• Title/Summary/Keyword: 표준시험조건에서의 성능

Search Result 65, Processing Time 0.029 seconds

Statistical Test for Performance Evaluation of Code Carrier Divergence Detection at a GBAS Reference Station (GBAS 기준국의 코드 반송파 발산 검출성능 평가를 위한 통계시험)

  • Yun, Young-Sun;Kim, Joo-Kyoung;Cho, Jeong-Ho;Heo, Moon-Beom;Nam, Gi-Wook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.9
    • /
    • pp.760-770
    • /
    • 2012
  • In order to provide precision approach service based on GBAS, air navigation service providers should validate the GBAS system performance against international standard requirements and receive approval. The GBAS manufacturer should define integrity threat, analyze the integrity monitors and evaluate performance of the implemented monitors to verify integrity performance which is critical to the aircraft safety. This paper describes a statistical test result to evaluate performance of the code carrier divergence monitors implemented in KARI Integrity Monitor System software. The paper introduces analysis and test procedure which is developed for the performance evaluation and describes the analysis, the test scenario generation and the test results. The results show that the implemented monitors can detect the expected minimum detectable errors with satisfying the probability of missed detection requirements.

저가의 EMI/EMS 측정 시스템 - 표준, 개량형 TEM Cell

  • 윤재훈;이애경
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.1
    • /
    • pp.51-58
    • /
    • 1993
  • 일반적으로 EMI 측정시험장으로 활용되고 있는 시설로서는 야외 시험장(open site)과 전자파 무반사실 (anechoic chamber)이 있다. 전자의 경우는 전자파 간섭 영향이 없어야 하고 반사 또는 커플링의 영향을 줄 수 있 는 장애물이 없어야 하는 시험환경 조건이 요구되지만, 근래의 전자기기 사용증가, 방송, 무선 통신시스템의 다양화 및 산업의 복잡화에 따른 인공잡음의 증대로 그 선정이 극히 어려워 도시에서 멀리 떨어진 곳, 즉 연구 개발 및 제품 생산 소재지로 부터 멀리 떨어진 곳에서나 가능하게 되었으며, 그외에도 기상조건에 의한 영향 및 주변 개발에 의한 잡음 환경의 변화로 성능 보존이 어렵다. 후자의 경우는 야외 시험장의 전자파 환경 문제점을 피할 수 있어, 도시나 혹은 제품 생산지 가까이에 설치 운용이 가능하나 이들 모두 수억에서 십수억원에 이르는 설치 비용이 들어 중소 업체에서 보유하기가 어렵다. 또한 안테나 를 송수신원으로 사용하므로서 저주파수대 측정이 어려울 뿐만 아니라 피시험체주변 공간(반경 3, 10M)에서의 1점 측정 방식으로 인해 측정시간이 많이 소요되는 기술적인 문제점을 지니고 있다.

  • PDF

Study on Development of a Carton Box for Cold-chain Distribution of Oyster mushroom(Pleurotus ostreatus) (느타리 버섯의 저온유통용 포장상자 개발에 관한 연구)

  • Lee, W. O.;Yun, H. S.;Lee, H. D.;Chung, H.;Cho, K. H.;Kim, M. S.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.311-316
    • /
    • 2002
  • 느타리버섯의 포장상자를 예냉·저온유통에 적합한 구조로 개선하기 위하여 4kg용 골판지상자를 T11형 표준 팔레트에 적재율이 96%이상 되게 제작하여 고습조건에서도 안전하게 느타리버섯을 보호할 수 있는 상자구조를 찾기 위한 수직압축강도시험과 냉각성능 및 예냉후 저온저장 중 품질변화에 대한 시험을 실시하였다. 시험결과 4kg 접음식 상자에서 내 포장상자를 사용할 경우 고습조건에서 안전압축강도를 유지할 수 일었으며, 브릿스형 상자에 비하여 경제적으로 제작할 수 있고, 또한 홈판형 상자에 비하여 냉각속도를 단축하고 균일한 냉각을 할 수 있어 느타리 버섯의 품질유지에 유리한 것으로 나타났고, 기존 유통되는 상자을 사용할 때 보다 유통기간을 4∼5일정도 연장시킬 수 있는 것으로 나타났다.

  • PDF

TTA 시험$\cdot$인증 서비스 - 이동통신 분야 -

  • 김순용;정인명
    • TTA Journal
    • /
    • s.88
    • /
    • pp.149-153
    • /
    • 2003
  • TTA(한국정보통신기술협회)는 2003년 7월 9일 A사(보안요청에 따라 업체명은 명기하지 않음)의 CDMA 2000 휴대폰에 대하여 여러 환경 조건에서 전기적인 특성 시험을 수행하여 국내에서 최초로 휴대폰 시험분야에서 TTA Certified 인증서(번호 : TTA-C-M-03-001)를 발급하였다. TTA는 A사의 CDMA 2000 휴대폰에 대한 전기적인 특성 시험을 위해 3GPP2에서 제정한 C.S0011A 표준을 준수한 TTA Certified 인증기준에 따라 32개의 시험항목을 측정하였다. 본 고에서는 IS-98 및 IS-898 장비와 연동하여 그 기능이 TTA Certified 인증기준에 따라 모두 정상적으로 동작하는지 확인하고, CDMA 이동전화 단말기의 최소성능에 관한 상온$\cdot$상습 환경, 온도 및 전압변화 환경, 고습 환경, 진동 환경, 충격 환경을 측정하여 이에 대한 시험결과를 소개한다.

