• Title/Summary/Keyword: 표면피막

Search Result 531, Processing Time 0.034 seconds

Removal Torque of Mg-ion Implanted Clinical Implants with Plasma Source Ion Implantation Method (마그네슘 이온주입 임플란트의 뒤틀림 제거력에 관한 연구)

  • Kim, Bo-Hyoun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.41-52
    • /
    • 2009
  • The surface treatment of titanium implant could bring out the biochemical bonding between bone and implant. The purpose of this study was to evaluate the biomechanical bone response of Mg-ion implanted implants with plasma source ion implantation method. Twelve New Zealand white rabbits were included in this study. Each rabbit received one control fixture (blasted with resorbable blasting media, RBM) and three types of Mg ion implanted fixtures in tibiae. The implants were left in place for 6 weeks before the rabbits were sacrificed. Removal torque value and resonance frequency analysis (ISQ) were compared. The repeated measured analysis of variance was used with $P{\leq}0.05$ as level of statistical significance. ISQ was not different among all groups. However, the ISQ was increased after 6 weeks healing. The group had lowest ISQ value showed the greatest increment. Mg-1 implants with 9.4% retained ion dose showed significantly higher removal torque value than that of the other implants. From this results, it is concluded that the Mg-1 implants has stronger bone response than control RBM surface implant.

Accelerated Formation of Surface Films on the Degradation of LiCoO2 Cathode at High Temperature (표면 피막 형성이 LiCoO2 양극의 고온 열화에 미치는 영향)

  • Sung, Jong Hun;Hasan, Fuead;Yoo, Hyun Deog
    • Journal of the Korean Electrochemical Society
    • /
    • v.23 no.3
    • /
    • pp.57-65
    • /
    • 2020
  • It is crucial to investigate the thermal degradation of lithium-ion batteries (LIBs) to understand the possible malfunction at high temperature. Herein, we investigated the effects of surface film formation on the thermal degradation of lithium cobalt oxide (LiCoO2, LCO) cathode that is one of representative cathode materials. Cycling test at 60℃ exhibited poorer cycleability compared with the cycling at 25℃. Cathodes after the initial 5 cycles at 60℃ (60-LCO) exhibited higher impedance compared to the cathode after initial 5 cycles at 25℃ (25-LCO), resulting in the lower rate capability upon subsequent cycling at 25℃, although the capacity values were similar at the lowest C-rate of 0.1C. In order to understand degradation of the LCO cathode at the high temperature, we analyzed the cathodes surface using X-ray photoelectron spectroscopy (XPS). Among various peaks, intensity of lithium hydroxide (LiOH) increased substantially after the operation at 60℃, and the C-C signal that represents the conductive agent was distinctly lower on 60-LCO compared to 25-LCO. These results pointed to an excessive formation of cathode-electrolyte interphase including LiOH at 60℃, leading to the increase in the resistance and the resultant degradation in the electrochemical performances.

A Study on Protection of Stainless Steel Substrate against Corrosion in Molten Carbonate by Formation of Aluminum Diffusive Layer Using a Slurry Coating Method (슬러리 코팅법에 의한 스테인레스 스틸 표면에서의 알루미늄 확산막 제조 및 용융탄산염 내에서의 내식 특성 연구)

  • Nam S. W.;Hwang E. R.;Magtanyuk A. P.;Hong M. Z.;Lim T. H.;Oh I. -H.;Hong S. -A.
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.3
    • /
    • pp.136-140
    • /
    • 2000
  • A stainless steel separator for a molten carbonate fuel cell is usually coated with aluminum diffusive layer to protect its surface against corrosion by the molten carbonate at high temperatures. In this study, a relatively simple method was devised to form the aluminum diffusive layer on a stainless steel substrate. Slurry coating of aluminum on the substrate followed by heat treatment under reducing atmosphere at $650\~800^{\circ}C$ produced the aluminum diffusive layer of $25\~80{\mu}m$ thickness. The thickness of aluminum diffusive layer increased with increasing the temperature or duration of the heat-treatment. The corrosion resistance against molten carbonate under oxidizing atmosphere was significantly improved by aluminum diffusive layer formed by the sluny painting and heat treatment method. Moreover, the sample prepared in this study showed corrosion behavior similar to the sample with aluminum diffusive layer prepared by ion vapor deposition and heat treatment.

