• Title/Summary/Keyword: 표면초음파

Search Result 533, Processing Time 0.033 seconds

Experimental Study on Corrosion Detection of Aluminum Alloy Using Lamb Wave Mixing Technique (램파 혼합 기법을 이용한 알루미늄 합금의 부식 결함 검출에 대한 실험 연구)

  • Choi, Heeung;Lee, Jaesun;Cho, Younho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.11
    • /
    • pp.919-925
    • /
    • 2016
  • In this study, the Lamb wave mixing technique, which is basised on advanced research on the nonlinear bulk wave mixing technique, is applied for corrosion detection. To demonstrate the validity of the Lamb wave mixing technique, an experiment was performed with normal and corroded specimens. Comparison group in an experimentation are selected to mode and frequency with dominant in-plane displacement and out-of-plane displacement of Lamb waves. The results showed that the Lamb wave mixing technique can monitor corrosion defects, and it has a trend similar to that of the conventional Lamb wave technique. It was confirmed that the dominant displacement and mode matching the theory were generated. Flaw detectability is determined depending on displacement ratio instead of using the measurement method and mode selection.

아크로 증착된 TiN 박막의 특성 연구

  • Jang, Seung-Hyeon;Yang, Ji-Hun;Park, Hye-Seon;Jeong, Jae-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.177-177
    • /
    • 2010
  • 티타늄 화합물은 뛰어난 물리적 특성과 인체 무해성을 가지고 있어 생체, 내식 및 내마모 재료 등에 널리 응용되고 있으며, 다양한 색상 구현을 통한 미려한 외관 등 기능성을 위한 표면처리 분야에도 많은 관심을 받고 있다. 이중 질화 티타늄은 금색을 대체할 수 있는 물질로 코팅방법과 기판온도, 바이어스, 질소유량 등과 같은 공정변수 제어를 통해 그 물성을 변화시킬 수 있어 기능적 측면과 함께 미려한 외관처리에 응용이 가능하다. 본 연구에서는 아크(cathodic arc) 코팅 시스템을 이용하여 다양한 조건에서 TiN 박막을 제조하고 그 특성을 평가하였다. 아크 장비는 화합물 박막을 코팅할 수 있는 아크 소스와 시편 홀더, 가스 주입구, 시편 가열장치 그리고 배기 장치로 구성되어 있고, 아크 소스에 장착된 타겟은 99.5%의 Ti 타겟을 사용하였다. 시편과 타겟 간의 거리는 약 31cm이며, 시편은 알코올과 아세톤으로 초음파 세척 된 강판(냉연 강판), 실리콘 웨이퍼를 사용하였다. 시편을 진공용기에 장착하고 ${\sim}10^{-6}$ Torr까지 진공배기를 실시하고, Ar 가스를 진공용기 내로 공급하여 ${\sim}10^{-4}$ Torr에서 시편에 bias (Pulse : 400V)를 인가한 후 아크를 발생시켜 약 5분간 청정을 실시하였다. 플라즈마 청정이 끝나면 시편에 인가된 bias를 차단하고, 질소 유량, 온도, bias, 시간 등의 공정변수에 따라 코팅을 실시하였다. 질소의 유량이 80sccm 일 때, Ti 금속 결정구조가 나타났는데, 이는 질소와 충분하게 반응하지 못한 Ti이 기판에 코팅되어 나타나는 현상으로 판단된다. 색상변화에서는 질소 유량이 증가함에 따라 노란색이 짙어지며, TiN은 시편에 인가되는 bias 전압이 높아질수록 붉은색이 증가하고, 온도에 따른 큰 변화는 관찰되지 않았다. 공정변수에 따른 반사율 변화는 TiN의 경우 질소 가스 유량이 200sccm, bias 150V, 공정 온도 200도에서 반사율이 가장 높았으며, 코팅 시간이 짧을수록 반사율이 높아지는 경향을 나타냈다. 따라서 본 연구에서 얻어진 결과를 외관 코팅 분야에 응용한다면 장식성과 외관의 경도, 내마모성, 내식성의 향상 등 많은 장점을 가질 것으로 예상된다.

  • PDF

Nondestructive Deterioration Diagnosis for Wooden Ksitigarbha Triad Statues of Shinhungsa Temple in Sokcho, Korea (속초 신흥사 목조지장보살삼존상의 비파괴 손상도 진단)

  • Han, Na Ra;Lee, Chan Hee;Yi, Jeong Eun
    • Journal of Conservation Science
    • /
    • v.29 no.2
    • /
    • pp.93-102
    • /
    • 2013
  • The wooden Ksitigarbha Triad Statues (Treasure No. 1749) of Shinhungsa temple in Sokcho are enshrined in the inside of the Myeonbujeon Hall. The Statues are highly damaged physical weathering which are crack and exfoliation. Also, the Statues were deteriorated by chemical and biological weathering. This study carried out nondestructive method as deterioration map, ultrasonic measurement, X-ray and endoscopy survey for deterioration evaluation and conservation plan. As a result, Ksitigarbha Statue coated by dust and various pollutants. And gold-gilt of Statue's surface has peeled off. Head part of Mudokguiwang Statue was discolored from water leak in Myeongbujeon Hall. Domyeongjonja Statue is highly damaged by insects. Result of endoscopy, there were bee hives in the inside of the Statue. Therefore, we suggest that these Statues have need to do conservation treatment on the basis of diagnostic results.

