• Title/Summary/Keyword: 포화압력

Search Result 207, Processing Time 0.025 seconds

Thermodynamic Empirical Equations for Physical Properties of Inert Gas Mixtures (불활성 기체 혼합물의 물성에 관한 열역학적 실험식)

  • 김재덕;여미순;이윤우;노경호
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.43-49
    • /
    • 2003
  • For the inert gases of Ar, $N_2$and $CO_2$, the empirical equations of the gas mixture were correlated in terms of saturated pressure, density and viscosity. They were obtained by regression analysis based on the mixing rule. The empirical equation of saturated pressure was assumed as the first order function of temperature. The empirical form of density was expressed as compressibility factor and saturated pressure while the empirical equation of viscosity was formulated as a power function of temperature. This empirical equations of the physical properties were obtained in the composition of Ar, $N_2$and $CO_2$, 40/50/10(mol. %).

Empirical Equations for Thermodynamic Physical Properties of Freon-23 and HFC-227ea (Freon-23과 HFC-227ea의 열역학적 물성에 관한 실험식)

  • 김재덕;이윤우;송명석;노경호
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.16-25
    • /
    • 2002
  • For Freon-23, a conventional extinguished agent regulated by Montreal Protocol and HFC-227ea, its alternative, the empirical equations were correlated in terms of saturated pressure, density, viscosity, enthalpy and surface tension. They were obtained by regression analysis from the experimental data in the literature. The empirical equations of saturated pressure were expressed as the second and third order function of temperature. The empirical equation of density was expressed as compressibility factor and saturated pressure by a function of temperature. The empirical equation of viscosity was formulated as a power function. Heat capacities as well as enthalpies were well fitted by empirical form of the second-order temperature. Finally, surface tension simply has linear function form in terms of temperature.

Processing of Polyurhane Microcellular Foam for Thermal Insulation (단열재용 폴리우레탄 미세포 포움의 가공)

  • 윤재륜
    • The Korean Journal of Rheology
    • /
    • v.9 no.4
    • /
    • pp.190-199
    • /
    • 1997
  • 단열용도의 폴리우레탄 미세포 포움의 가공에 대한 연구를 수행하였다. 미세포 구조 를 얻기 위해서는 핵생성율을 증진시키고 균일한 분포의 기포를 생성시켜야 한다. 이를 위 해 이산화탄소 기체를 풀리올과 이소시아네이트에 각각 과포화시키고 충돌혼합하여 초음파 가진을 적용하였다. 이산화탄소 기체가 수지 내부에서 기포 내부로 확산함에 따라 기포의 성장이 조절된다고 가정하고 금형이 충전되는 동안에 금형 내부에서의 기포성장기구를 이해 하기 위하여 수치적인 방법으로 이론적 연구를 수행하였다. 경화 시간과 확산 경계를 고려 하여 최종적인 기포의 크기를 계산하였으며 반응속도론을 고려하여 중합반응동안의 폴리우 레탄의 점도의 변화를 예측하고 경화 시간을 결정하였다. 실험적으로 결정된 기체 분자수를 기준으로 하여 이론적으로 확산경계를 예측하였다. 화학적 발포제인 물과 함께 물리적 발포 제인 이산화탄소를 각각 1,2,3기압의 포화압력으로 변화시키면서 폴리올과 이소시아네이트에 포화시켜 폴리우레탄 포움을 제작하고 제작된 포움의 밀도, 열전도도, 및 기포의 수와 지름 을 측정하였다. 측정된 결과로부터 이산화탄소의 포화압력과 초음파 가진이 포움의 기포핵 생성에 미치는 영향을 살펴보았다.