Effect of Vanadium Addition on the Cavitation Erosion Resistance of Fe-Cr-Ni-Si-C Hardfacing Alloy (Fe-Cr-Ni-Si-C계 경면처리 합금의 Cavitation Erosion 저항성에 미치는 Vanadium 첨가의 영향)

  • 김경오;김준기;장세기;김선진;강성군
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.11a
    • /
    • pp.72-72
    • /
    • 1998
  • 원자력발전소 1차계통내 밸브의 경면처리(hardfa따1잉에 사용되는 재료는 $90~343^{\circ}C$의 고온과 높은 접촉응력 그리고 급격한 압력변화가 일어나는 환경에서 사용되기 때문에 내마모성과 내식성 그리고 cavitation erosion 저항성이 우수한 Co계 Stellite 합금이 현재 사용되어진다. 그러나 Co가 원력발전소 1차계통의 방사선장을 형성하는 주요 원소로 알려지면서 S Stellite 합금을 대체할 수 있는 Fe계 경면처리용 합금을 개발하려는 연구가 진행되고 있다. 현재 Fe계 경면처리용 합금의 개발은 적절환 팝금원소를 첨가하여 적충결함에너지를 낮춤 으로써 전위의 교차슬립을 억제하여 표면을 경화시키고, 소성변형을 억제하여 마모저항성을 향상시키려는 방법으로 연구가 진행되고 있다. 본 연구에서는 Fe-Cr-Ni-Si-C 합금에 Fe계 합금의 적충결함에너지를 감소시키는 것으로 알려진 vanadium을 0, 1, 2wt%첨가하여 첨가량의 변화가 cavitation erosion 저항성에 미치 는 영향을 조사하였다. Cavitation erosion 실험은 초음파를 이용하여 미세한 기포를 발생시키는 vibratory type으로 A ASTM G-32 규격에 따라 제작된 실험장치를 이용하여 $25{\pm}2^{\circ}C$의 온도의 증류수 속에 잠긴 상태에서 실시하였다. 시면은 지름 16mm, 두게 7mm의 버턴형태로 vanadium 첨가량을 변화시킨 조성을 아크 용융 방법을 이용하여 제작하였으며 hom끝단부에 부착하여 cavitation e erosion 저항성 살험을 하였다. 시편의 cavitation erosion 실험시간에 따른 무게감소량을 측 정하였으며 cavitation erosion 시킨 시편의 표면을 SEM으로 관찰하였다.겨지는 열전달 매체액 과 신규 부식억제제가 적용된 시스템 등 객관적으로 확인된 부식억제제 시스랩에 대 하여 다양한 평가 방법을 동원 비교분석하고자 하였다. 실험은 KSM 2142에 의한 무게감량법, 분극곡선 측정에 의한 $E_P$(공식개시전위), $E_R$(재부동태화전위) 측정, 시간에 따른 자연전위 변화 측정 빛 이때의 부식속도(선형분극법), 인위적인 피막 파괴 전,후 의 전위 변화 및 부식속도 측정법에 의한 국부부식 발달 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$

  • PDF

Properties of Capacity on Carbon Electrode in EC:MA Electrolytes - I. Effect of Mixing Ratio on the Electrochemical Properties - (EC:MA 혼합전해질에서 카본 전극의 용량 특성 - I. 전기화학적 특성에 대한 혼합비의 영향 -)

