• Title/Summary/Keyword: 표면세척

Search Result 353, Processing Time 0.024 seconds

The Microbiological Evaluation of Environments and Facilities at Food Service Operations in Elementary School (초등학교 단체급식 소의 환경과 급식설비에 대한 미생물 평가)

  • 정동관;류은순
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.2
    • /
    • pp.216-220
    • /
    • 2002
  • The microbiological examinations of food service operations were conducted for the hygienic evaluation at four elementary schools in Busan, Korea. Total one hundred and seventy two swabbed samples using sponge were collected from the surface of environments, utensils and equipments of food service facilities and analyzed by measuring the total, coliform and psychrotrophic count. Sampling sites were the surfaces of floors, drains, walls, knives, cutting boards, rubber gloves, vinyl aprons, plastic containers, carriers, shelves, trays, dry shelves, electric tray dryer, food containers, soup containers, rice cookers, frying pans, boiling cookers, refrigerators, dumb waiters and dishwashers. The swabbed samples kept in an ice-parked box were transported to a laboratory and analyzed. The results demonstrated that the degree of contamination depended on the sampling sites. Averages of total counts of surface swab samples were ranged from 0.62 to 7.79 Log CFU/200 cm$^2$. The level of coliforms were ranged from not detectable to 5.26 Log CFU/200 cm$^2$, and those of psychrotrophs from not detectable to 6.15 Log CFU/200 cm$^2$. The severely contaminated sites were dumb waiters, drains, rice cookers, knives, plastic containers and floors. Also cutting boards, rubber gloves, carriers, drying shelves, vinyl aprons, boiling cookers, soup containers, frying pans and refrigerators were highly contaminated with the level of abode 3.5 Log CFU/200 cm$^2$. Therefore, those sites should be focused and controlled according to control points of sanitation standard operating procedures (SSOP). Also, periodic microbiological examination in addition to visual examination is recommended on these highly contaminated sites indicated above results at food service operations in elementary school.

Chromaticity Improvement of PEG Waste from Wire Sawing of Silicon Ingot (실리콘 잉곳 절삭시 발생하는 폐 PEG 색도 개선에 관한 연구)

  • Cho, Yun-Kyeong;Jung, Kyeong-Youl;Sim, Min-Seok;Lee, Gi-Ho
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.310-316
    • /
    • 2012
  • The chromaticity of polyethylene glycol (PEG) generated from the recyling of a silicone slurry waste was improved by using activated carbon powder and a carbon filter. The color change of the PEG waste was investigated by changing the amount of adsorbent, adsorption time and temperature. The surface area of activated carbon did not have a significant impact on improving the color of the PEG waste. According to the results for the APHA color variation of the PEG waste changing the amount of the carbon adsorbent, the optimal usage to achieve the low APHA value was 100~150 mg-C/g-PEG. From the investigatnion on the effect of the adsorption temperature range from $25^{\circ}C$ to $100^{\circ}C$, it was found that the optimal temperatures were $40{\sim}50^{\circ}C$ in terms of achieving the lowest APHA value. The variation of the APHA color was investigated by changing the operation condition of the activated carbon filters. The use of ACF was a good way to enhance the chromaticity of the PEG waste. As a result, the APHA value of the PEG waste (APHA=53 at the initial waste) was reduced to be 10 through the ACF purification. It was also confirmed that the performance of the used carbon adsorbent can be recovered by the washing with purified water.