  • PDF

Calculation of Gas Hydrate Saturation Within Unconsolidated Sediments (미고결 퇴적층내 가스하이드레이트 포화도 계산)

  • Kim, Gil-Young
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.2
    • /
    • pp.102-115
    • /
    • 2012
  • The purpose of this paper is to review several different methods calculating gas hydrate saturations. There are three methods using downhole log data, core data (including pressure core), and seismic velocity data. Archie's equation using electrical resistivity of downhole log data is widely used for saturation calculation. In this case, Archie's parameters should be defined accurately. And the occurrence types of gas hydrate significantly affect to saturation calculation. Thus saturation calculation should be carefully conducted. The methods using chlorinity and pressure core data are directly calculated from core sample. So far, the saturation calculated from pressure core gives accurate and quantitative values. But this method is needed much more time and cost. Thus acquisition of the continuous data with sediment depth is realistically hard. The recent several results show that the saturation calculated from resistivity data is the highest values, while the value calculated from pressure core is the lowest. But this trend is not always absolutely. Thus, to estimate accurate gas hydrate saturation, the values calculated from several methods should be compared.

Measurements of Saturation Energy Denity and Small Signal Gain Coefficient Dependent on the Active Gas Pressure in XeCl Laser Amplifier (XeCl 레이저 증폭기의 활성기체 압력에 따른 포화 에너지 밀도와 소신호 이득계수 측정)

  • 김규옥;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.457-460
    • /
    • 1994
  • Dependence of saturation energy density and small signal gain coefficient on the active gas pressure in XeCl laser amplifier has been investigated. The saturation energy density was increased almost linearly as 1.3, 1.45, 2.0, and $2.3mJ/\textrm{cm}^2$ when the pressure of Xe and He were 30 and 2000 mb, and the pressure of HC] was varied as 34, 52, 73, and 92 mb. Whereas the small signal gain coefficient was measured to be 6.5, 7.5, 7.0, 7.0 %/cm, which shows that the small signal gain did not varies not so much.o much.

  • PDF

Saturation Prediction of Bentonite Buffer in a Waste Disposal Repository (처분터널 내 벤토나이트 완충재 포화예측)

  • Kim, Jin-Seop;Lee, Chang-Soo;Jo, Won-Jin;Choi, Young-Chul;Choi, Heui-Joo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.361-362
    • /
    • 2014
  • 본 연구의 목적은 벤토나이트 완충재를 처분공에 설치하였을 때 벤토나이트와 암반의 상호작용을 중심으로 이의 포화과정을 제대로 모사할 수 있는 지와, 현장암반의 절리가 수치해석 결과에 어떠한 영향을 미치는가를 파악하는 것이다. 유한차분 해석코드인 TOUGH2 코드를 이용하여 벤토나이트의 수리거동을 분석하였다. 해석결과 암반의 절리가 존재할 경우 완충재의 포화도는 상대적으로 매우 빠르게 진행되었으며, 벤토나이트의 높은 모세관 압력으로 인해 시간경과에 따라 주변암반의 포화도가 점진적으로 감소됨을 확인하였다.

  • PDF

The Effects of Ar Gas Pressure on Thin Films Prepared by dc Magnetron Sputtering (DC 마그네트론 스퍼터링으로 제작된 NiFe 박막에서 Ar 압력이 자기 및 자기저항 성질에 미치는 영향)

  • 민병철;신성철
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.2
    • /
    • pp.98-105
    • /
    • 1996
  • 스퍼터링 방법으로 제작된 NiFe 박막에서 Ar 압력이 자기 및 자기저항 성질에 미치는 여향을 조사하였다. 타겟으로는 Ni$_{81}$$Fe_{19}$ 조성의 합금타겟을 사용하였다. TEM을 써서 박막의 미세구조를 조사하였으며, 보자력과 포화자화는 VSM으로 측정하였다. 합금박막의 조성은 ICPS로 분석 확인하였다. 10 mTorr 이상의 높은 Ar 압력에서 제작된 박막에서 갈라진 틈새(crack-like void)를 갖는 주상구조가 관찰되었다. 이러한 주상 결정립경계(columnar grain boundary)가 자화 과정에서 자구벽 핀닝자리(pinning site)가 되어, Ar 압력이 커짐에 따라 보자력이 증가 하였으며, 박막의 밀도가 감소하여 포화자화가 줄어드는 것을 볼 수 있었다. 한편, Ar 압력이 증가하면서 자기저항비가 감소하는 결과를 얻었다. 결정립 경계 산란과 결정립간 터널링에 의한 박막의 비저항의 증가가 이러한 자기저항비 감소의 주원인임을 알 수 있었다.다.

