• Title/Summary/Keyword: 폴리염화비닐

Search Result 47, Processing Time 0.021 seconds

Risk of Smoke Occurring in the Combustion of Plastics (플라스틱의 연소 시 발생하는 연기 위험성에 관한 연구)

  • You, Jisun;Chung, Yeong-jin
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • In this study, the combustibility of five types of plastic plates, fiber reinforced plastic (FRP), polystyrene (PS), polycarbonate (PC), polypropylene (PP), and polyvinyl chloride (PVC), were tested using a cone calorimeter (ISO 5660). The PVC plate showed a $44.65kW/m^2$ lower peak heat release rate (HRR) and a $30.97kW/m^2$ lower maximum average rate of heat emission than the other four types of plastics, whereas the PS plate showed a $773.44kW/m^2$ higher peak HRR and $399.14kW/m^2$ higher maximum average rate of heat emission. The PC plate and PS plate showed the highest HRR by a maximum of 3.88 times in $CO_{mean}$ yields, while the PS pate and PP plate showed the highest HRR by a maximum 4.88 times in $CO_{2mean}$ yields. In addition, the smoke performance index (SPI) of the PS plate decreased by 74.81%~95.99%; the smoke growth index (SGI) increased to 76%~300%; the smoke intensity (SI) also increased to 917.73% ~ 9607.57%, and the danger of smoke increased. The PS plate was found to have the highest risk of life damage due to smoke on the thermal and smoke sides.

In Vitro Antitumor Activity of BCNU-Loaded PLGA Wafer Containing Additives (첨가제 함유 BCNU/PLGA웨이퍼의 in vitro 항암 활성)

  • Lee, Jin-Soo;An, Tae-Kun;Shin, Phil-Kyung;Chae, Ghang-Soo;Jeong, Je-Kyo;Lee, Bong;Cho, Sun-Hang;Khang, Gil-Son;Lee, Hai-Bang
    • Polymer(Korea)
    • /
    • v.27 no.3
    • /
    • pp.217-225
    • /
    • 2003
  • We fabricated the 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU, carmustine)-loaded PLGA wafers containing poly(N-vinylpyrrolidone) (PVP) or tedium chloride (NaCl) in order to control the release profile of drug in special shape (3 in diameter, 1 mm in thickness) by direct compression method. In vitro release profiles of BCNU could be controlled by additives contained in the wafers. Initial release amount, release rate and duration of BCNU could be controlled with presence of PVP or NaCl. In vitro antitumor activity accessed using 9L gliosarcoma cell line has been evaluated by assaying the viability of cells treated with BCNU released from the wafers containing additives resulting in continuous growth inhibition of 9L gliosarcoma tumor cells. Specially, the continuous growth inhibition of BCNU-loaded PLGA wafers containing additives was more effective than that of non-additive BCNU-loaded PLGA wafers. The cytotoxic effect of the drug from the wafers containing NaCl as compared to wafers containing PVP was more enhanced.

A comprehensive review of microplastics: Sources, pathways, and implications (미세 플라스틱의 종합적 고찰: 근원, 경로 및 시사점)

  • Yano, K.A.V.;Reyes, N.J.D.G.;Geronimo, F.K.F.;Jeon, M.S.;Kim, Y.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.153-160
    • /
    • 2020
  • Most studies defined microplastic (MP) as plastic particles less than 5 mm. The ubiquity of MP is raising awareness due to its potential risk to humans and the environment. MP can cause harmful effects to humans and living organisms. This paper review aimed to provide a better understanding of the sources, pathways, and impacts of MP in the environment. MP can be classified as primary and secondary in nature. Moreover, microplastic can also be classified as based on its physical and chemical characteristics. Stormwater and wastewater are important pathways of introducing MP in large water bodies. As compared to stormwater, the concentrations of MP in wastewater were relatively lower since wastewater treatment processes can contribute to the removal of MP. In terms of polymer distribution, wastewater contains a wider array of polymer varieties than stormwater runoff. The most common types of polymer found in wastewater and stormwater runoff were polypropylene (PP), polyvinyl chloride (PVC), polystyrene (PS), polyethylene (PE) and polyethylene terephthalate (PET). The continuous discharge and the increasing number of MP in the environment can pose greater hazards and harmful effects on humans and other living organisms. Despite the growing number of publications in relation to MP, further studies are needed to define concrete regulations and management strategies for mitigating the detrimental effects of MP in the environment.

