• Title/Summary/Keyword: 폐기물소각

Search Result 442, Processing Time 0.022 seconds

Properties of Eco-Construction Material Using Recycled Sewage Sludge Ash (하수슬러지 소각재를 재활용한 친환경 건설 소재의 재료적 특성)

  • Jo, Byung-Wan;Lee, Jea-Ik;Park, Seung-Kook;Lee, Jae-Seung
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.667-676
    • /
    • 2007
  • As the 21st century began, cement and concrete that are representatives of modem building materials became a major factor in global warming, air pollution and environmental pollution. Also, the problems that are generated while pursuing high performance and high strength became social issues. Therefore, it has become urgent to prepare counter plans. This study has aimed at the recycling of sewage sludge ash and developing it as a new concept in building material which serves the environmental considerations for long-lasting developmental purpose. Also, the study aimed to find a substitute for scarce natural resources and to secure high techniques for waste recycling. The purpose of this study was also to solve fundamentally secondary environmental pollution. The results revealed that the chemical components of sewage sludge ash are mainly $SiO_2\;and\;Al_2O_3$ which are similar to the components of pozzolan. Also, it was identified that sewage sludge ash can be utilized as a hardened specimen with an alkali activated pozzolan reaction. Considering the possibility of appropriate strength development and the advantage of drying shrinkage, compared with that of cement, it was believed that sewage sludge ash can demonstrate a function as a substitute for cement given.

A Study on the PCDDs/PCDFs Contents in the Flue Gas of Muncipal Solid Waste Incinerator(III) -Emission Concentration Varying the Combustion Temperature- (쓰레기소각로 배출가스의 PCDDs/PCDFs 함유량에 관한 연구(III) -소각로 연소 온도변화에 따른 보일러 후단에서의 배출 농도 변화-)

  • Shin, S.K.;Chung, Y.H.;Lee, J.I.
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.540-549
    • /
    • 1999
  • The combustion temperature was controlled between $880^{\circ}C$ to $1070^{\circ}C$ to find the relation the combustion temperature and emission amount of PCDDs/PCDFs in the Municipal solid waste incinerator. The emission amount of PCDDs/PCDFs decreased when the temperature increased in the rear of the boiler. The PCDDs/PCDFs concentration were detected $7.82ng-TEQ/Nm^3$ at $880^{\circ}C$, $6.97ng-TEQ/Nm^3$ at $970^{\circ}C$ and $6.13ng-TEQ/Nm^3$ at $1070^{\circ}C$. Also, The chlorophenols, chlorobenzenes, and PCB concentration decreased by increasing the temperature from $880^{\circ}C$ to at $1070^{\circ}C$, and the isomer of the prescsors had a tendency to emit the higbly cbiorinated compounds.

  • PDF

The Properties of Permeability and Freeze-Thaw Resistance of Water-Permeable Paving Brick Using Wastes (폐기물을 이용한 투수블록의 투수성 및 동결융해저항 특성)

  • 신대용;한상목;김경남;이현종
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.3
    • /
    • pp.210-215
    • /
    • 2004
  • Porous ceramics for water-permeable paving brick was prepared by the sintering of mixed materials comprising of sewage sludge ash, waste porcelain fragment, waste glaze and low-grade clay at 1,000$^{\circ}C$ for 2 h, and the physical $.$mechanical properties, the permeability and the freeze-thaw resistance of specimens with preparation parameters were investigated. The physical mechanical properties were increased in specimens while porosity and permeability were decreased with increasing sewage sludge ash content and sintering temperature on the properties of specimens showed the opposite results. The bulk density, porosity, compressive strength and permeability (passed charge) of 30A60F specimens with 30 wt% of sewage sludge ash content, waste porcelain fragment size with 1∼2 mm and sintered at 1,000$^{\circ}C$ for 2 h were 2.17, 46.2%, 221 kgf/$\textrm{cm}^2$ and 3,150 coulombs, respectively. The permeability was increased with increasing waste porcelain fragment size, however compressive strength was decreased. The freeze-thaw resistance of 30A60F specimen with 1∼2 mm of fragment size was superior to that of the other specimens. The 30A60F specimens can be used for the water-permeable paving brick with the high permeability and adequate strength. The heavy metals included in the all specimens showed lower than the standard level.