Effect of Ultrasonic Pretreatment on Analysis of Potassium Ion in Human Urine Using 15-Crown-5-Anthracene-based Membrane (15-Crown-5-Anthracene 막을 이용한 요 중의 칼륨이온 분석에 미치는 초음파 전처리의 효과)

  • Lee, Ji-Young;Chang, Hye-Young;Bae, Zun-Ung
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.1
    • /
    • pp.13-18
    • /
    • 2003
  • The effect of ultrasonic decomposition was introduced to develop a pretreatment method for the analysis of potassium ion in human urine by potentiometry. N-(4’-benzo-15-crown-5)-anthracene-9-imine, which has a good selectivity coefficient for potassium against ammonium, was used as an ion-selective material for the determination of potassium in urine with relatively high concentration of $NH_4{^+}$. Protenis in urine be removed by 85.1% when the sample acidified with 1.0 M $HNO_3$ was preteated for 100 s by sonication. Potential response of the membrane electrode in the pretreated urine had a slope of 54.6(${\pm}0.2,\;n=5$) mV/decade over the linear range of log $[K^+]$=-5~-1(r=0.9997). When an oxidant, $H_2O_2$, was addwd to the urine sonicated with $HNO_3$, the deproteinization increased 10% more than that in case if only $HNO_3$ and then the maximum ratio of ca. 95% was obtained. Moreover, the Nernstian slope for $K^+$ added to the urinary sample increased to 56.7(${\pm}0.1,\;n=3$) mV/decade. When the calibration curves were measured, the slopes did not vary even after the electrode was successively used 20 times with ultrasonic cleaning. The results showed that an ultrasonic pretreatment method provides simplicity in use, reduced treatment time and improved potentiometric characteristics of the membrane as the method effectively removes ca. 95% of proteins in urine.

Infection control of dental implant hand drivers using ethanol solution (에탄올을 이용한 치과 임플란트 핸드 드라이버의 감염 관리에 대한 연구)

  • Yu, Song-Yi;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.158-167
    • /
    • 2020
  • Purpose: The purpose of this study was to study the effects of the utilization of ethanol solution in infection control of dental implant hand drivers, a common practice in dental prosthodontic clinics. Materials and Methods: Infection control methods were divided into two groups. One swabbed with 83% ethanol gauze and the other immersed in 83% ethanol solution for 30, 60, 90, 120, 150, 180 and 300 second intervals after inoculation of the dental implant hand drivers with Staphylococcus aureus. After measuring the number of colony forming units and analyzing the optical density, the effects of infection control in the experimental group were compared with the positive control group without infection control after inoculation with bacteria and the negative control group without inoculation with bacteria after sterilization. Results: The number of colony forming units and optical density analysis showed a statistically significant difference compared to the positive control. On the other hand, there was no statistically significant difference between the negative control and the group immersed in the 83% ethanol solution for more than 150 seconds. Conclusion: It is recommended to use the ethanol solution as a pre-cleaning process before sterilization, since the intermediate-level disinfection method using ethanol solution alone for the infection control of the dental implant hand driver cannot clinically secure the sterility.

Characteristics of heavy metal concentrations in urban stormwater runoff, Daejeon, Korea (도시 유역 강우유출수 내 중금속 농도의 변화 특성에 관한 연구)

  • Yu, Eunjin;Seo, Dongil
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.10
    • /
    • pp.917-927
    • /
    • 2018
  • Seven heavy metal concentrations (As, Cd, Cr, Cu, Ni, Pb, Zn) were continuously analyzed for twenty rainfall events in 2017~2018 in an urban basin. The overall and dynamic correlations between runoff characteristics and heavy metal concentrations were examined. The peak metal concentration generally appeared in the initial runoff but found to be delayed when the rainfall intensity was low. The rainfall duration had no relationship with either heavy metal concentrations or their total mass. Dynamics of heavy metal mass (load), with the exception of Cu and Zn, showed strong correlation with the 30 minute rainfall intensity (0.60~0.88) and runoff volume (0.74~0.89). While event mean concentration (EMC) showed positive correlation (0.54~0.73) with antecedent dry days (ADD), no significant relationship was found between runoff volume and pollutant concentration. This implies that the pollutants built up on the surface during dry days are washed off even with low rainfall energy. The dynamics of heavy metal and TSS concentrations showed good correlation (0.68~0.87). This result shows that the metals are transported along with solid particles as adsorbate in surface runoff. Regular street sweeping will reduce significant amount of heavy metal loads in urban surface runoff.

