• Title/Summary/Keyword: 표준입자, SRM

Search Result 8, Processing Time 0.023 seconds

Calibration and Uncertainty Measurement of Differential Mobility Analyzer Using 100 nm NIST SRM 1963 (100 nm NIST 표준입자를 이용한 미분형 전기 이동도 분석기의 교정 및 불확실도 측정)

  • Lee, Snag-Jin;Ahn, Jin-Hong;Ahn, Kang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1766-1771
    • /
    • 2003
  • House made differential mobility analyzer(DMA) is calibrated with NIST SRM 1691(300 nm PSL). Then the particle size and uncertainty for differential mobility analyzer(DMA) using the NIST SRM 1963(100 nm PSL). In result, calibration of prototype DMA is measured using 300 nm NIST SRM 1691, then sheath air flow was corrected 126.67 ㎤/s. Corrected sheath air flow is used in uncertainty measurement of prototype DMA. Uncertainty analysis is performed using NIST SRM 1963(100 nm PSL). The experimental result shows that NIST SRM 1963 is measured as 102.17 nm with a type A uncertainty of 0.33 nm.

Uncertainty improvement in measurement of mean diameter of 0.3-$\mu\textrm{m}$-diameter polystyrene sphere by using quasi-elastic light scattering (준탄성광산란을 이용한 0.3 $\mu\textrm{m}$ 폴리스티렌구의 평균지름 측정 불확도 향상)

  • 박병천;정명세
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.258-263
    • /
    • 1998
  • Quasi-elastic light scattering is utilized to measure the mean diameter of the 0.3 $\mu\textrm{m}$-dimeter polystyrene sphere. The mean diameter of the polystyrene sphere is required to be known within the uncertainty of a few per centages. The systematic error has been considerably reduced by improving the system for the angle alignment and temperature measurement of cell. NIST SRM 1691 (0.269$\pm$0.007 $\mu\textrm{m}$: TEM; 0.275$\pm$0.007 $\mu\textrm{m}$: QELS) is measured to be 0.273 $\mu\textrm{m}$$\pm$0.006 $\mu\textrm{m}$ in mean diameter. Detailed description is given of the improved method and the resultant uncertainty, and the comparison of results with NIST is followed.

  • PDF

Improvement of size measurement polystyrene spheres of diameters 3$\mu$m and 10$\mu$m by optical microscope with CCD camera (CCD 카메라가 장착된 광학현미경을 사용한 폴리스티렌구 (3 $\mu$m와 10 $\mu$m)의 평균지름측정)

  • 정기영;박병천;깅주식;송원영;오범환
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.362-367
    • /
    • 1998
  • Center Distance Finding (CDF) is a technique to find the sphere diameter by measuring the distance between two contacting spheres. The focal spots of the sphere clusters are formed in the back-focal plane by the transmission-mode optical microscope with the pseudothermal illumination source. Digital images taken by the CCD camera were processed by the software called Global Lab Image. The centers of the focal spots are found and the spot positions are expressed in terms of the CCD pixel elements, whose coordinate are calibrated by a heterodyne interferometer. The new CDF measurement system has been developed, which are more advantageous in time and convenience than the existing system, while the measurement uncertainly remains sufficient for its use as a magnification standard for optical microscopy. Two kinds of polystyrene spheres whose nominal diameters 3 and 10 $\mu\textrm{m}$ (NIST SRM 1962 and 1960) are measured with the uncertainly less than 1% at the confidence level of 99%, and the results are compared with the results of National Institute of Standards and Technology.

  • PDF

Determination of Metallic Elements in Urban Particulate Matter (SRM 1648) by ICP-MS and AAS (ICP-MS와 AAS를 이용한 대기 입자상 표준물질 (SRM 1648) 금속성분의 정량에 관한 연구)

  • Yoo Su-Young;Choi Kum-Chan;Kim Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.423-430
    • /
    • 2005
  • This study was investigated with sample digestion techniques and a reliability of the analytical results for a quantitative analysis of a standard reference material ('urban particulate matter', SRM 1648). The metallic elements were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) with closed vessel microwave acid digestion method and atomic absorption spectroscopy (AAS). Quality control of the overall analytical procedures for metallic element determinations of standard reference material were estimated by analysis of a SRM 1648. Three digestion solutions $(type\;1:\;HNO_3,\;type\;2:\;HNO_3\;and\;H2O_2(4'1)\;mixture,\;type\;3:5.55\%\; HNO_3\;and\;16.75\%\;HCI\;mixture)$ were applied to SRM 1648. As a result, three digestion solutions used in this study are completely unable to digest Cr of SRM 1648. Reliability of Cr and As showed some errors in the digestion with digestion solution type (3) due to the influence of chlorides. Type (3) digestion solutions are sufficient to fulfill the digestion of As as well as Se in SRM 1648. ICP-MS results showed the improvement in accurate and precise determination of some trace elements like Cd, V and Pb in SRM 1648. It is important to use the proper digestion solution for each element to qualify analytical precision.