Study on $CaCO_3$ Preparation from MSWI Fly Ash (생활쓰레기 소각(燒却)비산재로부터 $CaCO_3$ 제조(製造)에 관한 연구(硏究))

  • Choi, Woo-Zin;Park, Eun-Kyu
    • Resources Recycling
    • /
    • v.15 no.5 s.73
    • /
    • pp.47-51
    • /
    • 2006
  • The total amount of ash generated from the municipal solid waste incineration(MSWI) in Korea was approximately 420,000 tons in 2005 including 68,000 tons of fly ash. Fly ash from MSWI generally contains high amount of CaO (upto ${\sim}50%$) due to the treatment of flue gas by spraying CaO-base materials. Currently, most of fly ash generated is finally ended up with specially designed landfill sites and only less then 20% of fly ash is recycled. In the present work, preparation of $CaCO_3$ from the MSWI ny ash was studied to promote the fly ash recycling. Fly ash obtained from the dust collector in stoker-type MSWI is used to selectively dissolve CaO by using the sugar solution. Then, $CO_2$ gas was passed through the dissolved solution to pro- duce $CaCO_3$ powder. The optimum conditions for CaO dissolution were solid content 10%, reaction time 15 minutes, sugar concentration $10{\sim}15%\;and\;pH\;10.5{\sim}11.0$. The high grade $CaCO_3$ powder was obtained and the experimental conditions are also discussed.

Certification and Quality Control of the Official Test Facilities of Dioxins in Korea (국내 다이옥신 측정분석기관 지정 및 정도관리)

  • Jang, Seong-Ki;Kim, Tae-Seung;Lee, Won-Seok;Chung, Young-Hee;Choi, Doug-Il
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.675-682
    • /
    • 2000
  • The concentration of dioxins from flue gases of municipal waste incineration facilities with capacities over 50 tons/day are regulated by the guideline: $0.1ng-TEQ/Nm^3$ for new facilities, and $0.5ng-TEQ/Nm^3$ for existing facilities and it will be strengthened to $0.1ng-TEQ/Nm^3$ until 2003 year. Dioxins from these incineration facilities have to be measured more than 2 times annually by the Official Test Facilities of Dioxins. Seven institutions have been certified so far as the Official Test Facilities of Dioxins. These facilities have to be evaluated by the quality control program provided by National Institute of Environmental Research every year. We reported the results of quality control test performed in 1999. Four institutions certified in 1998 sampled flue gases at stack of M incineration facilitiy and analyzed dioxins by Official Methods of Air Pollution. The isokinetic coefficients, the parameter for evaluation of sampling ability were excellent for all four institutions. They were 100.9%, 102.4%, 102.1% and 99.2%, respectively. The criteria required are as follows; resolution over 10,000, mass calibration within ${\pm}5ppm$, ion abundance ratio within 15%, and the recovery of 50-120%. As results, those institutions also met these parameters of Official Method of Air Pollution.

  • PDF

Size Distribution and Physicochemical Characteristics of MSW for Design of Its Mechanical Biological Treatment Process (폐기물전처리(MBT)시설 설계를 위한 생활폐기물의 입도분포 및 물리화학적 특성에 관한 연구)

  • Park, Jin-Kyu;Song, Sang-Hoon;Jeong, Sae-Rom;Jung, Min-Soo;Lee, Nam-Hoon;Lee, Byoung-Chul
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.1
    • /
    • pp.62-69
    • /
    • 2008
  • There has been a recent trend in Korea that treatments for combustible wastes among municipal solid waste (MSW) by those methods, such as incineration and landfill are restricted as much as possible and Mechanical Biological Treatment (MBT) are encouraged actively in order to promote resource recovery. To build and operate properly these facilities, the physicochemical characteristics of MSW should be analyzed precisely beforehand. In particular, designing a crusher or separator properly which is the main process in MBT facilities of MSW. require the information on the size distribution characteristics of MSW, but they are nor sufficient in the qualities and quantities yet as of now. Accordingly, this study aims to evaluate size distribution characteristics of MSW and its physicochemical characteristics by size. The samples of MSW were collected from detached dwelling area, apartment area, business area, and commercial area of A city in Korea. According to the result of analysis, paper records 29.78~60.02% by wet weight basis, so it was the most regardless of the regions where the wastes were generated. And in terms of element analysis, Carbon(C) was 34.77~44.39%, the largest friction, and Oxygen(O) was the next occupying 19.46~33.71%. As indices of RDFs, Chlorine(Cl) was 0.39~0.83%, so it was less than the standard, 2.0%(by dry weight basis); moreover, Sulfur(S) did not exceed the standard, 0.6%, either. In the size distribution of MSW, waste fraction ranging 50~80mm in diameter was the most in combustible waste while 30~50mm was in incombustible waste.