  • Park, Dong-Won;Kim, Woo-Seong;Son, Dong-Un;Kim, Sung-Phil;Choi, Yong-Kook
    • Applied Chemistry for Engineering
    • /
    • v.17 no.2
    • /
    • pp.183-187
    • /
    • 2006
  • The choice of solvents for electrolytes solutions is very important to improve the characteristics of charge/discharge in the Li-ion battery system. Such solvent systems have been widely investigated as electrolytes for Li-ion batteries. In this paper, the electrochemical properties of the solid electrolyte interphase film formed on carbon anode surface and the solvent decomposition voltage in 1 M LiPF6/EC:MA(x:y) electrolyte solutions prepared from the various mixing volume ratios are investigated by chronopotentiometry, cyclic voltammetry, and impedance spectroscopy. As a result, the solvent decomposition voltages are varied with the ionic conductivity of the electrolyte. Electrochemical properties of the passivation film were different, which are dependent on the mixture ratio of the solvents. Therefore, the most appropriate mixing ratio of EC and MA as a solvent in 1 M $LiPF_6/(EC+MA)$ system for Li-ion battery is approximately 1:3 (EC:MA, volume ratio).

Evaluation on Damage Behavior of Al-4.5%Mg-0.6%Mn Al Alloy with Potentiostatic Experiment Time (Al-4.5%Mg-0.6%Mn 알루미늄 합금의 정전위 시간 변수에 따른 손상거동 평가)

  • Kim, Seong-Jong;Woo, Yong-Bin;Han, Min-Su;Jang, Seok-Ki
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.6
    • /
    • pp.569-576
    • /
    • 2012
  • In general, aluminum alloys forms the passive film($Al_2O_3$, $Al_2O_3{\cdot}3H_2O$) in neutral solution. However, the passive film created on the surface will be destroyed by chloride ions contained in sea water so the corrosion will occur. In this study, in order to solve the problem of corrosion under a seawater environment, potentiostatic protection techniques were applied to Al-4.5%Mg-0.6%Mn aluminum alloy in seawater. At polarization experiments, active state were observed at anodic polarization and concentration polarization by reduction of dissolves oxygen and activation polarization were found at anodic polarization. As a results of potentiostatic experiment, calcareous deposit were created much more as applying time increase from the turning point of the concentration polarization and activation polarization and crevice corrosion was partially observed between calcareous deposit and surface of base metal. Overall potentiostatic anodic polarization experiment was difficult to apply potentiostatic corrosion protection technology by occurrence of active state, whereas potentiostatic cathodic polarization experiment examined optimum corrosion protection condition of -1.1 V~-0.75 V within the range of concentration polarization considered various applying time.

Effect of Types and Replacement Ratio of Alkali Activator on Compressive Strength of Ground Granulated Blast Furnace Slag Mortar (알칼리 자극제의 종류 및 치환율이 고로슬래그 미분말 모르타르의 압축강도에 미치는 영향)

  • Kim, Rae-Hwan;Kim, Gyu-Yong;Kim, Jong-Hee;Lee, Bo-Kyeong;Cho, Bong-Suk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.4
    • /
    • pp.360-366
    • /
    • 2014
  • In this study, effect of types and replacement ratio of alkali activator on compressive strength of ground granulated blast furnace slag mortar has been reviewed. Types of alkali activator are NaOH, $Ca(OH)_2$, $Na_2SO_4$, and KOH. Replacement ratio of alkali activator is 7.5, 10, 12.5, and 15%, respectively. As results, under high temperature curing condition, 1 day compressive strength development with NaOH and KOH was higher than that of $Ca(OH)_2$ and $Na_2SO_4$. Regardless of types of alkali activator, compressive strength increased with increasing pH. This can be explained by the fact that impermeable film on the surface of slag which is generated when slag contacts water has been destroyed by alkali activator, and this promotes hydration reaction. Also, 1 day age compressive strength of specimen with high temperature curing was higher than that of specimen with standard curing. 28 days age compressive strength of specimen with high temperature curing was less than or equal to that of specimen with standard curing.