A Study on Rust Cleaning of Various Industrial Equipment Using Cosmetic and Food Materials (화장품과 식품 재료를 이용한 각종 산업장비 녹(rust) 세정에 관한 연구)

  • Yeom, Seok-Jae;Jung, Sundo;Oh, Eunha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.19-28
    • /
    • 2021
  • Corrosion is the degradation of metals by reaction with the environment. It is difficult to completely remove. Corrosion proceeds rapidly after the protective barrier is destroyed, and several reactions occur that alter the composition and properties of the metal surface and local environments, such as diffusion of metal cations into the matrix, the formation of oxides, and local pH changes. The study of corrosion of steel and iron is of theoretical and practical interest and is receiving considerable attention. Acid solutions, which are widely used in industrial pickling, acid descaling, cleaning and acidification of oil wells, require the use of corrosion inhibitors to suppress corrosion attacks on metallic materials. Physical removal of rust requires expensive special equipment, and chemical removal of it can cause corrosion or shorten the life of the metal. In this study, an eco-friendly rust cleaner was developed using cosmetics and food materials by applying the concept of perm reducing agent and chelate, and applied to remove rust from industrial and hot water pipes and various industrial devices. As a result, it was found that rust cleaners remove rust more effectively and safely compared to conventional treatment methods. At the same time, the rust removal efficiency was 1.75 to 2.5 times better for industrial piping and 1.56 to 2.2 times better for boiler hot water than conventional methods.

Investigation of microbial contamination in meal kit products purchased via online shopping (온라인에서 구매한 밀키트 제품의 미생물 오염도 조사)

  • Lee, Seung Hun;Nam, Su Jin;Kim, Dong Woo;Kim, Gi Ryeon;Park, Seon Jeong;Lee, Eun Ji;Je, Hyeon Ji;Koo, Ok Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.235-240
    • /
    • 2022
  • In this study, the delivery conditions and microbial contamination in Mille-feuille Nabe and fresh spring roll meal kits purchased online were assessed. The average surface temperature on the product arrival was 14.4℃. The average number of total aerobic bacteria and coliforms in Mille-feuille Nabe was 3.27 log CFU/g and 1.27 log CFU/g, respectively, in meat, and 6.66 log CFU/g and 2.94 log CFU/g, respectively, in vegetables. The average number of total aerobic bacteria and coliforms in fresh spring rolls was 3.82 log CFU/g and 1.93 log CFU/g in meat, and 5.62 log CFU/g and 3.31 log CFU/g in vegetables, respectively. Escherichia coli was detected in bok choy and perilla leaves, with an average of 0.86 log CFU/g. Salmonella spp. and E. coli O157:H7 were not detected in any of the samples; however, Listeria monocytogenes was detected in all three beef samples. Therefore, before consuming meal kits, sufficient washing and heating are recommended to prevent occurrences of food poisoning.

Scientific Investigation and Conservation Treatment of the Three-story Stone Pagoda at Jangha-ri, Buyeo (부여 장하리 삼층석탑의 과학적 조사 및 보존처리)

  • Kim, Joohyung;Han, Minsu
    • Conservation Science in Museum
    • /
    • v.27
    • /
    • pp.103-124
    • /
    • 2022
  • This study examined the properties of the materials used in the three-story pagoda at Jangha-ri, Buyeo. It was performed in order to identify the objective condition of the pagoda and establish an appropriate plan for the conservation treatment of the pagoda. According to the study, the average total magnetic susceptibility was 3.71 (10-3 SI unit), and at least four types of granite with different origins were likely used in the production of the pagoda. The ultrasonic velocity averaged 1,519m/s, and the coefficient of weathering showed an average of grade 4. The thermal gradient between the cement (restoration materials) and original materials was identified through thermal imaging. In some areas, the cement restoration materials required replacement with new stone materials with properties similar to those of the original stone materials. Taking into account these results, a map of weathering damage was prepared and appropriate conservation treatment plans were established based on the findings of previous studies. Since the pagoda had suffered severe biological damage and discoloration, surface contaminants were removed through wet cleaning with distilled water and a brush. The exfoliated areas were reinforced on the site by mixing epoxy resin with powdered stone with the same properties as the original stone materials of the pagoda.

