• Title/Summary/Keyword: 폐기물 연소

Search Result 290, Processing Time 0.033 seconds

A Study on Greenhouse Gas Inventories for Regional Governments (A Case Study of Jeonbuk Province) (지자체 온실가스 인벤토리 구축연구 - 전라북도 사례)

  • Jang, Nam-Jung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.565-572
    • /
    • 2009
  • Greenhouse gas(GHG) inventories and basic strategies for Jeonbuk regional government were established to reduce greenhouse gas emissions. The method to construct GHG inventories of Jeonbuk followed the 'Revised IPCC 1996 Guidelines'which was used for the 'Third National Communication of the Republic of Korea under UNFCCC'. Korean government could use primary energy consumption for the energy industries section in the national GHG inventories. However, regional governments should use secondary energy consumption (included electricity consumption) for the energy industries section for their GHG inventories because they could not control the emission of energy transformation section. In the result of Jeonbuk GHG inventories in 2006, carbon dioxide($CO_2$) emissions from fuel combustion covered 87.1% of total emissions. Methane($CH_4$), carbon dioxide($CO_2$) from other sections, nitrous oxide($N_2O$) and F-gas(HFCs, PFCs, $SF_6$) accounted for 8.1, 2.2, 1.6 and 1.0% of total emissions, respectively. The sectional emission decreased in the order of the energy(88.0%), agriculture(7.6%), waste(2.3%) and industrial processes(2.1%) section. The energy industries section that contained electricity consumption was the most dominant emission source in the energy section. F-gas consumption, rice cultivation and waste incineration were main emission sources in the industrial processes, agriculture and waste section, respectively. In this study, basic directions of each section were established by the results of Jeonbuk GHG inventories in 2006.

Development of a Simplified Source Term Estimation Model for a Spent Fuel from Westinghouse-type Reactors (웨스팅하우스형 원전 사용후핵연료에 대한 방사선원항 예측 모델 개발)

  • Cho, Dong-Keun;Kook, Dong-Hak;Choi, Heui-Joo;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.239-245
    • /
    • 2010
  • There are 11,811 LWR spent fuels stored at reactor sites, as of 2009. Source terms based on reference spent fuel which represents entire spent fuels with bounding values in the aspect of source term has been applied to a design of nuclear installations, instead of those which are generated by weighting respective source term for each spent fuel. Simplified regression models to estimate total decay heat, radioactivity, and ingestion hazard index for spent fuel from Westinghouse-type reactors were developed in this study, because it can be used as a fundamental model for weighting source term for respective spent fuel to exclude conservativeness in source terms. It was found that the estimated source terms agreed with calculated value from ORIGEN-ARP within 5%. It was also found that the conservativeness could be excluded if the weight source terms were used as reference source term in the design. Therefore, it is expected that the developed regression model could be widely used in the conceptual design process of nuclear facilities related with storage and disposal of spent nuclear fuel.

Study on Characteristics of Change of Physical/Chemical property of Refined Fuel Oil(Reduced-pressure) by Mixing with By-product Fuel Oil(No. 2) (부생연료유(2호) 혼합에 따른 정제연료유(감압)의 물성 변화 특성 연구)

  • Doe, Jin-woo;Lim, Tae-yun;Yim, Eui-soon;Lee, Joung-min;Kang, Hyung-kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1349-1358
    • /
    • 2018
  • In addition to responding to the environmental pollution caused by fossil fuels, the enforcement of Renewable Fuel Standard(RFS) system has increased the utilization of renewable energy such as refined fuels oil. The by-product fuel oil(No. 2) and the refined fuel oil(reduced-pressure) are strictly regulated by the domestic legislation and the chemical property changes of the refined fuel oil(reduced-pressure) mixed with the by-product fuel oil(No. 2) were analyzed. As a result of analyzing the physical properties of refined fuel oil(reduced pressure) obtained by mixing 1 : 1 of by-product fuel oil(No. 2), it satisfied the quality standards stipulated by the domestic Enforcement Decree of the Wastes Control Act. However, the results of the additional tests related to the fuel showed a high aromatic content. The high content of aromatic in a fuel is likely to cause the soot and ehaust emission gas during the combustion of the used equipment.

Strength and Earth Pressure Characteristics of Industrial Disposal Flowable Filling Materials Utilizing Backfiller (뒤채움재로 사용된 산업폐기물 유동화 처리토의 강도 및 토압특성)

  • Bang, Seongtaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.3
    • /
    • pp.5-13
    • /
    • 2021
  • Due to population growth and industrial development, the amount of industrial waste is increasing every year. In particular, in a thermal power plant using finely divided coal, a large amount of coal ash is generated after combustion of the coal. Among them, fly ash is recycled as a raw material for cement production and concrete admixture, but about 20% is not utilized and is landfilled. Due to the continuous reclamation of such a large amount of coal ash, it is required to find a correct treatment and recycling plan for the coal ash due to problems of saturation of the landfill site and environmental damage such as soil and water pollution. In recent years, the use of a fluid embankment material that can exhibit an appropriate strength without requiring a compaction operation is increasing. The fluid embankment material is a stable treated soil formed by mixing solidifying materials such as water and cement with soil, which is the main material, and has high fluidity before hardening, so compaction work is not required. In addition, after hardening, it is used for backfilling or filling in places where compaction is difficult because higher strength and earth pressure reduction effect can be obtained compared to general soil. In this study, the possibility of use of fluidized soil using high water content cohesive soil and coal ash is considered. And it is intended to examine the flow characteristics, strength, and bearing capacity characteristics of the material, and to investigate the effect of reducing the earth pressure when applied to an underground burial.

