• Title/Summary/Keyword: 폐색장치

Search Result 58, Processing Time 0.024 seconds

Prosthetic rehabilitation for patient with hemi-maxillectomy: Obturator combined with a hybrid telescopic double crown using friction pin (편측 절제된 상악골 환자에서 하이브리드 텔레스코픽 이중관 의치를 이용한 구강 폐색기 수복 증례)

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.317-323
    • /
    • 2018
  • When oral cancer develops in the maxilla, oro-nasal communication occurs after surgical treatment including removal of the primary site. Restoration through an obturator is necessary to prevent food from storing due to non-oral opening, and to ensure proper pronunciation and aesthetic restoration. In this case, the patient was treated with right hemi-maxillectomy due to oral cancer and has residual abutment and poor periodontal support due to the effect of head and neck radiotherapy. The obturator was treated with a hybrid telescopic double crown denture. Reporting a successful prognosis in 18 months of follow-up.

Analysis of Operational Issues for ICT-based On-Board Train Control System (ICT 기반 차상제어시스템 개발에 따른 운영 이슈 분석)

  • Kim, Young-Hoon;Choi, Won-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.575-583
    • /
    • 2011
  • In order to minimize the maintenance cost at local lines, Information & Communication Technology based onboard train control system is being developed. Unlike the central traffic control based fixed block system, this system use a moving block method and railway driver direct control switch and railway crossing. The purpose of this paper is to analyze the concerned main operational issues are as follows: the preparation of train operation, drivability, the role of driver and controller, block system and cost. We defined the role of driver and driver's input data for train service, and we designed the business process of driver using UML tool. We considered the aspect of drivability, DMI is needed to support the braking moment for the driver and driver training simulator. We designed the driver business process for control of switch and railway crossing. We analyzed the fixed block system and moving block system to confirm the difference with the existing operational method. The cost analysis structure is also needed for the operation cost comparison.

Prosthetic rehabilitation of soft palate resection edentulous patient with maxillary obturator (무치악 연구개 결손 환자에서 총의치형 연구개 폐색 장치를 제작한 증례)

  • Ryu, Seung-Beom;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.475-482
    • /
    • 2019
  • This report is a case of 76-year old male patient who had difficulty in swallowing, pronunciation and suffered regurgitation of food. The patient lacks uvula and both tonsils, had short palatoglossal arch and soft palate, as well as defective left palatopharyngeal arch. The height and width of the soft palate defect were measured by reconstructing the Computed Tomography (CT) image in three dimensions. Phonation and soft palate obstructing ability were examined by nasometry and nasal endoscopy. Evaluations on phonetics and swallowing were done and improvements were shown. The patient was satisfied with the results of treatment.

The $Outback^{(R)}$ $LTD^{TM}$ Catheter: The Novel Re-Entry Technique in Recanalization of Chronic Inflow Occlusion of the Superficial Femoral Arteries in 3 Cases ($Outback^{(R)}$ $LTD^{TM}$ Catheter를 이용한 표재성 대퇴동맥의 만성동맥폐색증의 성공적인 재개통술: 3예 보고)

  • Kong, Joon-Hyuk;Hur, Jin;Kim, Duk-Sil;Kim, Sung-Wan
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.785-789
    • /
    • 2010
  • The acute technical failure of endovascular treatment of chronic total occlusions is most often due to the inability to re-enter the true lumen after occlusion is crossed in a subintimal plane. True lumen re-entry catheters are very effective at gaining wire passage back to the true lumen and facilitating successful endovascular treatment of chronic total occlusions that would otherwise require open bypass. These case reports describe our initial experiences with a new catheter system (the $Outback^{(R)}$ $LTD^{TM}$ catheter) that is designed to allow fluoroscopically controlled re-entry of the true arterial lumen after subintimal guidewire passage during recanalization procedures of arterial occlusions.

Transarterial Coil Embolization in Two Maltese Dogs with Patent Ductus Arteriosus Using a Mini Cobra-tip Angiocatheter (말티스 견에서 시술된 미니코브라 카테터와 코일을 이용한 동맥관 개존증의 치료 2 증례)

  • Han, Dong-Hyun;An, Hyo-Jin;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.740-745
    • /
    • 2010
  • Patent ductus arteiosus (PDA) is the persistent opening of ductus arterious located between pulmonary artery and descending aorta after birth. Although PDA can be occluded by surgical ligation, interventional closure of PDA using various devices is being rapidly replaced to surgical ligation, because of its non-invasive nature of treatment and minimal post-care after treatment. Main problem encountering in interventional treatment in toy breed dogs is vascular inaccessibility due to small size of artery. Although transvenous approach using jugular veins has been developed, this technique requires experienced skill to locate occlude devices into PDA and has high risk of accidental dislodgement of occluding devices (i.e. embolization coils or vascular plugs). Therefore, in this study, we developed a modified technique for coil embolization using mini-angiocatheter with trans-femoral approach in toy breed dogs (< 3.0 kg of body weight). With this modified method, we were successfully treated two toy breed (Maltese) dogs with the left to right shunted PDA.

A study on the availability of ATS system in speed augmentation (속도 향상시의 ATS 시스템 가용성 연구)

  • Kim, Yong-Kyu;Baek, Jong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.238-240
    • /
    • 2004
  • 현재 우리나라에서 사용 중인 신호시스템은 지상신호 방식인 자동폐색장치(ABS)를 사용한다 이는 선로를 패색구간으로 배분한 후, 각각의 패색 구간에 설치된 신호기에 의해 열차의 이동을 실행한다 이러한 신호체계에 문제점이 발생할 경우, 기관사에게 주의를 환기시켜 강제적으로 열차를 정지시키는 역할을 하는 자동열차정지장치(ATS)가 1969년부터 도입, 사용 중에 있다. 본 논문에서는 ATS 시스템의 고속, 고밀도 운전 적용 가능성 및 차상신호방식 사용시의 ATS 적용 가능성에 대해 분석한다.