  • PDF

Development of process for energy recovery from landfill gas using LFG-Hydrate (LFG-Hydrate를 통한 매립가스 에너지화 공정 개발)

  • Moon, Donghyun;Shin, Hyungjoon;Han, Kyuwon;Lee, Jaejung;Yoon, Jiho;Lee, Gangwoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.152.2-152.2
    • /
    • 2010
  • LFG는 매립된 폐기물 중 유기성분이 혐기성조건에서 미생물에 의해 분해가 되면서 발생하며, 이러한 매립지가스는 주변 지역의 자연 및 생활환경에 악영향을 미치기 때문에 소각 등의 방법으로 LFG를 처리하고 있다. 일반적으로 매립지로부터 발생하는 가스의 량은 폐기물 1톤 당 $150{\sim}250m^3$로서 매립 후 2~3년 후에 최대량이 발생하며 매립 후 20~30년 후까지 지속적으로 발생함으로 안정적인 LFG의 공급이 가능하며, 메탄함량이 50%인 경우 약 $5,000kcal/m^3$의 높은 발열량을 가지므로 대체에너지원으로 이용할 경우 환경적인 문제 해결 및 신재생에너지원으로 활용할 수 있다. LFG 자원화 할 경우 가장 안정적인 방안으로 발전 및 중질가스로 활용하는 것이나, 발전의 경우 최소 200만톤 이상의 매립용량을 갖추어야 경제적인 사업성을 확보할 수 있으며, 중질가스로 활용하는 경우 인근에 가스 수요처를 확보해야 하는 어려움이 있다. 만약 중 소규모의 매립장에서 발생하는 LFG를 안전하고 경제적인 조건으로 저장 및 수송할 수 있다면 중 소규모의 매립지에서 발생하는 LFG도 활용할 수 있을 것으로 기대되며, 안전하고 경제적인 저장과 수송기술을 통하여 발전이 아닌 중질가스로의 활용도 가능하게 될 것이다. 또한 여러 곳의 매립장에서 발생한 LFG를 한 곳으로 집중시켜 고질가스로 전환하는 설비비용을 절감할 수 있으며, 정제된 고질가스를 이용하여 발전보다 경제적인 자동차 연료나 도시가스로 활용할 수 있을 것이다. 본 연구에서는 LFG의 저장과 수송기술 중 GTS 기술을 통하여 저장과 수송에 제약이 크고 많은 비용이 소비되는 기체 상태의 에너지원을 하이드레이트화 시킴으로서 중 소규모 매립지에서 상대적으로 적은 비용으로 가스저장과 지상수송이 가능하게 할 수 있다. 본 연구의 결과로 LFG 에너지화 실증화 플랜트를 설계/제작 하였으며, 메탄+이산화탄소+물 하이드레이트 형성 실험 결과 4.56 Mpa, 277.2 K 조건에서 3시간을 한 사이클로 하는 공정운전을 가지는 것을 확인하였다. 이때 생성된 슬러리상의 하이드레이트를 고압으로 배출하여 펠릿으로 형성시켰으며, 형성된 하이드레이트 펠릿의 경우 92.27%의 메탄을 포함하는 것을 확인하였다.