Development of Composite RPF by mixing the sludge with plastic waste (슬러지와 플라스틱 폐기물을 혼합한 복합고형연료 개발)

  • Lee, Jangkun;Kim, Minsun;Roh, Seungmin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.206.2-206.2
    • /
    • 2010
  • 현재 RPF 생산공정에서 생산된 RPF는 약 7,500~8,500kcal/kg 의 높은 열량을 지니고 있다. 이러한 특성으로 연소시 소각로 내부의 온도가 부분적으로 급격히 상승하여 적정온도조절이 어렵고, 로내 장치들의 내구성이 저하되는 등 문제가 발생하고 있다. 또한, RPF에 포함된 비교적 높은 농도의 염소 함량(0.8~1.8% wt)으로 인해 다량의 대기오염물질이 발생되는 단점이 나타나고 있다. 따라서, 이러한 문제점들을 개선하기 위해 RPF의 개질이 필요하며 본 연구에서는 슬러지와 RPF를 혼합하여 열량, 성형성, 염소함량등을 고려하여 최적의 혼합비율을 선정하였다. J하수처리장에서 발생하는 하수슬러지를 이용하여 5, 15, 25, 30, 35%를 RPF 성형공정에 혼합하여 실험하였다. 5% 혼합시 발열량은 약 6,300~6,800kcal/kg, 염소농도는 0.8~1.6%(wt), 15% 혼합시 발열량은 5,500~6,000kcal/kg, 염소농도는 0.7~1.4%(wt), 25% 혼합시 발열량은 5,200~5,900kcal/kg, 염소농도는 0.6~1.1%(wt), 30% 혼합시 발열량은 5,000~5,700kcal/kg, 염소농도는 0.6~1.0%(wt), 35% 혼합시 발열량은 4,800~5,200kcal/kg, 염소농도는 0.4~0.6%(wt)으로 나타났다. 각 혼합비율에서 관찰된 성형성은 5~25% 혼합까지는 성형된 RPF와 유사하게 일정한 크기 및 강도를 유지 할 수 있었으나, 25% 이상 혼합시 분말형태의 가루가 많이 발생되며 강도가 약해져 쉽게 부스러지는 문제점등이 나타났다. 연료의 개질 형태나 성형성등을 고려하였을 때 슬러지 혼합비율이 약 15~25% 정도가 최적 혼합비율인 것으로 나타났다.

  • PDF

High functional biodegradable card through annealing (어닐링을 통한 고기능성 생분해성 카드)

  • Sim, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.280-286
    • /
    • 2020
  • Cards made from PVC and PET materials do not oxidize or decompose readily, so they are generally incinerated or landfilled after use and cause pollution problems, such as environmental hormones and combustion gases during incineration. In addition, there is a problem of environmental pollution because they are discarded as semi-permanent refuse without being decomposed at landfill. This study attempted to solve this problem using polylactic acid (PLA), which is a representative biodegradable material as a substitute material that can solve the issues with these cards. On the other hand, when the thin card core sheet is made from only PLA material, the physical properties of the material are insufficient, such as the low temperature impact strength, high temperature stability, and poor bending properties, so its use is limited. To solve this problem, the compositional ratio of PLA was reviewed, and the optimal biodegradable compound composition was determined through an examination of the compositions, such as crystallization nucleating agents, additives, and nano compound technology. The high functionalization as a biodegradable card was verified through a laminating process using annealing technology.

Potential Element Retention by Weathered Pulverised Fuel Ash : II. Column Leaching Experiments (풍화 석탄연소 고형폐기물(Pulverised Fuel Ash)의 중금속 제거가능성 : II. 주상용출실험)

