• Title/Summary/Keyword: 평행류

Search Result 138, Processing Time 0.029 seconds

Distribution of Air-Water Two-Phase Flow in a Header of Aluminum Flat Tube Evaporator (알루미늄 평판관 증발기 헤더 내 공기-물 2상류 분지 실험)

  • Kim Nae-Hyun;Shin Tae-Ryong;Sim Yong-Sup
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.55-65
    • /
    • 2006
  • The air and water flow distribution are experimentally studied for a round header - flat tube geometry simulating a parallel flow heat exchanger. The number of branch flat tube is thirty. The effects of tube outlet direction, tube protrusion depth as well as mass flux, and quality are investigated. The flow at the header inlet is identified as annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted configuration, most of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, however, most of the water flows through rear part of the header. The protrusion depth, mass flux, or quality does not significantly alter the flow pattern. Possible explanations are provided based on the flow visualization results. Negligible difference on the water flow distribution was observed between the parallel and the reverse flow configuration.

The Design of a Sensor for Measuring Partial Discharge Signals in Rotating Machines (부분방전 검출을 위한 저, 고주파용 센서 해석 및 설계)

  • Heo Chang-Geun;Kim Yong-Joo;Kang Dong-Sik;Jung Hyun-Kyo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.6-10
    • /
    • 2004
  • 회전기기의 운전 상태에서 on-line 부분 방전시험은 고정자 권선의 절연상태를 검사, 평가 할 수 있는 중요한 수단으로서 이러한 부분방전시험을 통하여 회전기기 시스템의 사고예방을 위한 진단을 할 수 있다. 기존의 비접촉식 센서인 SSC는 부분방전 측정을 위하여 권선의 웨지 아래에 설치하는 방식으로 개발되어 [1], 설치가 불편하고 Global VPI 방식으로 제작된 소형 회전기에는 설치할 수 없는 단점이 있다. 본 논문에서는 소형 회전기에 사용가능한 저, 고주파용 부분방전 센서를 제안하였다. 웨지 위에 설치 가능한 SSC 형태의 마이크로스트립 센서 및 전송선로 이론을 이용한 2선 평행 전송선로 센서는 값이 싸고 소형 회전기에 설치할 수 있을 정도의 크기를 지니며, 기본적으로 센서의 구조가 고주파 웨이브가이드로서 고주파용 센서로 적합하다. 또한 저주파 신호를 검출하기 위한 센서로 로고우스키 코일 형태의 U 타입 센서는 와전류를 검출하는 센서로서 슬롯 외부에 설치 되어야 한다. 이러한 U 타입 센서와 마이크로스트립 센서 또는 2선 평행 전송선로를 동시에 설치할 경우 저, 고주파를 효과적으로 검출할 수 있다.

  • PDF

Heat and Mass Transfer Characteristics of a Falling Film Ammonia Absorber with Respect to the Vapor Flow Direction (유하액막식 암모니아 흡수기에서 증기 유동방향에 따른 열 및 물질전달 특성)

  • 권경민;정시영;김병주;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.16-25
    • /
    • 2004
  • The flow and heat/mass transfer in the falling-film of a heat exchanger can be influenced by the motion of the surrounding refrigerant vapor. In this study, the effect of the vapor flow direction on the absorption heat transfer has been investigated for a falling-film helical coil which is frequently used as the absorber of ammonia/water absorption refrigerators. The experiments were carried out for different solution concentration. The heat and mass transfer performance was measured for both parallel and counter-current flow. The effect of vapor flow on the heat and mass transfer is found to be increased with decreasing solution concentration. In the experiments with low solution concentration, whose vapor specific volume is great, the counter-current flow of vapor resulted in uneven distribution of falling-film and reduced the heat transfer performance of the absorber. The direction of the vapor flow hardly affected the thermal performance as the solution concentration became stronger since the specific volume of the ammonia/water vapor was much smaller than that of the water vapor.

