• Title/Summary/Keyword: 평행평판

Search Result 158, Processing Time 0.027 seconds

A Study on the Coupling of a Flanged Parallel-Plate Waveguide to a Nearby Conducting Strip from the Viewpoint of Near-Field Scanning Microscopy (근접주사현미경의 관점에서 플랜지된 평행평판 도파관과 근접도체스트립과의 결합에 관한 연구)

  • Lee, Jong-Ig;Ko, Ji-Hwan;Cho, Young-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2260-2266
    • /
    • 2009
  • In this paper, the problem of electromagnetic coupling between a slit fed by a flanged parallel-plate waveguide (FPPW) and a nearby conducting strip parallel to the slit is studied as a simplified problem for a near-field scanning microscopy (NSM). The characteristics of the FPPW are investigated from the results for the variations of the equivalent slit admittance, the reactive powers near the slit inside and outside the FPPW, the magnitude and phase of the voltage reflection coefficient of the TEM wave. The performance of the proposed apparatus as an NSM is tested by examining the effects of various geometrical parameters such as guide height, slit width, strip width, distance between slit and strip, and the ratio of slit width to guide height on the magnitude and phase of the voltage reflection coefficient of the TEM wave. From the results for the voltage reflection coefficient against the strip offset from the slit, it is found that a slit in the FPPW with smaller guide height gives higher scanning resolution and the phase variation is more sensitive than the magnitude variation.

Diffraction Properties from Periodic Slot Array in the Upper Wall of Parallel Plate Waveguide (평행평판 도파관의 윗면에 위치한 주기적인 슬롯 배열에 의한 전자파의 회절특성)

  • Park Jin-Taek;Hong Jae-Pyo;Ko Ji-Whan;Cho Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.3 s.94
    • /
    • pp.311-318
    • /
    • 2005
  • Periodically perforated slot structure in the upper wall of the parallel plate waveguide is analyzed with main interest focusing on the diffraction Properties. The Periodic slot array is of infinite extent in one direction and of finite extent in the other direction. Various numerical results for reflection from the slotted section and transmission beyond the slotted section, and the radiation through the slotted section into the upper half space are presented with the height of feeding parallel plate waveguide, single slot size, and the periodicity between slots as parameters. This study is thought to be helpful to the design of the ventilation hole in the TFT-LCD and PDP.

Analysis of Electromagnetic Pulse Coupling Via a Slot Aperture into Parallel-Plate waveguide (슬롯 개구를 통한 평행평판 도파관 내부로의 전자파 펄스 결합문제 해석)

  • 이영순;박의준
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1204-1210
    • /
    • 2000
  • An analysis method for obtaining transient response of electromagnetic pulse(EMP) coupled via a slot aperture into a parallel-plate waveguide, is considered. The mixed-potential integral equation(MPIE), in which the vector and scalar potential Green's functions for the unknown equivalent magnetic surface current of the aperture in parallel-plate region are expressed in closed forms derived by use of the improved complex image method, is formulated. When the method of moments(MoM) is used to solve the MPIE, the matrix-fill time is significantly reduced because of closed-form Green's functions. In order to check the validity of the present method, the numerical results obtained by the present method are compared with those obtained by the previous method. Fairly good agreements between them are observed.

  • PDF

Study on Effective Point of Measurement for Parallel Plate Type ionization Chamber with Different Spacing (평행평판형 이온함의 두 전극간의 간격 변화에 따른 유효측정점에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this work, EPM (effective point of measurement) of parallel plate ionization chamber with three different spacing were investigated. If the plate separation is less than 2 mm one generally assumes that the effective point of measurement is just behind the front window of the parallel plate ionization chamber. For chamber with relatively large separation, such as the ones used for very accurate exposure measurements, this assumption breaks down and the EPM depends on plate separation and thickness of the front window. For parallel plate chambers, conventional theoretical analyses suggest that the EPM is the inner front wall and that it shifts towards the geometric centre of the chamber as the plate separation increases. The PP-IC (parallel plate ionization chamber) is fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far are 0.9, 1.9, and 3.1 cc. The gap between two electrodes ranges from 3, 6, and 10mm. Also the charge-to-voltage converter is designed to collect the electrons produced in the ionization chamber cavity. As the result of our experiment, the EPM shift was within 0.6 mm in photon beams and 0.4 mm to 2.5 mm in electron beams for the plate separation of 6 mm and 10 mm. EPM shifts towards the geometric center of the chamber as the plate separation increases.

  • PDF

The Flow Characteristics of ER Fluids According to the Electrode Shape of Two Parallel-Plate (평행평판의 전극형상에 따른 ER 유체의 유동특성 I)

  • Jang, S.C.;Yum, M.O.;Kim, D.T.;Kim, T.H.;Bae, T.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.207-212
    • /
    • 2001
  • Electro-Rheological(ER) fluid are suspensions which show an abrupt increase in rheological properties under electric fields. ER effects arise from electrostatic forces between the starch particles dispersed in the electrically insulating silicone oil, induced when an electric field is applied. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields. This paper presents performance analyses of four types of the two parallel-plate. Which have different electrode length and width but same electrode area. On the basis of the pressure drop and flow rate analysis. Four types of the two parallel-plate are designed and manufactured. Using ER fluid, it is possible to directly interface between electric signals and fluid power without moving parts.