Ammonia removal rate on ammonia loading rates in seawater filtering system using rotating biological contactor (RBC) (회전원판을 이용한 해수 순환여과 시스템에서 암모니아 부하율에 따른 암모니아 제거율)

  • SON Maeng Hyun;JEON Im Gi;CHO Kee Chae;KIM Kang Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.4
    • /
    • pp.367-372
    • /
    • 2000
  • A series of experiment was conducted to investigate the relationship between ammoia removal rate and ammonia loading rates in seawater filtering system using rotating biological contactor (RBC). In this experiment, RBC system was consisted of rotating polyvinyl film disks, which provided $12 m^2$ of total effective surface area in $0.075 m^3$ of volume. $NH_4Cl$ was added by $10{\~}150 g$ as a ammonia nitrogen source to determine ammonia removal rate in RBC system. Relationship between time required for ammonia removal (y: hour) and nitrogen inputted ($x: NH_4-N mg/l$) in RBC system was as followed: $y=3.51+7.76 lnx (r^2=0.936)$. At ammonia concentration $2 mg/l$, it took 10 hour for removal of ammonia in the RBC system. However, at ammonia concentration of $5 and 16.5 mg/l$, it took 16 and 27 hours, respectively. There was a decreasing tencency of an increasing ammonia in the rearing water. Finally, the ammonia removal rate in the RBC system increased with the rise of total ammonia concentration up to $16.5 mg/l$.

  • PDF

Effect of Different Variable Selection and Estimation Methods on Performance of Fault Diagnosis (이상진단 성능에 미치는 변수선택과 추정방법의 영향)

  • Cho, Hyun-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.551-557
    • /
    • 2019
  • Diagnosis of abnormal faults is essential for producing high quality products. The role of real-time diagnosis is quite increasing in the batch processes of producing high value-added products such as semiconductors, pharmaceuticals, and so forth. In this study, we evaluate the effect of variable selection and future-value estimation techniques on the performance of the diagnosis system, which is based on nonlinear classification and measurement data. The diagnostic performance can be improved by selecting only the variables that are important and have high contribution for diagnosis. Thus, the diagnostic performance of several variable selection techniques is compared and evaluated. In addition, missing data of a new batch, called future observations, should be estimated because the full data of a new batch is not available before the end of the cycle. In this work the use of different estimation techniques is analyzed. A case study on the polyvinyl chloride batch process was carried out so that optimal variable selection and estimation methods were obtained: maximum 21.9% and 13.3% improvement by variable selection and maximum 25.8% and 15.2% improvement by estimation methods.

Preparation and Properties of Eco-friendly Waterborne Polyurethane-urea Primer for Thermoplastic Polypropylene Applied to Automobile Interiors (자동차 내장재용 열가소성 폴리프로필렌에 적용되는 선처리제용 친환경 수분산 폴리우레탄-우레아의 제조 및 성질)

  • Shin, Jong Sub;Park, Jin Myeong;Lee, Young Hee;Kim, Han Do
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.232-240
    • /
    • 2014
  • The significance of thermoplastic polyolefin polypropylene (PP) lies in its potential to replace polyvinyl chloride (PVC), the most widely used material for automobile interiors (door trim, dash board), which discharges harmful compounds in certain conditions. Another benefit of PP (0.855 amorphous - 0.946 crystalline $g/cm^3$) is its low density compared to that of PVC ($1.1-1.45g/cm^3$), which reduces vehicle weight. Market demand for eco-friendly water-based adhesive/coating material is rising significantly as a substitute for solvent-based adhesive/coating material which emits VOC and causes harmful working conditions. Under such context, in this study, a series of eco-friendly waterborne polyurethane-urea primer (a paint product that allows finishing paint to adhere much better than if it were used alone) for hydrophobic PP were prepared from different mix of DMPA content, NCO/OH molar ratio, various wt% of silicone diol and various soft segment content, among which DMPA of 21 mole %, NCO/OH molar ratio of 1.2, modified silicone diol of 5 wt% and soft segment content of 73 wt% led to good adhesion strength. Additionally, the incorporation of optimum content of additives (0.5 wt% dispersing agent, 0.5 wt% levelling agent, 1.5 wt% antifoaming agent, 3.0 wt% matting agent) into the optimum waterborne polyurethane-urea also enabled good stability, levelling, antifoaming and non-glossy.

Characteristics of BCNU-loaded PLGA Wafers (BCNU를 함유한 생분해성 PLGA 웨이퍼의 특성분석)

  • 안태군;강희정;이진수;성하수;정제교
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.691-700
    • /
    • 2002
  • Interstitial therapy using biodegradable polymeric device loaded with anticancer agent can deliver the drug to the tumor site at high concentration, resulting in an increase of therapeutic efficacy. 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU, carmustine) is most commonly used as chemotherapeutic agent for brain tumors. The design of implantable device is regarded as an important factor lot the efficient delivery of antitumor agent to targeting site. In order to control the release profile of drug, the release pattern of BCNU with the changes of various dimension and additives was investigated. The PLGA wafers containing 3.85, 10, 20 and 30% of BCNU were prepared in various shape (diameter of 3, 5 and 10 mm, thickness of 0.5, 1 and 2 mm) by direct compression method. In vitro drug release profile of BCNU-loaded PLGA wafers could be controlled by changing the dimension of wafers such as initial drug content, weight, diameter, thickness, volume and surface area of wafers, as well as PLGA molecular weight and additives. Drug release from BCNU-loaded PLGA wafers was facilitated with an increase of BCNU-loading amount or presence of poly(N-vinylpyrrolidone)(PVP) or sodium chloride (NaCl). The effects of various geometric factors and additives on the BCNU release pattern were confirmed by the investigation of mass loss and morphology of BCNU-loaded PLGA wafers.