  • PDF

An Experimental Study on the Effect of Low Fin Tube Geometry on Pool Boiling of a LiBr Solution (낮은 핀관의 형상이 LiBr 수용액의 풀 비등에 미치는 영향에 대한 실험적 연구)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.591-598
    • /
    • 2015
  • Pool boiling heat transfer coefficients of a LiBr solution were obtained for seven low fin tubes having different fin pitch and fin height. The test range covered saturation pressure from 7.38kPa to 101.3kPa, heat flux from $20kW/m^2$ to $40 kW/m^2$ and LiBr concentration from 0% to 50%. The optimum fin geometry for the present experimental range turned out to be 26 fpi with 0.18 mm fin height.The advantage of added heat transfer area and the disadvantage of slower bubble growth and departure appear to have yielded an optimum fin pitch. The heat transfer coefficient decreased as saturation pressure decreased and Libr concentration increased. The reason may be attributed to the low saturation pressure, which increased the bubble departure diameter and decreased the bubble departure frequency. As the LiBr concenreation increased, the saturation temperature increased and the mass diffusion rate decreased, which resulted in a reduced heat transfer coefficient. The heat transfer coefficients of the low fin tube were greater than those of the smooth tube. Correlations were developed based on the present data.

Analysis of z-axis direction of the ion saturation current to the pressure of the process gas in the ICP system (ICP system에서 공정가스와 압력에 따른 z축 방향의 이온포화 전류밀도 변화 분석)

  • Kim, Dong-Hun;Ju, Jeong-Hun;Kim, Seong-Bong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.280-280
    • /
    • 2015
  • 플라즈마 진단법 중 내부에 삽입하여 측정하는 단일 랭뮤어 탐침법은 플라즈마 특성을 정확하게 측정할 수 있다. 탐침에 (-)극을 걸어서 들어오는 전류를 통해서 이온포화 전류밀도를 측정할 수 있다. 본 연구에서는 유도결합플라즈마에 흐르는 가스와 압력에 따라서 변화를 확인하였다. $H_2$, Ar, $CF_4$ gas로 10 mTorr, 70 mTorr, $CF_4$ 주입위치의 조건으로 플라즈마 밀도를 구하였다.

  • PDF

진공 챔버내 수분 잔류시 챔버 내부 압력 변화에 대한 고찰

  • Jo, Hyeok-Jin;Im, Seong-Jin;Go, Tae-Sik;Park, Seong-Uk;Seo, Hui-Jun;Mun, Gwi-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.121.1-121.1
    • /
    • 2013
  • 인공위성 및 우주발사체가 해당 궤도 및 고도에서 정상적으로 기능을 수행할 수 있는지 확인하기 위해 진공챔버 내부에 시험 대상을 설치하고 내부 압력을 낮추어 해당 궤도와 고도를 모사하게 된다. 반복적인 진공 시험을 수행하다 보면, 진공 챔버 내에 인지하지 못한 수분이 잔류하는 경우가 발생하는데, 이 때의 챔버 내부 압력 변화는 수분이 존재하지 않는 경우와는 매우 다른 양상을 보인다. 본 연구에서는 진공챔버 내부에 수분이 존재하는 경우를 모사하여, 포화증기압에서 액체의 잠열 이상으로 외부로부터 열을 받는 구간과 그렇지 못한 경우에 대한 현상을 살펴보고 이에 따른 챔버 내부 압력 변화에 대해 고찰하였다.

  • PDF