  • PDF

Flow Rate-Pressure Drop Characteristics of Dispersive ER Fluid According to Change of Electric Field Strength in Clearance between Parallel Plates (평행평판 간극에서 전기장의 강도변화에 따른 분산계 ER유체의 유량-압력강하 특성)

  • 장성철;염만오;김도태
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.1
    • /
    • pp.78-83
    • /
    • 2003
  • Electro-rheological(ER) fluids are suspensions in which rheological properties show an abrupt change with variation of electric fields. We modeled the parallel-plates relating to ER-Valve system and yielded shear stress according to the strength of electric field. The purpose of the present study is to examine the flow characteristics of ER fluids according to the strength of electric field between parallel-plates. Then the steady relationship between pressure drop and flow rate of the ER fluids between parallel-plates under application of an electric fields was measured. The pressure drop and flow rates of ER fluids under the application of electric fields for steady flow were measured. For the experiment, we used the ER fluids, 35w% zeolite having hydrous particles and differential pressure gauge. This test reviewed experiment for the special changes of ER fluids in the steady flow condition.

Experimental Investigation on the Flow Characteristics of ER Fluids III (3nd Report, Flow-Pressure Drop Characteristics clearance between Two Parallel Plate) (ER유체의 유동특성에 관한 실험적 연구 III (평행평판 간극내의 유량-압려강하 특성))

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.399-404
    • /
    • 1999
  • Electro-rheological(ER) fluids are suspensions which show an abrupt increase in rheological properties under electric fields. The rheological response is very rapid and reversible when the electric field is imposed and/or removed. Therefore, there are many practical applications using the ER fluids. The purpose of the present study is to examine the flow characteristics of electro-rheological fluids. The field-dependent yield stress are obtained from experimental investigation on the Bingham property of the ER fluid. Then the steady relationshup between pressure drop and flow rate of the ERF was two fixed parallel-plates was measured under application of an electric fields. The electrical and rheological properties of zeolite based electro-rheological fluids were reported.

  • PDF

Numerical Analysis of Fluid Flow and Heat Transfer in a Parallel-Plate Channel with Transverse Fins (수직휜이 부착된 평행평판 채널내의 유동 및 열전달에 관한 수치해석)

  • Hwang, K.Y.;Kim, H.J.;Moh, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.642-653
    • /
    • 1995
  • An analysis is made of the laminar fluid flow and heat transfer characteristics in a parallel-plate channel to whose walls are fitted with a series of equidistant staggered fins placed transversely to the flow direction. The governing equations are solved numerically by a finite-volume method for elliptic flows. Based on the obtained solutions of flow and temperature fields, the effects of Reynolds number and various geometric parameters on the heat transfer performance and pressure drop are evaluated. A comparson of the heat transfer characteristics between the channels with and without staggered fins is also made.

  • PDF

Mixed convection heat transfer from vertically parallel and misaligned plates (수직 평판의 평행배열과 엇갈린 배열에서 혼합대류 열전달)

  • 김상영;정한식;권순석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.68-74
    • /
    • 1993
  • The mixed convection heat transfer has been studied numerically for misaligned and parrallel arrays of two flat plates at 100.leg.Re.leg.700, 0.1.leg.B.leg.1.0, 0.2.leg.leg.PHI.$_{R}$.leg.1Gr=10$^{4}$ and Pr=0.71. For misaligned plates and parallel plates, the optimum plate spacings move to the narrow spacing as Reynolds number and .PHI.$_{R}$ increase and can be expressed by the correlation equations at Gr=10$^{4}$. The optimum plate spacings for parallel plates sharply move to the narrow spacing compared with misaligned plates. The maximum mean Nusselt number of parallel plates shows higher value than that of misaligned plates and can be expressed by the correlation equations at Gr=10$^{4}$.EX>.

  • PDF

Analysis of Gas Discharge with Variation of Boundary Condition at Parallel Plate using Finite Element Methode (평행 평판 전극에서의 경계 조건의 변화에 따른 기체 방전의 유한 요소 해석)

  • Kim, Nam-Kyung;Kim, Dong-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1475_1476
    • /
    • 2009
  • 본 논문에서는 스트리머 방전에 대한 연구의 일환으로 전자사태의 발생과정 및 절연파괴현상을 2차원 유한요소법을 이용하여 해석하였다. 평행 평판 전극을 모델로 도입하고 전자밀도에 대한 경계조건을 변화시켜 각각 시뮬레이션을 통하여 신뢰성 있는 결과를 도출하였다.

  • PDF