A Study on the Refrigerant Distribution in an Aluminum Parallel Flow Heat Exchanger Header (알루미늄 평행류 열교환기 헤더 내 냉매 분배에 관한 연구)

  • Kim, Do-Young;Kim, Nae-Hyun;Kim, Su-Hwan;Byun, Ho-Won;Lee, Eul-Jong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1123-1128
    • /
    • 2009
  • The refrigerant R-134a flow distributions are experimentally studied for a round header/ten flat tube test section simulating a brazed aluminum heat exchanger. Three different inlet orientations (parallel, normal, vertical) were investigated. Tests were conducted with downward flow for the mass flux from 70 to $130\;kg/m^2s$ and quality from 0.2 to 0.6. In the test section, tubes were flush-mounted with no protrusion into the header. It is shown that normal and vertical inlet yielded approximately similar flow distribution. At high mass fluxes or high qualities, however, slightly better results were obtained for normal inlet configuration. The flow distribution was worst for the parallel inlet configuration. Possible explanation is provided based on flow visualization results.

  • PDF

Three Dimensional Computational Study on Performance and Transport Characteristics of PEMFC by Flow Channel Patterns (유로형상 변화에 따른 고분자 전해질 연료전지(PEMFC)의 성능 및 전달특성에 대한 3차원 수치 해석적 연구)

  • Lee, Pil-Hyong;Cho, Son-An;Choi, Seong-Hun;Hwang, Sang-Soon
    • New & Renewable Energy
    • /
    • v.2 no.4 s.8
    • /
    • pp.78-85
    • /
    • 2006
  • Selection of flow channel in the separation plate of PEMFC is very important parameter to improve its performance and reduce parasite loss. Flow patterns in the channel have great influence on the transport of hydrogen and air and removal of water generated from electrochemical reaction in diffusion layer. In this study. fluid flow in flow channel with parallel and interdigitated patterns are simulated three dimensionally on full flow domain including anode and cathode channel together. The numerical results show that the fuel cell with interdigitated flow channel represents better performance than that with parallel flow channel due to its strong convective transport across the gas diffusion layer. But the pressure drop in parallel flow channel is much more than that in interdigitated flow channel. And effects of temperature and stoichiometric number on performance can be calculated and analyzed as well. Nomenclature.

  • PDF

Humidity Distribution and Performance Variation of a PEMFC Multi Stack System According to the Direction of Anodic Supply (고분자 전해질 연료전지 멀티 스택 시스템의 수소극 흐름방향에 따른 습도분포 및 성능변화)

  • Lee, Yongtaek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.143-148
    • /
    • 2018
  • In this study the performance and humidity variation for 2 unit cells connected in series were experimentally measured. The relative flow direction of hydrogen and air was changed from parallel flow to counter flow. Internal humidity distribution was then measured by 5 embedded sensors on each channel. In all experimental conditions, the former unit cell showed a better performance and the gap is noted to be higher when counter flow is applied. The performance was noted to be higher at high humidification case in the parallel flow. However, in the counter flow, the difference of performance according to the humidification is negligible. Hydrogen and air are discharged from the PEMFC unsaturated with water vapor at parallel flow/low humidification condition, which explains lower performance of the PEMFC than other conditions. The humidities in hydrogen and air streams of counter flow were noted to increase rapidly even at low humidification condition and the consequential even hydration of membrane is the reason of higher performance.

Experimental of Study on Heat Transfer and Pressure drop of PF Heat Exchangers (PF 열교환기의 열전달과 압력강하 특성 실험 연구)

  • Um, Y.S.;Seo, D.N.;Park, K.M.;Lee, S.J.;Kim, D.H.;Kwon, Y.C.
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.519-524
    • /
    • 2008
  • In the present study, the air-side heat transfer and pressure drop characteristics of the fin-tube and PF heat exchangers have been experimentally investigated under the cooling standard condition. Fin type of PF heat exchanger is a triangler and squarer form. The experimental data of the slit fin-tube and two kinds of PF heat exchangers are measured using the air-enthalpy calorimeter and the constant temperature water bath. As the inlet air velocity increases, the heat transfer rate and pressure drop of the heat exchanger increased. The heat transfer rate and pressure drop of PF-2 heat exchanger of the squarer fin is larger than that of PF-1 heat exchanger of the triangler fin. As the inlet air temperature increases, the heat transfer rate decreases and the pressure drop is nearly uniform.

