• Title/Summary/Keyword: 포화압력

Search Result 207, Processing Time 0.024 seconds

The Method of Estimating Group Effect with Small Pull-out Tests of Screw Anchors (나선형 앵커의 실내인발시험을 이용한 무리효과 평가기법)

  • Park Si-Sam;Lee Hyung-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.10
    • /
    • pp.123-131
    • /
    • 2005
  • In the present study, laboratory pull-out tests with screw anchors are carried out to investigate behavior characteristics of the anchors used in foundation system of underground structures which are applied to uplifting seepage forces. Small scaled pull-out tests in sand under saturated condition and dry condition were carried out. For estimating the group effects of the anchors, the upward displacement and the pullout load varied with spacing of the anchor were observed. The test results were compared with theoretical equation for the ultimate pull-out force. Also, the result of tests can be used to the finite element analysis program, $PENTAGON^{2D}$.

Petrological Characteristics of Two-Mica Granites : Examples from Cheongsan, Inje-Hongcheon, Yeongju and Namwon areas (복운모 화강암의 암석화학적 특징 : 청산, 인제-홍천, 영주 및 남원지역의 예)

  • 좌용주
    • The Journal of the Petrological Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.210-225
    • /
    • 1997
  • From their general natures of peraluminous, S-type and ilmenite-series granites, two-mica granites in the Cheongsan, Inje-Hongcheon, Yeongju and Namwon areas were originated from crust-derived granitic magma and solidified under reducing condition. Each two-mica granite in Inje-Hongcheon and Namwon districts was differentiated from the the residual magma of porphyric biotite granite and high Ti/Mg biotite granite, respectively. The genetic relationships between two-mica granite and porphyritic biotite granite in Chenongsan district and between two-mica granite and biotite granodiorite in Yeongju district are ambiguous. In Namwon district granitic magmas were water-saturated and possible water solubilities in magmas were more than 5.8wt.%. In Yeongju district two-mica granitic magma was nearly water-saturated and showed possible water solubilities between 2.4~5.8wt.%. Two-mica granitic magmas in Cheongsan and Inje-Hongcheon districts were water-undersaturated. Pressure-dependent minimum melt compositions (0.5~2kb) and petrographic textures of two-mica granites in Inje-Hongcheon and Yeongju districts represent that the granites intruded and solidified at shallow level, whereas those in Cheongsan and Namwon districts exhibit relatively deeper level of granitic intrusion (2-3kb). The intersection of granite-solidus/muscovite stability indicates that magmatic primary muscovite can be crystallized from the water-saturated magma above 1.6kb (ca. 6km), but below the pressure muscovite can be formed by the subsolidus reaction. On the other hand, more pressure would be necessary for the crystallization of primary muscovite from the water-undersaturated magma. This pressure condition can explain the occurrence of primary and secondary muscovites from the two-mica granites in the areas considered. The experimental muscovite stability must be cautious of the application to examine the origin of muscovite. The muscovite stability can move toward high temperature field with adding of Ti, Fe and Mg components to the octahedral site of pure muscovite end member.

  • PDF

Effect of Aspect Ratio of Flat Tube on R410A Evaporation Heat Transfer and Pressure Drop (납작관의 종횡비가 R-410A 증발열전달 및 압력손실에 미치는 영향)

  • Kim, Nae Hyun;Lee, Eul Jong;Byun, Ho Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.395-404
    • /
    • 2013
  • In this study, R-410A evaporation heat transfer tests were conducted in flattened tubes made from 5-mm round tubes. The test range covered a saturation temperature of $15^{\circ}C$, heat flux of $5{\sim}15kW/m^2K$, and mass flux of $200-400kg/m^2s$. The results showed that both the condensation heat transfer coefficient and the pressure drop increased as the aspect ratio increased, with a pronounced increase for an aspect ratio of 4. A comparison of the flattened tube data with existing correlations revealed that the heat transfer coefficients were reasonably predicted by the Shah correlation, and the pressure drops were reasonably predicted by the Jung and Radermacher correlation.

XPS Analysis of Acrylic Acid Films Polymerized by Remote Plasma-Enhanced Chemical Vapor Deposition (원격 플라즈마 화학기상증착법에 의해 중합된 아크릴산 필름의 XPS 분석)

  • Kim, Seonghoon;Seomoon, Kyu
    • Applied Chemistry for Engineering
    • /
    • v.20 no.5
    • /
    • pp.536-541
    • /
    • 2009
  • Plasma-polymerized acrylic acid films were deposited on Si wafer and KBr pellet by remote plasma-enhanced chemical vapor deposition (PECVD). Effects of plasma power, reaction pressure, indirect plasma method on the growth rate, chemical structure, and chemical bonding state of the films were investigated. Chemical structure and chemical state of the films were characterized by Fourier transformed infrared (FT-IR) spectroscopy and X-ray photoelectron spectroscopy (XPS) analysis and curve fitting technique. Growth rate of the film increased to a saturation value with plasma power of 100 W, but showed the maximum with reaction pressure at 300 mtorr. Whenever W/FM factor (applied energy per gas molecule) increased by increasing plasma power or lowering pressure, the fragmentation of acrylic acid molecules was promoted. From the XPS curve fitting analyses, we found that the intensity of carboxyl COO bonding peak decreased with W/FM factor, and the tendency of intensity change of carboxylic COO peak was contrary to those of ether C-O and carbonyl C=O peaks.

