표 등을 구하는 자동 알고리즘을 개발하고, 중심 위치는 시험방법 및 트랙터의 제원에 따른 치수와 중량 데이터를 측정하여 입력하면 자동으로 계산이 되도록 하였다. 본 연구에서 개발한 방법과 기존 ISO 789-6(작도법)을 비교한 결과 보다 신뢰성 있는 결과를 얻을 수 있었으며, 이를 ISO에 NP제안을 위한 합리적인 시험방법임을 알 수 있었다. 개정작업이 완료될 시에 이 방법을 농기계 업체에 보급함으로써 보다 안전한 농기계 설계 및 제작에 기여하고 농민의 안전사고 예방에 기여할 수 있을 것이다.

  • PDF

Development and validation of an analytical method for the determination of lepimectin residues by HPLC-PDA (HPLC-PDA를 이용한 lepimectin 잔류량 분석법 개발 및 확인)

  • Do, Jung-Ah;Kwon, Ji-Eun;Kim, Mi-Ra;Lee, Eun-Mi;Kuk, Ju-Hee;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.142-153
    • /
    • 2013
  • A new, rapid, and simple analytical method was developed and validated using high performance liquid chromatograph-photodiode array detector (HPLC-PAD) for the determination of lepimectin residues in agricultural commodities. The lepimectin residues in samples were extracted with methanol, partitioned with dichloromethane, and then purified with glass column filled with subsequently to aminopropyl ($NH_2$) solid phase extraction (SPE) cartridge. The purified samples were detected using HPLC-PAD. Correlation coefficient ($R^2$) of both lepimectin $A_3$ and $A_4$ solutions were 0.9999. The method was validated using cucumber spiked with lepimectin at 0.02 and 0.2 mg/kg and pepper, mandarin, hulled rice, potato, soybean at 0.02 and 0.5 mg/kg. Average recoveries were 76.0~114.8% with relative standard deviation less than 10%, and limit of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.01 mg/kg, respectively. The result of recoveries and overall coefficient of variation of a laboratory results in Gwangju regional KFDA and Daejeon regional KFDA was followed with Codex guideline (CAC/GL 40). Therefore, developed method in this study is accurate, rapid, and appropriate for lepimectin determination and will be used to keep safety of lepimectin residues in agricultural products.

Trends in Balance Parameters and the Measuring Method of Circuit Balance in Telecommunication Lines (세계 각국의 평형도 관련 파라미터 조사분석 및 가입자선로의 회선평형도 평가방법)

  • Koo, B.H.;Kim, Y.T.;Sohn, H.;Song, S.J.
    • Electronics and Telecommunications Trends
    • /
    • v.8 no.4
    • /
    • pp.111-129
    • /
    • 1993
  • 본 고에서는 가입자 통신 선로의 평형화의 필요성을 선로에 유기되는 유도 잡음과 관련하여 서술하였다. 또한, 세계 각국의 표준기관에서 권고하고 있는 평형도 관련 측정 파라미터와 그 측정법을 조사 분석하였다. 또한 포설된 가입자 선로의 평형도 평가법을 제시하였으며, 현장측정을 통해 본 방법의 타당성을 입증하였다. 본 고에서는 제시된 가입자 선로의 평형도 평가법은 우리나라 기술기준의 일환인 회선 평형도의 평가법으로 적용 가능할 것으로 기대된다.

Improvement method for viscosity measurement of high viscosity paper and fabric cultural heritages (고점도 지류 및 섬유 문화재의 점도 측정 개선 방법 연구)

  • Kim, Young-Hee;Hong, Jin-Young;Jo, Chang-Wook;Kim, Soo Ji;Lee, Jeung-Min;Seo, Min Seok;Choi, Kyoung Hwa
    • 보존과학연구
    • /
    • s.34
    • /
    • pp.20-29
    • /
    • 2013
  • Paper, textile and wood materials are mainly consisted of cellulose. Cellulose is high molecule and make up the strong crystalline structure by hydrogen bonds. In particular, the polymerization degree of cellulose are closely related to the strength of fiber, and the permanence. the useful life of fiber, also depends on the degradation of this substance. The viscosity of cellulose is considered to be an important indicator of fiber damage in high molecule polymers. The viscosity measurements with CED solution is used to measure the molecular weight and the degree of polymerization of cellulose. Cellulose viscosity of wood fibers is measured with TAPPI standard method T230. However, TAPPI standard method T230 is difficult to completely dissolving the cellulose of high molecular weight and large degree of polymerization, such as Korea traditional papers and fabrics made with mulberry, ramie, cotton fibers. In this study, The high viscosity of hanji and fabric was measured with TAPPI standard method T254. T254 method is that the cellulose specimen with the proper amount of weaker (0.167M CED) solution, and completely dissolved with the stronger (1.0M CED) solution. It was found that cellulose with high degree of polymerization was dissolved more easily in general CED method.