Change of Anti-reflective Optical Property by Nano-structural Control of Alumina Layer through Hydro-thermal Process (수열합성 공정을 통한 알루미나 코팅층의 나노구조 조절에 의한 반사방지 특성의 변화)

  • Lee, Yun-Yi;Son, Dae-Hee;Lee, Seung-Ho;Lee, Gun-Dae;Hong, Seong-Soo;Park, Seong-Soo
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.564-569
    • /
    • 2010
  • Highly anti-reflective optical property has been focussed in the field of thin film and display because of increasing demands to the high transparency and clearness of optical component. In this study, to obtain anti-reflective property, the formation of aluminium oxide with nanoscaled flowerlike frame structure was introduced as oxide material monolayer on the substrate by hydrothermal synthesis through sol-gel method. The properties of coating layer were measured by the means of UV-Vis spectroscopy, FT-IR spectroscopy, XRD, and FE-SEM. The morphology of coating layer in alumina-sol coated samples was controlled by hydrothermal temperature and time with aid of ultrasound. It was found that high transparency and anti-reflective optical properties were obtained the formation of flowerlike nanoframe structure.

Rolling Contact Fatigue and Residual Stress Properties of SAE52100 Steel by Ultrasonic Nano-Crystalline Surface Modification (UNSM) (초음파 나노표면 개질처리를 통한 베어링강의 회전접촉피로 및 잔류응력 특성에 대한 연구)

  • Lee, Changsoon;Park, Ingyu;Cho, Insik;Hong, Junghwa;Jhee, Taegu;Pyoun, Youngsik
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.21 no.1
    • /
    • pp.10-19
    • /
    • 2008
  • To investigate the effect of ultrasonic nano-crystalline surface modification (UNSM) treatment on rolling contact fatigue and residual stress properties of bearing steels, this paper carried out a rolling contact fatigue test, measured residual stress and retained austenite, performed a wear test, observed microstructure, measured micro hardness, and analyzed surface topology. After the UNSM treatment, it was found that the surface became minute by over $100{\mu}m$. The micro surface hardness was changed from Hv730~740 of base material to Hv850~880 with about 20% improvement, and hardening depth was about 1.3 mm. The compressive residual stress was measured as high as -700~-900 MPa, and the quantity of retained austenite was reduced to 27% from 34%. The polymet RCF-6 ball type rolling contact fatigue test showed over 4 times longer fatigue lifetime after the UNSM treatment under 551 kgf load and 8,000 rpm. In addition, this paper observed the samples, which went through the rolling contact fatigue test, with OM and SEM, and it was found that the samples had a spalling phenomenon (the race way is decentralized) after the UNSM treatment. However, before the treatment, the samples had excessive spalling and complete exploration. Comparison of the test samples before and after the UNSM treatment showed a big difference in the fatigue lifetime, which seems to result from the complicated effects of micro particles, compressive residual stress, retained austenite, and surface topology.

Real-time impact location monitoring using the stabilized Bragg grating sensor system (안정화된 광섬유 브래그 격자 센서 시스템을 이용한 실시간 충격위치검출에 관한 연구)

  • Bang, Hyung-Joon;Hong, Chang-Sun;Kim, Chun-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.37-42
    • /
    • 2004
  • In order to monitor the impact locations in smart structures, multipoint ultrasonic sensors are to be employed. In this study, a multiplexing demodulator with wide dynamic range was proposed to detect the impact locations using FBG sensors, and a stabilization controlling system was also developed for the maintenance of maximum sensitivity of sensors. Two FBG sensors were attached on the bottom side of the aluminum beam specimen and low velocity impact tests were performed to detect the one-dimensional impact locations. As a result, multiplexed in-line FBG sensors could detect the moment of impact precisely, and found the impact locations with the average location error below 0.58mm.