Effects of Sputtering Ar Pressure on Magnetic and Magneto-optical Propwrties in Compositionally Modulated Co/Pd Supwrlattice Thin Films (조성변조 Co/Pd 초격자 박막의 Ar가스 압력변화에 따른 자기 및 자기광학적 특성)

  • 김진홍;신성철
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.119-124
    • /
    • 1992
  • We have investigated the effects of sputtering Ar gas pressure on magnetic and magneto-optical properties in compositionally modulated Co/Pd superlattice thin films. The samples were prepared by dc magnetron sputtering from 2-in.-diam Co and Pd targets by alternately exposing the substrates to targets. Sputtering Ar gas pressure was varied from 2 to 30 mTorr. All samples had same bilayer thicknesses composed of 2-$\AA$-thick Co and 9-$\AA$-thick Pd sublayers. It was observed that the colum-nar structure was more distinctively developed with increasing Ar gas pressure. We observed that the intrinsic uniaxial anisotropy energy, magnetization and polar Kerr rotation were decreased with increasing Ar gas pressures. Large coercivity and perfect squareness were attained by the deposition at the high Ar gas pressure. We believe that the results are mainly ascribed the variation of micro-structure with sputtering Ar gas pressure.

  • PDF

A Study on the Vertical Bearing Capacity of Batter Piles Subjected to Vertical Load (연직하중을 받는 경사말뚝의 연직지지력에 관한 연구)

  • 성인출;이민희;최용규;권오균
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.49-55
    • /
    • 2003
  • In this study, based on the relationship of the vertical force - settlement of batter piles obtained by pressure chamber model tests, the vertical bearing capacity of vertical and batter piles according to the increase of pile inclination was analyzed. A model open - ended steel pipe pile with the inclination of 5$^\circ$, 10$^\circ$ and 15$^\circ$ was driven into saturated fine sand with relative density of 50 %, and the static compression load tests were performed under each confining pressure of 35, 70 and 120 kPa in pressure chamber. The vertical bearing capacity of pile obtained from pressure chamber tests increased with the pile inclination. In the case of the inclination of 5$^\circ$, 10$^\circ$, 15$^\circ$, increasing ratios of pile bearing capacity were 111, 121, 127 ~ 140 % of vertical bearing capacity respectively. In the case of the inclination of above 20$^\circ$, the model tests could not be performed because of pile of pile head during compressive loading on the pile head.

대면적 Transformer coupled Plasma Source에서 파워결합에 관한 실험적 연구

  • 김희준;손명근;황용석
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.166-166
    • /
    • 1998
  • 반도체 공정에서 기존보다 큰 30cm 웨이퍼훌 이용하기 위해서 기존의 ECR, Helicon, ICP, 등 공정용 고 밀도 플라즈마 원들의 대면적화에 대한 연구가 세계적으로 진행되고 있다 현 상황에서는 평판형 안테 나룰 이용한 TCP가 대면적용 폴라즈마 원의 가장 유력한 후보로 여겨지고 있다 TCP롤 대면적화 하는 데 있어서 중요한 문제점으로는 대면적에서의 큰 안테나 인되턴스로 인한 임피던스 정합과 대면적에서 의 유전울질의 기계적 강도이다. 앓은 유전물질올 사용힐 수 있도록 대면적 TCP 플라즈마 원올 실계 저l작하였고 이차원 가열이론올 이용한 TCPRP code 률 이용하여 안테나의 반경옳 결정하였디 안테나의 인덕턴스 값올 줄이기 위해서는 주m수는 13.56MHz 보다 낮은 4-5MHz 부근에서 작동하는 RF 파워룰 선택하였다 이 파워 서플라이는 보통 사용되는 50n 흩력 입묘$\mid$던스훌 갖는 형태가 Of니라 LC 공진현상 올 이용하여 부하에 파워률 전달하는 형태이다 .. TCP 장치에 사용할 수 있도록 파워 서플라이 흩력 단에 안테나와 직혈로 가변 콘덴서를 달아서 임11I던스 정합올 힐 수 있게 하였다 안테나에 직훌로 달Of줌으 로써 안테니의 인덕턴스훌 훌여주는 효과훌 얻올 수 있다 안테나에 흐르는 전류룰 측정하기 위해서 사 각형 루프로 전류 픽업 코일을 만들었고 진공상태에서 RF 파워률 인가하고 안테나의 전류와 전압을 측정하여 픽업 코일걸과훌 조정하였다. 발생기체로는 헬륨올 사용하였고 1-100mTorr 의 압력범위에서 실험을 하였다 플라즈마롤 빌샘시키고 파워를 증가 시킴에 따라 E-H mode transition 현상이 관찰되었고 그 때의 임계 전류 값을 측정하였다. 압력이 낮올수록 모드 변화가 일어나는 전류의 값이 작았다 임계 전류는 압력에 대해서 선형적인 특성을 보였다 이는 압력이 낮을수록 유도걸힘이 더 잘 된다는 것을 의미한다 1 1 mTorr에서는 H-mode에서 안테나의 전류가 파워훌 증가시킴에 따라 계속 증가하였으니, 압력이 올라 갈수록 조금씩 증가하는 정도가 줄어들고. 100mTorr에서는 포화된 값을 나타냈다 H-mode로 넘어간 후 에는 파워가 증가황에 따라 안테나의 임피던스 값이 모든 압력영역에서 줄어드는 경황을 보였고, 이는 플라즈마의 인덕턴스에 의해서 안테나의 인덕턴스 기 감소되기 때문이다, 파워가 증가할수록 안테U오} 플라즈마 루프사이의 상호걸합이 증가하는 걸로 해석힐 수 있다 안테나의 인되턴스 변화보다는 저항.성 분의 변화가 컸다 하지만 전체 임피던스로 볼 때 저항성분이 상대적으로 작기 때문에 인덕턴스의 감소 가 더 큰 영향을 미치는 걸로 볼 수 있다. 하지만 플라즈마로의 파워 전달에는 저항성분만이 영향올 미 치므로 저항성분의 큰 변화는 파워가 많이 전달될올 의미한다 피워전달 효율을 계산해 본 결과 수 r mTorr 부근이 80-90% 정도의 높은 효율올 보였고 5mTorr 일 때가 가장 좋았다.