  • Lee, Sanghoon
    • Economic and Environmental Geology
    • /
    • v.28 no.3
    • /
    • pp.259-269
    • /
    • 1995
  • Column leaching tests were conducted using fresh and weathered pulverised fuel ash of some 17 and 40 years old from two major British power plants, with deionised water and simulated synthetic industrial leachate. The former was to see the leaching behaviour of weathered ash and the latter was to see if the formation of secondary products from water and PFA interaction and ameliorating effect in removing metals from industrial leachates. Fresh PFA liberates elevated concentrations of surface-enriched inorganics, including Ca, Na, K, B, $Cr_{total}$, Li Mo, Se and $SO^{2-}_4$. This might indicate their association with the surface of PFA particles. In the column leaching tests using weathered ash and deionised water, elements are not readily leached but are released more slowly, showing relatively constant concentrations. For the case of weathered ash, some readily soluble surface-enriched elements appears to have been liberated in their early stage of leaching and the liberation of glass associated elements are thought to be more important function in controlling the element concentration. The result from column leaching tests exceed for a number of elements when compared with various Water Standards and suggests the leachate from PFA disposal mound needs dilution to achieve target concentrations. PF A shows element retention effect for many elements, including B, Fe, Zn, Hg, Ni, Li and Mo, in the order of fresh Drax ash > weathered Drax ash > Weathered Meaford ash in retaining capacity. Geochemical modelling using a computer program WATEQ4F reveals some solubility controlling secondary solid products. These include $CaSO_4{\cdot}2H_2O$ for Ca, $Al(OH)_3$ for Al and $Fe(OH)_3$ for Fe.

  • PDF

Products and pollutants of half dried sewage sludge and waste plastic co-pyrolysis in a pilot-scale continuous reactor (반 건조 하수슬러지와 폐플라스틱 혼합물의 파일롯 규모 연속식 열분해에 의한 생산물과 발생 오염물질)

  • Kim, YongHwa;Chun, Seung-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.327-337
    • /
    • 2017
  • A continuous low temperature ($510^{\circ}C{\sim}530^{\circ}C$) pyrolysis experiment in a pilot-scale of 85.3 kg/hr was carried out by the mixed feedstock of half dried digested sewage sludge and waste plastics. As a result, the amount of pyrolysis gas generated was maximum 68.3% of input dry mass and scored $40.9MJ/Nm^3$ of lower heating value (LHV), and the percentage of air inflow caused by continuous pyrolysis was 19.6%. The oil was produced 4.2% of the input dry mass, and the LHV was 32.5 MJ/kg. The sulfur and chlorine contents, which could cause corrosion of the facility, were found to be 0.2% or more respectively. The carbide generated was 27.5% of the input dry mass which shows LHV of 10.2 MJ/kg, and did not fall under designated waste from the elution test. The concentration of carbon monoxide, sulfur oxides and hydrogen cyanide of emitted flu gas from pyrolysis gas combustion was especially high, and dioxin (PCDDs/DFs) was within the legal standards as $0.034ng-TEQ/Sm^3$. Among the 47 water pollutant contents of waste water generated from dry flue gas condensation, several contents such as total nitrogen, n-H extract and cyanide showed high concentration. Therefore, the merge treatment in the sewage treatment plants after pre-treatment could be considered.

Process gas purification using cyclone recirculation and cooling process (싸이클론 재순환, 냉각공정을 이용한 공정가스 정제 연구)

  • Kim, Ju-Hoe;Jo, Woo-Jin;Choi, Young-Tae;Jo, Young-Min;Kim, Sang-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.25-33
    • /
    • 2018
  • Renewable energy has been of interests in the area of modern alternative fuels. Biogas is produced in waste landfill sites through anaerobic digestion processes, including hydrolysis, acidogenesis, organic acid fermentation (acetogenesis), and methane fermentation (methanogenesis). High contents of fine dust and moisture limited its utilization for direct combustion, town gas and vehicle fuel. Thus, this study proposed a new design for a cooling device using a centrifugal cyclone for simultaneous removal of fine dust and moisture as a pretreatment in the purification processes. A heat exchanger and an ID fan, which are installed inside and outside of the cyclone, in order to cool the humid gas below the freezing point and form a foggy mist. Such an atmosphere enhanced to capture fine dust as recirculating the cold mist flow. The water removal rate was 80.8% at a relative humidity of 95%, and the particle removal efficiency was 98.3% for $2.5{\mu}m$. Simultaneous removal efficiency was 70.8% and 99.6% for particle and moisture respectively.

Characteristics of Trace Element Concentrations in Dust by Facilities and Areas in Daegu, Korea (대구지역 축적먼지 중 미량원소성분의 시설별 및 지역별 농도분포)

  • Song, Hee-Bong;Do, Hwa-Seok;Kwak, Jin-Hee;Kim, Jong-Woo;Kang, Jae-Hyoung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.3
    • /
    • pp.287-295
    • /
    • 2010
  • Dust samples have been collected from streets, schools, subway stations and households in Daegu metropolitan city. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were influenced by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. In particular, school dust had higher levels of Ca and Pb and subway station dust had higher levels of Cu and Zn. The percentage composition of chemicals from subway stations, households, and schools were remarkably higher in components from anthropogenic sources than that from streets. It is well recognized that anthropogenic sources were affected by indoor dust. Results of pollution index of hazardous heavy metals indicated that schools, households, and subway stations were more contaminated than streets and urban areas typically had higher pollution index than rural areas. The correlation analysis among trace elements seem to suggest that there were correlations between components of soil/road dust resuspension, and components of waste incineration and fuel combustion.