  • PDF

Boundary Noise Removal in Synthesized Intermediate Viewpoint Images for 3D Video (3차원 비디오의 중간시점 합성영상의 경계 잡음 제거 방법)

  • Lee, Cheon;Ho, Yo-Sung
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.109-112
    • /
    • 2008
  • 최근 MPEG(moving picture experts group)에서 표준화를 진행하고 있는 3차원 비디오 시스템은 다시점 영상과 깊이영상을 동시에 이용하여 사용자가 임의의 시점을 선택하거나 스테레오스코픽 장치와 같은 3차원 영상 재생장 치를 동해 3차원 영상을 제공하는 차세대 방송 시스템이다 제한된 시점수를 이용하여 보다 많은 시점의 영상을 제공하려면 중간시점의 영상을 보간하는 장치가 필수적이다. 이 시스템의 입력정보인 깊이값을 이용하면 시점이동을 쉽게 할 수 있는데, 보간한 영상의 화질은 이 깊이값의 정확도에 따라 결정된다. 깊이맵은 대개 컴퓨터 비전을 기반으로 한 스테레오 정합기술을 이용 획득하는데, 객체의 경계와 같은 깊이값 불연속 영역에서 주로 깊이값 오류가 발생하게 된다. 이런 오류는 생성한 중간영상의 배경에 원치 않는 잡음을 발생시킨다. 기존의 방법에서는 측정한 깊이법의 객체 경계와 영상의 객체 경계가 일치한다는 가정으로 중간영상을 합성했다. 그러나 실제로는 깊이값 측정 과정에서 두 가지 경계가 일치하지 않아 전경의 일부분이 배경으로 합성되어 잡음을 발생하는 것이다. 본 논문에서는 깊이맵을 기반으로 중간시점의 영상을 보간할 때 발생하는 경계 잡음을 처리하는 방법을 제안한다. 중간영상을 합성할 때 비폐색 영역을 합성한 후 경계 잡음이 발생할 수 있는 영역을 비폐색 영역을 따라 구별한 다음, 잡음이 없는 참조 영상을 이용함으로써 경계 잡음을 처리할 수 있다. 실험 결과를 통해 배경 잡음이 사라진 자연스러운 합성영상을 생성했다.

  • PDF

A CASE REPORT OF OPEN TYPE HOLLOW OBTURATOR (개방형 Hollow 폐색장치의 임상 증례)

  • Chung, Moon-Kyu;Bae, Jeoung-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.207-212
    • /
    • 1988
  • Maxillary defects are a result of necessary cancer surgery, congenital anomaly or trauma. Ideally the patient with the aquired maxillary defect should be provided with an obturator prosthesis that is comfortable, restores adequate speech, deglutition, and mastication, and is acceptable cosmetically. This is a case report of open type hollow obturator delivered in the partial maxillectomy treated patient. The satisfied result obtained as follows: The open type hollow obturator has the advantage of easy fabrication, lightness, easy cleaning and restores adquate speech.

  • PDF

극초음속 추진기관 고공 모사 설비의 시험부 설계를 위한 시험모델의 변수에 따른 성능 특성연구

  • Choe, Ji-Seon
    • Proceeding of EDISON Challenge
    • /
    • 2016.11a
    • /
    • pp.63-67
    • /
    • 2016
  • 본 연구에서는 극초음속 추진기관을 위한 고공환경 모사 설비 장치에서 시험부 안에 들어가는 시험 모델의 변수에 대해 고찰하였다. 시험부에 적용할 시험 모델을 대상으로 진행하고, 시험 모델 형상 변화에 따른 유동 특성을 파악하였다. 시험 모델에 대한 주요 변수는 폐색율, 각도, 받음각으로 설정하였으며, 해석은 EDISON_CFD에서 제공하는 정렬격자 기반 2차원 압축성 유동 범용 해석 SW로 진행하였다. 해석 결과를 통해 다양한 형상 변수에 따라 변화 되는 충격파 뒤의 압력층 두께를 확인 하였고, 압력층 두께가 두꺼워 질수록 시험 조건을 모사 할 수 없음을 확인하였다. 본 연구를 통해 형상 변수에 따른 극초음속 추진기관을 위한 고공모사설비에서 시험부에 적용될 시험 모델의 범위를 확인하였다.

  • PDF

안목항 방파제 건설로 인한 연안 토사 이동경향의 변화

  • 김인호;이정렬
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.490-495
    • /
    • 2004
  • 안목항의 방파제 확장 건설로 인하여 항남측에 심각한 침식현상이 광범위하게 발생하고 있는 데 이를 규명하기 위하여 현재 주변 해안선 변형 현상을 기초로 연안 표사 이동(littoral drift)도를 정성적으로 작성하였으며 수치 모형실험을 통하여 상세할 표사이동의 변화를 살펴보았다. 수치모형 실험은 파랑 변형 및 해빈류 예측 모형인 WADEM-P, DISEM-R로 수행되었다. 항 내 매몰 및 하천 폐색을 근본적으로 해결하면 해안선 침식문제를 완화 시 킬 수 있는 장치로서 모래운송장치(sand transfer)의 필요성이 언급되었으며 앞으로 연안 표사량이 많은 동해안에서의 항만 건설시 꼭 필요한 부대장치임을 강조한다. 또한 주기적인 연안관측 프로그램을 수립하여 연안 표사량 및 해안 침식율을 산정한 후 모래이송장치의 설치 여부 및 그 규모를 판단할 필요가 있다.

  • PDF