  • PDF

Effect of Desorption Pressure on Adsorption and Desorprtion Breakthrough Behaviors of Carbon Dioxide with Zeolite 3A, 4A, 5A, and 13X Pellets (제올라이트 3A, 4A, 5A, 13X 펠렛의 탈착 압력에 따른 이산화탄소 흡·탈착 파과특성)

  • Sim, Jungbo;Noh, Young-Kyoung;Park, Young Cheol;Kim, Hyunuk;Ryu, Ho-Jung;Cho, Churl-Hee;Moon, Jong-Ho
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.179-188
    • /
    • 2014
  • The effect of desorption pressure on $CO_2/N_2$ breakthrough behaviors for 4 different adsorbents was studied at a fixed bed. Zeolite 3A, 4A, 5A, and 13X pellets were used as adsorbents. Cyclic operations were executed with varying desorption pressure from vacuum (0 bar) to 3 bar while other conditions such as adsorption step pressure (3 bar), temperature (293 K), composition ($CO_2:N_2=10:90$vol%) and flow rate (400 ccm) were fixed at constant values. Each adsorption and desorption step was set as 80 min, which totaled up to 160 min per a cycle. 5 cycles with adsorption and desorption steps were run overall. After the experiment, breakthrough time, saturation time, and adsorption amount were measured and compared in order to find an optimum adsorbent and a proper operating condition for a post combustion $CO_2$ capture process.

The Evaluation of Seepage Characteristics in Reinforced Embankment Constructed on Low Permeable Clay Layer Through Centrifuge Model Tests (원심모형실험을 활용한 투수성이 낮은 기초지반에 위치한 보축 제방에서의 침투 거동)

  • Jin, Seok-Woo;Choo, Yun-Wook;Kim, Young-Muk;Kim, Dong-Soo;Im, Eun-Sang
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.27-39
    • /
    • 2012
  • In this paper, a series of centrifuge tests were performed to evaluate the seepage characteristic of reinforced embankment. The centrifuge models simulated an actual embankment reinforced by enlargement of levee cross-section. The centrifuge models have the same conditions except the locations of enlargement with low permeable material : water-side and land-side. In addition, the prototype embankment is constructed on low permeable clay layer. In the case of water-side reinforcement, the reinforced zone makes water head down and the saturated zone of embankment propagates slowly. In the case of land-side reinforcement embankment, the saturated zone enlarged relatively faster but the amount of exit water at land-side toe was very small because of the land-side reinforcement zone. The low permeable clay foundation layer was being continuously saturated by the inflow from the embankment as well as the uplift flow from the permeable layer induced by the excess pore water pressure.

Optimum Design Scheme of Receiver Dryer in an Automotive Air-Conditioning System using HFC-134a Refrigerant (신냉매용 자동차 에어콘 시스템에서의 건조기 설계에 관한 연구(온도감응식 팽창밸브의 개도에 따른))

  • 송유호;김령훈;송영길
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.6
    • /
    • pp.187-195
    • /
    • 1996
  • Because an alternative refrigerant(HFC-134a) is being used instead of CFC-12 for automotive air-conditioning system, newly designed air-conditioning components are necessary due to changes in characteristics. Optimum design scheme for receiver dryer in an automotive air-conditioning system is described with emphases upon the volume of desiccant and container. The volume of the container, that is manufactured based on the study, is reduced down to one half of the existing receiver dryers.

  • PDF