  • PDF

M.S.D. 기법에 의한 작업측정

  • 이강종
    • Journal of the Ergonomics Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.25-27
    • /
    • 1983
  • 당사는 부산에 위치한 각종 소화기 및 자동차부품 생산업체로서, 1972년 우리나라 중요 방위산업체의 하나로 발족하였다. 공장 발족 당시 공장의 배치 및 관리기술을 미국에서 도입하였기 때문에, 작업관리면에서도 I.E. 기법들이 적용되어 생산성 향상에 많은 성과가 있었다. 작업측정이 란 작업자가 행하는 여러가지 활동을 시간을 매체로 하여 측정하는 것으로서 작업 및 관리의 과학화 에 필요한 자료를 얻고자 하는 것인데, 그 주요 목적은 표준시간의 설정에 있다. 이러한 작업측정 은 크게 스톱 워치(stop watch)나 촬영에 의한 직접 측정방법인 시간연구법과 PTS (Predetermined Time Standards)법으로 나눌 수 있다.

  • PDF

Accurate Measurement of the Thermal Conductivity of Electronic Materials Using the Flash Method (섬광법을 이용한 전자재료의 열전도율 정밀측정)

  • Kim, Seog-Kwang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.9-9
    • /
    • 2008
  • 일반적으로 섬광법으로 열전도율을 구하기 위해서는 섬광법으로 열확산계수를 측정하고, 시차주사열량계(Differential Scanning Calorimetry, DSC)로 비열측정을 하며 아르키메데스의 원리를 이용한 용적밀도를 구하여 이들 각각의 값을 사용하여 열전도율을 얻는다. 따라서 열전도율을 정밀하게 측정하기 위해서는 이 세 가지 물성치를 측정할 때 수반되는 오차요인을 종합적으로 검토하여 개선하는 것이 매우 중요하다. 섬광법으로 열확산계수를 측정할 때 시료의 전면에 조사되는 빛의 흡수율을 향상시키고 배면에서의 온도상승의 감지를 증대할 목적으로 시료 양면에 흑연코팅을 하게 된다. 이때 코팅된 흑연이 시료에 부가적으로 열저항을 증가시켜서 열확산계수를 측정하는데 가장 큰 오차요인이 되고 있다. 한편 비열은 대부분 DSC로 측정하는데, 시료와 용기의 열접촉 정도에 따라 큰 오차요인이 되기도 한다. 본 연구에서는 열확산계수를 정밀하게 측정하기 위해서 시료에 부가적인 열저항으로 작용하는 흑연코팅의 두께와 시료배면에서의 온도상승곡선 간의 상관관계를 실험식으로 도출하였으며 이방법은 열확산계수를 정밀하게 측정하는데 매우 유효한 방법임이 입증되었다. 또한 DSC의 접촉에서의 문제점을 해결하기 위해서 시료배면에서의 무차원 시간축(t/$t_{max}$)을 도입하였으며. 무차원 시간축에 따른 온도상승 곡선에서 표준시료와 측정시료의 half time($t_{1/2}$)의 0.5 배와 1.5배 사이 구간을 적분한 뒤 비교하여 열량계산으로부터 비열을 구하는 방법을 새롭게 개발하였으며 기존의 DSC에 비하여 정밀도를 향상시킬 수 있었다. 결론적으로 새롭게 제안된 측정기법들은 열확산계수 및 비열 혹정 시의 근본적인 오차요인을 혁신적으로 해결함으로써 정밀하고 신뢰성 있는 열전도율을 측정할 수 있음을 입증할 수 있었다.

  • PDF