  • PDF

Experimental Study on the Heat Transfer Capacity and Dehumidification Performance of a Parallel Flow Evaporator for a Heat Pump Dryer (히트펌프 건조기용 PF 증발기의 능력과 제습량 실험 연구)

  • Kwon, Young Chul;Kim, Ki Young;Lee, Seok Hyun;Kwon, Jeong Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.516-521
    • /
    • 2013
  • In the present study, the performances of a fin-tube evaporator and three PF evaporators for a heat pump dryer were experimentally investigated. Among the tested evaporators, the PF3 type evaporator showed the highest values of heat transfer capacity and dehumidification performance, while the fin-tube evaporator had the lowest values. PF3 showed better performance compared to PF1 and PF2, due to the large pin pitch, which leads to more draining for dehumidified water. Also, the $45^{\circ}$ inclined PF evaporator presented better performance than that of the $90^{\circ}$ inclined PF evaporator, owing to its easier draining characteristics. The effect of air velocity was revealed to be quite large. When the air velocity increased by 20%, the heat transfer capacity and dehumidification performance increased 43%/11%, 48%/13% and 54%/23% for PF1, PF2 and PF3, respectively.

IMPROVEMENT OF FRESHENING PROCESS BY MEANS OF UNDERDRAINAGE CONDUIT (저층배수를 이용한 담수호화 촉진에 관한 연구)

  • 서영제;김진규
    • Water for future
    • /
    • v.25 no.1
    • /
    • pp.111-119
    • /
    • 1992
  • This paper is concerned with the actual comparison analysis for the freshening process in the two selected experimental reservoirs. At the deep freshening reservoir, the salinity and depth of the freshwater layer were estimated by simulation technique using the quantitative equation for the two-layered flow structures. First of all, it is shown that the effects of underdrainage conduit in the lower layer were reported more effective for the control of upper layer salinity comparing with the case of no underdrainage conduit. Further the results of computation were later compared with the real observed values and the relating parameters of the salt-balance equation are conformed even though approximately. Finally it was represented that the salinity of upper layer is easily diluted not only by the tidal gate but also by the underdrainge conduit in the lower layer of the freshening reservoir.

  • PDF

Neaushore sedimentary environments of the Sinyangri Fornation in Cheju Island, Korea (제주도 신양리층의 연안퇴적환경)

  • 한상준;윤호일
    • 한국해양학회지
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 1987
  • The Sinyangri Formation crops out in the vicinity of the Seongsan Peninsula, Cheju Island. Based on sedimentary structures, texture and composition, the lithologic sequence has been classified, in ascending stratigraphic order, into three lithofacies: parallel laminated sandstone facies (Facies I): conglomerate facies(Facies Il); and cross stratified sandstone facies (F acies Ill). Wedge-to-parallel, seaward-inclined in low angle less than 10$^{\circ}$lamina -sets with alternations of coarseand fine-grained sediments in the Facies I are the characteristic sedimentary structures in the foreshore depositional environment. Grains of this faciesare well sorted with good roundness compared with the other two facies, partly showing inverse graded bedding. Facies II,largely composed of claset-supported,very poorly-sorted conglomerates,does not pinch out but occurs continuously along the Sinyangri beach.Interstitial spaces between the clasts are mostly infilled with volcanic-ash and small amounts of well-rounded shell fragments.Maximum bed thickness as well as the size of imbedded basaltic clasts decreases to the south(toward Sinyangri). Large clasts with parallel lamination originated from the underlying Facies i,are generally elongated parallel to the bedding plane and display no systematic horizontal variations in size indicative of in-situ clasts.In view of the facts above it seems that large gravels from the basaltic rocks are transgressive lag conglomerates which are partly affected by the combination of longshore currents and propagating wave.Local occurrence of cross-strata dipping toward the south in the upper part of Facies IIreinforces the evidence of the action of longshore currents. Facies IIIis characterized by bidirectional trough cross-starifiction and wave ripples associated with the upper shoreface(surfzone) environments.In summary,the Sinyangri Formation represents the depositional environments of foreshore to upper shoreface truncated by disconformity between Facies Iand II.

  • PDF