The Change of Superficial and Deep Heats in Ultrasound Application by Coupling Media (초음파 적용시 전파매질에 따른 표면열과 심부열의 변화)

  • Lee, Young-Hi;Kim, Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.57-67
    • /
    • 2000
  • The purpose of this study was carried out in five rabbits of 3kg to investigate the change of superficial and deep heats in ultrasound application by coupling media. Temperature measured with thermistor needle at skin. subcutaneous, muscle in before coupling media application, after coupling media application. 2minutes. 5minutes, 7minutes, 10minutes. Coupling media was used gel, glycerin, distilled water. The data was analyzed using spss/pc+and t-test The results were as fallow : 1. With skin. gel was significant temperature change in 2minutes(p<.05). glycerin was significant temperature change in 2minutes(p<.05), 5minutes(p<.05), 7minutes(p<.01), 10minutes(p<.01). distilled water was significant temperature change in post coupling media(p<.05), 2minutes(p<.01). 5minutes(p<.05). 7minutes(p<.01). 10minutes(p<.01). With subcutaneous. gel was no temperature change. glycerin was significant temperature change in 2minutes(p<.05), 5minutes(p<.05), 10minutes(p<.01). distilled water was no temperature change. With muscle. gel was no temperature change. glycerin was significant temperature change in 2minutes(p<.05). 5minutes(p<.05). 7minutes(p<.05). 10minutes( p<.05). distilled water was significant temperature change in 10minutes(p<.05). 2. Superficial heats of skin and subcutaneous was higher temperature change than Deep heats of muscle. 3. Gel. glycerin. distilled Water required minimum treatment 10minutes fur thermal effect. 4. Gel was low temperature change superficial and deep heats. and glycerin was high temperature change superficial and deep heats. This results show that gel is high transmissiveness in the coupling media and glycerin is low transmissiveness in the coupling media.

  • PDF

Medical Imaging of Well-differentiated Liposarcoma Arising from the Falciform Fat in a Dog (개에서 겸상인대에서 유래된 분화지방육종의 영상의학증례)

  • Jung, Dong-In;Kim, Jae-Hwan;Ha, Ji-Young;Park, Ki-Tae;Yeon, Seong-Chan;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.186-189
    • /
    • 2012
  • A 7-year-old castrated male Cocker spaniel dog was referred to Gyeongsang National University Veterinary Medical Teaching Hospital with a severe abdominal distension. A huge, inhomogeneous fat opacity mass was identified on the abdomen radiographic survey. From the abdominal ultrasonographic examination, the mass was found to have irregular marginated hyperechoic capsule with cellular hypoechoic fluids inside. On the computed tomography, an encapsulated inhomogeneous mass was identified with fat attenuation peripheral and soft tissue attenuation inside. The origin of the mass was confirmed as falciform fat by surgical excision. The resected mass appeared to be a firm reddish-brown color with a smooth surface. The histopathological appearance was a well-differentiated liporsarcoma. The patient has no recurrent signs 1 month after surgery.

Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles (외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도)

  • Kim, Chang-Yong;Choi, Jong-Duk;Kim, Suhn-Yeop;Oh, Duck-Won;Kim, Jin-Kyung
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

Discharge Measurement Using ADCP Stationary Method (ADCP 정지측정법을 이용한 유량측정)

  • Kim, Yong-Jeon;Lee, Chan-Joo;Yoo, Min-Wook;Kim, Dong-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.462-466
    • /
    • 2010
  • 하천을 횡단하며 유속을 측정하는 ADCP를 유속면적법과 같이 정해진 측선에 정지시켜 연직 유속을 측정하고 이를 단면적과 곱하여 유량을 산정하는 방법이 ADCP 정지측정법(Stationary Method)이다. 이 방법은 이미 괴산댐 하류에 적용되어 정지측정법 측정유량이 댐방류량 대비 평균 4%의 상대오차를 보여 효율성이 입증되었다. 본 연구에서는 일반 자연하천인 임진강 적성지점에 정지측정법을 적용하여 넓은 범위의 수위, 유량 변화에 대한 적용 가능성을 점검하였다. 또한 홍수기 널리 사용되는 측정방법인 부자법의 검증 수단으로서 적용 여부를 검토하였다. 2009년 7월부터 8월까지 총 26회 실시한 정지측정법은 1,046~9,663 $m^3/s$의 측정 유량 범위를 보였다. 측정기간 동안 단면평균 유속은 1.3~3.0m/s였으며, 측정 최대유속은 4.0m/s였다. 측정 소요시간은 23~46분으로 평균 35분 소요되었다. 같은 지점에서 실시한 봉부자법 측정이 평균 29분 소요한 것과 큰 차이가 없었다. ADCP를 이용한 정지측정법은 제조사에서 제공하는 전용 프로그램으로 측정과 동시에 수위, 단면 연직 유속 등의 확인이 가능하며, ISO 기준 불확실도 계산 기능을 포함한다. 대하천인 임진강 적성지점에서 실시한 ADCP 정지측정법은 봉부자법과 비슷한 측정시간이 소요되며 넓은 수위, 유량범위에서 측정이 가능한 방법으로 판단되었다. 기존의 유량측정이 수위, 유량에 따라 방법이 달라지고 측정 장비의 제약이 따르는 것에 반해 ADCP 정지측정법은 보다 넓은 수위, 유량 범위에서 적용이 가능하다. 즉, ADCP 정지 측정법은 평저수시뿐만 아니라 홍수시에도 유량 측정 가능한 방법이기 때문에 봉부자법 또는 초음파표면유속계와 같이 홍수시 사용되는 측정방법의 검증 수단으로서도 활용 가능할 것으로 판단된다.

  • PDF