  • PDF

Performance Based Design for High Curability Concrete (성능중심형 고내구성 콘크리트의 배합설계)

  • Kim, S.S.;Park, K.P.;Lee, J.B.
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.969-974
    • /
    • 2008
  • This study was carried out to investigate the service life of reinforced concrete structures for durability design. The service life has three aspects physical service life, functional service life, and social service life, and that a structures are normally demolished to end its service life when either the functional or social service life is over before the physical service life comes to end an end. In the future, it is very important that durability design shall be performed establishing design service life and the unallowable state of deterioration in the course of design service life.

  • PDF

Improvement of Fire Resistance for Timber Framed Walls by Reinforcement of Heavy Timber Frame

  • Park, Joo-Saeng;Hwang, Kweon-Hwan;Kim, Kwang-Mo
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.6
    • /
    • pp.469-478
    • /
    • 2010
  • Fire resistance of new hybrid timber framed wall systems was evaluated in this study. These wall systems are composed of two major structural parts. One part is a heavy timber frame part designed to take charge of whole vertical load using heavy timber post and beam, and the other is an infill wall structure, designed to take charge of whole horizontal load and to provide an established level of fire resistance. A basic concept of this hybrid wall is adopted from a typical furniture structure with frame. A timber post and beam frame is constructed with Japanese Larch solid timber post(180mm by 180mm) and beam(180mm by 240mm). As infill wall systems, two types of walls are applied. One is a typical light timber framed wall with solid blocking and another is a structural insulated panel wall, in which polystyrene insulation is filled between two structural panels to make single structure. For all tested walls, two layers of 12.5mm thick type-X gypsum boards are used on fire exposed side. Prior to tests for hybrid walls, only infill walls are tested without heavy timber frame. All fire resistance tests are carried out in accordance with KS F 2257, and temperatures on several points within wall structure and unexposed wall surface are measured during fire tests. It is considered that the reinforcement of heavy timber frame is significantly efficient for improving the fire resistance of timber framed walls.

  • PDF

The Study on Evaluation Method of Pest Control Robot Requirements for Smart Greenhouse (스마트 온실 방제 로봇의 요구조건을 고려한 평가 방법 연구)

  • Kim, Kyoung-Chul;Ryuh, Beom-Sahng;Lee, Siyoung;Kim, Gookhwan;Lee, Meonghun;Hong, Young-ki;Kim, Hyunjong;Yu, Byeong-Kee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.318-325
    • /
    • 2019
  • Recently, research and development on agricultural robots have been on the rise as the interest in smart farming has increased. Robots used in smart greenhouses should be taken into account with the working characteristics and growing environment. This study examined cleaning robots developed through the environmental analysis of smart greenhouses. This study assessed the evaluation method considering the requirements of the pest control robot applicable to the smart greenhouse. The performance and quality assessment criteria were established to conduct tests through the requirements of robots. The required functions and goals of the pest control robot were derived by referring to the robot-related standards. A driving and working ability test was conducted to assess the performance of the robot. The driving test was conducted on the driving performance of the robot and the work capability was tested on the pest control performance. In addition, a durability test was conducted to assess the quality of the robot. The required factors for smart greenhouse robots were derived from the test results. The study results are expected be a standard for an evaluation of a variety of robots for applications to smart greenhouses.

Analysis of Structural Stability and Optical Performance for Optical Equipment During In-flight Vibration (항공기 진동에 대한 광학 탑재 장비 구조 안정성 및 광학 성능 분석)

  • Jo, Mun Shin;Kim, Sang Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.897-904
    • /
    • 2017
  • Optical equipment consists of various components, and a detector is mounted and operated on aircraft, tanks, and warships for target detection and classification. The structural stability and optical performance of aeronautical optical equipment operated at several kilometers of altitude are degraded owing to vibration generated in the aircraft. It is necessary to verify the structural stability and optical performance requirements of the equipment in vibration environment conditions during the design phase. In this study, vibration environment conditions were analyzed using a test standard and the measurements of the vibration generated in aircraft. The conditions were classified as endurance and operating vibration conditions for structural stability and optical performance verification, respectively. The structural stability was verified according to natural frequency analysis, response analysis for the endurance vibration condition, and static analysis. The optical performance was verified by applying the vibration response analysis results to the optical design/analysis program.

Full Rig Test and High Altitude Ignition Test of Micro Turbojet Engine Combustor (초소형 터보제트엔진 연소기의 리그시험 및 고고도 점화시험)

  • Lee, Dong-Hun;Kim, Hyung-Mo;Park, Poo-Min;You, Gyung-Won;Paeng, Ki-Suk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.373-376
    • /
    • 2009
  • A full rig combustor test and altitude ignition test were carried out for radial-annular combustor of micro turbojet engine. 11.2% total pressure loss and 99.85% of combustion efficiency were measured at design point of engine under sea level standard condition and $2{\sim}6$ of air excess ratio for ignition envelope was achieved on engine starting regime. Finally, A 30,000 ft high altitude ignition test was also performed and finally we found out that the developed radial-annular combustor is appropriate to micro turbojet engine.

  • PDF

An Experimental Study on the Seawater Resistance of Steel Fiber Reinforced concrete Using Fly Ash (플라이애쉬를 혼입한 강섬유보강콘크리트의 내해수성에 관한 실험적 연구)

  • 박승범;오광진
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.3
    • /
    • pp.189-197
    • /
    • 1997
  • This paper describes an experimental study on the seawater resistance of steel fiber reinforced concrete. The test methods adopted for this study are divided into long-term immersion test and acceleration test by wetting and drying. Tests were carried out to evaluate the procedures which were measured for nine months about reduction in dynamic modulus, length change and compressive strength. Resistance indicators are the water-cement ratio, the content of steel fiber, the content of fly ash, the immersion water(artificial seawater or freshwater) and the types of curing. The seawater resistance of the appropriate additions of steel fiber and fly ash have apparently increased.