Pneumococcal Surface Protein A of Streptococcus pneumoniae Isolates from Koreans (한국인에서 Streptococcus pneumoniae 분리주의 폐구균 표면 단백 A)

  • Kim, Kyung Hyo
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.11
    • /
    • pp.1206-1211
    • /
    • 2005
  • Purpose : Pneumococcal protein vaccine based on pneumococcal surface protein A (PspA) is in development with the potential to offer a broad range of protection against different strains. PspA elicits protection in mice against fatal sepsis as well as carriage and lung infection. This study was performed to investigate the frequency of PspA families among Streptococcus pneumoniae recovered from Korean children and adults. Methods : A total of 89 pneumococcal isolates was included in the study. They were capsule serotyped by the slide agglutination assay with commercial antisera. PspA families were determined with polymerase chain reaction using the pair of primers for family 1 and family 2. Results : Seventeen pneumococcal serotypes were found in a total of 89 isolates. PspA typing was able to ascertain 79 of the 89 isolates (88.8 percent). Among these, 20 (22.5 percent) isolates were family 1 PspA, 59 (66.3 percent) were family 2. Moreover, because 9 (10.1 percent) isolates were of positive reactions for both, families 1 and 2 primers, the potential coverage of PspA vaccine was 98.9 percent. PspA families were not associated with age group, source of isolates, or penicillin susceptibility. However, the relative distribution of family 1 isolates to family 2 isolates was significantly different over capsular serotypes. Conclusion : The finding that 98.9 percent of Korean isolates belonging to PspA families 1 and 2 support the hypothesis that a human PspA vaccine covering a few PspA families could be broadly effective. The monitoring of the PspA families derived from large population-based isolates will be necessary in the context of vaccine development.

Electrochemical Stability of Co-Mo and Ni-Mo Intermetallic Compound Electrodes for Hydrogen Electrode of Alkaline Fuel Cell (알칼리형 연료전지의 수소극용 Co-Mo 및 Ni-Mo 금속간화합물 전극의 전기화학적 안정성)

  • Lee C. R.;Kang S. G.
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.150-155
    • /
    • 1999
  • The Electrochemical stabilities of the Brewer-Engel type intermetallic compounds of Co-Mo $(35 wt\%)$ and Ni-Mo$(35 wt\%)$ manufactured by the arc-melting method for the hydrogen electrode of $H_2-O_2$ alkaline fuel cell were investigated. Effects of temperature and concentration on the electrochemical behavior of the electrodes in the $80^{\circ}C$ 6 N KOH solution deaerated with $N_2$ gas were studied by electrochemical methods. The effect of overpotential on the electrochemical stabilities of Co-Mo and Ni-Mo intermetallic compounds was also discussed under the normal operation condition of AFC. It was shown that Co-Mo electrode had lower electrochemical stability as compared to Ni-Mo. In the case of Co-Mo electrode, a simultaneous dissolution of cobalt and molybdenum has occurred at low anodic overpotential form equilibrium hydrogen electrode potential, but the dissolution of cobalt was serious, and Co(OH)l layer on the electrode surface formed at the high anodic overpotential. In contrast the Ni-Mo electrode had high electrochemical stability because formation of the dense and thin protective $Ni(OH)_2$ layer prevented the dissolution of molybdenum.

The Effects of pH and Alkalinity Adjustment on Internal Corrosion Control and Water Quality in Drinking Water Pipelines (정수의 pH 및 알칼리도 동시 조절이 상수도관의 내부부식 제어 및 수질에 미치는 영향)

  • Lee, Hyun-Dong;Jung, Hae-Ryong;Kwak, Phill-Jae;Chung, Won-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.661-669
    • /
    • 2000
  • This research was carried out to evaluate effect of metallic release and change of water corrosive indices by the pH and alkalinity adjustment using the SDLS (Simulated Distribution Loop System) which consist of six types of pipe loop with DCIP, PVC, PE, STS304, CP, GSP, respectively, and its effects on water quality changes which were microbes quality(SPC), residual chlorine. THMs and other parameters. And it was to propose optimal criteria of water quality control for the field application. According to the results, water control system by pH and alkalinity adjustment showed the changing of corrosive water and reducing of metallic release rate and it was not affects of THMs formation, microbes regrowth and variation of other parameters. Water quality stability and corrosion control were due to calcium carbonate precipitation film formation of pipe inner by water quality control. Therefore, corrosive water control system by pH and alkalinity adjustment can be attributed to effective water quality management in water distribution system according to water quality stability of pH and TIC(Total Inorganic Carbonate concentration) that affect the precipitation and dissolution of solids.

  • PDF