Conservation Treatment of Jangbogwan from the Joseon Dynasty (조선시대 장보관(章甫冠)의 보존처리)

  • Lee Hyelin;Park Seungwon
    • Conservation Science in Museum
    • /
    • v.30
    • /
    • pp.1-22
    • /
    • 2023
  • This study aims to document the conservation treatment of the fine-hemp official headgear housed by the National Museum of Korea, and to reconsider its existing name following the restoration of the original form of the damaged cultural heritage asset. The headgear consists of a single inner frame with a vertical line at the front, a single outer frame surrounding the inner frame, and a double-layered headband that spans the circumference of the wearer's head and joins the inner and the outer frames. This study applied a conservation treatment to the men's undyed hemp headgear of the Joseon Dynasty in order to remove contaminants and foreign substances on the surface and repair the partially deteriorated and damaged fabric, thereby restoring and stabilizing the original shape and preparing it for exhibitions. The hemp headgear was sewed both by hand and with a sewing machine. Although its overall composition and style are similar to the same type of official headgear from the Joseon Dynasty, the use of a sewing machine supports the assumption that it was produced in the early 1900s. This study identified similarities between the overall composition and shape of the fully-preserved hemp official headgear and those of the jangbogwan, a type of men's official headgear worn by Confucian scholars as part of their everyday attire, and compared it with the shape of jangbogwan seen in documentary records, illustrations, prior research, and portraits from the Joseon Dynasty, as well as with the characteristics of extant jangbowan artifacts, eventually concluding that it is appropriate to classify and name the headgear as a jangbogwan.

The effect of silane treatment timing and saliva contamination on shear bond strength of resin cement to porcelain (Silane의 처리시기와 타액오염이 도재-레진 시멘트의 전단 결합강도에 미치는 영향)

  • Ro, Young-Seon;Ryu, Jae-Jun;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.61-69
    • /
    • 2009
  • Statement of problem: Porcelain veneers have become a popular treatment modality for aesthetic anterior prosthesis. Fitting porcelain veneers in the mouth usually involve a try-in appointment, which frequently results in salivary contamination of fitting surfaces. Purpose: An in vitro study was carried out to investigate the effect of silane treatment timing and saliva contamination on the resin bond strength to porcelain veneer surface. Material and methods: Cylindrical test specimens (n=360) and rectangular test specimens (n=5) were prepared for shear bond test and contact angle analysis. Whole cylindrical specimens divided into 20 groups, each of which received a different surface treatment and/or storage condition. The composite resin cement stubs were light-polymerized onto porcelain adherends. The shear bond strengths of cemented stubs were measured after dry storage and thermocycling (3,000 cycles) between 5 and $55^{\circ}C$. The silane and their reactions were chemically monitored by using Fourier Transform Infrared Spectroscopy analysis (FTIR) and contact angle analysis. One-way analysis of variance (ANOVA) and Dunnett's multiple comparison were used to analyze the data. Results: FT-IR analysis showed that salivary contamination and silane treatment timing did not affect the surface interactions of silane. Observed water contact angles were lower on the saliva contaminated porcelain surface and the addition of 37% phosphoric acid for 20 seconds on saliva contaminated porcelain increased the degree of contact angle. Silane applied to the porcelain, a few days before cementation, resulted in increasing the bond strength after thermocycling. Conclusion: Within the limitation of this study, it can be concluded that it would be better to protect porcelain prosthesis before saliva contamination with silane treatment and to clean the contaminated surface by use of phosphoric acid.