  • PDF

Recycling Factor Analysis on Wood Wastes in the Construction Site by Classification Origination Reason (건설현장 폐목재의 발생원인 분류를 통한 재활용 요인분석)

  • Jung, Chan-Young;Kim, Jae-Jun;Jung, Young-Gi
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.1 s.35
    • /
    • pp.107-115
    • /
    • 2007
  • Today's human life is more conveniently advantaged and abundant as industrial society advanced. However, the development has been creating a serious environmental crisis. Environmental pollution and exhaustion of natural resources recently became an important issue in construction industry as well as the concern about construction waste management and recycling the resources has arisen. Because the industrial wastes are not only increased quantitatively but also qualitatively intricate and various, groping for ways of reducing the use of resources primarily and recycling is urged on promotion. Currently, only about 33% of the wood wastes produced in construction site are recycled and the others are incinerated or disposed through irregular circulation process. In this study, I will investigate the present status of generating, processing, and recycling construction wood wastes and compare domestic disposal trend to other countries. In addition, I will analyze the actual condition of processing wood wastes in the construction site, verify the irrational causes, and simplify anomalous factors for the purpose of more efficient and correct activation of wood waste treatment and recycling on construction field and protection of environment in the long run.

Emission Characterization of Particulate Matters According to the Types of Wastes from Industrial Waste Incinerator (산업폐기물 소각시설에서 폐기물 유형에 따른 입자상물질의 배출특성)

  • Park, Jeong-Ho;Suh, Jeong-Min;Jo, Jeong-Gu;Ryu, Jae-Yong;Han, Seong-Jong
    • Journal of Environmental Science International
    • /
    • v.16 no.11
    • /
    • pp.1225-1230
    • /
    • 2007
  • The emissions characteristics of particulate matters(PM) according to the types of wastes from industrial waste incinerator of 800 kg/hr treatment capacity were investigated. For this study, the incinerate waste are as follows; waste resin, waste wood, waste urethane, waste gunny, and waste paper. The particulate samples were collected to be emitted in stack and air pollution control(both cyclone and bag filter). In stack, the concentrations of PM were in the range of 2.61 to $26.51 mg/Sm^3$ and the major chemical species were C, Si, Cl, K, Na, Ca in all the wastes. In cyclone fly ash, the mean content of heavy metal were in the order of Fe > Zn > Pb > Cu > Mn > Cr > Ni > Cd > As > Hg and the heavy metal content of waste resin were Zn 34,197.5 mg/kg, Fe 27,587.6 mg/kg, Pb 6,055.8 mg/kg, respectively. In bag filter fly ash, the mean content of heavy metal were in the order of Zn > Pb > Fe > Cu > Mn > Cd > Cr > Ni > As > Hg and the heavy metal content of waste wood were Pb 36,405.2 mg/kg, Fe 15,762.9 mg/kg, Cu 9,989.5 mg/kg, Cd 2,230.1 mg/kg, respectively. Comparing the heavy metal content of both cyclone and bag filter, in cyclone, the Cr, Fe, Ni content were higher than in bag filter and the Cd, Cu, Hg content were lower than in bag filter.

Total content characteristics of inorganic and organic substances from wastes from thermal processes (열처리 공정에서 발생하는 무기·유기물질류의 함량특성)

  • Yeon, Jin-Mo;Kim, Woo-Il;Kang, Young-Yeul;Jeon, Tae-Wan;Jeong, Seong-Kyeong;Cho, Yoon-A;Kim, Min-Sun;Shin, Sun-Kyoung;Oh, Gil-Jong
    • Analytical Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.254-260
    • /
    • 2014
  • In this study, heavy metals, PCDD/PCDFs, PAHs in wastes generated from thermal processes were analyzed. Waste from lead thermal metalurgy (EWC 10 04) inorganic metal substances in the regulation were detected in the highest concentrations of Pb. EWC 10 04 seems to be a result of the dust. Waste from zinc thermal metalurgy (EWC 10 05) inorganic metal substances in the regulation were detected in high concentration of Zn. EWC 10 05 seems to be a result of the dust. Waste from copper thermal metalurgy (EWC 10 06) Cu in the 651,77 mg/kg to 651 times higher than regulation standard appeared in the copper thermal metallurgy process seems to be a result of dust. The concentrations of PCDD/PCDFs ranged from 0.0005~11.748 ng-TEQ/g in dust, 0.0027 ng-TEQ/g in fly ash. PCDD/PCDFs content was not detected in excessive value in regulation standard. PAHs concentration was in the range of ND~118.9 mg/kg in Naphthalene, ND~9.6 mg/kg in Phenanthrene, ND~48.4 mg/kg in Benzo[b]fluoranthene, ND~62.6 mg/kg in Benzo[a]pyrene, ND~10.7 mg/kg in Fluoranthene, ND~11.5 mg/kg in Benzo[a]anthracene.