Intercomparison and Determination of Trace Elements in Urban Dust by Neutron Activation Analysis (중성자방사화분석법을 이용한 대기분진중의 미량원소 비교분석)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Kim, Sun-Ha;Park, Kwang-Won;Kang, Sang-Hun
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.179-188
    • /
    • 2000
  • Trace elements in air samples artificially loaded on filters with urban dust and the bulk material of urban dust as an environmental sample were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Dust, SRM 1648) of the National Institute of Standard and Technology was used for the analytical quality control. The relative error for 37 elements was less than 15% and the standard deviation was less than 10%. 29 elements in the urban dust and 21 elements in the loaded filter sample were determined respectively. To evaluate the proficiency and reliability of the measurement, data intercomparison was performed and 39 analytical laboratories participated in the analysis using different analytical methods; neutron activation analysis, particle induced X-ray emission analysis, X-ray fluorescence analysis and atomic absorption spectrometry. Z-scores were calculated using the standard deviation of the laboratorie's mean as target standard deviation, and a good result was obtained that the values fall between -1 and +1 except some elements.

  • PDF

Quality Control on Neutron Activation Analysis for Urban Dust by the Proficiency Test (비교숙련도 시험을 통한 도시대기분진에 대한 중성자방사화분석법의 품질관리)

  • Moon, Jong-Hwa;Kim, Sun-Ha;Chung, Yong-Sam
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.433-438
    • /
    • 2002
  • Trace elements in two air filters (V-50, P-50) artificially loaded with urban dust provided from IAEA were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Particulate Matter, SRM 1648) of National Institute of Standard and Technology was used for analytical quality control. About 20 elements in both of loaded filter samples were determined. To evaluate inter-laboratory comparison and proficiency test, analytical data were statistically treated with the results which collected from 49 laboratories, 40 countries participated in this study using neutron activation analysis, particle induced X-ray emission, inductively coupled plasma mass spectroscopy, etc,. From the results of statistical treatment, Z-scores are within ${\pm}2$. Furthermore, accuracy and precision of obtained analytical values are passed according to the criteria of the proficiency test. Consequently, it was proved that analytical quality for air dust samples being performed has been controlled properly.

Distribution Characteristics of Platinum Group Elements in Roadside Dust from Daejeon, Korea (대전 도로변 먼지내 Platinum Group Elements의 분포 특성)

  • Lim, Jong-Myoung;Jeong, Jin-Hee;Lee, Jin-Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.5
    • /
    • pp.405-416
    • /
    • 2018
  • In this research, the distribution of Platinum Group Elements (PGEs) at roadside dust in Daejeon, Korea was examined using an ICP-MS (Inductively Coupled Plasma-Mass Spectrometry) technique. For the quality assurance of the determination, method validation based on its accuracy and precision was conducted using SRM (Standard Reference Material). It was found that the relative errors of Pt, Pd, and Rh against each SRM value were -0.7%, -10.0%, and -20.4%, respectively, while relative standard deviations for three elements were less than 10%. The concentrations of Pt, Pd and Rh in roadside dust averaged as $17.4{\pm}9.2{\mu}g/kg$, $283.6{\pm}20.5{\mu}g/kg$, and $7.3{\pm}2.8{\mu}g/kg$, respectively. The concentrations of Pt and Rh have significantly higher distribution patterns in the dust at roadside and underground parking lot than those in soil of the background or other urban area. The correlation analysis between concentrations of PGEs in roadside dust indicates that the distribution of Pt and Rh concentration were strongly affected by automobile sources.

Absolute Age Determination of Gangmun-dong Sites Gangneung, Gangwon-Do-Radiocarbon and Thermoluminescence Dating - (강릉 강문동 유적의 절대연대측정 - 방사성탄소연대 및 열발광연대 -)

  • Kang, Hyung-Tae;Chung, Kwang-Yong
    • Journal of Conservation Science
    • /
    • v.18 s.18
    • /
    • pp.97-104
    • /
    • 2006
  • Absolute ages for three pieces of organic materials such as wood and shell were determined with radio-carbon concentrations and two potsherds with thermoluminescence measurements. Radiocarbon contents of each sample were compared with those of modern standard oxalate(NBS SRM4990C) and calculated radiocarbon ages of them. Quartz grains with diameter of $90\sim150{\mu}m$ were extracted from potsherds and used for measuring the archaeodose. Annual dose were calculated with measuring the alpha count rates and water contents and analysing $K_2O$ concentration of both potsherds and soils. Radiocarbon ages of organic materials were in the ranges of $4\sim2C$ BC and Quartz grain techniques for thermoluminescence dating showed 170 BC ud 210 BC respectively. It was found that the results of radiocarbon dating and TL dating were accorded with each other. But the deviations of TL dating have shown 13% and 20% respectively. It need to reduce the deviations.

  • PDF